N78KN
2021 Gulfstream Aerospace Corp GVII-G500 standard FAA →
registration
- 2021
aircraft radio
2 past records
service difficulty reports
15 reports
- 11 Jan 2012
Actuator, leaking
RT ENGINE, INBD THRUST REVERSER ACTUATOR LEAKING. MM SPECIFICALLY STATES THERE ARE NO ALLOWABLE LEAKAGE FOR COMPONENTS, FILTERS, PRESSURE SWITCHES,…
- 11 Jan 2012
Actuator, leaking
LT ENGINE, INBD THRUST REVERSER ACTUATOR LEAKING. MM SPECIFICALLY STATES THERE ARE NO ALLOWABLE LEAKAGE FOR COMPONENTS, FILTERS, PRESSURE SWITCHES,…
- 22 Dec 2011
Check Valve, faulty
POTABLE WATER IN LAV HAS LOW PRESSURE AND PUMP CONTINUOUSLY CYCLES. R & R DRAIN CHECK VALVE. OPS CHECKED GOOD. INSPECTED CHECK VALVE ON BENCH AND FOUND VALVE…
- 22 Dec 2011
Wire, broken
AFT BAY MX LIGHT WILL NOT STAY ON. FOUND MULTIPLE BROKEN WIRES AT AFT STEP FAIRING, SWITCH TO SPLICE, ON LT AND RT SIDE OF ACCESS DOOR. REPAIRED AFFECTED…
- 22 Dec 2011
Processor, faulted
WITH ONLY APU RUNNING, MAU 2B FAULTED RESULTING IN THE APU SHUTING DOWN. PILOT RESTARTED APU AND FAULT DID NOT RETURN. MX COULD NOT DUPLICATE PROBLEM. FAULT…
- 15 Nov 2011
Fan, inoperative
DURING POSTFLIGHT, FOUND BOTH AFT BAY HEAT EXCHANGER FANS INOP. R & R BOTH HEAT EXCHANGERS FANS. OPS CHECKS GOOD. MX RECOMMENDS OTHER OPERATORS CHECK FOR OPS…
- 15 Nov 2011
Connector, disconnected
WHILE CHANGING LT AFT BAY HEAT EXCHANGER FOUND CB PANEL 3, PLUG P1634D, PIN: M FOR WIRE A201-W01-16 CAPPED AND TIED BACK CAUSING LT AFT BAY BLOWER TO BE…
- 15 Nov 2011
Fan, inoperative
DURING POSTFLIGHT FOUND BOTH AFT BAY HEAT EXCHANGER FANS INOPERATIVE. R & R BOTH HEAT EXCHANGERS FANS. OPS CHECKED GOOD.
- 15 Nov 2011
Shutoff Valve, failed
LT PACK FAILED IN FLIGHT WHEN THROTTLES PULLED TO IDLE. R & R LT PACK PRESSURE RELIEF SHUTOFF VALVE (PRSOV). SYS OPS CHECKS GOOD.
- 16 Oct 2011
Heater, inoperative
GALLEY DRAIN INOPERATIVE AT SINK AND COFFEE MAKER. FOUND HEATED DRAIN LINE IS NOT HEATING UP.
- 16 Oct 2011
Display, inoperative
DURING POST FLIGHT, FOUND CMC INOPERATIVE ON CO-PILOTS MFDU. FOUND FILE SERVER 2 AFSEM 2 FAULTED. PERFORMED TARGET LOAD OF SOFTWARE LOAD 20 AND SYS CHECKED…
- 28 Sep 2011
Circuit Card, failed
FOUND CMC CARD TO BE FAILED. R & R CMC MODULE ASSY (CARD). OPS CHECKS GOOD.
- 23 Sep 2011
Pump, leaking
ERS PUMP LEAKING. FOUND LEAKING FROM OVERBOARD DRAIN LINE. R & R ERS PUMP ASSY.
- 23 Apr 2010
Pump, making metal
DPI FOUND EXTENDED DURING PF INSPECTION. REMOVED FILTER AND FOUND MINOR METAL IN FILTER AND FILTER HOUSING. REPLACE RT HYDRAULIC ENGINE DRIVEN PUMP.
- 19 Nov 2009
Pump, making metal
DPI FOUND EXTENDED DURING INITIAL 100 HOUR INSPECTION. REMOVED FILTER AND FOUND METAL IN FILTER AND FILTER HOUSING. REPLACE RT HYDRAULIC ENGINE DRIVEN PUMP.