N809EX
1991 Boeing DHC-8-102 standard FAA →
reservations
earlier registrations
1 past record
- 1991
service difficulty reports
113 reports
- 8 Oct 2017
Light, inoperative
FLOOR EMERGENCY LIGHT AT SEAT 7DF INOPERATIVE. R & R THE EMERGENCY LIGHT.
- 25 May 2017
Seal, leaking
NR 2 OIL PRESSURE FLUCTUATING BETWEEN 55 AND 50 PSI INFLIGHT AND WARNING LIGHT BLINKING. INSPECTED AND FOUND FRONT INLET CASE COVER PLATE LEAKING. R & R THE…
- 22 May 2017
Bulb, inoperative
EMERGENCY LIGHT BULB INOPERATIVE. R & R THE BULB.
- 3 Apr 2017
Light, inoperative
FLOOR EMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 1 AND 6. R & R THE EMERENCY LIGHTS.
- 19 Mar 2017
Bulb, inoperative
RIGHT FWD EMERGENCY EGRESS LIGHT INOPERATIVE. R & R THE BULB.
- 3 Oct 2016
Battery, inoperative
FORWARD EMERGENCY EXIT LIGHT, CEILING LIGHT AND CENTER CABIN EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY BASE.OPS CHECKED…
- 18 Aug 2016
Pseu, failed
NOTICED ELECTRICAL ODOR IN FLIGHT DECK AND CABIN. INSPECTED AND FOUND PSEU HAD OVERHEAT AND FAILED. R & R PSEU IAW 32-61-50, OPS CK GOOD, OK FOR SERVICE.
- 14 Jun 2016
Handset, malfunctioned
F/A PANEL EMERGENCY CALL BUTTON ILLUMINATES AND COMMUNICATIONS IS INTERMITTENT. R & R F/A CONTROL PANEL NO FIX. REINSTALLED ORIGINAL PANEL. R & R HANDSET AND…
- 5 May 2016
Bulb, inoperative
RED FLOOR EMERGENCY LIGHT BULB AFT OF FWD LEG OF SEATS 5DF INOPERATIVE. R & R BULB .
- 5 May 2016
Light, inoperative
4TH RED FLOOR EMERGENCY LIGHT OF FWD MOST OF RED LIGHTS INOPERATIVE. REMOVED FWD MOST SECTION OF EMERGENCY FLOOR LIGHT COVER. R & R BULB FOR 4TH RED EMERGENCY…
- 20 Apr 2016
Unknown, odor
INTERMITTENT ODOR IN FLIGHT DECK DURING FLIGHT. RUBBER LIKE ODOR IAW CREW. RAN BOTH ENGINES WITH BLEEDS SELECTED ON, NO ABNORMAL ODORS NOTED AT THIS TIME OK…
- 19 Apr 2016
Unknown, odor
AT 3000 FT ON DESCENT A STRONG RUBBER ODOR PRESENT IN FLIGHT DECK, NEAR FLIGHT DECK DOOR. BLEEDS SELECTED OFF NO CHANGE. NO SMOKE VISIBLE, AVIONICS COOLING…
- 14 Apr 2016
Warning Horn, unknown
FLAPS OUT OF 5 DEG ARC, T/O WARNING SOUNDED ON T/O ROLL. R & R FLAP POSITION INDICATOR GROUND RUN, OPS CHECKED GOOD.
- 13 Apr 2016
Inverter, failed
CREW HEARD CIRCUIT BREAKER TRIP WITH ASSOCIATED SMOKE FROM PANEL. CAPTAIN`S FLIGHT INSTUMENTS AND TRANSPONDER F-8/F-9. FLT DIVERTED. R & R PRIMARY INVERTER,…
- 19 Feb 2016
Timer, inoperative
RANDOM BOOTS WILL NOT INFLATE IN SEQUENCE ON OCCASION. THREE BOOTS ILLUMINATED AT THE SAME TIME. LIGHTS TESTED NORMAL. PRIMARILY IN FAST. R & R DEICE TIMER.…
- 7 Dec 2015
Bulb, inoperative
EMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R BULBS AT ROW 1 EMERGENCY LIGHT. OPS CHECKED GOOD.
