N79750
1981 Boeing 727-224 standard FAA →
aircraft radio
1 past record
earlier registrations
1 past record
- 1981
NTSB
- 7 Nov 1995
incident, Panama City PM
- 28 Dec 1983
accident, New York NY
service difficulty reports
60 reports
- 15 Jun 2004
Line, cracked
DURING FINAL APPROACH HYDRAULIC SYSTEM A QUANTITY DROPPED TO ZERO LANDED SAFELY WITHOUT INCIDENT. FOUND NR 2 ENGINE SUPPLY LINE CRACKED REPLACED SAME PER MM…
- 29 Jan 2004
Actuator, inoperative
DURING THE AFTER T/O CHECKLIST, NR 2 LEADING EDGE SLAT EXTENDED INDICATION REMAINED ON BOTH FORWARD AND AFT ANNUNCIATOR LIGHTS DUMPED FUEL AND RETURNED TO…
- 28 Jan 2004
Steering Sys, out of adjust
DISCONTINUED TAKEOFF ROLL, DUE TO LACK OF STEERING CONTROL TO THE RIGHT. RETURNED TO RAMP WITHOUT INCIDENT. ADJUSTED RUDDER PEDAL STEERING MECHANISM PER MM…
- 26 Sep 2002
Ballast, malfunctioned
DURING CLIMB, SMOKE ALARMS IN BOTH AFT LAVATORIES WENT ON, SMOKE WAS NOTICED. AFTER 20 OR 3 MINUTES IT WAS CLEAR, AFT GALLEY POWER WAS SWITCHED OFF AS…
- 23 Mar 2002
Switch, worn
ON TAXI-OUT WITH FLAPS 15 F/E AUX PANEL SHOWED NR 4 LE DEVICE NOT DOWN AND LOCKED A/C RETURNED TO GATE. REMOVED AND REPLACED NR 4 L/E DEVICE SWITCH PER MM…
- 15 Oct 2001
Hydraulic Line, leaking
FLT 523 - ARRIVING FROM SVMI, AFTER LANDING INTO MIA, HYDRAULIC SYSTEM 'A' PRESSURE AND QUANTITY INDICATION DROPPED TO 0. AIRCRAFT CONTINUED TO GATE WITHOUT…
- 20 Aug 2001
Heat Exchanger, cracked
AFTER TAKEOFF AIRCRAFT WOULD NOT PRESSURIZE. BOTH AIRCRAFT PACKS DID NOT WORK AND AFTER RESETTING BOTH PACKS TO (ON) AIRCRAFT WILL NOT PRESSURIZE. RETURNED TO…
- 11 Feb 2001
Indicator, malfunctioned
ABORTED TAKEOFF DUE TO A LOW EPR INDICATION AT REDUCED POWER ON ENGINE NR 2. INSPECTED AND CREW RAN ENGINE UP TO MAX POWER. NR 2 ENGINE OPS PROPERLY ON GROUND…
- 7 Apr 2000
Switch, out of adj
ON FAE FLIGHT NR 153, DBWI TO KIAD, DURING CLIMB AND GEAR RETRACTION, THE TAIL SKID LIGHT REMAINED ILLUMINATED. AIRCRAFT PERFORMED AN AIR RETURN TO KBWI. ON…
- 26 Feb 2000
Seal, misaligned
ON FAE FERRY FLIGHT 981 - KMIA-KFLL - DURING CLIMB, CREW HEARD LOUD NOISE FROM L1 DOOR. AIRCRAFT RETURNED TO KMIA. ON GROUND MAINTENANCE, FOUND DOOR SEAL…
- 29 Sep 1999
Pdu, binding
FLT 201 - KMIA-SDQ - DURING CLIMB AND WHILE RETRACTING FLAPS, OUTBOARD FLAPS STAYED AT 5 DEGREES. RECYCLING BY NORMAL MEANS DID NOT WORK. A/C AIR RETURNED…
- 9 Sep 1999
Megaphone, inop
INSPECTION FOUND AFT CABIN MEGAPHONE INOPERATIVE. THE MEGAPHONE WAS REPLACED.
- 16 Aug 1999
B-Nut, loose
ON FAE - FLT 945 - KMEM TO NBJ, DURING CLIMB, THROUGH FL260 NR 3 ENGINE STARTED FLUCTUATING INTERMITTENT AT FIRST THEN STEADY. AFTER LEVEL OFF AT FL290, NR 3…
- 23 Mar 1999
Floorbeam, corroded
DURING A C-CHECK, CORROSION WAS NOTED AT STA 720L, STR 27.
- 23 Mar 1999
Strap, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON STRAP IN C-1 PIT FLOOR AREA JUST FORWARD OF STA 540 THAT CROSSES FLOORBEAM.
- 23 Mar 1999
Beam, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON RT HORIZONTAL STABILIZER UPPER TRAILING EDGE BEAM.
- 23 Mar 1999
Skin, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON NR 1 NOSE FLAP OF NR 1 KREUGER FLAP AT BUSHING FLANGE ATTACH POINT.
