- 23 Aug 2026
Fuse, inoperative
EMERGENCY LIGHT, AFT OF RT WING ROOT INOPERATIVE. RELAMPED NO HELP IAW AMM 33-51-04-960-801. REMOVED AND REPLACED EMERGENCY BATTERY CHARGER (M1671) FUSE AMM…
- 23 Aug 2026
Panel, fom
REMOVED DADO PANEL FOR ACCESS TO EMERGENCY LIGHT BATTERY (M1671), ROW 27DEF. RE-INSTALLED DADO PANEL AT ROW 27DEF IN REF AMM 03-25-00.
- 19 Apr 2026
Oven, odor
OVEN 205 BEGAN TO SMOKE BEFORE COOKING FA PULLED BREAKER TO STOP THE SMOKE. OPERATED OVEN FOR 20 MINUTES, NO EVIDENCE OF SMOKE OR ODOR, INSPECTED…
- 12 Mar 2026
Hinge, dirty
MANUAL LANDING GEAR EXTENSION DOOR WONT STAY CLOSED FOUND HINGE AREA FOR DOOR DIRTY AND LOCKING CLIPS AREA DIRTY CLEANED BOTH AND RE-ALIGNED DOOR. DOOR OPS…
- 30 Nov 2025
Service Panel, missing
RAMP REPORTS LAV SERVICE PANEL IS MISSING. INSPECTED TAIL SECTION AFT OF CUTOUT AND STAB AREA. NO FURTHER DAMAGE NOTED. COMPLETED INSTALLATION WASTE TANK…
- 29 Oct 2025
Support Beam, damaged
PREVIOUS REPAIR DAMAGE AT LOWER SUPPORT BEAM LOWER CHORD AT RBL 40.875. REMOVED PREVIOUS REPAIR SRM 51-40-02 MATERIAL IN 7075 T6 .125 THICK PO # 3919569330 AS…
- 30 May 2025
Proximity Switch, dirty
AFT ENTRY CAUTION LIGHT ILLUMINATED AFTER INITIATING TAKEOFF ROLL EXAMINED DOOR 2 L FOUND HANDLE NOT PROPERLY CLOSED. CHECKED FOR PROPER OPERATION OF ENTRY…
- 24 Feb 2025
Light, detached
EMERGCY EXIT LT ON TRIM BOTTOM RT SIDE LAV D WONT STAY IN. HANG ING IN AISLE BY ITS CORD. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC…
- 6 Feb 2025
Warning Light, false activation
AT FL 220 ON DESCENT AFT ENTRY AND AFT LGHTS CAME ON W/TAKE OFF CONFI G LGHT. DEBRIEFED CREW INDICATION LIGHTS FOR DOOR 2L AND 2R CAME ON MOMENTARY AND…
- 30 Aug 2024
Skin, damaged
R/H #1 FLIGHT DECK WINDOW POST CUT IN INCORRECT SPOT, ONE FASTENER (1") LOWER THAN SHOWN REF EA 5310-04554 OP 8 FIGURE 6 SHT 4. BLOCK 29 STEP (14).(C)…
- 23 Aug 2024
Stringer Splice, damaged
INSPECT FUSELAGE TYPE III STRINGER, SPLICE REPAIR @ #5R STRINGER STA727A-727C PER SRM53-00-03-2R-3, PARAGRAPH 5.A(2). REF BAM N/R 2144286 FOR REPAIR DETAILS…
- 19 Aug 2024
Pressure Blkhd, cracked
VERTICAL PRESSURE DECK WEB HAS A 1/2" CRACK AT STA.663 AND LBL.34 PER SRM. REPAIRED PER SRM 57-10-10-2R-3 AT IHC HEAVY CHECK VISIT ON BAM NON-ROUTINE 2119360.…
- 19 May 2024
Power Supply, inoperative
FIRST CLASS AND EXT DOOR 1R EMERGENCY LIGHTS INOP DURING LIGHTS CHECK. NEEDS CHARGER AND BATTERY M1674 REMOVED AND REPLACE BATTERY AND POWER SUPPLY PER REF…
- 8 May 2024
Engine, overheated
NO.2 OVRHEAT LT ILLUM IN FLT. SEE RELATED FIM 26-10 TASK 811. PERFORMED FIM TASK 26-10 TASK 801. NO FAULTS FOUND. PERFORMED FIM TASK 26-10 TASK 811 ( EXCEPT…
- 18 Mar 2024
Proximity Sensor, faulty
LE FLAP TRANSIT LIGHT ON PERFORMED FLAPS 15 LANDING LE FLAP TRANSIT PROCED IAW FLIGHT CREW: LE FLAPS IN TRANSIT LIGHT AND SLAT/FLAP MOVEMENT WORKED NORMALLY…
- 17 Feb 2024
Duct, cracked
PRESSURIZATION CANNOT KEEP THE CORRECT CABIN PRESSURE AT FL340 DIFF PRESSURE ONLY6.5 CABIN ALT TO 10K FT OUTFLOW APPEA REDFULLCLS PERFORMED PRESSURIZATION…
- 16 May 2022
Vortex Gen, damaged
2 VORTEX GENERATORS ARE BROKEN ON FO SIDE OF NOSE DEF PER CDL DEFERRED PER CDL 53A. TOMC OK SEE PIC. DEF PER CDL
- 16 May 2022
Blades, missing
PDA 2 2 CAB GENERATORS MISSING FINS. DEF PER CDL
- 18 Nov 2021
Slat System, faulted
*EMERGENCY DECLARED*LEADING EDGE FLAPS AND SLATS DO NOT EXTEND DURING NORMAL SYSTEM OPERATION FLAP POSITION INDICATOR STOPPED AT 10 DEGREES WITH HANDLE AT…
- 22 Apr 2019
Guide Arm, damaged
FWD DOOR 1L WILL NOT OPEN. DEPLANING THROUGH AFT DOOR 2L. NEE D MX UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE INSPECT & CALL MX CTRL. MAC METER…
- 29 Jul 2018
Pressure Panel, cracked
LOCATED A 2" CRACK BETWEEN RBL 25.00 AND RBL 31.83 ON RIGHT CENTER VERTICAL PRESSURE WEB. REPAIR AS PER SRM 57-10-10 REPAIR 3 CAT B.
