N819US
McDonnell Douglas DC-9-81(MD-81) FAA →
earlier registrations
1 past record
service difficulty reports
41 reports
- 2 Oct 2001
Battery, discharged
IND - THE LOW LEVEL EMERGENCY LIGHTS AND THE AFT SECTION OF CEILING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE LOW LEVEL EMERGENCY LIGHT…
- 2 Oct 2001
Battery, discharged
IND - THE LOW LEVEL EMERGENCY LIGHTS AND THE AFT SECTION OF CEILING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE LOW LEVEL EMERGENCY LIGHT…
- 21 Sep 2001
Light, inoperative
THE FORWARD ENTRANCE DOOR EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT ASSEMBLY. (M)
- 3 Sep 2001
Battery, discharged
IND - THE SEAT MOUNTED LOW LEVEL EMERGENCY LIGHTS, LEFT AND RIGHT AFT OVERWING EXIT EMERGENCY LIGHTS, AND THE AFT FUSELAGE REMOTE RECEIVER WERE INOPERATIVE.…
- 3 Sep 2001
Receiver, failed
IND - THE SEAT MOUNTED LOW LEVEL EMERGENCY LIGHTS, LEFT AND RIGHT AFT OVERWING EXIT EMERGENCY LIGHTS, AND THE AFT FUSELAGE REMOTE RECEIVER WERE INOPERATIVE.…
- 3 Sep 2001
Lanyard, out of position
IND - THE TAIL CONE EVACUATION SLIDE COVER WAS NOT ATTACHED AT THE AFT HINGE POINTS AND THE MANUAL DEPLOY LANYARD WAS NOT ROUTED PROPERLY. MAINTENANCE…
- 3 Sep 2001
Battery, discharged
IND - THE SEAT MOUNTED LOW LEVEL EMERGENCY LIGHTS, LEFT AND RIGHT AFT OVERWING EXIT EMERGENCY LIGHTS, AND THE AFT FUSELAGE REMOTE RECEIVER WERE INOPERATIVE.…
- 13 Apr 2001
Battery, discharged
IND - THE LOW LEVEL EMERGENCY LIGHTS AND SEVERAL CABIN CEILING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE LOW LEVEL AND CABIN CEILING…
- 13 Apr 2001
Battery, discharged
IND - THE LOW LEVEL EMERGENCY LIGHTS AND SEVERAL CABIN CEILING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE LOW LEVEL AND CABIN CEILING…
- 20 Mar 2001
Module, failed
IND - THE LOW LEVEL EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE AFT CONTROL MODULE. (M)
- 21 Nov 2000
Battery, discharged
PIT - THE EMERGENCY LIGHTS WERE DIM. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERIES. (M)
- 20 Nov 2000
Battery, discharged
PIT - THE EMERGENCY LIGHTS AT SEAT ROWS 6 THROUGH 16 AND THE LOW LEVEL EMERGENCY LIGHT AT ROW 30 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES FOR THE…
- 20 Nov 2000
Battery, discharged
PIT - THE EMERGENCY LIGHTS AT SEAT ROWS 6 THROUGH 16 AND THE LOW LEVEL EMERGENCY LIGHT AT ROW 30 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES FOR THE…
- 22 Sep 2000
Light, failed
PHL - THE LOW LEVEL EMERGENCY LIGHT AT SEAT ROW 25 WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT ASSY AT SEAT ROW 25. (M)
- 17 May 2000
Valve, failed
IND/PIT - FLT 850 - DURING CRUISE, THE CABIN ALTITUDE STARTED CLIMBING AND COULD NOT BE CONTROLLED. AFTER LOWERING THE AIRCRAFT ALTITUDE TO 12,400 FEET, THE…
- 17 May 2000
Valve, failed
IND/PIT - FLT 850 - DURING CRUISE, THE CABIN ALTITUDE STARTED CLIMBING AND COULD NOT BE CONTROLLED. AFTER LOWERING THE AIRCRAFT ALTITUDE TO 12,400 FEET, THE…
- 17 May 2000
Seal, deteriorated
IND/PIT - FLT 850 - DURING CRUISE, THE CABIN ALTITUDE STARTED CLIMBING AND COULD NOT BE CONTROLLED. AFTER LOWERING THE AIRCRAFT ALTITUDE TO 12,400 FEET, THE…
- 24 Mar 2000
Door Frame, corroded
PIT - FOUND CORROSION ON DOOR JAMB 1.5 INCH BY 2 INCH, DOOR JAMB BEAM STATION 1170 TO 1212. DEFECTIVE PART REPLACED WITH NEW BEAM. (M)
- 13 Mar 2000
Longeron, cracked
PIT - FOUND LONGERON 10 STATION 1307, CRACKED .5 INCH LONG. CUT OUT DAMAGED SECTION AND SPLICED IN NEW. (M)
- 29 Jan 2000
Light, malfunctioned
TPA - THE PORTABLE EMERGENCY LIGHT BY THE MAIN ENTRY DOOR ILLUMINATES WHEN THE COCKPIT EMERGENCY LIGHT SWITCH IS TURNED OFF. MAINTENANCE REPLACED THE PORTABLE…
- 25 Dec 1999
Slide, malfunctioned