- 23 Oct 2015
Wire, open
LT ELEVATOR HORN HEAT CONTROL LIGHT ON IN FLIGHT. FOUND OPEN WIRE BETWEEN PLUGS 3015-J5 AND 3015-J3. R & R WIRES. OPS GOOD.
- 14 Oct 2015
Inverter, smoke
SMOKE EMANATING FROM LT CIRCUIT BREAKER PANEL. INSPECTED PRIMARY INVERTER CIRCUIT BREAKER PANEL AND ASSOCIATED COMPONENTS. SWAPPED TO AUXILIARY INVERTER,…
- 11 Mar 2015
Bulb, inoperative
FORWARD EMERGENCY EGRESS LIGHT IS DIM ON RIGHT SIDE. R & R BULB. OPS CHECKED GOOD.
- 11 Mar 2015
Battery Pack, inoperative
MULTIPLE EMERGENCY LIGHTS ARE OUT IN MID CABIN EGRESS LIGHT, AFT CEILING AND AISLE LIGHTS. R & R ALL EMERGENCY LIGHT BATTERIES IAW WC 33-50-05R, 33-50-03R.…
- 9 Mar 2015
Battery Pack, inoperative
AFT CEILING EMERGENCY LIGHT IS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY 3351-PS4. OPS CHECKED GOOD.
- 16 Feb 2015
Display, inoperative
DURING TAKEOFF, WEATHER RADAR SCREEN WENT BLANK, TCAS OFF MESSAGE AND FDR CAUTION LIGHT ILLUMINATED. SUSPECT RT TRU FAILURE. LOAD AT .07 POWERED DOWN AND…
- 13 Feb 2015
Switch, inoperative
EMERGENCY LIGHT SWITCH ON F/A PANEL IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.
- 5 Feb 2015
Valve, inoperative
NR 1 ENGINE INTAKE BOOT DOES NOT APPEAR TO INFLATE WITH LT NR 3 WING BOOT ADVISORY LIGHT NO ILLUMINATING. R & R DISTRIBUTOR VALVE & PRESSURE SWITCHES IN REF…
- 30 Jan 2015
Window, burned
EVIDENCE OF HEATING ELEMENT BURNED ON CAPTAIN'S WINDOW. VISIBILITY WAS OBSCURED WITH HEAT APPLIED. REPLACED CAPTAINS SIDE WINDOW REF W/C 56-00-01R.
- 29 Oct 2014
Bulb, inoperative
EMERGENCY LIGHT ON RIGHT SIDE BURNED OUT. R & R THE BULB. OPS CHECKED GOOD. OK FOR SERVICE.
- 17 Oct 2014
Bulb, inoperative
EMERGENCY SIDEWALL LIGHT IS INOPERATIVE AT ROW 1DF. R & R BULB. OPS CHECKED GOOD.
- 26 Sep 2014
Pcu, unknown
DURING TAKEOFF ROLL, ADJUSTED NR 1 PCU SPEEDER SCREW COUNTER CLOCKWISE APPROX. .2500 TURN IAW MM 61-22-00. GROUND RAN ACFT. OPS CHECKED GOOD IAW RUN UP MANUAL.
- 19 Sep 2014
Apu, smoke
WHILE APU IS RUNNING WITH BLEEDS OFF, NOTICED WHITE SMOKE COMING FROM VENT, FROM UNDER APU EXHAUST. AUXILIARY POWER UNIT COMPLIED WITH MAINTENANCE PROCEDURES.
- 30 Jul 2014
Bulb, inoperative
FORWARD EMERGENCY EXIT SIDEWALL LIGHT HAS ONE BULB INOPERATIVE. R & R BULB. OPS CHECKED GOOD.
