  1. 2 Jul 2004

    Floorboard, sheared

    Doug DC982

    FTW - FOUND G1 FORWARD INBOARD MOUNT NUT PLATE SHEAREDON INSTALLATION. REMOVED FLOORBOARD AT OUTBOARD STATION 160-200. FLOORBOARD HAS EXTENSIVE DELAMINATION.…

  2. 29 Jun 2004

    Floor Panel, corroded

    Doug DC982

    FTW - FOUND MAIN CABIN STATION 1250 TO STATION 1155 LEFT SIDE INBOARD FLOOR PANEL HAS SEVERAL INSERTS CORROSION SOFT/MUSHEY EDGE FILLER IS MISSING. FABRICATED…

  3. 25 Jun 2004

    Bracket, cracked

    Doug DC982

    FTW - FOUND FORWARD PIT DOOR AFT LOWER INTERNAL EDGE BRACKET CRACKED. REMOVED CRACKED BRACKET. FABRICATED BRACKET. INSTALLED NEW BRACKET. (M)

  4. 24 Jun 2004

    Skin, worn

    Doug DC982

    FTW - FOUND R1 DOOR LOCK TO HAVE EXCESSIVE MATERIAL LOSS ON LOWER SKIN. (M)

  5. 23 Jun 2004

    Skin, damaged

    Doug DC982

    FTW - FOUND EXISTING REPAIR AT FS 427 BETWEEN LONGERONS 18 AND 20R REQUIRES TO BE REPLACED WITH DC9/MD80 SRM 53-05 FIG 105 REPAIR. INSTALLED REPAIR NO LONER…

  6. 23 Jun 2004

    Skin, damaged

    Doug DC982

    FTW - FOUND 20 INCH CREASE AT FS 617 BETWEEN LONGEORN 22 AND 23R, CREASE IS IN THE CONTROLLED RVSM AREA AND MUST BE REPAIRED. CUT OUT DAMAGED SKIN BETWEEN…

  7. 22 Jun 2004

    Intercostal, cracked

    Doug DC982

    FOUND CABIN FLOOR STATION 769-788 BL 0 INTERCOSTAL UPPER FLANGE IS CRACKED AROUND FASTENER HOLES WITH MATERIAL MISSING AT 2 LOCATIONS. REMOVED INTERCOSTAL.…

  8. 22 Jun 2004

    Floor Panel, cracked

    Doug DC982

    FTW - FOUND MAIN CABIN RIGHT INBOARD FLOOR PANEL STATION 1250-1309 HAVE CRACKS, DAMAGE ON EDGES/SEVERAL INSERTS HAVE PULLED THROUGH. FABRICATED NEW FLOOR…

  9. 22 Jun 2004

    Floorboard, damaged

    Doug DC982

    FTW - FOUND MAIN CABIN STATION 1117 TO 1174 CENTER FLOOR PANEL HAVE SOFT/MUSHEY AND DAMAGE ON EDGE. FABRICATED CABIN FLOORBOARD. (M)

  10. 22 Jun 2004

    Floor Panel, cracked

    Doug DC982

    FTW - FOUND MAIN CABIN STATION 806 TO STATION 826, FLOOR PANEL ONE INSERT DAMAGE/CRACKS ON EDGES. FABRICATED NEW FLOOR PANEL. (M)

  11. 21 Jun 2004

    Floorboard, broken

    Doug DC982

    FTW - FOUND FLOORBOARD FASTENER INSERTS MISSING, TWO EACH STATION 200-260 LBL 24-25. UPON FURTHER INVESTIGATION FLOORBOARD PANEL FOUND TO BE BROKEN.…

  12. 21 Jun 2004

    Floorboard, broken

    Doug DC982

    FOUND FLOORBOARD BROKEN STATION 200-260 LBL 24-31. FABRICATED FLOORBOARD. (M)

