N802TJ
1990 Boeing 737-4B7 standard FAA →
registration
- 1990
aircraft radio
1 past record
service difficulty reports
40 reports
- 7 May 2026
Control Module, intermittent
INTERMITTENT WARNING HORN CABIN ALTITUDE LIGHT ILLUMINATED FL 270 CAB ALTITUDE SHOWING 11000 FT. FOLLOWED QRH AND LANDED THE AIRCRAFT IN MUCU SAFELY.…
- 19 Apr 2026
Control Module, intermittent
INTERMITTENT WARNING HORN CABIN ALTITUDE LIGHT ILLUMINATED FL 270 CAB ALTITUDE SHOWING 11000 FT. FOLLOWED QRH AND LANDED THE AIRCRAFT IN MUCU SAFELY.…
- 2 Nov 2023
Battery Pack, no test
EMERGENCY LIGHT INOP OVERWING HATCH L/H AFT. REMOVE AND REPLACED BATTERY PACK AT STA. 598R, MODULE M1479. OPS CHECK GOOD IAW B737-400 AMM 33-51-51.
- 2 Nov 2023
Power Supply, no test
POWER SUPPLY AT M1479 REQUIRES REPLACEMENT. REMOVE AND REPLACED WITH SERVICEABLE POWER SUPPLY AT STA. 598R, M1479. OPS CHECK GOOD IAW B737-400 AMM 33-51-51.
- 12 Jul 2023
Battery Pack, no test
MID CABIN EMERGENCY LIGHTS ARE INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M1134 AT STA> 629 WITH SERVICEABLE UNIT AND TEST IAW B737-400 AMM…
- 2 Jul 2023
Skin, dented
DENT FUSELAGE SECTION 46 UPPER PLATING BS 993 STR 15LH
- 7 Oct 2022
Battery Pack, no test
EMERGENCY EXIT LIGHT AT L-2 DOOR INOP. REMOVED AND REPLACED M1133 BATTERY EMR ESCAPE STA 326R IAW B737-400 AMM 33-51-51. TEST GOOD.
- 7 Oct 2022
Battery Pack, no test
EMERGENCY EXIT LIGHT AT L/H OWEE INOP. REMOVED AND REPLACED M1134 EMR BATTERY PACK STA 634L IAW B737-400 AMM 33-51-51. TEST GOOD.
- 7 Oct 2022
Battery Pack, no test
EMERGENCY EXIT LIGHT AT R/H OWEE INOP. REMOVED AND REPLACED M1479 EMR LIGHT BATTERY AT STA 598R IAW B737-400 AMM 33-51-51. TEST OK.
- 7 Oct 2022
Charger, no test
FOUND EMERGENCY LIGHT BATTERY CHARGER INOP AT L/H OWEE. REMOVED AND REPLACED EMR BATTERY CHARGER M1134 STA 634L IAW B737-400 AMM 33-51-51. TEST OK.
- 15 Nov 2021
Battery Pack, discharged
EMERGENCY LIGHT AT L1 DOOR INOPERATIVE. REMOVED AND REPLACED M1133 EMERGENCY LIGHT BATTERY AT STA. 330L, IAW B737 AMM 33-51-51, OPS CHECK GOOD.
- 19 Jan 2021
Battery Pack, no test
EMERGENCY LIGHTS INOPERABLE ABOVE L2 AND AT FLOOR LEVEL AROUND R2 DOOR. REMOVED AND REPLACED AFT RT BATTERY PACK. OPERATIONS CHECK NORMAL, IAW B737-400 AMM…
- 6 Jan 2021
Battery Pack, no test
EMERGENCY LIGHT INOPERABLE ROW 9 LEFT. REMOVED AND REPLACED EMERGENCY LIGHT PACK AT STA 629L AND TEST, IAW B-737-400 AMM 33-51-51. OPERATIONS CHECK GOOD.
- 29 Oct 2020
Battery Pack, discharged
POWER SUPPLY BATTERY IN BIN 12 LT IS INOPERABLE. REMOVE AND REPLACE POWER SUPPLY BATTERY BIN 12 LT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.
- 29 Oct 2020
Battery Pack, discharged
POWER SUPPLY BATTERY IN BIN 22 LT IS INOPERABLE. REMOVE AND REPLACE POWER SUPPLY BATTERY BIN 22 LT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.
- 29 Oct 2020
Battery Pack, discharged
POWER SUPPLY BATTERY IN BIN 22 RT IS INOPERABLE. REMOVE AND REPLACE POWER SUPPLY BATTERY BIN 22 RT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.
- 29 Oct 2020
Battery Pack, discharged
POWER SUPPLY BATTERY LOCATED IN AFT GALLEY LT IS INOPERABLE. PERFORMED REMOVAL AND REPLACEMENT POWER SUPPLY BATTERY IN AFT GALLEY LT, IAW AMM 33-51-51 AND…
- 21 Sep 2019
Selector Panel, defective
NO PRESSURIZATION DURING CLIMB OUT. SUPPLEMENTAL INFORMATION, PERFORMED OPERATIONAL TEST ON PRESSURIZATION SYSTEM, TEST FAILED. REPLACED SELECTOR PANEL,…
- 20 Jul 2019
Unknown, odor
DISCREPANCY: THE CABIN AND COCKPIT EXPERIENCED A STRONG SMELL WATER HEATER LEFT AFT SIDE , OVERHEATED COFFEE POTS WERE REPORTED OVERHEATING WITH GALLEY POWER…
- 18 Jul 2019
Sense Line, loose
DISCREPANCY: FL 310 CLIMBING, CABIN BEGAN TO CLIMB UNCONTROLLABLY, RT PACK WENT TO ZERO. CORRECTIVE ACTION: PERFORMED TROUBLE SHOOTING FOUND HEAVY PENUMATIC…
- 17 Jul 2019
Shutoff Valve, malfunctioned
AT FL 310 AND CLIMBING, CABIN PRESSURE UNCONTROLABLE RT PACK 0 PSI. LOCKED OUT RT PRSOV. REMOVED AND REPLACED THE LT PRSOV.