- 4 Jun 2014
Bulb, inoperative
F/A'S EMERGENCY LIGHT SWITCH BACKLIGHTING IS INOPERATIVE IN NORM POSITION. R & R BULB. OPS CHECKED GOOD.
- 14 May 2014
Light, inoperative
RED FLOOR EMERGENCY LIGHT IS INOPERATIVE. R & R EMERGENCY LIGHT. OPS CHECKED GOOD.
- 12 May 2014
Unknown, odor
ODOR IN CABIN, OPERATED ENGINE BLEEDS IN VARIOUS MODES. NO ODOR.
- 20 Jan 2014
Oil System, leaking
DURING TAKEOFF ROLL, NR 2 OIL PRESSURE ADVISORY LIGHT ILLUMINATED. SHUTDOWN ENGINE AND RETURNED TO GATE. LOWER COWL AND FOUND OIL DRIPPING FROM FORWARD END…
- 23 Dec 2013
Warning Horn, false activation
BETA LOCKOUT HORN CAME ON AFTER 50 FEET CONTINUOUSLY. RETURN TO FIELD, FUNCTION CHECKED SYSTEM. OPS CHECKED OK IAW 61-20-10.
- 6 Dec 2013
Angle, cracked
CRACKED ANGLE ON FORWARD SIDE OF NR 2 NACELLE HORSE COLLAR ABOVE OTBD BOLT. COMPLIED WITH EO8-54-13-0677.
- 6 Dec 2013
Skin, damaged
INBD SIDE OF NR 2 NACELLE HAS SEVERAL RIVET HEADS WORN AT LOWER FWD CORNER OF SKIN. REMOVED RIVETS AND INSTALLED PATH ON INBD FORWARD SIDE SKIN OF NR 2…
- 6 Dec 2013
Threshold, corroded
PAX DOOR THRESHOLD MEMBER CORRODED. R & R PAX DOOR THRESHOLD ASSY IAW DWG 85321241.
- 6 Dec 2013
Seat Track, corroded
CORROSION ON RT FORWARD SEAT TRACK IN AREA OF LAVATORY AND GALLEY. REPAIRED RT SEAT TRACK IAW RD8-53-3074.
- 25 Oct 2013
Monitor, faulted
NR 1 AC GENERATOR SHOWING NO VOLTAGE ON PHASE A OR B IN FLIGHT. FOUND ACFT POWER MONITOR AT FAULT. R & R ACFT POWER MONITOR. RAN ACFT, OPS CHECKED GOOD IAW MM…
- 9 Aug 2013
Indicator, inoperative
STANDBY ATTITUDE INDICATOR WILL NOT CAGE AND SHOWS INVERTED. R & R STANDBY INDICATOR IAW MM 34-22-01. OK FOR SERVICE.
- 17 Jun 2013
Bulb, failed
F/A EMERGENCY LIGHT ON/OFF SWITCH IS OUT. REMOVED SWITCH, R & R BULB, REINSTALLED FILLER PANEL. OPS CHECKED GOOD.
- 17 Jun 2013
Bulb, failed
EMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 4. R & R BULB AT ROW 4. OPS CHECKED GOOD.
- 7 Jun 2013
Bulb, inoperative
RT FUSELAGE MOUNTED AFT EMERGENCY LIGHT IS DIM. REMOVED LENS, R & R BULB. REINSTALLED LENS, OPS CHECKED GOOD.
- 25 Jan 2013
Control Cable, out of adjust
DURING DESCENT ACFT ENCOUNTERED MODERATE WIND SHEAR CAUSING ACFT TO EXCEED 260 KNOTS FOR 3 SECONDS. NO LOSS OF CONTROL JUST MODERATE BUFFETING. CHECKED CABLE…
- 28 Dec 2012
Socket, damaged
CENTER ISLE LIGHT AT 1DF STARTS TO SMOKE. CIRCUIT BREAKERS S1, S2 AND R2 WERE PULLED AND COLLARED.