  13. 21 Jun 2004

    Frame, cracked

    Doug DC982

    FTW - FOUND LT WING FIXED LEADING EDGE COMPARTMENT XFS 267 TWO EACH, FRAME CRACKED. STOP DRILLED CRACKS. FABRICATED TWO REPAIR DOUBLER. INSTALLED TWO FORMER…

  14. 20 Jun 2004

    Frame, cracked

    Doug DC982

    FTW - FOUND LOWER FIXED LEADING EDGE COMPARTMENT XFS 330 LEADING EDGE FRAME CRACK. STOP DRILL CRACK AT FORMER. FABRICATED 3 AND DRILLED REPAIR FORMER.…

  15. 19 Jun 2004

    Seat Track, corroded

    Doug DC982

    FTW - FOUND RIGHT OUTBOARD SEAT TRACK STATION 200-1309 IS CORRODED AND GOUGED ALONG ENTIRE LENGTH, FS 494 IS OUT OF LIMITS. REMOVED DAMAGED SECTION OF SEAT…

  16. 19 Jun 2004

    Seat Track, corroded

    Doug DC982

    FOUND LEFT INBOARD SEAT TRACK STATION 200-1309 IS CORRODED AND GOUGED ALONG ENTIRE LENGTH. REMOVED CORROSION STATION 200-236 IS OUT OF LIMITS. MATERIAL LOSS…

  17. 25 Apr 2004

    Strap, misinstalled

    Doug DC982

    TAIL SLIDE COVER HOLD DOWN STRAPS NOT INSTALLED CORRECTLY. INSTALLED TAIL CONE EMERGENCY SLIDE COVER STRAPS CORRECTLY.

  18. 10 Apr 2004

    Light, loose

    Doug DC982

    ORD - FLT 1504 - AFT GALLEY AISLE EXIT LIGHTING TRACK CAME UP. RE-ATTACHED AFT GALLEY LUMINESCENT EXIT STRIP. (M)

  19. 8 Apr 2004

    Sign, dislodged

    Doug DC982

    EXIT SIGN AT AFT GALLEY FELL OFF ON TAKEOFF. RE-ATTACHED LUMINESCENT EXIT STRIP AT AFT GALLEY FLOOR AREA. (M)

  20. 30 Jan 2004

    Landing Gear, malfunctioned

    Doug DC982

    PBI - FLT 833 - AFTER TAKEOFF, THE NOSE GEAR FAILED TO RETRACT. CYCLED GEAR DOWN, NOSE GEAR GREEN LIGHT ON INSTANTLY. RECYCLED GEAR UP. NOSE GEAR FAILED TO…

  21. 28 Jan 2004

    Glowstrip, loose

    Doug DC982

    DTW - FLT 834 - AFT GALLEY FLOOR GLOW STRIP OFF. REINSTALLED GALLEY FLOOR AFT GLOWSTRIP. NO OTHER DEFECTS NOTED. (M)

  22. 26 Jan 2004

    Proximity Sensor, malfunctioned

    Doug DC982

    FLL - FLT 1123 - NOSE GEAR UNSAFE LIGHT WOULD NOT EXTINGUISH UPON RETRACTION. RECYCLED PER QRH, WHICH DID NOT REMEDY SITUATION. LIGHT FINALLY WENT OUT…

  23. 20 Jan 2004

    Glowstrip, missing

    Doug DC982

    MCO - FLT 1863 - FLOOR GLOW PATH STRIP MISSING BY L2 DOOR. REPLACED MISSING SAFTGLO SUPPORT FLOOR PATH STRIP. (M)

  24. 15 Jan 2004

    Engine, flamed out

    Doug DC982

    RT ENG FLAMED-OUT, AIR RETURN AT 800 TO 1000 MLS RT ENG EPR DROPPED BELOW 1.2 EPR, ARTS FIRED BASES X-TERED TO LT GENERATORS ACCOMPLISHED QRH ITEMS PULLED CVR…

