N812NK
1983 McDonnell Douglas DC-9-82(MD-82) standard FAA →
reservations
earlier registrations
1 past record
- 1983
service difficulty reports
92 reports
- 2 Jul 2004
Floorboard, sheared
FTW - FOUND G1 FORWARD INBOARD MOUNT NUT PLATE SHEAREDON INSTALLATION. REMOVED FLOORBOARD AT OUTBOARD STATION 160-200. FLOORBOARD HAS EXTENSIVE DELAMINATION.…
- 29 Jun 2004
Floor Panel, corroded
FTW - FOUND MAIN CABIN STATION 1250 TO STATION 1155 LEFT SIDE INBOARD FLOOR PANEL HAS SEVERAL INSERTS CORROSION SOFT/MUSHEY EDGE FILLER IS MISSING. FABRICATED…
- 25 Jun 2004
Bracket, cracked
FTW - FOUND FORWARD PIT DOOR AFT LOWER INTERNAL EDGE BRACKET CRACKED. REMOVED CRACKED BRACKET. FABRICATED BRACKET. INSTALLED NEW BRACKET. (M)
- 24 Jun 2004
Skin, worn
FTW - FOUND R1 DOOR LOCK TO HAVE EXCESSIVE MATERIAL LOSS ON LOWER SKIN. (M)
- 23 Jun 2004
Skin, damaged
FTW - FOUND EXISTING REPAIR AT FS 427 BETWEEN LONGERONS 18 AND 20R REQUIRES TO BE REPLACED WITH DC9/MD80 SRM 53-05 FIG 105 REPAIR. INSTALLED REPAIR NO LONER…
- 23 Jun 2004
Skin, damaged
FTW - FOUND 20 INCH CREASE AT FS 617 BETWEEN LONGEORN 22 AND 23R, CREASE IS IN THE CONTROLLED RVSM AREA AND MUST BE REPAIRED. CUT OUT DAMAGED SKIN BETWEEN…
- 22 Jun 2004
Intercostal, cracked
FOUND CABIN FLOOR STATION 769-788 BL 0 INTERCOSTAL UPPER FLANGE IS CRACKED AROUND FASTENER HOLES WITH MATERIAL MISSING AT 2 LOCATIONS. REMOVED INTERCOSTAL.…
- 22 Jun 2004
Floor Panel, cracked
FTW - FOUND MAIN CABIN RIGHT INBOARD FLOOR PANEL STATION 1250-1309 HAVE CRACKS, DAMAGE ON EDGES/SEVERAL INSERTS HAVE PULLED THROUGH. FABRICATED NEW FLOOR…
- 22 Jun 2004
Floorboard, damaged
FTW - FOUND MAIN CABIN STATION 1117 TO 1174 CENTER FLOOR PANEL HAVE SOFT/MUSHEY AND DAMAGE ON EDGE. FABRICATED CABIN FLOORBOARD. (M)
- 22 Jun 2004
Floor Panel, cracked
FTW - FOUND MAIN CABIN STATION 806 TO STATION 826, FLOOR PANEL ONE INSERT DAMAGE/CRACKS ON EDGES. FABRICATED NEW FLOOR PANEL. (M)
- 21 Jun 2004
Floorboard, broken
FTW - FOUND FLOORBOARD FASTENER INSERTS MISSING, TWO EACH STATION 200-260 LBL 24-25. UPON FURTHER INVESTIGATION FLOORBOARD PANEL FOUND TO BE BROKEN.…
- 21 Jun 2004
Floorboard, broken
FOUND FLOORBOARD BROKEN STATION 200-260 LBL 24-31. FABRICATED FLOORBOARD. (M)
- 21 Jun 2004
Frame, cracked
FTW - FOUND LT WING FIXED LEADING EDGE COMPARTMENT XFS 267 TWO EACH, FRAME CRACKED. STOP DRILLED CRACKS. FABRICATED TWO REPAIR DOUBLER. INSTALLED TWO FORMER…
- 20 Jun 2004
Frame, cracked
FTW - FOUND LOWER FIXED LEADING EDGE COMPARTMENT XFS 330 LEADING EDGE FRAME CRACK. STOP DRILL CRACK AT FORMER. FABRICATED 3 AND DRILLED REPAIR FORMER.…
- 19 Jun 2004
Seat Track, corroded
FTW - FOUND RIGHT OUTBOARD SEAT TRACK STATION 200-1309 IS CORRODED AND GOUGED ALONG ENTIRE LENGTH, FS 494 IS OUT OF LIMITS. REMOVED DAMAGED SECTION OF SEAT…
- 19 Jun 2004
Seat Track, corroded
FOUND LEFT INBOARD SEAT TRACK STATION 200-1309 IS CORRODED AND GOUGED ALONG ENTIRE LENGTH. REMOVED CORROSION STATION 200-236 IS OUT OF LIMITS. MATERIAL LOSS…
- 25 Apr 2004
Strap, misinstalled
TAIL SLIDE COVER HOLD DOWN STRAPS NOT INSTALLED CORRECTLY. INSTALLED TAIL CONE EMERGENCY SLIDE COVER STRAPS CORRECTLY.
