N7537A
Boeing 720-023B FAA →
earlier registrations
2 past records
- 1990
service difficulty reports
91 reports
- 26 Nov 2013
Slide, unserviceable
LT NR 1 DOOR SLIDE FELL OUT OF DOOR & BOTH LACE PINS PULLED. REPLACED LT NR 1 DOOR SLIDE, OPERATIONS CHECKED NORMAL.
- 11 Jan 2013
Skin, damaged
DENT TO LEADING EDGE OF SLAT NUMBER 1, 33 INCHES FROM INBOARD END. REMOVED LOWER SKIN AND REWORKED DENTED AREA TO BE WITHIN LIMITS, DYE CHECKED REWORKED AREA…
- 28 Nov 2012
Duct, ruptured
DFW - CREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED DURING CLIMBOUT. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT.…
- 22 Jun 2012
Brake, dragging
DFW - CREW REPORTED UPON THROTTLES BEING SET FOR TAKEOFF, WHEEL NOT TURNING LIGHT ILLUMINATED. AIRCRAFT DID NOT ACCELERATE MORE THAN 10-15 KNOTS. FLIGHT…
- 15 Jul 2011
Battery Pack, not seated
CEILING EMERGENCY LIGHTS FROM ROW 18 TO 21 INOPERATIVE. RESEATED BATTERY PACK AT ROW 20. OPS CHECK NORMAL.
- 14 Jul 2011
Battery, not seated
CEILING EMERGENCY LIGHTS AT ROWS 18 TO 21 INOPERATIVE. RESEATED BATTERIES IN BATTERY PACK AT ROW 20. OPS CHECK NORMAL.
- 28 Apr 2011
Hinge, worn
JFK - INGLIGHT LGA-DFW. CREW REPORTED BANGING NOISE HEARD COMING FROM NOSE OF AIRCRAFT. EMERGENCY DECLARED FLIGHT DIVERTED JFK LANDED WITHOUT INCIDENT. NOISE…
- 27 Mar 2011
Piston, missing
DFW - CREW REPORTED NOSE GEAR DOORS WOULD NOT CLOSE UPON RETRACTION. SECOND ATTEMPT HAD NOSE LANDING GEAR FAILED TO RETRACT. FLIGHT RETURNED DFW LANDED…
- 4 Feb 2011
Fan Blade, damaged
IAH - CREW REPORTED LEFT ENGINE COMPRESSOR STALL ON CLIMBOUT. AUTOPILOT KICKED OFF AND AIRCRAFT YAWED SLIGHTLY. EMERGENCY DECLARED FLIGHT RETURNED IAH LANDED…
- 8 Aug 2010
Power Supply, failed
TUS - CREW REPORTED POWER PORT SYSTEM ON SEAT 12B SPARKED. CIRCUIT BREAKER PULLED TO STOP SPARKS. EMERGENCY DECLARED, LANDED TUS WITHOUT INCIDENT. REPLACED…
- 14 Mar 2010
Angle, corroded
PLOW ANGLE HAS CORROSION AT STATION 1338 LONGERON 29 LEFT TO LONGERON 29 RIGHT. REPLACED CORRODED PLOW ANGLE WITH NEW ANGLE IAW DWG 9915561, SRM 51-30-2 AND…
- 13 Mar 2010
Doubler, corroded
CARGO AFT CX CORROSION FORWARD SIDE OF AFT PRESSURE BULKHEAD PLOW ANGLE DOUBLER. DOUBLER WAS OUT OF LIMITS PER SRM 53-01. NEW AFT PRESSURE BULKHEAD DOUBLER…
- 13 Mar 2010
Angle, corroded
PLOW ANGLE CORROSION REMOVAL BEYOND LIMITS. REMOVED AND REPLACED PLOW ANGLE PER SRM 51-30-02.
- 12 Mar 2010
Cargo Track, corroded
CORROSION ON LEFT TIE DOWN TRACK STA 1220 SPLICE TOP AND BOTTOM IN AFT CARGO. INSTALLED NEW SPLICE PER SRM 51-30.
- 12 Mar 2010
Cargo Track, corroded
AFT CARGO HAS CORROSION LEFT TIE DOWN TRACK ATTACH POINTS AND UPPER EDGE TABS STATION 1220 TO 1322. INSTALLED NEW TRACK PER SRM 51-30.
- 11 Mar 2010
Frame, corroded
AFT CARGO FRAME 1271 AFT SIDE LONGERON 27 LEFT TO LONGERON 26 RIGHT HAS CORROSION. BLENDED OUT CORROSION UNDER SRM 51-10-03. OUT OF LIMITS. INSTALLED REPAIR…
- 11 Mar 2010
Skin, dented
DENT IN FUSELAGE STATION 206 BETWEEN LONGERON 4 LEFT AND 5 LEFT. COLD WORKED DENT REF: SRM 53-04 FIG 38 DYE CHECKED NO CRACKS FOUND. INSTALLED DOUBLER PER SRM…
- 11 Mar 2010
Frame, corroded
CORROSION ON FRAME 1231 AFT SIDE LONGERON 30. FRAME 1231 FOUND TO BE OUT OF LIMITS ABOVE LONGERON 30. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER AND FILLER…
- 10 Mar 2010
Fitting, cracked
FITTING IN LOWER FORWARD CORNER OF DOOR CUTOUT IS CRACKED STATION 1155 AT AFT CARGO. INSTALLED NEW CORNER SUPPORT PER SRM 51-30-05.