- 25 Nov 2017
Battery Pack, discharged
FOUND FWD LEFT DOOR EMERG EXIT LIGHT INOP. REMOVED & REPLACED LEFT BATTERY PACK, OPS CHECK NORMAL.
- 24 Jul 2017
Lens, missing
EMERGENCY LIGHT COVER MISSING AT THE R2 DOOR. REPLACED LENS
- 6 Sep 2016
Indication Sys, malfunctioned
RECEIVED FUEL IMBALANCE WARNING DURING CRUISE. FUEL QUANTITY CONTINUED TO INDICATE AN INCREASED LOSS APPROX 200 LBS IN 10 MINUTES, SHUT DOWN NR 1 ENG IAW…
- 24 Mar 2015
Light, inoperative
FOUND ON INBOUND L2 OUTSIDE EMER LIGHT FAILS TO ILLUMINATE. R & R L2 OUTSIDE EMER LIGHT. LAMP INSTALLATION CHECKED GOOD IAW AMM 33-51-04.
- 29 Nov 2013
Vapor Barrier, cracked
DURING INSPECTION, FOUND 15 INCH CRACK IN BS 663 VAPOR WEB FIBERGLASS PANEL BETWEEN LBL 29 - 40, BETWEEN WL 148 - 161. REPAIRED CRACK IAW SRM 51-70-04, REPAIR…
- 29 Nov 2013
Vapor Barrier, cracked
DURING INSPECTION, FOUND 15 INCH CRACK IN BS 663 VAPOR WEB FIBERGLASS PANEL BETWEEN LBL 29 AND LBL 40, BETWEEN WL 148 AND WL 161. REPAIRED VAPOR WEB…
- 29 Nov 2013
Vapor Barrier, cracked
DURING INSPECTION, FOUND 10" CRACK IN BODY STA. 663 VAPOR WEB FIBERGLASS PANEL BETWEEN RBL 31 & 37, BETWEEN WL 150 AND WL 158. REPAIRED CRACK IN VAPOR WEB…
- 29 Nov 2013
Panel, cracked
APPROXIMATE 10 INCH CRACK IN CTR WING REAR SPAR VAPOR WEB FIBERGLASS PANEL BETWEEN RBL 31 & RBL 37 & BETWEEN WL 150 & WL 158. REPAIRED CRACK IN CTR WING REAR…
- 29 Nov 2013
Panel, cracked
APPROXIMATE 15 INCH CRACK IN CTR WING REAR SPAR VAPOR WEB FIBERGLASS PANEL BETWEEN WL 148 & WL 161. REPAIRED CRACK IN CTR WING REAR SPAR VAPOR WEB FIBERGLASS…
- 21 Feb 2012
Unknown, smoke
LARGE AMOUNT OF SMOKE CAME OUT OF CIRCUIT BREAKER PANEL (RADIO-NAV), BEHIND CAPTAIN'S SEAT AT ARRIVAL AT GATE. OPENED CP WINDOW AND SMOKE IMMEDIATELY CLEARED.…
- 14 Mar 2011
Unknown, odor
WHILE BEING TOWED OFF THE GATE BEFORE STARTING ENGINES THE F/A CALLED TO REPORT A "BURNED RUBBER" SMELL EMINATING FROM MID CABIN NEAR EXIT ROWS. COULD NOT…
- 6 Nov 2009
Actuator, faulty
OXYGEN MASK WILL NOT DEPLOY AT SEAT 17EFG WHEN ELECTRICALLY OPERATED FROM FLIGHT DECK. REMOVED & REPLACED ROW 17EFG OXYGEN SOLENOID ACTUATOR IAW MM 35-22-21,…