- 3 Dec 2012
Windscreen, smoke
IN FLIGHT, LT WINDSHIELD PRODUCED SMOKE AND WAS THEN TURNED OFF. HAD NO ASSOCIATED CAUTION LIGHTS. R & R CAPTAIN'S WINDSCREEN IAW WC 56-00-00R. OPS AND LEAKED…
- 26 Oct 2012
Bulb, failed
EMERGENCY FLOOR PATH LIGHT, THIRD FROM FRONT IS INOPERATIVE. R & R BULB FOR FLOOR EMERGENCY PATH LIGHT, 3RD FRONT FRONT. OPS CHECKED GOOD.
- 16 Mar 2012
Line, leaking
NR 2 HYD QTY DROP TO .5 QT IN FLIGHT, NR 2 ISOLATION VALVE LIGHT ILLUMINATED. INSPECTED AND FOUND HYD LINE LEAKING BEHIND NR 1 GRAVEL GUARD. INSTALLED TEMP…
- 9 Mar 2012
Angle, cracked
CRACKS NOTED ON NR 2 NACELLE AFT FIREWALL. REMOVED ANGLE, PARTIALLY DRILLED ANGLE TO EXISTING FIREWALL STRUCTURE. INSTALLED ANGLE IAW DWG 85410224 AND SRM…
- 9 Mar 2012
Firewall, cracked
RADIUS CRACK NOTED ON NR 2 NACELLE AFT FIREWALL. REPAIRED IAW RD 8-54-1565. COMPLIED WITH HFEC INSP AFTER REMOVING DAMAGE. NO CRACKS NOTED.
- 9 Mar 2012
Shroud, cracked
AFT NACELLE FIREWALL JET PIPE SHROUD ABOVE THE JET PIPE IS CRACKED AT THE 10 O'CLOCK AND 11 O'CLOCK POSITION. REMOVED NACELLE ANGLE. LOCATED, DRILLED ANGLE.…
- 7 Mar 2012
Battery, failed
LT FUSELAGE FORWARD EMERGENCY EGRESS LIGHT IS INOPERATIVE. R & R BATTERY IAW MM 33-51-00. OPS CHECKED GOOD.
- 7 Mar 2012
Lamp, inoperative
EMERGENCY CEILING LIGHT AT ROW 3 IS INOPERATIVE. R & R CEILING EMERGENCY LAMP AT ROW 3. OPS CHECKED GOOD.
- 21 Nov 2011
Bulb, failed
EMERGENCY FLOOR PATH LIGHT INOPERATIVE AT ROW 4DF. R & R BULB IAW MM 33-51-11.
- 21 Nov 2011
Actuator, cracked
NR 1 HYD ISOLATION LIGHT ILLUMINATED ALONG WITH INBD ROLL SPOILER HYD CAUTION LIGHT. NR 1 HYD QUANTITY AT 1.1. FOUND BACK SIDE OF ACTUATOR CRACKED. R & R…
- 16 Oct 2011
Bulb, burned out
ROW 1 RED FLOOR EMERGENCY LIGHT IS BURNED OUT. R & R ROW 1 FLOOR EMEERGENCY LIGHT BULB AS REQUIRED. OPS CHECKED GOOD.
- 22 Sep 2011
Wire, broken
EMERGENCY LIGHT AT ROW 1DF NOT WORKING (3RD 1 FROM FRONT) FOUND BROKEN WIRE SPLICE, R & R WITH NEW SPLICE. OPS CHECKED GOOD.
- 7 Aug 2011
Bracket, corroded
PAX DOOR STAIR ASSY VERTICAL SUPPORT, FORWARD OTBD AND INBD BRACKET HAS CORROSION ON IT. REMOVED BOTH BRACKETS, INSTALLED NEW BRACKETS IAW DWG 85210004.
