- 1979
NTSB
- 12 Sep 2003
accident, Norfolk VA
service difficulty reports
94 reports
- 9 Apr 2011
Light, inoperative
DURING LINE CHECK, MX FOUND THAT THE LT EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHT RETURNED TO AN OPERATIONAL…
- 7 Oct 2010
Skin, dented
DURING LINE CHECK FOUND DENT IN SKIN AFT OF CARGO DOOR AT BS 1108 & BS 1121 L22R TO L26R. REPAIRED IAW ERA 486265-14.
- 4 Oct 2010
Battery Pack, inoperative
DURING LINE CHECK, MX FOUND THAT THE EMERGENCY EXIT SIGN AT THE MAIN CABIN DOOR, ALSO THE G2 GALLEY AND COAT CLOSEST EMERGENCY LIGHTS WERE ALL INOPERATIVE. MX…
- 10 Jul 2010
Rod, stuck
RETURNED TO ATL DUE TO LANDING GEAR WOULD NOT RAISE WITHOUT USE OF LANDING GEAR OVERRIDE, AUTO SPOILER LIGHT ON, AND STALL INDICATION FAILURE. MAINTENANCE…
- 23 Apr 2010
Shear Tie, worn
DURING H-CHECK FOUND WEAR ON SHEAR TIE BOLT HOLE AT BS 1247 L13R. REPAIRED IAW SRM 53-03-03, 51-30-05.
- 21 Apr 2010
Frame, cracked
DURING H-CHECK FOUND FRAME CRACKED AT BS 734 RT SIDE. REPAIRED PER SRM 51-30-4, 51-30-5, 51-10-4, 51-10-3.
- 20 Apr 2010
Skin, misrepaired
DURING H-CHECK FOUND SKIN REPAIR BS290-BS358 BETWEEN L18R-L19R DOES NOT MEET SRM REQUIREMENTS. REPAIRED IAW SRM 53-04-12C.
- 20 Apr 2010
Angle, cracked
DURING H-CHECK FOUND ANGLE CRACKED AT TOP OF CTR FUEL TANK BS 750 RBL 44. REPAIRED IAW SRM 06-10-01, 51-70-05 FIGURE 2.
- 17 Apr 2010
Frame, chafed
DURING H-CHECK FOUND FRAME CHAFED AT BS 1247 L13R. REPAIRED IAW SRM 51-72-01.
- 17 Apr 2010
Floor Panel, cracked
DURING H-CHECK FOUND FLOOR PANEL NR60B CRACKED AT FWD AND AFT END. REPAIRED IAW SRM 51-10-2, 51-30-2.
- 16 Apr 2010
Door Frame, cracked
DURING H-CHECK FOUND CRACK IN DOOR JAMB WEB AT BS 1112 L26R. REPAIRED IAW SRM 53-13-3, 53-30-2, 51-30-05.
- 16 Apr 2010
Floor Panel, corroded
DURING H-CHECK FOUND CORROSION ON FLOOR PANEL NR 15. REPAIRED IAW DWG 9357825 AND SRM 51-10-04.
- 16 Apr 2010
Door Frame, corroded
DURING H-CHECK FOUND CORROSION ON UPPER DOOR JAMB WEB AT BS1060-BS1067 L24R-L26R. REPAIRED IAW SRM 51-70-04 FIGURE 2.
- 16 Apr 2010
Cargo Track, corroded
DURING H-CHECK FOUND CARGO TIE DOWN TRACK CORRODED IN FWD CARGO COMPARTMENT AT BS218-BS598 L26L TO L27L. REPAIRED IAW DWG S2922357 AND SRM 53-21-0, 51-30-01,…
- 16 Apr 2010
Support Fitting, corroded
DURING H-CHECK FOUND CTR FUEL TANK SUPPORT FITTING CORRODED AT BS693-BS712. REPAIRED IAW SRM 51-10-4, 51-30-01, 51-30-05 PAGE 205.
