N7667A
1992 Boeing 757-223 standard FAA →
reservations
earlier registrations
1 past record
- 1992
service difficulty reports
62 reports
- 24 Jun 2013
Module, failed
FIRST CLASS SEAT MOUNTED EMERGENCY LIGHTS, LT & RT NR ONE DOORS LOWER EMERGENCY LIGHTS INOPERATIVE. INSTALLED CHARGER MODULE. OPERATIONS CHECKED NORMAL
- 24 Jun 2013
Battery, discharged
FIRST CLASS SEAT MOUNTED EMERGENCY LIGHTS, LT & RT NR ONE DOORS LOWER EMERGENCY LIGHTS INOPERATIVE. INSTALLED NEW BATTERY. OPERATIONS CHECKED NORMAL
- 16 Feb 2013
Light, inoperative
EQUIPMENT COOLING PUSH BUTTON SWITCH "OVERHEAT LIGHT" BURNED OUT. REPLACED LAMP FOR EQUIPMENT COOLING PUSH BUTTON SWITCH. OPS CHECK NORMAL.
- 16 Feb 2013
Light, inoperative
SEAT 22D EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP FOR SEAT 22D EMERGENCY LIGHT. OPS CHECK NORMAL.
- 16 Feb 2013
Connector, loose
RIGHT EMERGENCY BOTTLE SQUIB CONNECTOR BACKSHELL STRAIN RELIEF LOOSE. TIGHTENED RIGHT EMERGENCY BOTTLE SQUIB PLUG BACKSHELL. OPS CHECK NORMAL.
- 9 Jul 2012
Battery, defective
FIRST CLASS RIGHT SEAT MOUNTED EMERGENCY LIGHT STAY ON WITH POWER OFF. REPLACED BAD BATTERY ON BATTERY PACK. OPS CHECK NORMAL.
- 24 May 2012
Wire, damaged
EMERGENCY LIGHTING SYSTEM FROM ROWS 26D TO 36D INOPERATIVE. REPAIRED DAMAGED WIRE AT EMERGENCY LIGHT ASSEMBLY AT RIGHT NUMBER 4 DOOR, OPS CHECK NORMAL.
- 2 May 2012
Skin, corroded
CORROSION WAS FOUND ON THE RIGHT INBOARD MAIN FLAP AT THE UPPER SKIN. INSTALLED DOUBLER PER EA B757-57-023402.
- 29 Apr 2012
Actuator, failed
LEFT OFF WING SLIDE PNEUMATIC DEPLOYMENT SYSTEM FAILED OPERATIONAL CHECK. REPLACED LEFT OVERWING SLIDE DOOR ACTUATOR. OPS CHECK NORMAL.
- 29 Apr 2012
Frame, corroded
AFT CARGO FRAME AND SHEAR TIE AT STATION 1460 LEFT BUTTLINE 3 CORRODED. INSTALLED DOUBLER PER EA B757-53-023400.
- 28 Apr 2012
Hinge Fitting, cracked
NUMBER 2 PYLON OUTBOARD HINGE FITTING UPPER AFT HOLE HAS TWO CRACK INDICATIONS. INSTALLED DOUBLER PER EA B757-54-023384.
- 25 Apr 2012
Door, worn
FORWARD CARGO DOOR LOWER FLANGE HAS SEVERAL NICKS, DENTS AND CHAFED SPOT ENTIRE LENGTH OF FLANGE SECTION. REPLACED CORNER PER SRM 51-40-02.
- 25 Apr 2012
Intercostal, corroded
BULK CARGO COMPARTMENT, INTERCOSTAL UPPER ANGLE CORRODED FROM BODY STATIONS 1480 TO 1500 STRINGERS 25 TO 26 RIGHT. REPLACED INTERCOSTAL PER SRM 51-40-02.
- 19 Apr 2012
Skin, dented
RIGHT WING INBOARD MID FLAP UPPER SURFACE DENTED CLUSTER IN THE CENTER. ACCOMPLISHED BONDED REPAIR PER SRM 57-53-01.
- 19 Apr 2012
Skin, dented
NUMBER 1 SLAT DENTED SEVERAL PLACES. REPAIRED DENTS BY REMOVING DAMAGE AND BONDING NEW SKINS AND DOUBLERS PER SRM 57-43-02 AND 51-70-10.
- 18 Apr 2012
Intercostal, corroded
BULK CARGO COMPARTMENT INTERCOSTAL CORRODED AT BODY STATIONS 1600 TO 1620, STRINGER 29 TO 30 RIGHT. REPLACED INTERCOSTAL PER SRM 51-40-02 AND BAC DWG 146N5451.
- 18 Apr 2012
Intercostal, corroded
BULK CARGO COMPARTMENT, INTERCOSTAL CORRODED FROM BODY STATIONS 1600 TO 1620, STRINGERS 29 TO 30 LEFT. REMOVED CORROSION AND REPLACED INTERCOSTAL PER SRM…
- 16 Apr 2012
Intercostal, corroded
AFT CARGO COMPARTMENT LEFT INTERCOSTAL FROM BODY STATION 1480 TO 1500, STRINGER 26 LEFT HAS CORROSION. REMOVED AND REPLACED CHORD PER SRM 51-40-02.