- 29 Jul 2011
Bracket, cracked
FORWARD UPPER PAX DOOR SKIN TO STEP ATTACH POINT IS CRACKED ON STAIR ASSY. REMOVED OLD BRACKET. INSTALLED NEW BRACKET IAW DWG 85210004.
- 28 Jul 2011
Seat Track, corroded
RT SIDE INBD SEAT RAIL HAS MINOR CORROSION AROUND LAV MOUNTING HOLES. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-4698. PERFORMED HFEC INSP, NO CRACKS…
- 28 Jul 2011
Seat Track, corroded
LT SIDE INBD SEAT RAIL SEVERLY CORRODED AT X200 TO X205. CUTOUT CORRODED SET RAIL SECTION IAW RD8-53-3074, SPLICED LT INBD SEAT RAIL IAW RD8-53-3074 AND DWG…
- 28 Jul 2011
Seat Track, corroded
LIGHT INBD SEAT RAIL HAS FRETTING CORROSION FROM FLOOR PANELS AT X224 TO X312. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1339 AFT OF STA X262. PERFORMED…
- 28 Jul 2011
Threshold, corroded
PAX DOOR THRESHOLD PANEL AREA CORRODED. REMOVED PAX DOOR THRESHOLD ASSEMBLY. INSTALLED NEW THRESHOLD ASSEMBLY IAW DWG 85321241.
- 28 Jul 2011
Seat Track, corroded
LT INBD SEAT RAIL HAS MINOR CORROSION AT LOCATIONS X345, X372. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1339. COMPLIED WITH HFEC INSP, NO DEFECTS NOTED.
- 28 Jul 2011
Seat Track, corroded
LEFT OTBD SEAT RAIL HAS MINOR CORROSION. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1342 AND RD8-53-3644. PERFORMED HFEC INSP. NO CRACKS FOUND.
- 28 Jul 2011
Seat Track, corroded
RT OTBD SEAT RAIL HAS MINOR CORROSION AT LOCATION X240, X264, X290, X328 AND X342. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1342. PERFORMED HFEC. NO…
- 30 Mar 2010
Switch, out of adjust
TAKEOFF WARNING HORN SOUNDED ON TAKEOFF ROLL AT APPROXIMATELY 60 KNOTS. ADJUSTED NR 1 CONDITION LEVER MICRO SWITCH AND PERFORMED WORKCARD 31-50-00Q.…
- 3 Mar 2010
Anti-Ice System, failed
IN FLIGHT FIRST OFFICERS WINDSHIELD LOST POWER, NO LOADS. FOUND 3041 K6 INTERMITTENT CYCLED NORMALLY 2 OR 3 TIMES, THEN FAILED. REPLACED K6 OM FIRST OFFICER'S…
- 27 Nov 2009
Bulb, inoperative
ROW 1 FLOOR EMERGENCY LIGHTS HAS ONE LAMP NOT WORKING. REMOVE AND REPLACE BULB ON ROW 1 FLOOR EMERGENCY LIGHT. REF AMM 33-51-11.
- 19 Nov 2009
Engine, malfunctioned
DURING CLIMB OUT NR 1 ENG TORQUE FLUCTUATED FROM 90 PERCENT TO 50 PERCENT THEN BACK TO 90 PERCENT WITH NO ASSOCIATED CAUTION LIGHTS. INSPECTED AND FOUND C/B…
- 6 Nov 2009
Line, leaking
AT 8,000 FT. DESCENDING FOR AIRPORT, NR 1 RUDDER ISO VALVE C/L AND ROLL SPOILER INBD HYD C/L ILLUMINATED. NR 1 HYD QTY INDICATION 1.2 QUARTS AND NACELLE GAUGE…
- 17 Apr 2009
Light, inoperative
FORWARD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED FORWARD EMERGENCY LIGHTING ON RIGHT FUSELAGE IAW 33-51-00-08. NO FIX. RE-ATTACHED BULB CONNECTION…
- 13 Dec 2008
Psu, smoke
PSU AT ROW 4 DF SMOKED. PERFORM HIDDEN DAMAGE INSPECTION, DEACTIVATED UNIT PER SP 23.3
- 12 Aug 2008
Light, malfunctioned
EMERGENCY LIGHTS FLASHED OFF AND ON DURING TOUCHDOWN. PILOT REPORTED TO MAINTENANCE. PERFORMED EMERGENCY LIGHTS CHECK PER WORK CARD 33-50-03. OPS CHECK GOOD.…
- 27 May 2008
Light, broken
EMERGENCY LIGHT AT 4DF ON SIDEWALL IS BROKE. REPLACED EMERGENCY EXIT LIGHT, OPS CHECK GOOD.