- 10 Apr 2004
Light, loose
ORD - FLT 1504 - AFT GALLEY AISLE EXIT LIGHTING TRACK CAME UP. RE-ATTACHED AFT GALLEY LUMINESCENT EXIT STRIP. (M)
- 8 Apr 2004
Sign, dislodged
EXIT SIGN AT AFT GALLEY FELL OFF ON TAKEOFF. RE-ATTACHED LUMINESCENT EXIT STRIP AT AFT GALLEY FLOOR AREA. (M)
- 30 Jan 2004
Landing Gear, malfunctioned
PBI - FLT 833 - AFTER TAKEOFF, THE NOSE GEAR FAILED TO RETRACT. CYCLED GEAR DOWN, NOSE GEAR GREEN LIGHT ON INSTANTLY. RECYCLED GEAR UP. NOSE GEAR FAILED TO…
- 28 Jan 2004
Glowstrip, loose
DTW - FLT 834 - AFT GALLEY FLOOR GLOW STRIP OFF. REINSTALLED GALLEY FLOOR AFT GLOWSTRIP. NO OTHER DEFECTS NOTED. (M)
- 26 Jan 2004
Proximity Sensor, malfunctioned
FLL - FLT 1123 - NOSE GEAR UNSAFE LIGHT WOULD NOT EXTINGUISH UPON RETRACTION. RECYCLED PER QRH, WHICH DID NOT REMEDY SITUATION. LIGHT FINALLY WENT OUT…
- 20 Jan 2004
Glowstrip, missing
MCO - FLT 1863 - FLOOR GLOW PATH STRIP MISSING BY L2 DOOR. REPLACED MISSING SAFTGLO SUPPORT FLOOR PATH STRIP. (M)
- 15 Jan 2004
Engine, flamed out
RT ENG FLAMED-OUT, AIR RETURN AT 800 TO 1000 MLS RT ENG EPR DROPPED BELOW 1.2 EPR, ARTS FIRED BASES X-TERED TO LT GENERATORS ACCOMPLISHED QRH ITEMS PULLED CVR…
- 28 Sep 2003
Conduit, out of position
LEFT MAIN RED GEAR LIGHT ON WITH LANDING GEAR HANDLE UP. QRH PROCEDURE FOLLOWED, NO CHANGE. REPOSITIONED LT MAIN GEAR UPLOCK SENSOR CONDUIT AND OPS CHECKED.…
- 14 Sep 2003
Control Unit, malfunctioned
LT ENGINE LOOP 'A' LIGHT ILLUMINATED. ACCOMPLISHED QRH PROCEDURE. REMOVED AND REPLACED CONTROL UNIT. OPS CHECK NORMAL. (M)
- 26 Aug 2003
Blade, damaged
NR 2 ENGINE 1ST STAGE FAN BLADE IS MANGLED BEYOND BLENDABLE LIMITS. REMOVED AND REPLACED TWO C-1 BLADES IAW MD-80 A/C MM REV 76 REV 76 SECTION 72-33-21.…
- 26 Aug 2003
Inlet Guide Vane, cracked
ENGINE 2-217A ESN 708450 INLET GUIDE VANE HAS ROOT AND INNER SHROUD WELD TO SHROUD CRACKED. REMOVED AND REPLACED IGV CASE. (M)
- 1 Jun 2003
Bracket, damaged
SLIDE PACK BRACKET ON R-1 DOOR WILL NOT HOLD SLIDE PACK GIRT BAR. REPOSITIONED AFT GIRT BAR HOOK ON R-1 SLIDE PACK. GIRT BAR OPERATION NORMAL. (M)
- 24 Apr 2003
Engine, smoke
AIR RETURN, ON TAKEOFF AFT CABIN FILLED WITH SMOKE. AFT LAV SMOKE ALARMS WENT OFF. RETURNED TO DTW. REMOVED AND REPLACED NR 2 ENGINE. OPS CHECK AND LEAK GOOD,…
- 2 Apr 2003
Smoke Detector, malfunctioned
CARGO FIRE DETECTION FORWARD 'B' FAIL LIGHT AND ANNUNCIATOR PANEL SMOKE DETECTOR LOOP LIGHT ILLUMINATED. REMOVED AND REPLACED CARGO COMPARTMENT SMOKE…
- 10 Mar 2003
Screw, missing
