N776MS
2004 Embraer ERJ 170-100 SE standard FAA →
registration
- 2004
NTSB
- 14 Aug 2023
accident, Eleroy IL
service difficulty reports
11 reports
- 30 Jul 2026
Door, no discrepancy
L1 DOOR DIFFICULT TO OPEN AND STICKS ACCORDING TO GATE AGENT WHO REQUESTED IT BE LOOKED AT BY MX. OPENED & CLOSED L1 DOOR MULTIPLE TIMES IN REF WITH AMM SDS…
- 4 Jul 2026
Warning Message, false activation
BRAKE RT & LT FAULT MESSAGE DISPLAYED ON EICAS WHEN MLG EXTENDED. WENT AROUND AND RAN QRH PROCEDURE. BOTH LEFT AND RIGHT BRAKE PEDALS WERE VERY DULL AND…
- 1 Jul 2024
Bleed Air Sys, leaking
ENG 1 BLEED LEAK IN FLIGHT, FL280 FOLLOWED QRM PROCEDURES, AND UNABLE TO MAINTAIN CABIN PRESSURE DUE TO PACK 2 MEL. RETURN TO ORD EMERGENCY DECLARED/NO…
- 23 Jun 2024
Anti-Ice Valve, leaking
BLEED 2 LEAK ON CLIMBOUT PASSING THROUGH 10,000 FT DECLARED EMERGENCY. OVERWEIGHT LANDING NO INJURIES REPORTED. WHILE TROUBLESHOOTING BLEED TWO LEAK, FOUND…
- 1 Oct 2023
Floor Support, corroded
FLOOR BOARD SUPPORT AT FR 78 BTWN STGRS 29L-29R CORRODED (LEVEL 2 CORROSION).-C/A-REMOVED AND REPLACED FLOOR BOARD SUPPORT AT FR 78 BTWN STGR 29L-29R IAW EMB…
- 1 Oct 2023
Shear Tie, corroded
SHEAR CLIP AT FR 78 BTWN STGRS 28L-29L CORRODED.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED SHEAR CLIP AT FR 78 BTWN STGRS 28L-29L IAW EMB 170 SRM 51-40-08.
- 28 Sep 2023
Floor Support, corroded
FWD GALLEY RH FLOOR SUPPORT HAS EVIDENCE OF CORROSION BETWEEN FR 17 AND FR 18.(LEVEL 2 CORROSION) -C/A-REMOVED AND REPLACED FWD GALLEY RH FLOOR SUPPORT…
- 28 Sep 2023
Seat Track, corroded
SSI 53-10-027 LH LOWER INBD SEAT TRACK BEAM HAS EVIDENCE OF CORRODED BETWEEN FR 19 AN FR 20 (LEVEL 2 CORROSION).-C/A-REMOVED AND REPLACED LH LOWER INBD SEAT…
- 28 Sep 2023
Shear Panel, corroded
SSI 53-10-027 FWD GALLEY LH SHEAR PANEL BETWEEN FR 19 AND FR 20 HAS EVIDENCE OF CORROSION. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED FWD GALLEY LH SHEAR…
- 28 Sep 2023
Floor Support, corroded
SSI 53-10-027 FWD GALLEY RH SHEAR PANEL BETWEEN FR 12 AND FR 14 CORRODED.(LEVEL2 CORROSION)-C/A-REMOVED AND REPLACED FWD GALLEY RH SHEAR PANEL BTW FR 12-14…
- 2 May 2023
Proximity Sensor, failed
TROUBLESHOOTING LOG PG 4980597 ITEM 1 "AFTER TAKE OFF, GEAR LEVER COULD NOT BE MOVED UP. NO EICAS MESSAGE NOTED." - FOUND NLG WOW SENSOR 1 HARNESS CORRODED AT…