- 10 Apr 2008
Oil System, low
OIL SMELL IN CABIN. APU BLEED AIR ON. APU WAS FOUND TO BE LOW ON OIL.
- 2 Dec 2007
Light, broken
FLOOR LEVEL EMERGENCY LIGHTING AT ROW 4 IS BROKEN. REINSTALLED ONE RED EMERGENCY FLOOR LIGHT CAPTION. OPERATIONAL CHECK GOOD.
- 20 Aug 2007
Radar, inoperative
FLIGHT 4353 MDT/PHL RETURNED TO MDT DUE TO THE WX RADAR WENT INOP. DUE TO WEATHER EN ROUTE THE FLIGHT COULD NOT CONTINUE. THE FLIGHT RETURNED TO MDT WITHOUT…
- 30 May 2007
Diode, active
AFTER GEAR RETRACTION RECEIVED AN AMBER LEFT GEAR DOOR LIGHT. CYCLED GEAR RESULTING IN LEFT GEAR DOOR LIGHT ILLUMINATED MOMENTARY, THEN EXTINGUISHED. THEN…
- 28 May 2007
Pseu, unknown
AFTER GEAR RETRACTION GOT AN AMBER LEFT GEAR DOOR LIGHT FOLLOWED BY A CLUNKING NOISE AND FLASHING GEAR INOP CAUTION LIGHT. ACFT DIVERTED TO ROA AND SWAPPED…
- 21 Apr 2007
Windscreen, cracked
AIRCRAFT DEPARTED DCA, ON CLIMBOUT, THE CREW HEARD A CRACKING NOISE COMING FROM THE CAPTAIN'S SIDE WINDSHIELD. LEVELED OFF AT 5000 FT AND THE NOISE WENT AWAY.…
- 8 May 2006
Ecu, failed
ON CLIMBOUT NR 1 ENGINE SURGED 10 TO 15 PERCENT TQ. ALSO NR 1 ENGINE WOULD NOT GO TO FLIGHT IDLE. REMOVED AND REPLACED NR 1 ECU GROUND RAN AND TRIMMED BOTH…
- 21 Oct 2004
Strut, cracked
DURING MAINTENANCE MIDDLETOWN, IT WAS DISCOVERED THAT AIRCRAFT 809EX HAD A 7 INCH CRACK FROM THE TOP AFT CENTER EDGE OF NOSE LANDING GEAR STRUT BODY DOWNWARD.…
- 28 Sep 2004
Warning Horn, malfunctioned
FLIGHT NR 4082 REPORTED HAVING THEIR BETA WARNING HORN SOUND WITH LOSS OF NORMAL BRAKING WHEN POWER LEVERS WERE SELECTED BELOW FLIGHT IDLE DURING GROUND…
- 15 Apr 2004
Skin, damaged
MAINTENANCE REPORTED A HOLE IN FUSELAGE AFT OF AIRSTAIR DOOR AT STATION 264.THE HOLE WAS REPAIRED PER CALLAHAN RD CAS-AAL170, WHICH REQUIRED THE DAMAGE BE…
- 7 Mar 2004
Regulator Valve, faulty
FLIGHT 3996 HAD TO RETURN TO FIELD DUE TO HAVING THE NR 2 RUDDER HYDRAULIC, RUDDER PRESSURE, AND RUDDER FULL PRESSURE LIGHTS ILLUMINATE AFTER TAKEOFF.…
- 11 Feb 2004
Relay, faulty
AIRCRAFT APU HAS A HISTORY OF THE FIRE FAULT AND CHECK FIRE DETECT LIGHTS ILLUMINATING AFTER SHUTTING DOWN THE APU. MAINTENANCE HAS COMPLIED WITH SEVERAL…
- 10 Nov 2003
Sill, damaged