LEFT FORWARD OVERWING EMERGENCY EXIT WINDOW IS STUCK CLOSED. FORWARD SCREW ON EXIT COVER MISSING THUS JAMMING DOOR CLOSED. INSTALLED SCREW ON COVER, DOOR NOW…
- 29 Nov 2002
Ring, corroded
FTW - FOUND LEFT 346 WINDOW UPPER AFT FRAME CORRODED. REMOVED LEFT NR 46 WINDOW UPPER AFT CRACKED FRAME. LOCATED AND DRILLED NEW ORDERED WINDOW RING.…
- 27 Nov 2002
Floor Support, corroded
FTW - L2 DOOR OPENING FLOOR PANEL SUPPORT BRACKETS (2) CORRODED. FORWARD FLOOR PANEL SUPPORT BRACKET L2 DOOR FOUND TO BE OUT OF LIMITS. FABRICATED FORWARD…
- 24 Nov 2002
Attach Angle, cracked
FTW - FOUND DORSAL FIN INBOARD LEFT, RIGHT ANGLE ATTACH IS CRACKED. REMOVED LEFT AND RIGHT FIN INBOARD ATTACH ANGLES. LOCATED AND DRILLED LEFT INBOARD FIN…
- 23 Nov 2002
Seat Track, corroded
FTW - FOUND RIGHT INBOARD SEAT TRACK CORRODED AT STATION 200 AND 256. MATERIAL LOSS OUT OF LIMITS AT SEAT TRACK STATION 267. REMOVED DAMAGE AREA. FABRICATED…
- 21 Nov 2002
Door Frame, corroded
FTW - FOUND AFT CARGO JAMB BEAM HAS CORROSION STATION 1112-1249, DOOR JAMB BEAM REPAIR STRAP HAS CORROSION UNDER STRAP ON JAMB BEAM. CORRODED REMOVAL WAS…
- 21 Nov 2002
Longeron, corroded
E/E BAY STATION 180-218 L30 CORROSION IN LONGERON AROUND FASTENERS. REMOVED DAMAGED SECTION OF LONGERON AND SPLICE. INSTALLED NEW LONGERON AND SPLICE. (M)
- 21 Nov 2002
Web, cracked
FTW - FOUND PAX CABIN STATION 503, STATION 231 WEB MEMBRANE IS CRACKED. STOP DRILLED CRACK. FABRICATED DOUBLER. INSTALLED DOUBLER REPAIR. STOP DRILL CRACK AT…
- 18 Nov 2002
Intercostal, cracked
FTW - FOUND L1 DOOR UPPER MOST INTERCOSTAL BEAM (TWO) CRACKS IN LOWER RADIUS FORWARD AND AFT SIDES. REMOVED CRACKED DOOR BEAM. FORMED BEAM. INSTALLED DOOR…
- 17 Nov 2002
Stringer, cracked
FTW - AFT ACCESSORY COMPARTMENT 1474 CANT LONGERON 18L, 1 INCH CRACK ON STRINGER. STOP DRILL CRACK. FABRICATED TWO FORMER DOUBLERS. INSTALLED TWO FORMER…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Frame, corroded
FTW - FOUND FORWARD PIT HAS CORROSION AT THE FRAME STATION 541, STATION 560, 579, 636, 701, 750 AT 788, RBL 16 INCHES LBL 16 INCHES. FOUND THE AREA AT FS 541,…
- 17 Nov 2002
Door Frame, corroded
FTW - FOUND DOOR JAMB BEAM REPAIR STRAP HAS CORROSION UNDER STRAP AND ON JAMB BEAM. REMOVED DOOR JAMB BEAM TO BE OUT OF LIMITS. HOLES LOCATED AND DRILLED ON…
- 16 Nov 2002
Skin, damaged
FTW - FOUND EXISTING REPAIRS AT FS 301 AND FS 310 BETWEEN L23R AND L25R ARE TOO CLOSE TOGETHER AND REQUIRES REPAIRS TO BE COMBINED. CUT OUT DAMAGED AREA.…
- 16 Nov 2002