- 15 Apr 2010
Door Frame, corroded
DURING "H" CHECK FOUND LOWER DOOR JAMB PAN CORRODED IN AFT CARGO COMPARTMENT. BS1060-BS116 L29R TO L26R. REPAIRED IAW SRM 53-13-3, 53-05-44.
- 15 Apr 2010
Longeron, cracked
DURING "H" CHECK FOUND CRACK IN L28R IN E&E COMPARTMENT. REPAIRED IAW SRM 53-02-18, 51-30-2, 51-30-5, 51-10-3.
- 15 Apr 2010
Longeron, cracked
DURING "H" CHECK FOUND CRACK IN L28L IN E&E COMPARTMENT. REPAIRED IAW SRM 53-02-18, 51-30-2, 51-30-5, 51-10-3.
- 15 Apr 2010
Cargo Track, corroded
DURING "H" CHECK FOUND CORROSION ON RT CARGO TIE DOWN TRACK AT BS851 TO BS1060. REPAIRED IAW SRM 51-10-4, 53-23-0, 51-30-5.
- 15 Apr 2010
Cargo Track, corroded
DURING "H" CHECK FOUND CORROSION ON LT CARGO TIE DOWN TRACK AT BS1032 TO BS1167. REPAIRED IAW SRM 51-10-4, 53-23-0, 51-30-5.
- 14 Apr 2010
Frame, chafed
DURING H-CHECK FOUND AFT ACCESSORY COMPARTMENT CANTED FRAME AT BS 1339 CHAFED ON RT SIDE. REPAIRED PER SRM 51-30-1, 51-30-2, 51-30-5, 51-10-4.
- 13 Apr 2010
Doubler, chafed
DURING H-CHECK, FOUND CHAFED DOUBLER ON AFT ACCESSORY COMPARTMENT RT TOP CORNER CUT OUT. REPAIRED IAW SRM 51-30-05, 51-30-01.
- 13 Apr 2010
Shear Tie, cracked
DURING H-CHECK FOUND SHEAR CLIP CRACKED AT BS 1151 BELOW STRINGER 14L. REPAIRED IAW SRM 51-30-02, 51-30-05.
- 7 Apr 2010
Frame, cracked
DURING H-CHECK FOUND CRACK IN FORMER AT BS 1167 AT L18. REPAIRED IAW SRM 51-10-4, 51-30-02, 51-30-05.
- 7 Apr 2010
Shear Tie, cracked
DURING H-CHECK FOUND CRACK IN SHEAR TIE CLIP LT OTBD END AT BS 734. REPAIRED IAW SRM 53-03-12, 51-10-4, 51-30-5.
- 7 Apr 2010
Membrane, damaged
DURING H-CHECK FOUND MEMBRANE UNDER FLOOR PANEL NR 13 BS 153 HAS HOLE IN IT. REPAIRED IAW SRM 53-01-4, 51-10-2, 51-10-4, 53-20-03-801.
- 7 Apr 2010
Floor Panel, damaged
DURING H-CHECK FOUND FLOOR PANEL NR 59 FWD END HAS ELONGATED FASTENER HOLE. REPAIRED IAW SRM 51-10-3, 51-70-4, 51-30-2.
- 7 Apr 2010
Skin, dented
DURING H-CHECK FOUND SKIN DENT AT BS 217 BETWEEN L17R AND L18R. REPAIRED IAW DWG SG09530001.
- 6 Apr 2010
Membrane, damaged
DURING H-CHECK FOUND MEMBRANE DAMAGED AT BS 209 RBL10. REPAIRED IAW SRM 53-01 AND SRM 53-20-03-801.
- 5 Apr 2010
Floor Panel, cracked
DURING H-CHECK FOUND FLOOR PANEL NR 20 IS CRACKED IN 3 PLACES AND HAS CORROSION ON TOP AND BOTTOM OF PANEL. REPAIRED IAW SRM 51-10-4.
