N753MA
2024 Compagnie Daher TBM 700 standard FAA →
registration
- 2024
aircraft radio
earlier registrations
1 past record
- 1997
service difficulty reports
37 reports
- 11 Mar 2017
Battery Pack, inoperative
DURING PRE FLIGHT CHECK, RIGHT SIDE AFT EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. TROUBLESHOOTING REVEALED A FAULTY BATTERY PACK, WHICH WAS REMOVED AND…
- 7 Mar 2017
Megaphone, inoperative
DURING THE PRE-FLIGHT TRANSIT CHECK, THE MEGAPHONE FAILED THE OPERATIONAL CHECK. THE UNIT WAS REMOVED AND REPLACED.
- 26 Feb 2016
Stiffener, corroded
CORROSION ON STIFFENER IN LAVATORY, & GALLEY AREA. WET AREA.
- 26 Feb 2016
Intercostal, cracked
INTERCOSTAL CRACKED, BS 312-328 LBL 45, SECTION 41. REPLACED, MADE ISE SAMPLE 1. DOUBLER INSTALLED, NDT STOP DRILLED CRACK. NR 0077, W/O 17007.
- 26 Feb 2016
Angle, corroded
FWD LOWER CARGO COMPARTMENT, BS 520, STR 28.ANGLE REPLACED FABRICATED IAW SAMPLE. WET AREA- CAUSE.
- 12 Dec 2015
Light, inoperative
EMERGENCY LIGHT AT SEAT 9DF INOPERATIVE.
- 21 Nov 2015
Battery Pack, failed
LT AFT DOOR EMERGENCY LIGHT BATTERY PACK DEFECTIVE.
- 19 Aug 2015
Light, inoperative
R1 DOOR EMERGENCY LIGHT INOPERATIVE.
- 28 Jul 2015
Battery Pack, failed
EMERGENCY EXIT LIGHT AT REAR OVERWING WINDOW INOPERATIVE.
- 23 Jul 2012
Indication Sys, malfunctioned
LEFT PNUEMATIC PRESSURE INDICATOR DROPPED TO ZERO. NO CHANGE IN AIRCRAFT PRESSURIZATION FOR THE REMAINDER OF FLIGHT.
- 21 Jul 2012
Warning Light, illuminated
ON PUSHBACK LEFT BODY WING OVERHEAT LIGHT ILLUMINATED ISOLATED PER QRH. LIGHT WENT OUT BUT CAME BACK ON WHEN APU BLEED OPENED FOR NR 1 ENG START.
- 20 Jul 2012
Indicator, failed
NUMBER TWO OIL QTY INDICATIONS FAILED IN FLIGHT. PRESSURE AND TEMP REMAINED WITHIN LIMITS.
- 10 Mar 2012
Battery Pack, discharged
ON P/T FOUND RT AFT SERVICE DOOR EMERGENCY EXIT LIGHT 3E INOP. T/S FOUND BAD BATTERY PACK, REMOVED & REPLACED POWER SUPPLY ASSY FOR RT AFT SERVICE DOOR POS AS…
- 9 Jul 2011
Circuit Breaker, tripped
ETOPS SIGNIFICANT SYSTEM: GEN PWR CONT CB POPPED AND APU SHUTDOWN AT GATE. FOUND GEN PWR CONT C/B INADVERTENTLY POPPED RESET C/B AND ACCOMPLISHED OPERATIONAL…
- 30 Mar 2011
Indicator, fluctuates
ETOPS SIGNIFICANT SYSTEM: ENGINE NR 2 VIBRATION INDICATOR FLUCTUATES OCCASIONALLY FROM 0 TO 4.5 AND BACK. REPLACED VIB COMPUTER IAW AMM 77-31-03 ENG RUN UP…
- 12 Mar 2011
Starter, malfunctioned
ETOPS SIGNIFICANT SYSTEM: NR 2 ENGINE STARTER IS NOT AUTOMATICALLY CUTTING OUT AT 46 PERCENT OCCASIONALLY. REMOVED AND REPLACED NR 2 ENG START SWITCH IAW AMM…
- 21 Jan 2011
Connector, dirty
ETOPS SIGNIFICANT SYSTEM: ON DESCENT NR 2 ENGINE VIBRATION MONITOR FLUCTUATES BETWEEN .5 AND MAX OF 5. PERFORMED BITE CHECK OF AVMS, CHECKED SENSORS, WIRING,…
- 11 Jan 2011
Control Valve, inoperative
ETOPS SIGNIFICANT SYSTEM: RIGHT PACK LIGHT ILLUMINATED ON RECALL. REPLACED RIGHT PACK TEMP CONTROL VALVE.