  25. 28 Sep 2003

    Conduit, out of position

    Doug DC982

    LEFT MAIN RED GEAR LIGHT ON WITH LANDING GEAR HANDLE UP. QRH PROCEDURE FOLLOWED, NO CHANGE. REPOSITIONED LT MAIN GEAR UPLOCK SENSOR CONDUIT AND OPS CHECKED.…

  26. 14 Sep 2003

    Control Unit, malfunctioned

    Doug DC982

    LT ENGINE LOOP 'A' LIGHT ILLUMINATED. ACCOMPLISHED QRH PROCEDURE. REMOVED AND REPLACED CONTROL UNIT. OPS CHECK NORMAL. (M)

  27. 26 Aug 2003

    Blade, damaged

    Doug DC982

    NR 2 ENGINE 1ST STAGE FAN BLADE IS MANGLED BEYOND BLENDABLE LIMITS. REMOVED AND REPLACED TWO C-1 BLADES IAW MD-80 A/C MM REV 76 REV 76 SECTION 72-33-21.…

  28. 26 Aug 2003

    Inlet Guide Vane, cracked

    Doug DC982

    ENGINE 2-217A ESN 708450 INLET GUIDE VANE HAS ROOT AND INNER SHROUD WELD TO SHROUD CRACKED. REMOVED AND REPLACED IGV CASE. (M)

  29. 1 Jun 2003

    Bracket, damaged

    Doug DC982

    SLIDE PACK BRACKET ON R-1 DOOR WILL NOT HOLD SLIDE PACK GIRT BAR. REPOSITIONED AFT GIRT BAR HOOK ON R-1 SLIDE PACK. GIRT BAR OPERATION NORMAL. (M)

  30. 24 Apr 2003

    Engine, smoke

    Doug DC982

    AIR RETURN, ON TAKEOFF AFT CABIN FILLED WITH SMOKE. AFT LAV SMOKE ALARMS WENT OFF. RETURNED TO DTW. REMOVED AND REPLACED NR 2 ENGINE. OPS CHECK AND LEAK GOOD,…

  31. 2 Apr 2003

    Smoke Detector, malfunctioned

    Doug DC982

    CARGO FIRE DETECTION FORWARD 'B' FAIL LIGHT AND ANNUNCIATOR PANEL SMOKE DETECTOR LOOP LIGHT ILLUMINATED. REMOVED AND REPLACED CARGO COMPARTMENT SMOKE…

  32. 10 Mar 2003

    Screw, missing

    Doug DC982

    LEFT FORWARD OVERWING EMERGENCY EXIT WINDOW IS STUCK CLOSED. FORWARD SCREW ON EXIT COVER MISSING THUS JAMMING DOOR CLOSED. INSTALLED SCREW ON COVER, DOOR NOW…

  33. 29 Nov 2002

    Ring, corroded

    Doug DC982

    FTW - FOUND LEFT 346 WINDOW UPPER AFT FRAME CORRODED. REMOVED LEFT NR 46 WINDOW UPPER AFT CRACKED FRAME. LOCATED AND DRILLED NEW ORDERED WINDOW RING.…

  34. 27 Nov 2002

    Floor Support, corroded

    Doug DC982

    FTW - L2 DOOR OPENING FLOOR PANEL SUPPORT BRACKETS (2) CORRODED. FORWARD FLOOR PANEL SUPPORT BRACKET L2 DOOR FOUND TO BE OUT OF LIMITS. FABRICATED FORWARD…

  35. 24 Nov 2002

    Attach Angle, cracked

    Doug DC982

    FTW - FOUND DORSAL FIN INBOARD LEFT, RIGHT ANGLE ATTACH IS CRACKED. REMOVED LEFT AND RIGHT FIN INBOARD ATTACH ANGLES. LOCATED AND DRILLED LEFT INBOARD FIN…

  36. 23 Nov 2002

    Seat Track, corroded

    Doug DC982

    FTW - FOUND RIGHT INBOARD SEAT TRACK CORRODED AT STATION 200 AND 256. MATERIAL LOSS OUT OF LIMITS AT SEAT TRACK STATION 267. REMOVED DAMAGE AREA. FABRICATED…

