N7546A
Boeing 720-023B FAA →
earlier registrations
2 past records
- 1990
service difficulty reports
89 reports
- 22 Oct 2014
Battery Pack, discharged
EGRESS POWER SUPPLY, AB4-5 FAILED TEST. REPLACED BATTERY PACK. OPERATIONS CHECKED NORMAL.
- 5 Oct 2014
Door Seal, obstructed
AIRCRAFT SLOW TO PRESSURIZE. EMER DECLARED FLIGHT RETURNED & LANDED WITHOUT INCIDENT. REMOVED DEBRIS FROM AFT CARGO DOOR SEAL DEPRESSOR AREA & PRESS CHECKED…
- 9 Sep 2014
Longeron, cracked
LONGERON 25 CRACKED AT STATION 160. ACCOMPLISHED REPAIR IAW SRM 53-02-00.
- 27 Aug 2014
Tire, separated
FLIGHT CREW RECEIVED CALL FROM ATC FOR POSSIBLE BLOWN TIRE ON TAKEOFF. EMER DECLARED FLIGHT LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. AFTER…
- 2 Dec 2013
Portable Light, inoperative
LT NR 1 DOOR PORTABLE EMERGENCY LIGHT FAILED TEST. REPLACED LIGHT ASSEMBLY. OPERATIONS CHECKED NORMAL.
- 10 Jul 2013
Light, damaged
FORWARD EMERGENCY LIGHT IN AFT STAIR WELL DAMAGED. REPLACED LAMP FOR FORWARD EMERGENCY LIGHT IN AFT STAIR WELL. OPERATIONS CHECKED NORMAL.
- 16 May 2013
Switch, inoperative
CREW REPORTED LANDING GEAR UNSAFE INDICATION. EMERGENCY DECLARED, FLIGHT LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED S1-89 GEAR HANDLE…
- 1 Jan 2013
Battery Pack, discharged
SEAT MOUNTED EMERGENCY LIGHTS FROM ROWS 9 TO 19DEF INOPERATIVE. REPLACED MODULE AND BATTERY PACK AT M10953.
- 19 Sep 2012
Battery Pack, discharged
ALL EMERGENCY LIGHTS IN FIRST CLASS CEILING INOPERATIVE. REPLACED ROW 6 BIN BATTERY PACK. OPS CHECK NORMAL.
- 19 Sep 2012
Battery Pack, discharged
EMERGENCY LIGHTS AT FORWARD GALLEY DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FORWARD GALLEY DOOR. OPS CHECK NORMAL.
- 17 Jan 2012
Casting, cracked
RIGHT WING GROUND SPOILER CASTING IN TRAILING EDGE OF WING IS CRACKED AT FORWARD OUTBOARD SIDE. INSTALLED NEW CASTING PER AARD 51-10-00-05.
- 17 Jan 2012
Frame, cracked
THE 1418 FRAME CRACKED AT LONGERON 2 LEFT. INSTALLED REPAIR DOUBLERS PER SRM 53-03-0.
- 26 Jul 2011
Duct, damaged
OKC - CREW REPORTED TAIL TEMPERATURE HIGH LIGHT ILLUMINATED DURING CLIMBOUT. EMERGENCY DECLARED FLIGHT RETURNED OKC LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED…
- 29 May 2011
Battery Pack, discharged
FORWARD OVERWING EMERGENCY EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD OVERWING EMERGENCY EXIT SIGN. OPS CHECK NORMAL.
- 15 Aug 2010
Skin, damaged
SKIN AROUND AUXILIARY POWER UNIT EXHAUST DUCT HAS HEAT DAMAGE STATION 1418. INSTALLED SKIN REPAIR DOUBLER PER EA MD80-53-012437.
- 12 Aug 2010
Frame, cracked
CRACK FOUND IN RADIUS OF FRAME STATION 864 RIGHT SIDE. COMPLETED INSTALL FRAME REPAIR PER SR 09530282 AND K3290AG AND SERVICE BULLETIN MD80-53A301.
- 12 Aug 2010
Web, damaged
DAMAGE IN LIGHTENING HOLE OF WEB STATION 862 ABOVE LONGERON 15. INSTALLED WEB REPAIR PER EA MD80-012389.
- 12 Aug 2010
Cargo Track, corroded
HEAVY CARGO / AFT- CORROSION ON RIGHT TIE DOWN TRACK FROM STATIONS 1212 TO 1322. INSTALLED NEW TIE DOWN TRACK PER SRM 51-30-01.
