N77535
2016 Boeing 737-824 standard FAA →
registration
- 2016
earlier registrations
1 past record
service difficulty reports
24 reports
- 13 Aug 2026
Acm, seized
AIR RETURN FOR SMOKE/FUMES IN THE COCKPIT. TROUBLESHOOTING COCKPIT SMOKE/ODOR IAW AMM 05-51-26-800-801-C1. NO SMOKE/ODOR DETECTED. LEFT PACK TRIP LIGHT COMES…
- 26 Jan 2026
Oven, contaminated
OVEN SMELLS BAD, FWD GALLEY OVEN 204 INOPERATIVE. PULLED AND COLLARD CIRCUIT BREAKER. OVEN 204 INOP. BAD ODOR IS FROM FOOD. COMPLIED WITH NEF 2510AU OPS CHKD…
- 15 Nov 2025
Cover, loose
FA REPORTS THAT THE 2L EMERGENCY SLIDE PLASTIC COVER IS LOOSE AND THE SLIDE HANGS TOO LOW. INSPECTED BOTH AFT DOOR SLIDES, NO DEFECTS NOTED, SLIDE COVERS…
- 15 Oct 2025
Quick Disconnect, leaking
HYD PUMP LOW PRESSURE SYS B ENG 2. HYD PUMP SWITCH IS OFF. RAN ENG NR 2. HYD PUMP LOW PRESSURE LIGHT ON SYS B ENG 2 & NO PRESSURE IND. R & R ENG 2 EDP IAW AMM…
- 6 Aug 2025
Light, missing
THERE IS A HOLE WHERE EMERGENCY LIGHT SHOULD BE. FLOOR PROXIMITY LIGHT ASSEMBLY REPLACED. OPS CHECK OK. EMERGENCY LIGHTS OPS TESTED IAW 33-51-00-720-801.
- 21 Jul 2025
Switch, faulted
LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF GREEN AND RED LIGHTS ALL ILLUMINATED. DEBRIEFED CREW ON ARRIVAL. LANDING GEAR DID NOT RETRACT WITH GEAR HANDLE IN…
- 10 Jul 2025
Lamp, no test
EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. R/H AFT OVERWING EMERGENCY LIGHT INOP. LAMP REPLACED, OP CHECK GOOD IAW: 33-51-04-960-801.
- 9 May 2025
Unknown, odor
PUNGENT SMELL IN COCKPIT AND CABIN AIRBORNE NOTICED WHISP OF WHI TE SMOKE ON TAKEOFF PERFORMED HIGH POWER RUN NO SMELL NOTICED ACFT OK TO RETURN TO SERVICE…
- 25 Apr 2025
Skin, cracked
EXTERNAL GROUND POWER DOOR CUTOUT HAS GOUGE AT AFT CENTER SECTION. ACCOMPLISHED REPAIR AT EGPR AFT CENTER SECTION IAW SRM 53-10-15-2R-4. SFR NO. 805.
- 24 Apr 2025
Panel, gouged
L/W L/E SLAT #4 PANEL AFT OF ACTUATOR PANEL DEEP GOUGE I/B END REF AAR A/R 9954724 ESFR ENTRY. L/W L/E SLAT #4 PANEL AFT OF ACTUATOR PANEL DEEP GOUGE I/B END…
- 15 Apr 2025
Shield, corroded
AFT CARGO DOOR CUTOUT FWD SHIELD CORROSION AROUND NUTPLATES AT LOWER SURFACE REF AAR N/R 9955164 ESFR ENTERED. REMOVED AND REPLACED AFT CARGO DOOR CUTOUT FWD…
- 10 Apr 2025
Floorbeam, corroded
ACCOMPLISHED REPAIR AT STA 947.5 RBL 51 FLOOR BEAM REF SRM 53-70-51-2R-5 REPAIR 5 REF AAR N/R 9954833 ESFR COMPLETED ACCOMPLISHED REPAIR AT STA 947.5 RBL 51…
- 2 Apr 2025
Angle, cracked
{ B737-06-3-0030 } W/W LH STA 663 LBL 7" VAPOR BARRIER UPPER ANGLE CRACKED REF AAR N/R 9954773 ESFR INFORMATION ADDED. ACCOMPLISHED REPAIR AT L/H VAPOR…
- 2 Apr 2025
Angle, cracked
W/W RH STA 663 RBL 7" VAPOR BARRIER UPPER ANGLE CRACKED REF AAR N/R 9954772 ESFR CREATED AND SUBMITTED. CORRECTIVE ACTION: REMOVED AND REPLACED UPPER ATTACH…
- 31 Mar 2025
Structure, corroded
{B737-06-3-0049} CABIN AFT WET AREA L/H INNER CHORD, IS CORRODED FROM STA. 955 TO STA. 98.5 REF AAR N/R 9954829 REMOVED AND REPLACED CABIN AFT WET AREA INNER…
- 23 Jan 2025
Slide, damaged
SLIDE PACK DAMAGED DOOR 1R INSPECTED SLIDE PACK OF 1R DOOR AND FOUNDED WITHIN LIMITS IN REF TO AMM TASK 25-66-01-400-804, NO FURTHER DEFECTS NOTED AT THIS TIME.
- 7 Aug 2024
Indicator, unreliable
REJECTED TAKEOFF DUE TO AIRSPEED UNRELIABLE AMBER LGT. CA INDICA TOR 55KTS FO INDICATOR 85KTS SEE LOG 7981417 FOR CAPTAINS PITOT TUBE REPLACED DUE TO BEING…
- 1 Jul 2024
Light, damaged
SEAT MOUNTED EMERGENCY LIGHT AT ROW 11ABC MISSING. REMOVED AND REPLACED EMERGENCY LIGHT REF MM 33-51-11. OPS CK OK. VERIFIED INSTALLATION AND OPERATIONAL…
- 23 Sep 2019
Computer, inoperative
TCAS FAIL FLAG ON NAVIGATION DISPLAY SHOWS WITH ATC TRANSPONDER SELECTOR AT TA AND SHOWS WITH SELECTOR AT TA/RA FLAG DISPLAYED IN POSITION 1 AND POSITION 2…
- 24 Dec 2017
Flashlight, no test
FWD GALLEY FLASHLIGHT FAILED TO TEST .
- 22 Sep 2017
Sign, missing
EMERGENCY EXIT SIGN MISSING AT KNEE AREA OF SEAT 20A. REPLACED EMERGENCY LIGHT ASSY IAW AMM 33-51-01-960-802. OK FOR SERVICE.
- 11 Sep 2017
Lens, missing
BS 712 CABIN FWD CLOSET EMERGENCY LIGHT LENS MISSING. LIGHT OPS OK. REPLACED THE MISSING LENS IAW AMM 33-51-14-960-801. OPS CHECKED OK
- 11 Aug 2017
Engine, fod
WHILE SITTING ON TAXIWAY, THE ENGINE INGESTED HUGE PIECE OF ROLLING PLASTIC. THE ENGINE FAILED, PERFORMED A VISUAL FOD INSPECITON OF THE NR 1 ENGINE IAW AMM…
- 27 Feb 2017
Fuel Cell, overserviced
FUEL COMING FROM RIGHT WING TIP AND F/A REPORT FUEL ODOR IN GALLEYS. TANK WAS OVERSERVICED AND FUEL CAME FROM SURGE TANK DURING TAXI, REDISTRIBUTED FUEL. NO…