  37. 21 Nov 2002

    Door Frame, corroded

    Doug DC982

    FTW - FOUND AFT CARGO JAMB BEAM HAS CORROSION STATION 1112-1249, DOOR JAMB BEAM REPAIR STRAP HAS CORROSION UNDER STRAP ON JAMB BEAM. CORRODED REMOVAL WAS…

  38. 21 Nov 2002

    Longeron, corroded

    Doug DC982

    E/E BAY STATION 180-218 L30 CORROSION IN LONGERON AROUND FASTENERS. REMOVED DAMAGED SECTION OF LONGERON AND SPLICE. INSTALLED NEW LONGERON AND SPLICE. (M)

  39. 21 Nov 2002

    Web, cracked

    Doug DC982

    FTW - FOUND PAX CABIN STATION 503, STATION 231 WEB MEMBRANE IS CRACKED. STOP DRILLED CRACK. FABRICATED DOUBLER. INSTALLED DOUBLER REPAIR. STOP DRILL CRACK AT…

  40. 18 Nov 2002

    Intercostal, cracked

    Doug DC982

    FTW - FOUND L1 DOOR UPPER MOST INTERCOSTAL BEAM (TWO) CRACKS IN LOWER RADIUS FORWARD AND AFT SIDES. REMOVED CRACKED DOOR BEAM. FORMED BEAM. INSTALLED DOOR…

  41. 17 Nov 2002

    Stringer, cracked

    Doug DC982

    FTW - AFT ACCESSORY COMPARTMENT 1474 CANT LONGERON 18L, 1 INCH CRACK ON STRINGER. STOP DRILL CRACK. FABRICATED TWO FORMER DOUBLERS. INSTALLED TWO FORMER…

  42. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  43. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  44. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  45. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  46. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  47. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  48. 17 Nov 2002

    Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…

  49. 17 Nov 2002

    Door Frame, corroded

    Doug DC982

    FTW - FOUND DOOR JAMB BEAM REPAIR STRAP HAS CORROSION UNDER STRAP AND ON JAMB BEAM. REMOVED DOOR JAMB BEAM TO BE OUT OF LIMITS. HOLES LOCATED AND DRILLED ON…

  50. 16 Nov 2002

    Skin, damaged

    Doug DC982

    FTW - FOUND EXISTING REPAIRS AT FS 301 AND FS 310 BETWEEN L23R AND L25R ARE TOO CLOSE TOGETHER AND REQUIRES REPAIRS TO BE COMBINED. CUT OUT DAMAGED AREA.…

  51. 16 Nov 2002

    Floorboard, damaged

    Doug DC982

    FTW - FLOORBOARD PANEL FS 1118-1184 BL0-BL23 HAS CORRODED INSERTS AND PUNCHER WITH DELAMINATION. FABRICATED NEW FLOORBOARD FS 1118-1184. (M)

  52. 16 Nov 2002

    Support, corroded

    Doug DC982

    FTW - FOUND MID PIT STATION 636 TO 693 CORROSION AT T-SUPPORT INBOARD BEAM AND ELONGATED HOLES. REMOVED THE INBOARD BEAM T-SUPPORT. LOCATED AND DRILLED NEW…

  53. 16 Nov 2002

    Angle, corroded

    Doug DC982

    FTW - FOUND MID PIT STATION 541 FORWARD BULKHEAD AFT FACE HAS CORROSION AT ANGLE LOWER ATTACH TO BULKHEAD RBL 16 INCH LBL 16 INCHES. REMOVED LOWER ANGLE.…

  54. 16 Nov 2002

    Doubler, corroded

    Doug DC982

    FTW - FOUND MID PIT HAS CORROSION AT DOUBLER RAD ALT RECEIVER 1, RAD ALT TRANSMITTER 1, RAD ALT TRANSMITTER 2, RAD ALT RECEIVER 2. THE DAMAGED TO THE RAD ALT…

