N781EJ
2006 Embraer ERJ 170-100SU standard FAA →
registration
- 2006
service difficulty reports
17 reports
- 15 Oct 2026
Battery, inoperative
FOUND R2 EMERGENCY LIGHT INOP DURING PS-2 CHK. RAR EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01. NO FURTHER DEFECTS NOTED. OPS CHK GOOD
- 10 Sep 2026
Yoke, loose
YOKE LOSE AFTER TAKEOFF AS SOON AS ACFT ROTATED CA YOKE JERKED TO THE RT. CONTINUED FLYING, YOKE WAS ABNORMALLY LOOSE & MORE PRONOUNCED WITH RT INPUT AND FO…
- 30 Jul 2026
Door, no discrepancy
GATE AGENT SAID L1 DOOR WAS HARD TO OPEN L1 DOOR OPC OK IAW AMM 52-11-00
- 6 Jul 2026
Door, no discrepancy
GATE AGENT REPORTS L1 DOOR DIFFICULT TO OPEN FROM OUTSIDE. MAIN HANDLE REQUIRED EXCESSIVE FORCE TO OPERATE. PERFORRMED OPC OF FWD PASSENGER DOOR IAW EMB 170…
- 11 May 2026
Door, no discrepancy
UPON ARRIVAL TO GATE THE GATE AGENTS WE'RE UNABLE TO OPEN 1L DOOR. OPENED L1 DOOR PER AMM SDS 52-11-00. OPS CHECKED DOOR 3 TIMES. OPS CHECK GOOD. NO DEFECTS…
- 8 May 2026
Sign, inoperative
FOUND AFT R2 EMERGNCY EXIT MARKING INOP REMOVED AND REPLACED AFT R2 EMERGENCY EXIT MARKING IAW AMM 33-50-17. OPC GOOD.
- 3 Dec 2025
Floorbeam, corroded
SSI 53-23-005 RIGHT FLOOR CROSSBEAM BETWEEN WALL AND CENTER SEAT TRACK BEAM AT FRAME 84 IS CORRODED. (MAJOR REPAIR) (LEVEL 2 CORROSION) REPAIRED CROSSBEAM IAW…
- 18 Oct 2025
Floorbeam, corroded
RIGHT FLOORBEAM BETWEEN WALL AND CENTER SEAT TRACK BEAM AT FR84 CORRODED (MAJOR REPAIR). REPAIREDTHE FLOORBEAM IAW ERS-EJ-53MR- 5301.
- 18 Oct 2025
Light, damaged
RH EMERGENCY PHOTOLUMINESCENT LIGHT STRIPS DAMAGED COMPLETE: INSTALLED SERVICEABLE RH EMERGENCY PHOTOLUMINESCENT LIGHT STRIPS IAW AMM 33-50-21
- 24 Aug 2025
Rod, faulted
FA 1 REPORTS L1 IS DIFFICULT TO CLOSE AND REPORTS THAT THE GATE AGENTS ARE HAVING DIFFICULTY OPENING IT. R & R L1 DOOR AFT COUNTERBALANCE ROD AS PER AMM…
- 12 Aug 2025
Door, no discrepancy
L1 DOOR DIFFICULTY OPENING WHEN OPENED FROM THE OUTSIDE. CYCLED L1 DOOR MULTIPLE TIMES PER GHC. NO DEFECTS WHERE NOTED AT THIS TIME
- 4 Aug 2025
Door, no discrepancy
L1 DOOR NOT OPENING SMOOTHLY. HAVE TO PUSH FROM INSIDE TO GET IT OPEN. OPERATED L1 DOOR IAW GHC, FOUND DOOR TO OPERATE AS INTENDED.
- 9 May 2025
Flashlight, inoperative
AFT GALLEY EMERGENCY FLASHLIGHT INOP. RELAMPED EMERGENCY FLASHLIGHT IAW AMM 33-51-01, OPS CHECK GOOD.
- 19 Apr 2025
Door, unknown
FA COMPLAINED THAT L1 DOOR WAS REALLY DIFFICULT TO OPEN. CYCLED DOOR MULTIPLE TIMES, NO DEFECTS NOTED
- 9 Apr 2025
Liner, out of position
1L DOOR HARD TO OPEN FROM OUTSIDE "TRANSFERRED TO NRWC 781-DFW-01816 ITEM-1" REF NRWC # 781-DFW-01815, 781-DFW-01816, AND 781-DFW-01817. FOUND INTERFERENCE…
- 6 Apr 2025
Door, lack of lube
L1 DOOR VERY HARD TO OPEN OR CLOSE. CLEANED AND LUBRICATED L1 DOOR MECHANISMS IAW:AMM 52-11-00 OPC GOOD
- 18 Oct 2024
A/C Pack, odor
ELECTRICAL BURNING SMELL FOR 10-15 MINUTES BEFORE AND AFTER PACK 1 FAILED 2X DURING DESCENT. EVENTUALLY WENT AWAY. NO ALERTS/ MESSAGES. REF AML 110400019/1…