Floorboard, damaged
FTW - FLOORBOARD PANEL FS 1118-1184 BL0-BL23 HAS CORRODED INSERTS AND PUNCHER WITH DELAMINATION. FABRICATED NEW FLOORBOARD FS 1118-1184. (M)
- 16 Nov 2002
Support, corroded
FTW - FOUND MID PIT STATION 636 TO 693 CORROSION AT T-SUPPORT INBOARD BEAM AND ELONGATED HOLES. REMOVED THE INBOARD BEAM T-SUPPORT. LOCATED AND DRILLED NEW…
- 16 Nov 2002
Angle, corroded
FTW - FOUND MID PIT STATION 541 FORWARD BULKHEAD AFT FACE HAS CORROSION AT ANGLE LOWER ATTACH TO BULKHEAD RBL 16 INCH LBL 16 INCHES. REMOVED LOWER ANGLE.…
- 16 Nov 2002
Doubler, corroded
FTW - FOUND MID PIT HAS CORROSION AT DOUBLER RAD ALT RECEIVER 1, RAD ALT TRANSMITTER 1, RAD ALT TRANSMITTER 2, RAD ALT RECEIVER 2. THE DAMAGED TO THE RAD ALT…
- 16 Nov 2002
Skin, dented
FTW - FOUND DENTS AT STATION 200 AT LONGERONS 22-23L, 23-24L, 24-25L, DUE TO THESE DENTS CLOSE PROXIMITY TO EACH OTHER. REPAIR MUST BE ACCOMPLISHED. REWORKED…
- 16 Nov 2002
Skin, damaged
FTW - FOUND EXISTING REPAIRS AT FS 320 AND FS 330 REQUIRES TO BE COMBINED INTO A SINGLE REPAIR. REMOVED EXISTING REPAIRS AT FS 320 AND FS 330. CUT OUT…
- 16 Nov 2002
Floor Panel, damaged
FTW - FOUND CAPTAIN FLOOR PANEL NEXT TO CONTROL COLUMN HAS DELAMINATED AND BROKEN WOOD FILLER AS MARKED. LOCATED AND DRILLED NEW PANEL. (M)
- 16 Nov 2002
Intercostal, corroded
STA 1322-1338, LONGERON 22 LT INTERCOSTAL HAS CORROSION. REMOVED 2 INTERCOSTALS AT STA 1322-1338, 22L, 21L. FABRICATED 2 EA INTERCOSTAL. INSTALLED 2 EA…
- 15 Nov 2002
Intercostal, cracked
FTW - FOUND AFT PIT STATION 1287-1309 BL 0 INTERCOSTAL UPPER FLANGE CRACKED AT FASTENER HOLES. REMOVED UPPER FLANGE REPAIR ANGLE. FABRICATED ANGLE. INSTALLED…
- 15 Nov 2002
Web, cracked
FTW - FLOOR WEB CRACKED TWO PLACES BETWEEN STATION 1287-1309 RIGHT. FABRICATED DOUBLERS. UPON FURTHER EVALUATION 3 CRACKS WERE FOUND. INSTALLED DOUBLERS. (M)
- 15 Nov 2002
Splice, corroded
FTW - FOUND FORWARD CARGO FS 227 STRINGER 28L SPLICE FITTING CORRODED. REMOVED LONGERON SPLICE. LOCATED AND DRILLED NEW SPLICE. INSTALLED SPLICE. (M)
- 15 Nov 2002
Splice, corroded
FTW - FOUND FORWARD PIT FS 227 STRINGER 27L SPLICE FITTING CORRODED. REMOVED SPLICE FITTING. FORMED SPLICE. INSTALLED SPLICE. (M)
- 15 Nov 2002
Door Frame, corroded
FTW - FOUND FORWARD CARGO PIT DOOR JAMB BEAM LOWER SECTION CORRODED. REMOVED DOOR JAMB INNER PANEL. HOLES LOCATED AND DRILLED ON NEW PANEL. INSTALLED NEW…
- 15 Nov 2002
Skin, damaged