  55. 16 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENTS AT STATION 200 AT LONGERONS 22-23L, 23-24L, 24-25L, DUE TO THESE DENTS CLOSE PROXIMITY TO EACH OTHER. REPAIR MUST BE ACCOMPLISHED. REWORKED…

  56. 16 Nov 2002

    Skin, damaged

    Doug DC982

    FTW - FOUND EXISTING REPAIRS AT FS 320 AND FS 330 REQUIRES TO BE COMBINED INTO A SINGLE REPAIR. REMOVED EXISTING REPAIRS AT FS 320 AND FS 330. CUT OUT…

  57. 16 Nov 2002

    Floor Panel, damaged

    Doug DC982

    FTW - FOUND CAPTAIN FLOOR PANEL NEXT TO CONTROL COLUMN HAS DELAMINATED AND BROKEN WOOD FILLER AS MARKED. LOCATED AND DRILLED NEW PANEL. (M)

  58. 16 Nov 2002

    Intercostal, corroded

    Doug DC982

    STA 1322-1338, LONGERON 22 LT INTERCOSTAL HAS CORROSION. REMOVED 2 INTERCOSTALS AT STA 1322-1338, 22L, 21L. FABRICATED 2 EA INTERCOSTAL. INSTALLED 2 EA…

  59. 15 Nov 2002

    Intercostal, cracked

    Doug DC982

    FTW - FOUND AFT PIT STATION 1287-1309 BL 0 INTERCOSTAL UPPER FLANGE CRACKED AT FASTENER HOLES. REMOVED UPPER FLANGE REPAIR ANGLE. FABRICATED ANGLE. INSTALLED…

  60. 15 Nov 2002

    Web, cracked

    Doug DC982

    FTW - FLOOR WEB CRACKED TWO PLACES BETWEEN STATION 1287-1309 RIGHT. FABRICATED DOUBLERS. UPON FURTHER EVALUATION 3 CRACKS WERE FOUND. INSTALLED DOUBLERS. (M)

  61. 15 Nov 2002

    Splice, corroded

    Doug DC982

    FTW - FOUND FORWARD CARGO FS 227 STRINGER 28L SPLICE FITTING CORRODED. REMOVED LONGERON SPLICE. LOCATED AND DRILLED NEW SPLICE. INSTALLED SPLICE. (M)

  62. 15 Nov 2002

    Splice, corroded

    Doug DC982

    FTW - FOUND FORWARD PIT FS 227 STRINGER 27L SPLICE FITTING CORRODED. REMOVED SPLICE FITTING. FORMED SPLICE. INSTALLED SPLICE. (M)

  63. 15 Nov 2002

    Door Frame, corroded

    Doug DC982

    FTW - FOUND FORWARD CARGO PIT DOOR JAMB BEAM LOWER SECTION CORRODED. REMOVED DOOR JAMB INNER PANEL. HOLES LOCATED AND DRILLED ON NEW PANEL. INSTALLED NEW…

  64. 15 Nov 2002

    Skin, damaged

    Doug DC982

    FTW - FOUND TEMP REPAIR AT STATION 474 LONGERON 30 (VHF ANT) REQUIRES ACTIONS. REMOVED EXTERNAL DOUBLER. FABRICATED INNER SKIN. FABRICATED FOUR TEE ANGLES.…

  65. 15 Nov 2002

    Stringer, corroded

    Doug DC982

    FTW - FOUND FORWARD CARGO STRINGER 28L CORRODED AT FS 218-237, 53) 237-256, 58) 275-294, 67) 330-351. STRINGER 28L B7W STATION 229 AND STATION 243 FOUND TO BE…

  66. 14 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENT RIGHT SIDE FS 605 BETWEEN LONGERONS 20R AND 21R. FABRICATED DOUBLER FOR STATION 602. INSTALLED REPAIR DOUBLER. (M)

  67. 14 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENT LEFT SIDE FUSELAGE FS 209 LONGERON 14L. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)