- 23 Mar 1999
Hinge, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON R-1 DOOR'S LOWER HINGE.
- 23 Mar 1999
Channel, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON A SECTION OF HAT CHANNEL LEFT AFT LAVATORY STA 1137 - STA 1176.
- 23 Mar 1999
Stringer, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON STR 28R, STA 950F - STA 990.
- 23 Mar 1999
Seat Track, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON SEAT TRACK STA 1060 - STA 1110, LBL 45.
- 19 Sep 1998
Battery, discharged
AFT GALLEY OVERHEAD EMERGENCY LIGHT NOT WORKING. REMOVED AND REPLACED BATTERY PACK AND POWER SUPPLY.
- 11 Jun 1998
Fitting, corroded
INSPECTION FOUND LT MLG TRUNNION FITTING CORRODED. THE TRUNNION FITTING WAS REPAIRED IAW ECRA 5340-01320.
- 11 Jun 1998
Fitting, cracked
INSPECTION FOUND A 2 INCH CRACK ON L-1 DOOR UPPER HINGE FITTING. THE CRACKED AREA WAS CUT OUT, AN ANGLE REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-10-2,…
- 5 Jun 1998
Skin, delaminated
INSPECTION FOUND A 4 X 2 AREA OF RT WING TRAILING EDGE INBOARD FOREFLAP LOWER SURFACE DELAMINATED. THE FOREFLAP WAS REMOVED AND REPLACED IAW MM 27-51-12.
- 2 Jun 1998
Shear Tie, corroded
INSPECTION FOUND SHEAR TIE CORRODED AT STA 500, STRINGER 27R-28R. THE CORRODED AREA WAS CUT OUT, A NEW SHEAR TIE WAS FABRICATED AND INSTALLED IAW SRM 51-30-4,…
- 1 Jun 1998
Cowling, corroded
INSPECTION FOUND NR 2 ENGINE INLET COWLING RING CORRODED. THE CORRODED AREA WAS CUT OUT. FILLER AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 54-30-3,…
- 1 Jun 1998
Bracket, cracked
INSPECTION FOUND A 1 INCH CRACK AT LOWER INBOARD AND OUTBOARD CORNERS OF LT WING NR 1 LEADING EDGE FLAP ACTUATOR ATTACH BRACKET. THE BRACKETS WERE REMOVED AND…
- 1 Jun 1998
Bracket, cracked
INSPECTION FOUND A 1 INCH CRACK IN LT WING NR 2 LEADING EDGE FLAP ACTUATOR ATTACH BRACKET AT LOWER INBOARD CORNER INSIDE LEADING EDGE AREA. THE BRACKET WAS…
- 1 Jun 1998
Wire, broken
INSPECTION FOUND THE EMERGENCY PATH LIGHTING INOPERATIVE FROM ROW 22 AND AFT. BROKEN WIRING WAS REPAIRED AND A FUSE WAS REPLACED IAW MM 33-50-00 AND OPERATION…
- 1 Jun 1998
Skin, corroded
INSPECTION FOUND FUSELAGE SKIN CORRODED AT STA 480 TO 500, STRINGER 28R. THE CORRODED AREA WAS CUT OUT IAW SRM 53-30-3. DOUBLER AND FILLER WERE FABRICATED AND…
- 1 Jun 1998
Intercostal, corroded
INSPECTION FOUND INTERCOSTAL CORRODED IN FORWARD BAGGAGE BIN AT STA 500, RBL 9. THE INTERCOSTAL WAS REMOVED AND CORRODED STRINGER WAS CUT OUT IAW SRM 53-10-3.…
- 25 Mar 1998
Battery Pack, discharged
INSPECTION FOUND CEILING EMERGENCY EXIT LIGHT BETWEEN R-2 DOOR AND L-2 DOOR INOPERATIVE. THE BATTERY PACK WAS REMOVED AND REPLACED.
- 22 Jan 1998
Structure, damaged
THE AIRCRAFT SUSTAINED GROUND DAMAGE TO THE FUSELAGE SKIN, STRINGER, AND FRAMES AT STA 440-480, STRINGERS 14-19L. THE FUSELAGE SKIN AND STRINGER WERE REPAIRED…
- 29 Oct 1997
Power Supply, inoperative
INSPECTION FOUND RIGHT AFT CARGO DOOR EMERGENCY EXIT LIGHT INOPERATIVE. THE BATTERY POWER SUPPLY WAS REMOVED AND REPLACED.
- 10 Oct 1997
Fuse, blown
EMERGENCY TRACK LIGHTS INOP ROW 10 FORWARD. REMOVED AND REPLACED FUSES.
- 19 Mar 1997
Stringer, deformed
INSPECTION FOUND SKIN BULGED IN STRINGER 2-3L AREA AT STA 420 WITH STRINGER DEFORMED. A STRINGER REPAIR WAS INSTALLED IAW SRM 53-10-3.
- 19 Mar 1997
Support, corroded
INSPECTION FOUND INBOARD END OF FLOOR SUPPORT CORRODED AT STA 342, RBL 17. THE SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-2.