- 4 Jan 2011
Valve, out of adjust
ETOPS SIGNIFICANT SYSTEM: APU EGT GAUGE INTERMITTENT. FOUND THE CIRCUIT RESISTANCE VALVE TOO HIGH. ADJUSTED VALVE. SYSTEM OPERATION NORMAL.
- 2 Dec 2010
Indicator, faulty
ETOPS SIGNIFICANT SYS: ON APPROACH CREW HAD A FLAP ASSEMETRY BETWEEN 2 AND 5. ACCOMPLISHED NON-NORMAL CHECKLIST. AFTER LANDING, REPLACED FLAP POSITION…
- 16 Nov 2010
Gauge, erratic
ETOPS SIGNIFICANT SYSTEM: DURING FLIGHT NR 2 ENGINE VIBRATION BECAME ERRATIC AND UNRELIABLE.
- 31 Aug 2010
Battery Pack, discharged
DURING PT INSP FOUND SEVERAL LIGHTS INOPERATIVE ON EMERGENCY LIGHTING SYSTEM.
- 29 Aug 2010
Knob, broken
ETOPS SIGNIFICANT SYSTEM: NR 2 HF RADIO INNER KNOB BROKEN.
- 24 Jun 2010
Warning Light, illuminated
ETOPS SIGNIFICANT SYSTEM - LT WINDOW OVERHEAT ILLUMINATED.
- 15 Apr 2010
Indication Sys, activated
ETOPS SIGNIFICANT ITEM - NR 2 ENGINE VIBRATION INDICATION. TRANSFERRED FROM DMI 7265.
- 14 Apr 2010
Indication Sys, activated
ETOPS SIGNIFICANT ITEM - NR 2 ENGINE VIBRATION INDICATION. NO AIRFRAME VIBRATION.
- 13 Apr 2010
Actuator, leaking
ETOPS SIGNIFICANT ITEM - UPPER AILERON POWER CONTROL UNIT IS LEAKING FROM ACTUATOR PISTON.
- 22 Feb 2010
Solenoid Valve, inoperative
ETOPS SIGNIFICANT SYSTEM - APU GENERATOR KICKED OFF LINE DURING ENGINE START.
- 17 Feb 2010
Generator, shutdown
ETOPS SIGNIFICANT SYSTEM - APU GENERATOR KICKED OFF LINE DURING ENGINE START.
- 16 Feb 2010
Fuel Control, malfunctioned
ETOPS SIGNIFICANT SYSTEM - APU DROPPED OFF LINE WHILE STARTING ENGINES.
- 14 Feb 2010
Apu, malfunctioned
ETOPS SIGNIFICANT SYSTEM - APU DROPPED OFF LINE WHEN STARTING ENGINES.
- 25 Jan 2010
Warning System, false activation
ETOPS SIGNIFICANT SYSTEM - L/E SLAT IN TRANSIT LIGHT REMAINS ON.
- 24 Dec 2009
Warning Light, illuminated
ETOPS SIGNIFICANT SYSTEM -TRANSCRIBED FROM DMI 6985 AUTO FAIL LIGHT GOES OFF WHEN PRESSURIZATION MODE SELECTOR IS IN ALTN.
- 12 Dec 2009
Warning Light, illuminated
ETOPS SIGNIFICANT SYSTEM - ALL THREE ZONE TEMP LIGHTS ILLUMINATED ON RECALL.
- 12 Dec 2009
Warning Light, illuminated
ETOPS SIGNIFICANT SYSTEM - REFERENCE DEFERRED DMI CTL 6943 ALL 3 ZONE TEMP LIGHT CAME ON DURING MASTER CAUTION RECALL.
- 8 Dec 2009
Warning Light, illuminated
ETOPS SIGNIFICANT SYSTEM - TRANSCRIBED FROM DMI 6931 "AUTO FAIL LIGHT ILLUMINATED AGAIN INFLIGHT PRESSURIZATION NORMAL, SELECTED ALTN MODE - PRESSURIZATION…
- 17 Nov 2009
Apu, out of tolerance
ETOPS SIGNIFICANT SYSTEM - APU SPEED DECREASES WHEN LOAD IS APPLIED.