  68. 14 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENT RIGHT SIDE FS 353 BETWEEN LONGERON 22R AND 23R. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)

  69. 14 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENT RIGHT SIDE FS 622 BETWEEN LONGERONS 21R AND 22R. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER. (M)

  70. 13 Nov 2002

    Seat Track, damaged

    Doug DC982

    FTW - FOUND PASSENGER SEAT TRACK LEFT, OUTBOARD WORN AT FS 998-1010, GOUGE 1019, CORROSION 1037-1041, WORN 1059-1067, 1087-1098, CORROSION 1240. LEFT,…

  71. 13 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENT RIGHT SIDE FUSELAGE STATION 463 BETWEEN LONGERONS. FORMED NEW DOUBLER REPAIR. INSTALLED NEW DOUBLER REPAIR. (M)

  72. 12 Nov 2002

    Skin, dented

    Doug DC982

    FTW - FOUND DENT LEFT SIDE FS 218 BETWEEN LONGERON 15L AND 16L. DENT LEFT SIDE FUSELAGE STATION 216 BETWEEN LONGERONS 15L AND 16L. FABRICATED DOUBLER.…

  73. 12 Nov 2002

    Seat Track, corroded

    Doug DC982

    FTW - FOUND PASSENGER SEAT TRACK RIGHT OUTBOARD, GOUGE AT FS 248, 291, CORROSION AT FS 256, 277, 301, 340, 400-418, 424-447, 458-478, 492-496, 523-536,…

  74. 12 Nov 2002

    Isolator, damaged

    Doug DC982

    FTW - FOUND LOWER FORWARD ISOLATOR ALIGNMENT MARK BEYOND LIMITS NR 2 ENGINE. REMOVED FORWARD LOWER ISOLATOR. INSTALLED LOWER FORWARD ISOLATOR ON NR 2 ENGINE.…

  75. 12 Nov 2002

    Seat Track, worn

    Doug DC982

    FTW - PASSENGER SEAT TRACK LEFT INBOARD, WORN AT FS 1005-1809, 1118-1129, 1222, 1241, 1274, 1280. OUT OF LIMITS AT STATION'S 1118 TO 1129, 1241, 1274 AND…

  76. 29 May 2002

    Battery, discharged

    Doug DC982

    FOUND EMERGENCY LIGHTS INOPERATIVE IN FORWARD PAX CABIN. FOUND BATTERIES IN BATTERY PACK DEAD, INSTALLED NEW BATTERIES FOUND PACK WOULD COME ON WHEN POWER…

  77. 24 May 2002

    O-Ring, leaking

    Doug DC982

    MCO - FLT 927 - SMELL OF FUEL IN COCKPIT WHILE TAXIING AT MCO. REMOVED AND REPLACED FUEL SOLENOID O-RINGS SEALS. OPS AND LEAK CHECK NORMAL. (M)

  78. 19 May 2002

    Slide, out of position

    Doug DC982

    SJU - L1 DOOR EMERGENCY ESCAPE SLIDE PACK FELL OFF. REINSTALLED L1 EMERGENCY ESCAPE SLIDE PACK. (M)

  79. 14 May 2002

    Cam, out of adjust

    Doug DC982

    DTW - FLT 563 - SLACK IN THE CG ADJUSTMENT WHEEL OF TAKEOFF CONDITIONING COMPUTER. TAKEOFF WARNING HORN DURING INITIAL POWER UP FOR TAKEOFF TAXIED OFF OF…

  80. 23 Apr 2002

    Control Switch, malfunctioned

    Doug DC982

    FLT 262 - ACY - ELEVATOR POWER ON LIGHT STAYED ON AFTER CONTROL CHECK. REMOVED AND REPLACED ELEVATOR POWER CONTROL PSI SWITCH. (M)

  81. 17 Apr 2002

    Connector, loose

    Doug DC982

    MCO - FLT 1301 - ELEVATOR POWER ON LIGHT ILLUMINATED WOULD NOT GO OUT. TROUBLESHOT PSI SWITCH TO HAVE LOOSE CANNON PLUG, CLEANED PLUG. OPS CHECK NORMAL. (M)