WHILE AIRCRAFT 809EX WAS IN ROUTINE MAINTENANCE, IT WAS FOUND THAT THE BAGGAGE DOOR UPPER SILL HAD BEEN DAMAGED FROM THE BAGGAGE DOOR HANDLE COMING IN CONTACT…
- 31 Mar 2003
Angle, cracked
DURING ROUTINE MAINTENANCE VISIT WHILE PERFORMING A INSPECTION TASK 5340/01 NOSE LANDING GEAR WELL RT ZEE MEMBER AT STATION X97, NOSE LANDING GEAR WELL…
- 20 Apr 2002
Connector, disconnected
DURING ROUTINE MAINTENANCE VISIT CENTER AISLE EMERGENCY LIGHT ON CEILING FOUND INOPERATIVE. CANNON PLUG FOUND TO BE DISCONNECTED IN CEILING. CANNON PLUG…
- 9 Mar 2002
Windshield, cracked
MDT-BOS. FLIGHT 3715. CREW REPORTED DURING CRUISE FLIGHT 20 MI FROM MDT OUTER LAYER OF CAPTAINS WINDSHIELD SHATTERED. AIRCRAFT RETURNED TO MDT FOR REPAIRS.…
- 29 Jan 2002
Spring, broken
DURING A CHECK INSPECTION RIGHT MAIN LANDING GEAR UPLOCK HOOK FOUND TO HAVE ONE BROKEN RETRACTION SPRING. SPRING WAS REPLACED IN ACCORDANCE WITH MESSIER DOWTY…
- 20 Nov 2001
Link, worn
MDT- CREW REPORTED NOSE WHEEL SHIMMY ON LANDING ROLL OUT. MAINTENANCE REPLACED THE NOSE LANDING GEAR SHOCK STRUT PISTON CAP, LINK , UPPER AND LOWER PINS. ALSO…
- 8 Oct 2001
Windshield, cracked
BOS-ABE FLIGHT#3898. WHILE ENROUTE TO ABE @ 14,000 FT CAPTAIN SIDE WINDOW CRACKED. FLIGHT DIVERTED TO BGM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED…
- 31 Aug 2001
Rivet, loose
DURING FLEET INSPECTION FOR NACELLE RIVETS BEING LOOSE AND MISSING, ONE RIVET FOUND MISSING AND ONE FOUND PULLING THROUGH ON LEFT NACELLE OUTBOARD END PLATE…
- 14 Jul 2001
Pressure Panel, cracked
DURING ROUTING MAINTENANCE VISIT RIGHT SIDE NOSE COMPARTMENT FLOOR CRACKED. CRACK REPAIRED IN ACCORDANCE WITH DEHAVILLAND REPAIR DRAWING RD 8-53-3893.…
- 28 Jan 2000
Windshield, cracked
IN CRUISE FLIGHT AT 17,000 FEET THE CAPTAIN SIDE WINDOW CRACKED. CREW DESCENDED AND LANDED AT AVP WITHOUT INCIDENT.
- 12 Jan 2000
Trim, frozen
BUF-BWI - FLIGHT 3610 RETURNED TO BUF - DURING CRUISE ATTEMPTED TO DESCEND USING THE AUTO PILOT. CREW RECEIVED A MISTRIM LIGHT AND TURNED OFF AUTO PILOT.…
- 8 Jun 1999
Skin, cracked
BGM-DURING PERFORMANCE OF AN A1 INSPECTION THE TRAILING RUDDER WAS FOUND CRACKED IN TWO PLACES. MAINTENANCE PERFORMED REPAIRS IAW BOMBARDIER RD8-55-158.