- 19 Mar 1997
Support, broken
INSPECTION FOUND FLOOR SUPPORT BROKEN AT STA 758, BL 0. THE SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-10-1.
- 19 Mar 1997
Circumferential, cracked
INSPECTION FOUND A 1 INCH CRACK IN CIRCUMFERENTIAL AT STA 804, STRINGER 14L. THE CRACK WAS STOP DRILLED. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM…
- 19 Mar 1997
Circumferential, cracked
INSPECTION FOUND A 1 INCH CRACK IN CIRCUMFERENTIAL AT STA 930, STRINGER 14R. THE CRACKED AREA WAS REMOVED AND REPAIR PARTS WERE INSTALLED IAW EC 5310-01397,…
- 19 Mar 1997
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 344, LBL 10 AND RBL 10. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED. A NEW SECTION WAS FABRICATED AND INSTALLED…
- 19 Mar 1997
Stiffener, cracked
INSPECTION FOUND A .75 INCH CRACK IN STIFFENER AT BS 348, STRINGER 10R. THE STIFFENER WAS REPAIRED IAW SRM 51-30-2.
- 19 Mar 1997
Support, corroded
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 1067, RBL 26. A NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-10-1.
- 19 Mar 1997
Support, corroded
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 1033, RBL 26. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-1.
- 17 Mar 1997
Floor Pan, corroded
INSPECTION FOUND LEFT AFT LAV FLOOR PAN CORRODED. A FILLER AND DOUBLER REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-10-6.
- 17 Mar 1997
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT BS 1050, RBL 26 TO 66. THE CORRODED AREA WAS REMOVED AND A NEW SECTION WAS FABRICATED AND INSTALLED IAW SRM 53-10-8,…
- 17 Mar 1997
Support, corroded
INSPECTION FOUND FLOOR SUPPORT CORRODED FROM STA 1070 TO 1140, RBL 66. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-1 AND 51-10-6.
- 10 Mar 1997
Floor Panel, corroded
INSPECTION FOUND CABIN FLOOR PANEL CORRODED AT B.S. 1144, RBL 40. A REPAIR WAS PERFORMED IAW SRM 51-40-2 AND 51-10-2.
- 10 Mar 1997
Bulkhead, corroded
INSPECTION FOUND BULKHEAD AND SKIN CORRODED IN FORWARD CARGO BILGE AREA AT STA 560, STRINGER 28R. THE CORROSION WAS REMOVED IAW SRM 51-10-6. A SKIN REPAIR WAS…
- 10 Mar 1997
Floor Support, corroded
INSPECTION FOUND INBOARD END OF CABIN FLOOR SUPPORT CORRODED AT STA 342. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-1, 51-10-2, AND 51-40-4.
- 10 Mar 1997
Floor Support, broken
INSPECTION FOUND FLOOR SUPPORT BROKEN AT STA 758, BL ZERO. THE FLOOR SUPPORT WAS REMOVED. A NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-10-1.
- 10 Mar 1997
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 300, RBL 12 TO RBL 40. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED, A NEW SECTION WAS FABRICATED AND INSTALLED…
- 7 Mar 1997
Stringer, corroded
INSPECTION FOUND STRINGER 27L IN FORWARD BILGE AREA CORRODED AT STA 560. THE STRINGER WAS REMOVED AND A NEW ONE WAS FABRICATED AND INSTALLED IAW SRM 51-30-2…
- 7 Mar 1997
Splice, corroded
INSPECTION FOUND STRINGER 27 SPLICE CORRODED AT STA 660 IN FORWARD CARGO BILGE AREA. THE SPLICE WAS REMOVED AND THE CORROSION ON SKIN WAS REMOVED. A NEW…
- 7 Mar 1997
Skin, corroded
INSPECTION FOUND LOWER FUSELAGE SKIN CORRODED AT STA 580. THE CORRODED SECTION OF SKIN WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 53-30-3.
- 7 Mar 1997
Rib, cracked
INSPECTION FOUND A 1 INCH CRACK IN UPPER RIB CAP OF RT WING LEADING EDGE FS 340. THE ANGLE WAS REMOVED, A NEW ANGLE WAS FABRICATED AND INSTALLED IAW SRM…
- 27 Feb 1997
Floor Support, corroded
INSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 344, RBL 15. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-30-2.
- 27 Feb 1997
Angle, cracked
INSPECTION FOUND A 2 INCH CRACK IN LT WING ANGLE AT OUTBOARD SIDE OF LEADING EDGE NOSE RIB, SLAT STA 0. A REPAIR ANGLE WAS INSTALLED IAW SRM 51-40-3.
- 29 Jan 1996
Light, inoperative
STATION 31J - INSPECTION FOUND THE AFT GALLEY SERVICE DOOR AND FORWARD LIFE RAFT BIN EMERGENCY LIGHTS INOPERATIVE. THE EMERGENCY LIGHTS AT LIFE RAFT BIN WERE…