- 15 Apr 2012
Skin, corroded
NUMBER 3 SLAT LEADING EDGE SKIN SIX FEET FROM THE OUTBOARD END IS CORRODED. REMOVED DAMAGE AND FABRICATED A FLUSH REPAIR PER AARD 57-43-01-2.
- 9 Apr 2012
Floor Support, corroded
MAIN CABIN FLOOR SUPPORT ANGLE AND SILL SUPPORT PLATE CORRODED UNDER DOOR DRAIN PLATE FROM BODY STATIONS 676 TO 740, RIGHT BUTTLINES 62 TO 65. REMOVED AND…
- 7 Apr 2012
Floor Support, corroded
MAIN CABIN FLOORBOARD ATTACH ANGLE CORRODED FROM BODY STATIONS 1597 TO 1600 LEFT BUTTLINE 63. REMOVED AND REPLACED DAMAGE ATTACHED ANGLE PER AARD 53-60-73-1.
- 7 Apr 2012
Floor Support, corroded
MAIN CABIN FLOOR SUPPORT ANGLE AND SILL SUPPORT STRUCTURE CORRODED UNDER DRAIN PLATE FROM BODY STATIONS 676 TO 740, LEFT BUTTLINES 61 TO 64. REMOVED AND…
- 17 Feb 2012
Engine, failed
CREW REPORTED ON INITIAL DESCENT WHEN THROTTLES STARTED BACK THEY FELT A THUMP AND SAW THE LEFT ENGINE HAD FLAMED OUT. UNCOMMANDED ENGINE SHUTDOWN (SINGLE…
- 1 Jul 2011
Probe, defective
BDA - CREW REPORTED RIGHT ENGINE PRESSURE RATIO INDICATION FAULT. EMERGENCY DECLARED FLIGHT RETURNED BDA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM…
- 11 Jan 2011
Fitting, corroded
CORROSION ON G1 FLOOR FITTING. REMOVED AND REPLACED FLOOR FITTING.
- 4 Jan 2011
Skin Panel, dented
DENT IN LEFT SKIN PANEL, JUST AFT OF RADOME. CUT OUT DAMAGE AND REPAIRED IAW EA B757-53-014838 AND SRM 53-00-011-2R3.
- 24 Oct 2010
Power Supply, inoperative
LEFT AFT OFF WING LIGHT L568 INOPERATIVE. REPLACED M735 POWER SUPPLY ASSEMBLY. OPS CHECKS GOOD.
- 23 Oct 2010
Lens, missing
SEAT 26D ESCAPE PATH LIGHT LENS MISSING. REPLACED LENS FOR ESCAPE PATH LIGHT AT 26D. OPS CHECK NORMAL.
- 23 Oct 2010
Light, inoperative
SEAT 33D ESCAPE PATH LIGHT LAMP INOPERATIVE. REPLACED LAMP FOR ESCAPE PATH LIGHT AT SEAT 33D. OPS CHECK NORMAL.
- 29 Sep 2009
Light, inoperative
RIGHT NUMBER 2 DOOR EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY AT RIGHT NUMBER 2 DOOR. OPS CHECK OK.
- 29 Sep 2009
Charger, inoperative
PATHWAY EMERGENCY LIGHT FROM SEAT ROWS 9D TO 16D INOPERATIVE. REPLACED BATTERY PACK AND MODULE CHARGER.
- 25 Sep 2009
Valve, failed
TWO HOURS INTO THE FLIGHT THE PARKING BRAKE LIGHT WITH THE ASSOCIATED EICAS MESSAGE ILLUMINATED. LANDED LAX WITHOUT INCIDENT. REPLACED PARKING BRAKE VALVE.
- 11 Sep 2009
Module, inoperative
FIRST CLASS SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. REPLACED MODULE FOR SEAT MOUNTED EMERGENCY LIGHTS IN FIRST CLASS. OPS CHECK OK.