PIT - THE AFT SERVICE DOOR EMERGENCY EVACUATION SLIDE FAILED TO INFLATE IN ALLOCATED TIME DUE TO DELAYED START OF INFLATION AFTER DOOR OPENING. MAINTENANCE…
- 9 Nov 1999
Power Supply, failed
MCO - THE EMERGENCY LIGHTS WERE REMAINING ON AFTER THE AIRCRAFT WAS SHUTDOWN. MAINTENANCE REPLACED THE FORWARD EXIT WINDOW BATTERY POWER SUPPLY, THE LOW LEVEL…
- 15 Sep 1999
Skin, cracked
PIT - DURING THROUGH FLIGHT, FOUND 1.25 INCH CRACK IN SKIN AT STATION 58.750, 4.5 INCH BELOW FLOOR LINE RT SIDE. INSTALLED FLUSH REPAIR PER SRM 53-01, FIG 4…
- 15 Sep 1999
Skin, cracked
PIT - DURING RON, FOUND 1 INCH CRACK IN SKIN WITH EXTERNAL DOUBLER WITHIN 24 INCHES OF AOA VANE AT STATION 58.750, 4 INCHES BELOW FLOOR LINE LEFT SIDE.…
- 4 Jun 1999
Battery Pack, discharged
IND - MAINTENANCE FOUND THREE PASSENGER CABIN SEATS WITH THE EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE THREE BATTERY PACKS.…
- 4 Jun 1999
Battery, discharged
CLT - FLOOR LEVEL EMERGENCY LIGHT AT ROW 11 IS ILLUMINATED. MAINTENANCE REPLACED THE BATTERY. DURING CHECK OF SYSTEM, FOUND LIGHT AT ROW 5 INOPERATIVE.…
- 17 Aug 1998
Frame, corroded
PIT - DURING C-6 CHECK, FOUND CORROSION IN TWO AREAS, 1 FT BY 1 INCH AT STATION 1463 CANTED FRAME LOWER MEMBER, LEFT OF CENTER. BLENDED OUT CORROSION AND…
- 6 Jun 1998
Battery, discharged
PIT - FOUND SEAT MOUNTED AISLE EMERGENCY LIGHT INOPERATIVE AT SEAT 16D. MAINTENANCE REPLACED THE BATTERY. (X)
- 22 Mar 1998
Fuel Indication, malfunctioned
BWI - FLT 545 - THE A/C WAS OPERATING UNDER MEL 28.2, CENTER TANK FORWARD BOOST PUMP INOPERATIVE. IT WAS DETERMINED THE LINE OF FLIGHT COULD OPERATE WITH THE…
- 19 Jan 1998
Battery, discharged
PHL - CABIN LOW LEVEL LIGHTS FAILED TEST. MAINTENANCE REPLACED BATTERIES. (M)
- 18 Nov 1996
Wheel, shimmied
FLT 359 - CLT-GSP - AT TAKEOFF NOSE WHEEL SHIMMIED. AFTER GEAR RETRACTION THERE WAS A BURNED RUBBER SMELL IN THE COCKPIT. CREW LOWERED GEAR AND PERFORMED…
- 27 Dec 1995
Spar, cracked
PIT - DURING Q-1/C-3 INSPECTION, FOUND A 3 INCH CRACK, VERTICAL STABILIZER FRONT SPAR AFT OF CANTED FRAME 1388. REMOVED DAMAGED AREA AND INSTALLED REPAIR…
- 27 Dec 1995
Longeron, cracked
PIT - DURING Q-1/C-3 CHECK INSPECTION, FOUND 1 INCH CRACK AT RIVET HOLE IN LONGERON 2R AT STA 1418, OUTBOARD LEG. SPLICED IN NEW SECTION OF LONGERON PER SRM…
- 27 Dec 1995
Frame, corroded
PIT - DURING Q-1/C-3 CHECK INSPECTION, FOUND 2 INCH BY 5 INCH LEVEL 1 CORROSION PREVIOUSLY REWORKED AFT SIDE OF FRAME WEB, STA 1338, BETWEEN LONGERONS 28R AND…
- 27 Dec 1995
Frame, cracked
PIT - DURING Q-1/C-3 CHECK INSPECTION, FOUND 4 INCH CRACK IN FRAME MLG JAMB KEEL AREA, STA 937, CENTER SECTION. MANUFACTURED DOUBLER AND ANGLE REPAIR PER SRM…
- 27 Dec 1995
Bulkhead Web, gouged
PIT - DURING Q-1/C-3 CHECK INSPECTION, FOUND TOOLING MARKS (GOUGES), 6 INCH BY 4 INCH AREA BETWEEN LONGERON 27L AT BOTTOM LT SIDE OF AFT PRESSURE BULKHEAD.…
- 27 Dec 1995
Pan, cracked
PIT - DURING Q-1/C-3 CHECK INSPECTION, FOUND LOWER FORWARD CARGO DOOR PAN CORRODED/CRACKED IN 2 PLACES APPROXIMATELY .50 INCH IN LENGTH EACH. ACCOMPLISHED…
- 27 Dec 1995
Angle, cracked
PIT - DURING Q-1/C-3 CHECK INSPECTION, FOUND .75 INCH VERTICAL CRACK AFT SIDE OF STA 1388, CANTED FRAME, IN ANGLE ON LEFT FRONT SPAR OF VERTICAL STABILIZER.…
- 6 Jul 1995
Jamb, cracked
IND - DURING CX-6 CHECK INSPECTION, FOUND 1 INCH SQUARE AREA OF CORROSION WITH .125 INCH CRACK IN FORWARD CARGO DOOR JAM LOWER PAN. ACCOMPLISHED DOUBLER…
- 13 Apr 1995
Eel Batteries, discharged
CLT - THE COCKPIT EMERGENCY LIGHTS DO NOT ILLUMINATE. MAINTENANCE REPLACED THE BATTERIES ON THE COCKPIT EMERGENCY LIGHT POWER SUPPLY. OPERATIONS CHECKED GOOD.…
- 12 Apr 1995
Eel Batt Pack, discharged
PHL - THE EXTERIOR EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK. OPERATIONS CHECKED NORMAL. (Z)