- 3 Apr 2010
Floor Panel, corroded
DURING H-CHECK FOUND FLOOR PANEL NR 78 BOTTOM EDGE CORRODED. REPAIRED IAW SRM 51-30-2, 51-10-4, 51-30-2.
- 3 Apr 2010
Floor Panel, corroded
DURING H-CHECK FOUND CORROSION ON CABIN FLOOR PANEL NR 23. REPAIRED IAW SRM 53-23-0, 51-30-2, 51-30-8.
- 3 Apr 2010
Floor Panel, damaged
DURING H-CHECK FOUND FLOOR PANEL NR 72 SEVERAL FASTENER HOLES ELONGATED AND TORN OUT ON FWD AND AFT END OF PANEL. REPAIRED IAW SRM 51-70-04, 51-10-03,…
- 3 Apr 2010
Floor Panel, damaged
DURING H-CHECK FOUND FLOOR PANEL NR 55 HAS HOLE ON INBD SIDE. REPAIRED IAW SRM 51-10-2, 51-10-4, 51-10-3, 51-30-2, 51-30-1.
- 3 Apr 2010
Floorbeam, corroded
DURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS180 RBL 22-44. REPAIRED IAW SRM 51-10-4, 51-30-5, 51-20-0.
- 3 Apr 2010
Skin, dented
DURING H-CHECK FOUND DENT IN SKIN AT BS 218 BETWEEN L17R AND L16R. REPAIRED IAW SRM 51-30-1, DWG SG09530001.
- 2 Apr 2010
Floorbeam, corroded
DURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 200 BETWEEN LBL 22-44. REPAIRED IAW 53-01-1, 51-10-4, 51-30-5.
- 2 Apr 2010
Floor Panel, corroded
DURING H-CHECK FOUND FLOOR PANEL NR 61 TOP AND BOTTOM CORRODED. REPAIRED IAW SRM 53-23-0, 51-10-2, 51-10-4, 51-30-2.
- 2 Apr 2010
Seat Track, corroded
DURING H-CHECK FOUND CORROSION ON SEAT TRACK AT BS 200-275 LBL44. REPAIRED IAW SRM 53-05-4.
- 2 Apr 2010
Floor Panel, gouged
DURING H-CHECK FOUND FLOOR PANEL NR 73 TOP SKIN HAS HOLE GOUGED IN SURFACE. REPAIRED IAW SRM 53-01-4.
- 2 Apr 2010
Floor Support, corroded
DURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 160-200 BETWEEN LBL44. REPAIRED IAW 51-10-3, 53-13-1, 51-10-1, 53-01-1, 51-10-4, 51-30-5.
- 2 Apr 2010
Floor Support, corroded
DURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 218-275 BETWEEN BL 0. REPAIRED IAW 51-10-4.
- 2 Apr 2010
Floor Support, corroded
DURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 160-200 BETWEEN RBL 44. REPAIRED IAW 51-10-1, 53-01, 53-30-02, 51-30-5, 51-10-4, 51-10-03.
- 2 Apr 2010
Web, cracked
DURING H-CHECK FOUND CRACK ON FLOOR WEB UNDER FLOOR PANEL NR 98. REPAIRED IAW SRM 53-10-16, 51-10-3, 51-30-2.
- 2 Apr 2010
Floorbeam, corroded
DURING H-CHECK, FOUND CORROSION ON FLOOR SUPPORT AT BS200 BETWEEN RBL 22-44. REPAIRED IAW SRM 53-13-1, 51-30-2.
- 29 Mar 2010
Door Frame, cracked
DURING H-CHECK FOUND L1 DOOR JAMB WEB CRACKED AT ATTACH POINT TO INTERCOSTAL AT L12L. REPAIRED IAW SRM 53-01-4, 51-10-3, 51-30-2 AND 51-30-5.
