N806MH
2004 Eurocopter EC 130 B4 standard FAA →
registration
- 2004
service difficulty reports
10 reports
- 4 Aug 2008
Arm, loose
DURING ROUTINE INSPECTION A STAR ARM END BUSHING WAS FOUND LOOSE. STARFLEX REMOVED FOR REPAIR AND SERVICEABLE STARFLEX INSTALLED. THIS IS A VERY COMMON…
- 23 Jun 2008
Fitting, cracked
DURING ROUTINE INSP, FITTING WAS FOUND CRACKED IN EXCESS OF 2 INCHES FROM MOUNTING FLANGE EDGE THROUGH ONE SCREW BORE HOLE. THIS IS A COMMON FAILURE FOR THIS…
- 12 Jun 2008
Relay, failed
DURING ROUTINE OPERATIONS THE LANDING LIGHT WOULD INTERMITTENTLY NOT STOP WORKING WITH THE SELECTOR SWITCH IN THE OFF POSITION. CYCLING THE SWITCH SEVERAL…
- 12 May 2008
Starflex, cracked
(REF 0501083833) DURING ROUTINE INSP, ADHESIVE BEAD FOR A STAR ARM END BUSHING WAS FOUND CRACKED. FURTHER EXAMINATION UTILIZING A SOAP WATER DETECTION METHOD…
- 12 May 2008
Potentiometer, failed
A FAULT CODE WAS GENERATED ON SHUTDOWN INDICATING A DEFECT OF COLLECTIVE POTENTIOMETER. A NEW PART WAS INSTALLED, NO FURTHER FAULT WAS DETECTED. THIS IS…
- 24 Mar 2008
Potentiometer, defective
FAILURE CODE AT SHUTDOWN INDICATED A FAULT WITH THE COLLECTIVE POTENTIOMETER. INSTALLED NEW POTENTIOMETER AND NO FURTHER PROBLEM NOTED. THIS IS A VERY COMMON…
- 8 Jan 2008
Potentiometer, failed
PILOT REPORTS AMBER GOVERNOR LIGHT CAME ON IN FLIGHT. NO FAULT CODE WAS GENERATED INDICATING A POTENTIOMETER DEFECT HOWEVER CIRCUMSTANCES REPORTED POINTED TO…
- 8 Jan 2008
Potentiometer, failed
PILOT REPORTS AMBER GOVERNOR LIGHT CAME ON IN FLIGHT. NO FAULT CODE WAS GENERATED INDICATING A POTENTIOMETER DEFECT HOWEVER CIRCUMSTANCES REPORTED POINTED TO…
- 10 Oct 2007
Chip Detector, broken
FOLLOWING ENGINE INSTALLATION A GROUND RUN WAS ABORTED WHEN AN ENGINE CHIP LIGHT ILLUMINATED IN A DIM FLICKERING MANNER ON THE CWP. INVESTIGATION REVEALED THE…
- 26 Jul 2007
Casting, cracked
DURING ROUTINE 500 HOUR INSPECTION IT WAS DISCOVERED THAT THE CASTING AT THE AFT MOST POSITION OF THE TAILBOOM, WHICH IS THE ATTACHMENT POINT FOR THE…