- 12 Aug 2010
Cargo Track, corroded
AFT CARGO CORROSION ON FORWARD RIGHT TIE DOWN TRACK BETWEEN STATIONS 1155 TO 1117. INSTALLED NEW TIE DOWN TRACK PER SRM 51-30-01.
- 11 Aug 2010
Cargo Track, corroded
HEAVY CARGO AFT CORROSION ON LEFT TIE DOWN TRACK FROM STATION 1007 TO 1220. INSTALLED NEW TIE-DOWN TRACK PER SRM 51-30-01.
- 11 Aug 2010
Cargo Track, corroded
HEAVY CARGO AFT CORROSION ON RIGHT TIE DOWN TRACK FROM STATIONS 1212 TO 1322. INSTALLED TIE DOWN TRACK PER SRM 51-30-01.
- 9 Aug 2010
Shear Tie, cracked
SHEAR TIE CRACKED AFT SIDE OF STATION 1451 LONGERON 2 LEFT. INSTALLED NEW SHEAR TIE PER AARD 51-00-00-012 SRM 51-30-05.
- 9 Aug 2010
Stiffener, cracked
STIFFENER AFT SIDE OF STATION 1451 CRACKED AT LONGERON 2 LEFT. INSTALLED NEW STIFFENER PER AARD 51-00-00-012 AND SRM 51-30-05.
- 9 Aug 2010
Fitting, corroded
LOWER FORWARD CORNER OF DOORWAY FITTING IS CORRODED. INSTALLED NEW FITTING PER DWG 5930483 AND AARD 51-00-00-012.
- 8 Aug 2010
Skin, cracked
SKIN CRACKED AT STATION 1380 ABOVE STRINGER 14 RIGHT. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 53-01-00.
- 8 Aug 2010
Cusp Web, corroded
CUSP MEMBRANE CORRODED AT FORWARD ENTRY IN SEVERAL PLACES BETWEEN STATION 180 AND 200. REPAIRED PER AARD 53-20-00-16.
- 8 Aug 2010
Seat Track, corroded
SEAT TRACK 5 OUTBOARD FLANGE CORRODED AT STATION 204. REMOVED AND REPLACED SEAT TRACK 5 STATION 200 TO 246 AND INSTALLED SPLICE PER SRM 53-05-00 FIGURE 4.
- 7 Aug 2010
Cusp Web, cracked
CRACK IN RIGHT CUSP STATION 219 UNDER NUMBER 5 SEAT TRACK. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 7 Aug 2010
Cusp Web, corroded
LEFT CUSP STATION 612 TO 615 CORROSION ON BOTTOM SIDE OUT OF LIMITS. INSTALLED NEW CUSP DOUBLER FROM STATION 608 TO STATION 630 LEFT PER AARD 53-20-00-16.
- 7 Aug 2010
Cusp Web, cracked
TWO CRACKS IN LEFT CUSP BETWEEN STATIONS 218 AND 237. REMOVED AND REPLACED LEFT CUSP SHEET BETWEEN STATIONS 218 AND 237 PER AARD53-20-00-16.
- 7 Aug 2010
Longeron, damaged
LONGERON 14 AT STATION 1410 HAS HEAT DAMAGE. REMOVED DAMAGED SECTION OF LONGERON 14 FROM STATION 1389 TO STATION 1435 AND INSTALLED A NEW SERVICEABLE SECTION…
- 6 Aug 2010
Fitting, corroded
AFT CARGO LOWER FORWARD CORNER DOORWAY FITTING IS CORRODED. INSTALLED NEW FITTING PER DWG 5930483 & AARD 51-00-00-012.
- 6 Aug 2010
Fitting, corroded
AFT CARGO LOWER AFT CORNER OF DOORWAY FITTING IS CORRODED. INSTALLED NEW FITTING AFT CORNER OF DOOR PER SRM 51-30-05.
- 6 Aug 2010
Cusp Web, corroded
SUB FLOOR WEB HAS CORROSION AND WORN SPOTS STATION 1136 TO 1174. INSTALLED LEFT CUSP DOUBLER REPAIR AND CUSP FILLER PER AARD 53-20-00-16 UNDER AFT GIRT BAR…
- 6 Aug 2010
Skin, cracked
FUSELAGE SKIN CRACKED BELOW FASTENER HOLE STATION 1380 ABOVE STR 14R. INSTALLED DOUBLER PER SRM 53-34-00.