- 8 Mar 2010
Battery Pack, inoperative
DURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 23-26 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE ASSOCIATED FUSE…
- 15 Feb 2010
Fuse, failed
DURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 23-26 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE FUSES IN THE POWER…
- 5 Feb 2010
Battery Pack, inoperative
DURING OVERNIGHT CHECK FOUND EMERGENCY LIGHTS AT ROW 22 TO 26 INOP. MX R & R BATTERY AND POWER SUPPLY. OPS CHECKED GOOD AND ACFT WAS RETURNED TO SERVICE.
- 5 Feb 2010
Battery Pack, discharged
DURING OVERNIGHT CHECK FOUND EMERGENCY LIGHTS AT ROWS 5, 7, AND 9 WERE INOP. MX CHARGED BATTERY PACKS. OPS CHECKED GOOD, AND ACFT WAS RETURNED TO SERVICE.
- 21 Jan 2010
Battery Pack, inoperative
DURING LINE CHECK, MX FOUND THAT THE RT SIDE EXTERIOR EMERGENCY LIGHT WAS INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHT RETURNED TO AN OPERATIONAL…
- 21 Jan 2010
Battery Pack, inoperative
DURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 23-26 OF THE CABIN WERE INOPERATIVE. MX REPLACED THE BATTERY PACK AND THE LIGHTS…
- 3 Jan 2010
Power Supply, inoperative
DURING LINE CHECK, MX FOUND THAT THE EMERGENCY EXIT SIGN AT THE MAIN CABIN DOOR WAS INOPERATIVE. MX REPLACED THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN…
- 3 Jan 2010
Battery Pack, inoperative
DURING LINE CHECK, MX FOUND INOPERATIVE EMERGENCY PATHWAY LIGHTING IN ROWS 22 AND AFT IN THE CABIN. MX REPLACED THE BATTERIES IN THE POWER SUPPLY AND THE…
- 3 Sep 2009
Battery, discharged
DURING LINK CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 13-17 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES.…
- 25 Jun 2009
Battery Pack, inoperative
DURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 22-26 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK…
- 6 Nov 2008
Connector, loose
DURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING FROM ROWS 22 AND AFT WERE INOPERATIVE. MX FOUND AND CORRECTED A LOOSE CONNECTION AND THEN OPS…
- 8 Jun 2008
Battery Pack, inoperative
DURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE TAIL COMPARTMENT HAD INOPERATIVE LIGHTS FOR THE CATWALK. MAINTENANCE REPLACED…
- 8 Jun 2008
Battery Pack, inoperative
DURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHTS FOR THE FWD OVERWING HATCHES WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK…
- 11 Sep 2007
Battery Pack, inoperative
TAIL COMPARTMENT CATWALK EMERGENCY LIGHT INOP. REPLACED BATTERY PACK. OPERATION CHECKS GOOD.
- 9 Feb 2007
Skin, cracked
DURING "H" CHECK FOUND 1/4" CRACK IN FUSELAGE SKIN AT BS 370 FORWARD CARGO DOOR CUTOUT. REPAIRED PER EA 98-208811.
- 12 Jan 2004
Duct, loose
AT REACHING FL330, THE CABIN CONTINUED TO CLIMB. CREW WAS NOT ABLE TO CONTROL CABIN CLIMB SO AN EMERGENCY DESCENT WAS PERFORMED. ACCOMPLISHED COM PROCEDURES.…
- 28 Oct 2002
Duct, separated
AIRCRAFT LOST AUTO PRESSURIZATION AT FL240 AND CRUISE POWER. CREW ATTEMPTED MANUAL CONTROL BUT WAS UNABLE TO KEEP THE CABIN FROM CLIMBING. COMPLIED WITH COM…
- 12 Aug 2002
Intercostal, cracked
During Mck in ATL, the inbrd edge of the floor support intercostal at station 180 was found with two cracks between x=20 and x=30.
- 2 Aug 2002
Angle, corroded
During Mck in ATL, corrosion was found in the left upper cusp angle at station 200. Repaired per EA 98-190596.