- 22 Apr 2019
Target, out of adjust
DISCREPANCY: RT GEAR RED LIGHT ILLUMINATED WITH GEAR LEVER IN UP POSITION AFTER TAKE OFF. RECYCLED GEAR RED LIGHT ILLUMINATED AGIAN. ADJUSTED THE SENSOR…
- 17 May 2018
Power Supply, unserviceable
EMERGENCY LIGHT OUT AT STA 727D LT. REMOVED AND REPLACE POWER SUPPLY AT STA 753L REF AMM 33-51-51, OPS CHECK GOOD AT THIS TIME.
- 1 Apr 2018
Battery Pack, inoperative
RIGHT EMERGENCY HATCH EXIT SIGN LIGHT INOPERATIVE AT BS 627R. REPLACED THE BATTERY PACK.
- 1 Apr 2018
Battery Pack, discharged
LEFT FLOOR PROXIMITY FWD CENTER EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK ASSY M1479 IAW AMM 33-51-51, OPS CHECKED NORMAL.
- 24 Nov 2017
Power Supply, inoperative
SEVERAL EMERGENCY LIGHTS OUT IN CABIN. REMOVED AND REPLACED BATTERY POWER SUPPLIES AT STA 960R, S/N 37656, AND STA. 969L, S/N 15962. OPERATIONAL TEST GOOD IAW…
- 28 Aug 2017
Battery Pack, discharged
EMERGENCY LIGHTS AT ROW 5 ABC AND L1 DOOR EXTERIOR ARE INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACKS. PERFORMED OPS CHECK IAW AMM 33-51-51.
- 18 Jun 2014
Battery Pack, discharged
OVERHEAD BIN BULLNOSE EMERGENCY WHITE LIGHT OVER SEATS 7AB, 9AB & 15AB INOPERATIVE. EXTERIOR LT & RT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R BATTERY PACK…
- 29 May 2014
Battery, discharged
EMERGENCY EXIT LIGHTS AT R1 POSITION FAILED DURING SERVICE CHECK WALK AROUND. R & R BATTERY FROM THE BATTERY CHARGING PACK AT R1 POSITION IAW MM 31-51-51/201.…
- 29 May 2014
Battery, discharged
EMERGENCY LIGHT AT L1 POSITION FAILED TEST DURING SERVICE CHECK WALK AROUND. R & R BATTERY FROM THE BATTERY CHARGING PACK AT THE R1 POSITION IAW MM 31-51-52…
- 3 May 2014
Battery Pack, discharged
EMERGENCY LIGHT AT L2 POSITION INOPERATIVE. R & R BATTERY PACK PN BPS7-3 IAW AMM 33-51-51. EMERGENCY LIGHT AT R2 POSITION INOPERATIVE. R & R BATTERY PACK PN…
- 7 Mar 2014
Socket, contaminated
SEAT 6, RT OVERHEAD EMERGENCY LIGHT INOPERATIVE. CLEANED CONNECTOR OF LAMP ASSY IAW BSWPM 20-11-14 OP-CHECK OF EMERGENCY LIGHTS IAW AMM 33-51-12, NO DEFECTS…
- 7 Mar 2014
Socket, contaminated
RIGHT OVERWING EMERGENCY EXIT LIGHT LOWER FWD INOPERATIVE. CLEANED CONTACT OF LAMP ASSY IAW BSWPM 20-10-04.
- 22 Nov 2013
Feeder Cable, burned
ACFT HAD EVIDENCE OF LIGHTNING STRIKE ON RADOME AND REPLACED. ACFT RECEIVED A LIGHTNING STRIKE INSPECTION IAW AMM 05-51-27. DURING TROUBLESHOOTING NR 1 FEEDER…
- 2 Sep 2013
Battery Pack, discharged
EMERGENCY LIGHTS ON OVERHEAD BIN AT SEATS 18L, 14R, 11L, 10R 6R, INOPERATIVE. FOUND 14R BULB BURNED OUT, AND REPLACED BATTERY PACK AT BS 727 IAW AMM 33-51-51.
- 5 May 2013
Ground Wire, disconnected
EMERGENCY LIGHT AT SEAT 17A INOPERATIVE. TERMINATED GROUND WIRE SWPM 20-30-11, OPS CHECKED GOOD.
- 4 Oct 2012
Slide, no test
DURING C CHECK AN ATTEMPT TO ACCOMPLISH SWIFT AIR ROUTINE OPS CHECK OF ESCAPE SLIDE SYS, THE L2 DOOR WAS SELECTED FOR DEPLOYMENT. WITH THE SLIDE IN PLACE AND…
- 14 Aug 2012
Pin, misinstalled
DURING C-CHECK, AN ATTEMPT TO OPS CHECK L2 DOOR ESCAPE SLIDE SYS, WITH THE SLIDE PLACE AND THE GIRT BAR INSTALLED THE DOOR WAS OPENED BUT THE SLIDE FAILED TO…
- 31 Jan 2012
Frame, damaged
WHILE PERFORMING INITIAL INSPECTION REQUIREMENTS OF AD 2011-23-05 FRAME LOCATION BS 500E BETWEEN S21L AND S20L AT THE 1.04-INCH DIAMETER WIRE CABLE HOLE.…
- 9 May 2011
Coffeemaker, odor
CREW REPORTED FUMES FROM FORWARD GALLEY.