FTW - FOUND TEMP REPAIR AT STATION 474 LONGERON 30 (VHF ANT) REQUIRES ACTIONS. REMOVED EXTERNAL DOUBLER. FABRICATED INNER SKIN. FABRICATED FOUR TEE ANGLES.…
- 15 Nov 2002
Stringer, corroded
FTW - FOUND FORWARD CARGO STRINGER 28L CORRODED AT FS 218-237, 53) 237-256, 58) 275-294, 67) 330-351. STRINGER 28L B7W STATION 229 AND STATION 243 FOUND TO BE…
- 14 Nov 2002
Skin, dented
FTW - FOUND DENT RIGHT SIDE FS 605 BETWEEN LONGERONS 20R AND 21R. FABRICATED DOUBLER FOR STATION 602. INSTALLED REPAIR DOUBLER. (M)
- 14 Nov 2002
Skin, dented
FTW - FOUND DENT LEFT SIDE FUSELAGE FS 209 LONGERON 14L. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)
- 14 Nov 2002
Skin, dented
FTW - FOUND DENT RIGHT SIDE FS 353 BETWEEN LONGERON 22R AND 23R. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)
- 14 Nov 2002
Skin, dented
FTW - FOUND DENT RIGHT SIDE FS 622 BETWEEN LONGERONS 21R AND 22R. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER. (M)
- 13 Nov 2002
Seat Track, damaged
FTW - FOUND PASSENGER SEAT TRACK LEFT, OUTBOARD WORN AT FS 998-1010, GOUGE 1019, CORROSION 1037-1041, WORN 1059-1067, 1087-1098, CORROSION 1240. LEFT,…
- 13 Nov 2002
Skin, dented
FTW - FOUND DENT RIGHT SIDE FUSELAGE STATION 463 BETWEEN LONGERONS. FORMED NEW DOUBLER REPAIR. INSTALLED NEW DOUBLER REPAIR. (M)
- 12 Nov 2002
Skin, dented
FTW - FOUND DENT LEFT SIDE FS 218 BETWEEN LONGERON 15L AND 16L. DENT LEFT SIDE FUSELAGE STATION 216 BETWEEN LONGERONS 15L AND 16L. FABRICATED DOUBLER.…
- 12 Nov 2002
Seat Track, corroded
FTW - FOUND PASSENGER SEAT TRACK RIGHT OUTBOARD, GOUGE AT FS 248, 291, CORROSION AT FS 256, 277, 301, 340, 400-418, 424-447, 458-478, 492-496, 523-536,…
- 12 Nov 2002
Isolator, damaged
FTW - FOUND LOWER FORWARD ISOLATOR ALIGNMENT MARK BEYOND LIMITS NR 2 ENGINE. REMOVED FORWARD LOWER ISOLATOR. INSTALLED LOWER FORWARD ISOLATOR ON NR 2 ENGINE.…
- 12 Nov 2002
Seat Track, worn
FTW - PASSENGER SEAT TRACK LEFT INBOARD, WORN AT FS 1005-1809, 1118-1129, 1222, 1241, 1274, 1280. OUT OF LIMITS AT STATION'S 1118 TO 1129, 1241, 1274 AND…
- 29 May 2002
Battery, discharged
FOUND EMERGENCY LIGHTS INOPERATIVE IN FORWARD PAX CABIN. FOUND BATTERIES IN BATTERY PACK DEAD, INSTALLED NEW BATTERIES FOUND PACK WOULD COME ON WHEN POWER…
- 24 May 2002
O-Ring, leaking
MCO - FLT 927 - SMELL OF FUEL IN COCKPIT WHILE TAXIING AT MCO. REMOVED AND REPLACED FUEL SOLENOID O-RINGS SEALS. OPS AND LEAK CHECK NORMAL. (M)
- 19 May 2002
Slide, out of position
SJU - L1 DOOR EMERGENCY ESCAPE SLIDE PACK FELL OFF. REINSTALLED L1 EMERGENCY ESCAPE SLIDE PACK. (M)