- 24 Jul 2002
Rib, cracked
During Mck in ATL, a crack was found in the left wing leading edge rib at station x 134.921. The crack emanates from the fastener hole and extends inbrd to…
- 19 Jul 2002
Bracket, cracked
During Mck in ATL, 2 cracks were found on the left and right station 69 brackets X=+- 10". Repaired per EA 98-190582.
- 30 May 2002
Transmitter, faulty
FLAPS SET TO 15 DEGREES FOR TAKEOFF, THE RIGHT FLAP INDICATOR SHOWED 15 DEGREES BUT THE LEFT INDICATOR SHOWED 18 DEGREES. CREW EXPERIENCED A TENDENCY TO ROLL…
- 24 Jan 2001
Wheel, cracked
DURING PUSHBACK FROM THE GATE AREA AT YUL, THE PUSHBACK CREW REPORTED THAT THE RIGHT INNER WHEEL WAS CRACKED. THE AIRCRAFT WAS RETURNED TO THE GATE WITHOUT…
- 8 Feb 2000
Unknown, odor
TAKEOFF FUMES/SMELL WERE REPORTED BY THE FLIGHT ATTENDANT. AIRCRAFT RETURNED TO DEPARTURE AIRPORT. MAINTENANCE REPLACED THE APU AND LEFT ACM. THE 8TH AND 13TH…
- 14 Nov 1999
Apu, leaking
AFTER TAKEOFF AFT LEFT LAV SMOKE DETECTOR SOUNDED AND SMOKE APPARENT IN LAV. MAINTENANCE FOUND OIL LEAK FROM THE APU WAS BEING INGESTED INTO THE AC PNEUMATIC…
- 14 Nov 1999
Acm, contaminated
AFTER TAKEOFF SMOKE ALARMS IN 3 LAVS SOUNDED AND FUMES WERE PRESENT IN THE CABIN. AIRCRAFT RETURNED TO DEPARTURE AIRPORT. MAINTENANCE RAN ENGINES AT TAKEOFF…
- 23 May 1999
Hinge, broken
AFTER CONFIGURING FOR LANDING, A THUMP WAS FELT/HEARD AND A SPLIT FLAP INDICATION WAS NOTICED BY FLIGHT CREW AT APPROXIMATELY 8 DEGREES RIGHT FLAP AND 40…
- 2 Feb 1998
Battery Pack, discharged
DURING INSPECTION, THE AFT CABIN FLOOR PROXIMITY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHTS BATTERY PACK, OPERATIONAL…
- 19 Jan 1998
Pressure Web, cracked
DURING L CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL AT THE RIGHT OUTBOARD VERTICAL ATTACH ANGLE FS 110. REPAIRED PER…
- 19 Jan 1998
Pressure Web, cracked
DURING L CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL AT THE LEFT OUTBOARD VERTICAL ATTACH ANGLE FS 110. REPAIRED PER EA…
- 3 Jan 1998
Wire, burned
FLIGHT CREW MEMEBER DISCOVERED A SMALL FLAME IN THE LEFT WHEEL WELL AT THE LOCATION OF THE ELECTRIC HYDRAULIC PUMP CANNON PLUG. GROUND PERSONNEL EXTINGUISHED…
- 1 Jun 1997
Power Pack, inoperative
DURING LINE CHECK, FOUND RIGHT EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED BULB AND POWER PACK FOR RIGHT OVERWING LIGHT, OPERATIONAL CHECK OK.