- 11 May 2009
Unknown, unknown
ELEVATOR SYMETRY STATUS MESSAGE DURING CLIMBOUT. RETURNED ORD WITHOUT INCIDENT. RESET FAULT BALL AND PERFORMED THE REST OF THA SAM BITE PROCEDURE AND THE…
- 9 Dec 2008
Connector, loose
EMERGENCY LIGHT AT OVERHEAD SEAT ROW 11D INOPERATIVE. FOUND LOOSE CONNECTOR AND SECURED CONNECTOR AT OVERHEAD SEAT ROW 11D. SYSTEM GROUND CHECKED NORMAL…
- 13 Oct 2008
Lamp, burned out
MIA - EMERGENCY LIGHT AT SEAT ROW 5 INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT ROW 5. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 23 Dec 2007
Light, broken
MIA - EMERGENCY LIGHT AT SEAT 24D INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT SEAT 24D. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 14 Nov 2007
Slide, dislodged
SXM - EMERGENCY SLIDE AT LEFT NUMBER ONE DOOR DISLODGED FROM SLIDE STORAGE PACK AND WAS SUPPORTED BY JETBRIDGE NOT ACTIVATING INFLATION SEQUENCE. SLIDE DID…
- 17 Jun 2007
Bulb, burned out
MIA - EMERGENCY EXIT LIGHT AT SEAT 14D INOPERATIVE. RELAMPED EMERGENCY EXIT LIGHT AT SEAT 14D. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 23 Mar 2007
Battery Pack, inoperative
MIA - EMERGENCY LIGHTS AT ROW 17D TO 25D INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT ROW 17D TO 25D. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 20 Sep 2006
Battery Pack, inoperative
SFO - EMERGENCY LIGHTS AT ROWS 17 THROUGH 25 INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY PACK AND CHARGER FOR INOPERATIVE EMERGENCY LIGHTS AT SEAT ROWS 17…
- 28 Nov 2002
Circuit Breaker, damaged
MIA - EMERGENCY ESCAPE SLIDE SQUIB TEST INOPERATIVE. FOUND LEFT GENERATOR CIRCUIT BREAKER WITH BROKEN 'A' PHASE TERMINAL. REPLACED CIRCUIT BREAKER. SYSTEM…
- 26 Jul 2002
Slide, deployed
TUL - FLT 9603 - EN ROUTE TUL-DFW - AFTER TAKEOFF, RECEIVED EICAS MESSAGE FOR LEFT WING SLIDE PROBLEM. DURING LANDING, AIRCRAFT REQUIRED QUARTER WHEEL…
- 12 May 2002
Receiver, inoperative
MIA - FLT 860 - EN ROUTE MIA-LGA, AIRCRAFT INTERRUPTED BACK TO MIA DUE TO WEATHER RADAR INOPERATIVE. REPLACED WEATHER RECEIVER PER MM. ACCOMPLISHED ADJUSTMENT…
- 24 Jan 2001
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD SECTION EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL…
- 7 Aug 2000
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, RIGHT FORWARD SIDEWALL EMERGENCY EXIT LIGHT INOPERATIVE. REPAIRED BROKEN WIRE. SYSTEM GROUND CHECK NORMAL OPERATION. (M)
- 29 Nov 1999
Connector, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT 1E AND FORWARD OF 9E INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT…
- 28 Nov 1999
Connector, damaged
TPA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT AT ROWS 1E AND 6E INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR AT ROW…
- 1 May 1998
Connector, dirty
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT MOST FORWARD CABIN CENTER POSITION INOPERATIVE. CLEANED EMERGENCY EXIT LIGHT ASSEMBLY CONNECTORS.…
- 24 Mar 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 407 RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668872. REPAIRED PER MRB NR 757-1109. (M)
- 24 Mar 1997
Seat Track, corroded
AFW - SEAT TRACK AT STATION 377 LBL 45 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668871. REPAIRED PER MRB NR 757-1108. (M)
- 24 Mar 1997
Pan, gouged
AFW - R-4 DOOR HANDLE PAN HAS GOUGE BEYOND SRM LIMITS, E58 1668902. REPAIRED PER MRB NR 757-1110. (M)
- 24 Mar 1997
Floorbeam, corroded
AFW - FLOORBEAM AT STATION 395 RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS, E58 NR 1668874. REPAIRED PER MRB NR 757-1106. (M)
- 24 Mar 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 332 RBL 3 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668880. REPAIRED PER MRB NR 757-1105. (M)
- 24 Mar 1997
Floorbeam, corroded
AFW - FLOORBEAM AT STATION 377 RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS, E58 NR 1668877. REPAIRED PER MRB NR 757-1104. (M)
- 24 Mar 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 373 RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS, E58 NR 1668876. REPAIRED PER MRB NR 757-1103. (M)
- 24 Mar 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 393 RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS, E58 NR 1668875. REPAIRED PER MRB NR 757-1102. (M)
- 24 Mar 1997
Floorbeam, corroded
AFW - FLOORBEAM AT STATION 365 LBL 60 AND RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668888 AND 1669025. REPAIRED PER MRB NR 757-110. (M)
- 24 Mar 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 404 RBL 55 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668873. REPAIRED PER MRB NR 757-1100. (M)
- 21 Mar 1997
Floorbeam, corroded
AFW - FLOORBEAM AT STATIO 324, RBL 61 HAD CORROSION BLENDED BEYOND SRM LIMITS E58NR 1668879. REPAIRED PER MRB NR 757-1107. (M)
- 20 Sep 1996
Floor Beam, corroded
AFW - FOUND SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS ON FLOOR BEAM AT STATION 1640. PER MRB 757-954. (M)
- 18 Apr 1996
Wire, defective
DFW - DURING OVERNIGHT CHECK, SHORT SECTION OF EMERGENCY FLOOR LIGHT AT MID-CABIN FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT FLAT CONDUCTOR WIRE AT…