- 14 May 2002
Cam, out of adjust
DTW - FLT 563 - SLACK IN THE CG ADJUSTMENT WHEEL OF TAKEOFF CONDITIONING COMPUTER. TAKEOFF WARNING HORN DURING INITIAL POWER UP FOR TAKEOFF TAXIED OFF OF…
- 23 Apr 2002
Control Switch, malfunctioned
FLT 262 - ACY - ELEVATOR POWER ON LIGHT STAYED ON AFTER CONTROL CHECK. REMOVED AND REPLACED ELEVATOR POWER CONTROL PSI SWITCH. (M)
- 17 Apr 2002
Connector, loose
MCO - FLT 1301 - ELEVATOR POWER ON LIGHT ILLUMINATED WOULD NOT GO OUT. TROUBLESHOT PSI SWITCH TO HAVE LOOSE CANNON PLUG, CLEANED PLUG. OPS CHECK NORMAL. (M)
- 5 Dec 2001
Battery, discharged
ACY - EMERGENCY CEILING LIGHT FROM ROW 1 TO 4 INOPERATIVE. REMOVED AND REPLACED LIGHT BATTERIES, OPS CHECK GOOD IAW MD80 MM 33-53-01. (M)
- 3 Dec 2001
Switch, malfunctioned
F/O'S PRIMARY TRIM SWITCH IAW MD80 MM 27-40-02 AND GROUND, OPS CHECKS GOOD. (M)
- 27 Nov 2001
Motor, failed
FLT 779 - LGA - PRIMARY STABILIZER TRIM STALLED, AND EXPERIENCED THERMAL SHUTDOWN TWICE ON CLIMB-OUT, AND ONCE IN LEVEL CRUISE. REMOVED AND REPLACED…
- 11 Oct 2001
Wire, damaged
DTW - FOUND L2 AND AFT CABIN EMERGENCY EXIT SIGNS INOPERATIVE. REPAIRED WIRING AT AFT BATTERY PACK. OPS CHECK NORMAL IAW MD80 MM 33-63-01. (M)
- 4 Sep 2001
Power Supply, discharged
FLL - FOUND FORWARD BATTERY POWER SUPPLY INOPERATIVE, REQUIRES REMOVED AND REPLACED WITH NO POWER ON A/C FORWARD OVERHEAD LIGHTS CAME ON. REMOVED AND REPLACED…
- 29 Aug 2001
Computer, malfunctioned
ACY - FLT 138 - SELECTING CLIMB POWER ON TRP AFTER TAKEOFF CAUSED RIGHT THROTTLE TO MOVE BACK TO CORRECT POSITION MANUALLY WORKED OK REST OF FLIGHT DFGC NR 1.…
- 21 Aug 2001
Clutch, lack of lube
FLT 678 - DTW - AUTOTHROTTLES, LEFT THROTTLE DID NOT RETARD FROM CLIMB POWER SETTING TO CRUISE POWER SETTING TWICE DURING CLIMB-OUT. WORKED FINE DURING REST…
- 13 Aug 2001
Wire, broken
DTW - BARFIELD SMOKE DETECTOR FAILS TEST. REPAIRED BROKEN WIRE AND OPS CHECKED IAW MD80 MM 26-30. (M)
- 31 May 2001
Autothrust Sys, malfunctioned
FLT 1268 - ACY - AUTO THROTTLES DISCONNECTED WITHOUT COMMAND. TRIED TO RE-ENGAGE AND WOULD NOT STAY ENGAGED. SWITCHED TO NR 2 DFGC AND CADC BOTH ON 2 AND…
- 21 Nov 2000
Connector, loose
ISLE PATH EMERGENCY LIGHTS NOT WORKING FORWARD OF ROW 8. FOUND CANNON PLUG PIN PUSHED OUT. RESEATED PIN. OPS CHECK GOOD IAW MD 80 M/M 33-50-00.
- 25 Feb 2000
Connector, disconnected
DTW - EMERGENCY TRACK LIGHTING FROM ROWS 14 THROUGH 22 IS OUT. RECONNECTED LOOSE CONNECTIONS. OPS CHECKS GOOD, NO DEFECTS NOTED AT THIS TIME AS PER 33-50-00.…