- 6 Aug 2010
Membrane, corroded
FORWARD CABIN SUB FLOOR HAS CORROSION AT STATION 200 TO 208 RIGHT BUTTLINE 45 TO RIGHT BUTTLINE 56. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.
- 6 Aug 2010
Cusp Web, corroded
RIGHT CUSP AT STATION 620 TO 628 IS OUT OF MANUAL LIMITS. INSTALLED RIGHT CUSP DOUBLER AT STATION 620 TO 628 PER AARD 53-20-00-16.
- 6 Aug 2010
Cusp Web, corroded
LEFT CUSP STATION 518-519 CORROSION ON LOWER SIDE OUT OF LIMITS. REMOVED CORROSION PER AARD 53-20-00-16. INSTALLED DOUBLER AT LEFT CUSP STATION 518-519 PER…
- 5 Aug 2010
Skin, dented
DENT IN FUSELAGE SKIN STATION 252 ABOVE LONGERON 18 LEFT. REMOVED DAMAGE AND INSTALLED DOUBLER REPAIR PER SRM 53-04-00 FIGURE 38 SHEET 36.
- 5 Aug 2010
Cusp Web, corroded
CORROSION ON SUBFLOOR UNDER AFT SERVICE DOOR AFT GIRT BAR FITTING. REMOVED CORROSION AND INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.
- 5 Aug 2010
Cusp Web, corroded
CORROSION ON RIGHT CUSP STATION 620 TO 628. REMOVED CORROSION INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.
- 5 Aug 2010
Cusp Web, corroded
AFT CARGO CORROSION ON LOWER SIDE OF LEFT CUSP AT STATION 1140. INSTALLED CUSP REPAIR DOUBLER AT LEFT STATION 1140 PER AARD 53-20-00-16.
- 5 Aug 2010
Cusp Web, corroded
RIGHT CUSP AT STATION 560 TO 565 OUT OF LIMITS. INSTALLED DOUBLER RIGHT CUSP STATION 555 TO 568 AS PER AARD 53-20-00-16.
- 5 Aug 2010
Shear Tie, corroded
CORROSION ON SHEAR TIE AT STATION 1287 LONGERON 29 RIGHT TO LONGERON 30. FABRICATED SERVICEABLE SHEAR TIE AND REPAIR SPLICES PER SRM 53-03-00. TREATED, PRIMED…
- 3 Aug 2010
Bushing, worn
BUSHING WORN ON KNUCKLE RIB ON SLAT 1041. REPLACED WORN BUSHING PER ESO 80117 ON SLAT 1041.
- 3 Aug 2010
Service Panel, corroded
FUSELAGE AFT LAV SVC PANEL HAS CORROSION BETWEEN THE SKIN AND THE PAN AT THE LOWER AFT CORNER. INSTALLED NEW AFT LAVATORY SERVICE PANEL PAN PER AARD…
- 2 Aug 2010
Pan, cracked
LEFT UPPER AFT WINDOW PAN TAB CRACKED AT STATION 1041. INSTALLED DOUBLER PER AARD 53-10-00-25.
- 2 Aug 2010
Pan, cracked
LEFT UPPER AFT WINDOW PAN TAB CRACKED AT STATION 1079. INSTALLED DOUBLER PER AARD 53-10-00-25.
- 11 Oct 2009
Light, inoperative
LEFT NR 1 DOOR PORTABLE EXIT LIGHT INOPERATIVE. REPLACED PORTABLE LIGHT ASSEMBLY.
- 3 Mar 2009
Battery Pack, inoperative
EMERGENCY BATTERY PACK INOPERATIVE AT STATION 211 CENTER. REPLACED BATTERY PACK, OPERATIONAL CHECK GOOD.
- 3 Mar 2009
Battery Pack, discharged
AFT FLIGHT ATTENDANT SEAT AT AFT SERVICE DOOR, EMERGENCY LIGHT BATTERY WEAK. REPLACED BATTERY PACK FOR AFT SERVICE DOOR EMERGENCY LIGHT.
- 2 Mar 2009
Frame, cracked
CANT FRAME AT STATION 1510 CRACKED ABOVE MAINTENANCE LIGHT. INSTALLED DOUBLER PER EA MD80-53-00-5606.
- 2 Mar 2009
Bulkhead, cracked
CRACK IN BULKHEAD SKIN AT RIGHT BOTTOM ALIGNMENT PIN FOR RADOME, STATION 37. INSTALLED DOUBLER PER AARD 53-10-00-19.