- 15 Mar 1998
Bulb, failed
FLIGHT ATTENDANTS EMERGENCY LIGHT SWITCH INTERNAL LAMP INOPERATIVE. REMOVED AND REPLACED BULB. OPERATIONAL TEST NORMAL. A/C RETURNED TO SERVICE. (M)
- 13 Mar 1998
Light, failed
COCKPIT OVERHEAD PORTABLE EMERGENCY LIGHT REMAINS ILLUMINATED WHEN POWER IS SHUT OFF. REMOVED AND REPLACED COCKPIT OVERHEAD PORTABLE EMERGENCY LIGHT ASSEMBLY…
- 8 Jan 1998
Wire, failed
FORWARD CENTER AISLE CABIN FLOOR EMERGENCY PROXIMITY LIGHTS INOPERATIVE. REPAIRED FORWARD CENTER AISLE FLOOR EMERGENCY PROXIMITY LIGHTING SYSTEM WIRING.…
- 30 Nov 1997
Bulbs, failed
THREE FLOOR EMERGENCY LIGHTS INOPERATIVE. REPLACED BURNED BULBS, SYSTEM CHECKED GOOD. A/C RETURNED TO SERVICE. (M)
- 6 Nov 1997
Valve, failed
RIGHT ENGINE OIL TEMP REACHED 113 DEGREES AND WAS SLOWLY CLIMBING. MADE PRECAUTIONARY DIVERSION INTO BGM. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE…
- 5 Nov 1997
Light, loose
ROW ONE EMERGENCY EXIT LIGHT DETACHED FROM WALL. RESECURED EMERGENCY LIGHT. OPERATIONAL TEST NORMAL. A/C RETURNED TO SERVICE. (M)
- 16 Aug 1997
Light, cracked
LEFT MID CABIN, LOWER EMERGENCY EXIT LIGHT ASSEMBLY CRACKED. REMOVED AND REPLACED EMERGENCY LIGHT ASSY. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE. (M)
- 2 Aug 1997
Wire, broken
THREE EMERGENCY FLOOR PATH LIGHTS INOPERATIVE. REPAIRED OPEN CIRCUIT UNDER FLOOR PANEL. OPERATIONAL CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE. (M)
- 19 Jun 1997
Cover, missing
EMERGENCY EXIT LIGHT COVER MISSING IN ROW 4F, RT SIDE. INSTALLED NEW ASSEMBLY. AIRCRAFT RETURNED TO SERVICE. (M)
- 12 Dec 1996
Connector, failed
NR 1 ENGINE FAILED WHEN ECU SELECTED TO MANUAL. FOUND LEFT ECU WING ROOT CANNON PLUG 9811-P13 WET, BACK SHEEL FULL OF WATER AND DE-ICE FLUID. CLEANED, DRIED…
- 15 Nov 1996
Engine, failed
DURING CRUISE FLIGHT, THE CREW NOTICED A STRONG ODOR OF SMOKE OR OIL COMING FROM THE BLEED SYSTEM. A/C MADE AN EMERGENCY LANDING IN BOS. MAINTENANCE PERFORMED…
- 13 Dec 1994
Battery, discharged
RT AFT EMERGENCY EXIT LIGHT WILL NOT ILLUMINATE WHEN EMERGENCY LIGHTS ARE SELECTED ON. REMOVED AND REPLACED NR 4 AND NR 6 EMERGENCY LIGHT BATTERIES.…
- 13 Dec 1994
Battery, discharged
RT AFT EMERGENCY EXIT LIGHT WILL NOT ILLUMINATE WHEN EMERGENCY LIGHTS ARE SELECTED ON. REMOVED AND REPLACED NR 4 AND NR 6 EMERGENCY LIGHT BATTERIES.…