- 10 Apr 1997
Switch, failed
DURING TAKEOFF ROLL AT APPROXIMATELY 80 KNOTS, RECEIVED TAKEOFF WARNING HORN. TRIM, SPOILERS, FLAPS, SLATS, AND BRAKES ALL IN PROPER POSITION SO TAKEOFF WAS…
- 27 Mar 1997
Air Cycle Mach, failed
RIGHT AIR CONDITIONING PACK FAILED DURING CLIMB CAUSING LOSS OF PRESSURIZATION. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED LEFT…
- 18 Mar 1997
Warning Sensor, dirty
DURING TAKEOFF ROLL, TAKEOFF WARNING HORN SOUNDED AT APPROXIMATELY 85 KNOTS. ABORTED TAKEOFF. RECHECKED TAKEOFF CONFIGURATION, ALL SYSTEM CORRECT. RETURNED TO…
- 29 Dec 1996
Csd, leaking
AFTER TAKEOFF, LEFT CSD OIL PRESSURE LOW LIGHT ILLUMINATED. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. FOUND CSD OIL COOLER LEAKING. REPLACED LEFT…
- 19 Oct 1996
Power Supply, inoperative
DURING LINE MAINTENANCE INSPECTION, FOUND FLOOR PROXIMITY EMERGENCY LIGHTS BETWEEN ROWS 9 THROUGH 15 VERY DIM. REPLACED POWER SUPPLY AND BATTERY, OPERATIONAL…
- 17 Oct 1996
Batteries, discharged
DURING LINE CHECK, FOUND EMERGENCY EXIT LIGHTS IN VENTRAL STAIR INOPERATIVE. REPLACED BATTERIES IN B5-28, OPERAITONAL CHECK OK.
- 23 Aug 1996
Power Supply, inoperative
DURING LINE CHECK, FOUND RIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY, OPERATIONAL CHECK OK.
- 20 Jun 1996
Floor Beam, corroded
DURING H-CHECK, FOUND CORROSION ON THE FS 1108 FLOOR BEAM AT RBL 14. REPAIRED BEAM (P/N 9958186-1) PER EA 98-110807.
- 20 Jun 1996
Floor Beam, corroded
DURING H-CHECK, FOUND CORROSION ON THE FS 1136 FLOOR BEAM RIGHT SIDE. REPAIRED BEAM (P/N 9912243-59) PER EA 98-110806.
- 20 Jun 1996
Cusp, corroded
DURING H-CHECK, FOUND CORROSION ON THE RIGHT CUSP FROM FS 1136 TO 1167. REPAIRED CUSP (P/N 2777976) PER EA 98-110533.
- 17 Jun 1996
Fitting, cracked
DURING H-CHECK, FOUND CRACKS IN THE AFT CARGO DOOR END FITTINGS, NR 1 AFT, NR 2 AFT AND NR 5 FORWARD. REPLACED ALL THREE END FITTINGS.
- 20 May 1996
Controller, malfunctioned
DURING DESCENT, CABIN BEGAN TO CLIMB AT 1,500 FPM. BEGAN A RAPID DESCENT TO 10M AND WORKED CONTROLLER MANUALLY. CABIN PRESSURE LIGHT CAME ON AND CABIN GOT TO…
- 29 Feb 1996
Gearbox, damaged
CLIMBING THROUGH FL190, NR 2 ENGINE OIL PRESSURE AND QUANTITY DROPPED TO ZERO. THE ENGINE WAS SHUTDOWN AND THE FLIGHT RETURNED TO DTW WITHOUT FURTHER…
- 7 Feb 1996
Release Mech, malfunctioned
DURING LINE CHECK, FOUND THAT EXCESSIVE FORCE WAS REQUIRED TO ACTIVATE THE RELEASE SYSTEM USING THE INTERIOR HANDLE. ALSO, THE TAIL CONE DID NOT DROP. FOUND…
- 6 Dec 1995
Retract Mech, malfunctioned
LANDING GEAR WOULD NOT EXTEND ON APPROACH INTO DTW. LOWERED GEAR BY UTILIZING EMERGENCY EXTENSION PROCEDURES. EXECUTED GO-AROUND AND ACCOMPLISHED SUCCESSFUL…
- 25 Dec 1994
Drive Cylinders, inoperative
AIRCRAFT ROLLED TO RIGHT DURING SLAT EXTENSION. LANDING WAS UNEVENTFUL. REPLACED SLAT DRIVE CYLINDERS. OPERATIONAL CHECK GOOD.