- 2 Mar 2009
Longeron, cracked
LONGERON 2R IS CRACKED AFT OF STATION 1418. INSTALLED REPAIR PER AARD 53-30-00-2.
- 2 Mar 2009
Frame, cracked
THE 1418 FRAME CRACKED AT LONGERON 2R. DOUBLER INSTALLED PER SRM 53-01 FIGURE 2 AND EA MD80-53-005611.
- 28 Feb 2009
Frame, cracked
CANTED FRAME CRACKED BELOW MAINTENANCE LIGHT SWITCH AT STATION 1510. INSTALLED DOUBLER PER EA MD80-53-00-5606.
- 29 Apr 2008
Wire, broken
DFW - EMERGENCY LIGHT AT LEFT STAIRWELL HAS BROKEN WIRE. REPLACED QUICK DISCONNECT TERMINAL FOR EMERGENCY LIGHT AT LEFT STAIRWELL. SYSTEM GROUND CHECKED…
- 27 Apr 2008
Lens, broken
DFW - EMERGENCY LIGHT AT FORWARD TAIL COMPARTMENT WALL LENS BROKEN. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT FORWARD TAIL COMPARTMENT WALL. SYSTEM…
- 20 Apr 2007
Engine, oil consumption
DFW INFLIGHT T569/20APR IN DESCENT WITH THROTTLES AT IDLE LEFT OIL PRESSURE LOW LIGHT ILLUMINATED ALONG WITH OIL PRESSURE OF ZERO. SHUT DOWN LEFT ENGINE.…
- 8 Dec 2006
Battery Pack, inoperative
DFW - EMERGENCY LIGHT AT FORWARD OVERWING EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT FORWARD OVERWING EXIT SIGN. SYSTEM GROUND…
- 28 Apr 2006
Battery Pack, inoperative
LGA - FORWARD EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 14 Feb 2004
Battery Pack, inoperative
DEN - AFT UPPER EMERGENCY LIGHTS BETWEEN LAVATORIES INOPERATIVE. REPLACED BATTERY PACK AT B5-27 FOR AFT UPPER EMERGENCY LIGHTS BETWEEN LAVATORIES. SYSTEM…
- 26 Jan 2004
Battery Pack, inoperative
DEN) OVERHEAD EMERGENCY LIGHTS AT SEAT 20 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY LIGHTS AT SEAT 20. SYSTEM GROUND CHECKED NORMAL…
- 20 Sep 2003
Battery Pack, inoperative
DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTING WAS INOPERATIVE AT THE OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 19 Sep 2003
Apu, damaged
AIRCRAFT EN ROUTE ORD TO YYC, CREW OBSERVED SMOKE IN THE CABIN THAT WOULD NOT DISSIPATE. AIRCRAFT RETURNED TO ORD. REPLACED APU PERFORMED PACK BURN OUT AND…
- 15 Sep 2003
Battery Pack, inoperative
DEN - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE PATH LIGHTING WAS OBSERVED TO BE INOPERATIVE ABOVE FORWARD OVERWING EXITS. REPLACED BATTERY PACK. SYSTEM…
- 22 Aug 2003
Battery Pack, discharged
FORWARD ENTRY EMERGENCY LIGHT INOPERATIVE AT LOCATIONS B5-23. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 18 Jul 2002
Floor Support, corroded
TUL - FOUND LONGITUDINAL FLOOR SUPPORT AT RBL 52 HAS AREA OF CORROSION AT STATION 172 AND 195. INSTALLED NEW LONGITUDINAL FLOORBOARD SUPPORT AT RBL 52 STATION…
- 18 Jul 2002
Floor Support, corroded
TUL - FOUND HORIZONTAL FLOORBOARD SUPPORT AT STATION 200 HAS AREA OF CORROSION AT RBL 49. INSTALLED NEW FLOOR SUPPORT AT STATION 200 RBL 49 SRM 51-01. (M)
- 11 Jul 2002
Seat Track, gouged
TUL - FOUND GOUGE IN NR 2 SEAT TRACK APPROX STATION 1250. INSTALLED NEW SECTION OF SEAT TRACK FROM STATION 1240-1309 PER SRM 51-01. (M)
- 11 Jul 2002
Web, corroded
TUL - FOUND LEFT CUSP CORRODED STATION 1306. INSTALLED NEW CUSP SECTION FROM LEFT 1250 TO 1306 AS PER SRM 53-05 FIG 97. (M)
- 10 Jul 2002
Web, corroded
TUL - FOUND CORROSION ON LEFT CUSP, UNDER NR 1 SEAT TRACK STATION 1175. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 53-00-00-02. (M)