  82. 5 Dec 2001

    Battery, discharged

    Doug DC982

    ACY - EMERGENCY CEILING LIGHT FROM ROW 1 TO 4 INOPERATIVE. REMOVED AND REPLACED LIGHT BATTERIES, OPS CHECK GOOD IAW MD80 MM 33-53-01. (M)

  83. 3 Dec 2001

    Switch, malfunctioned

    Doug DC982

    F/O'S PRIMARY TRIM SWITCH IAW MD80 MM 27-40-02 AND GROUND, OPS CHECKS GOOD. (M)

  84. 27 Nov 2001

    Motor, failed

    Doug DC982

    FLT 779 - LGA - PRIMARY STABILIZER TRIM STALLED, AND EXPERIENCED THERMAL SHUTDOWN TWICE ON CLIMB-OUT, AND ONCE IN LEVEL CRUISE. REMOVED AND REPLACED…

  85. 11 Oct 2001

    Wire, damaged

    Doug DC982

    DTW - FOUND L2 AND AFT CABIN EMERGENCY EXIT SIGNS INOPERATIVE. REPAIRED WIRING AT AFT BATTERY PACK. OPS CHECK NORMAL IAW MD80 MM 33-63-01. (M)

  86. 4 Sep 2001

    Power Supply, discharged

    Doug DC982

    FLL - FOUND FORWARD BATTERY POWER SUPPLY INOPERATIVE, REQUIRES REMOVED AND REPLACED WITH NO POWER ON A/C FORWARD OVERHEAD LIGHTS CAME ON. REMOVED AND REPLACED…

  87. 29 Aug 2001

    Computer, malfunctioned

    Doug DC982

    ACY - FLT 138 - SELECTING CLIMB POWER ON TRP AFTER TAKEOFF CAUSED RIGHT THROTTLE TO MOVE BACK TO CORRECT POSITION MANUALLY WORKED OK REST OF FLIGHT DFGC NR 1.…

  88. 21 Aug 2001

    Clutch, lack of lube

    Doug DC982

    FLT 678 - DTW - AUTOTHROTTLES, LEFT THROTTLE DID NOT RETARD FROM CLIMB POWER SETTING TO CRUISE POWER SETTING TWICE DURING CLIMB-OUT. WORKED FINE DURING REST…

  89. 13 Aug 2001

    Wire, broken

    Doug DC982

    DTW - BARFIELD SMOKE DETECTOR FAILS TEST. REPAIRED BROKEN WIRE AND OPS CHECKED IAW MD80 MM 26-30. (M)

  90. 31 May 2001

    Autothrust Sys, malfunctioned

    Doug DC982

    FLT 1268 - ACY - AUTO THROTTLES DISCONNECTED WITHOUT COMMAND. TRIED TO RE-ENGAGE AND WOULD NOT STAY ENGAGED. SWITCHED TO NR 2 DFGC AND CADC BOTH ON 2 AND…

  91. 21 Nov 2000

    Connector, loose

    Doug DC982

    ISLE PATH EMERGENCY LIGHTS NOT WORKING FORWARD OF ROW 8. FOUND CANNON PLUG PIN PUSHED OUT. RESEATED PIN. OPS CHECK GOOD IAW MD 80 M/M 33-50-00.

  92. 25 Feb 2000

    Connector, disconnected

    Doug DC982

    DTW - EMERGENCY TRACK LIGHTING FROM ROWS 14 THROUGH 22 IS OUT. RECONNECTED LOOSE CONNECTIONS. OPS CHECKS GOOD, NO DEFECTS NOTED AT THIS TIME AS PER 33-50-00.…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05624 Nov 2026
FCC GMRS633,27224 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,84423 Nov 2026
FAA registered aircraft319,59223 Nov 2026
FAA N-number reservations126,12623 Nov 2026
FAA dealers12,51023 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,33524 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.