- 10 Jul 2002
Door Frame, corroded
TUL - FOUND CORROSION ON AFT CARGO DOOR CUT OUT LOWER DOOR BEAM. REMOVED AND REPLACED AFT CARGO CUT OUT LOWER DOOR BEAM PER AARD 53-10-00-3. (M)
- 8 Jul 2002
Web, corroded
TUL - FOUND FLOOR WEB HAS CORROSION STATION 190-200, RBL 49-52. CUT OUT CORROSION INSTALLED DOUBLER PER SRM 51-01 FIG 2 SHEET 1. (M)
- 8 Jul 2002
Web, corroded
TUL - FOUND FLOOR WEB HAS CORROSION STATION 178-180 RBL 50 TO 52. CUT OUT CORROSION INSTALLED DOUBLER PER SRM 51-01 FIG 2 SHEET 1. (M)
- 8 Jul 2002
Web, punctured
TUL - FOUND LEFT CUSP HAS FOUR PUNCTURE HOLES AT NR 1 SEAT TRACK, STATION 1200 TO 1214. INSTALLED DOUBLER AS PER AARD 53-00-00-02 SRM 53-01. (M)
- 2 Jul 2002
Web, corroded
TUL - FOUND THREE SMALL AREAS SURFACE CORROSION LEFT CUSP STATION 526. CUT OUT CORROSION, FABRICATE DOUBLER ALODINED, AND PRIMED. REPAIR AREA AND DOUBLER,…
- 8 Feb 2001
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY EXIT LIGHT AT TAIL CONE INOPERATIVE. RE-SPLICED OVERHEAD EMERGENCY EXIT LIGHT WIRE AT TAIL CONE. SYSTEM…
- 30 Oct 2000
Light, inoperative
DFW DURING OVERNIGHT MAINTENANCE OVERHEAD EMERGENCY EXIT LIGHT AT FORWARD ENTRY INOPERATIVE. REPLACED OVERHEAD EMERGENCY EXIT LIGHT ASSEMBLY AT FORWARD ENTRY.…
- 30 Oct 2000
Light, inoperative
DFW DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT AT AFT STAIR SLIDE WALL INOPERATIVE. REPLACED EMERGENCY LIGHT SPLICE AT AFT STAIR SLIDE WALL. SYSTEM…
- 9 Apr 1999
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, AFT TAIL CONE EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AFT TAIL CONE EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND…
- 16 Aug 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, TAIL CONE RELEASE HANDLE EMERGENCY FLOOR LIGHT INOPERATIVE. REPLACED ENVIRONMENTAL SPLICE ON TAIL CONE RELEASE HANDLE…
- 16 Aug 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, AFT STAIRS EMERGENCY EXIT FLOOD LIGHT INOPERATIVE. REPAIRED WIRE ON AFT STAIRS EMERGENCY EXIT FLOOR LIGHT. SYSTEM GROUND…
- 16 Aug 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING FROM WING EXITS AFT INOPERATIVE. REPAIRED WIRE IN EMERGENCY EXIT FLOOR PATH LIGHTING.…
- 13 Aug 1998
Flashlight, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLIGHT ATTENDANT FLASHLIGHT AT FORWARD ENTRY INOPERATIVE. REPLACED EMERGENCY FLIGHT ATTENDANT FLASHLIGHT AT…
- 20 Jun 1998
Filter, clogged
DFW - FLT 2083 - EN ROUTE DFW/IAH IN CRUISE, RIGHT ENGINE OIL STRAINER CLOGGIN G LIGHT ILLUMINATED. OIL TEMPERATURE WAS 128 DEGREES AND OIL PRESSURE 45 PSI.…
- 31 Aug 1997
Coalescer, contaminated
DFW - FLT 0425 - AFTER TAKEOFF DFW DURING CLIMB-OUT, ACRID ODOR NOTED IN CABIN. AIRCRAFT RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED LT AND RT…
- 14 Feb 1997
Connector, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN FIRST CLASS CABIN INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTORS AT FORWARD PART…
- 5 Feb 1997
Connector, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT IN FORWARD SECTION OF MAIN CABIN INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR BY PAX SEAT…