- 10 Mar 2010
Membrane, corroded
CORROSION TOP SIDE OF SUBFLOOR STATION 200 TO 216 OUTBOARD SIDE OF SEAT TRACK NUMBER 5. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD53-20-00-16.
- 10 Mar 2010
Cusp Web, corroded
RIGHT CUSP CORRODED AT STATION 1183 TO 1186. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.
- 10 Mar 2010
Cusp Web, cracked
RIGHT CUSP CRACKED STATION 1173. INSTALLED DOUBLER AT STATION 1173 PER EA MD80-53-009531.
- 10 Mar 2010
Frame, cracked
STATION 1418 FRAME CRACKED AT LONGERON 2 RIGHT. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 53-03-00 FIGURE 31A.
- 9 Mar 2010
Skin, dented
FUSELAGE DENT AT STATION 300 BETWEEN LONGERON 22 RIGHT AND 23 RIGHT. INSTALLED DOUBLER PER SRM 53-04-00 FIGURE 12B.
- 9 Mar 2010
Membrane, corroded
CORROSION ON SUBFLOOR UNDER GALLEY TIE DOWN AT STATION 218 RIGHT BUTTLINE 11. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.
- 9 Mar 2010
Tie Down, corroded
CORROSION TOP OF GALLEY TIE DOWN. INSTALLED NEW GALLEY TIE DOWN FITTING PER SRM 51-30-05.
- 9 Mar 2010
Beam, corroded
CORROSION ON LOWER DOOR CUTOUT BEAM STATION 1155 TO 1212 ON LOWER LEG FOR AFT CARGO. INSTALLED DOOR BEAM DOUBLER PER AARD 53-10-00-3 AND SRM 51-30.
- 9 Mar 2010
Cusp Web, corroded
CUSP HAS CORROSION BETWEEN NUMBER 10 SEAT TRACKS STATION 1287. REPLACED LEFT CUSP SHEET STATION 1250 TO 1309 PER AARD 53-20-00-16.
- 9 Mar 2010
Fitting, corroded
CORROSION ON LOWER AFT FITTING AFT CARGO DOOR CUTOUT STATION 1212. REPLACED SUPPORT FITTING PER AARD 51-00-00-12.
- 9 Mar 2010
Seat Track, corroded
CORROSION AT NUT CLIP HOLE ON OUTBOARD FLANGE OF SEAT TRACK NUMBER 5 STATION 204 OUT OF LIMITS. CUT OUT CORROSION AND INSTALLED STRAP PER AARD 53-20-00-13.
- 8 Mar 2010
Beam, cracked
FORWARD ENTRY DOOR AFT END NUMBER 2 BEAM CRACKED. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 52-05 -00 FIGURE 31 SHEET 13.
- 8 Mar 2010
Beam, cracked
FORWARD ENTRY FORWARD END OF NUMBER 2 BEAM CRACKED. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 52-05-00 SHEET 13.
- 8 Mar 2010
Seat Track, damaged
NUMBER 2 SEAT TRACK HAS CORROSION STATION 1305. NUMBER 2 SEAT TRACK WAS REPAIRED PER SRM 53-05-00 FIGURE 4F.
- 8 Mar 2010
Fitting, corroded
GALLEY FITTING UNDER SUBFLOOR G-2 GALLEY INBOARD AFT MOUNT CORRODED. INSTALLED NEW FITTING PER SRM 51-30-05.
- 7 Mar 2010
Longeron, cracked
LONGERON 3 LEFT CRACKED OUTBOARD SIDE AT RADIUS STATION 160. ACCOMPLISHED SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.
- 6 Mar 2010
Membrane, cracked
SUBFLOOR CRACKED STATION 155. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 6 Mar 2010
Doubler, corroded
AFT CARGO CORROSION FORWARD SIDE OF AFT PRESSURE BULKHEAD PLOW ANGLE DOUBLER STATION 1338 LONGERON 30. REPLACED DOUBLER PER SRM 51-01-00 AND SRM 51-30-00.
- 5 Mar 2010
Cusp Web, cracked
A 2 INCH CRACK IN LEFT CUSP AT STATION 227 OUTBOARD OF NUMBER 1 SEAT TRACK. REMOVED DAMAGE INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.
- 5 Mar 2010
Cusp Web, cracked
EMERGENCY EQUIPMENT COMPARTMENT RIGHT SIDE SUB FLOOR CRACKED BELOW GALLEY 1 WATER DRAIN PAN STATION 155. INSTALLED DOUBLER PER AARD 53-20-00-16
- 5 Mar 2010
Doubler, cracked
STATION 1022 LEFT WINDOW PAN DOUBLER IS CRACKED AT UPPER AFT CORNER. REPAIRED PER AARD 53-10-00-25.
- 4 Mar 2010
Vane, worn
RIGHT WING WORN AREAS OUTBOARD FLAP INBOARD VANE INBOARD LEADING EDGE. DID HOT BOND REPAIR PER SRM 51-70-02.
- 4 Mar 2010
Fitting, worn
LEFT NUMBER 4 SLAT OUTBOARD KNUCKLE FITTING WORN. REPLACED WORN KNUCKLE FITTING LEFT NUMBER 4 SLAT PER 27-80-00 REPAIR 2 ESO 80117.
- 3 Mar 2010
Rib, cracked
LEFT WING SLAT TRACK ATTACH RIB ON NUMBER 5 SLAT IS CRACKED AT NUMBER 14 SLAT TRACK. REPLACED 2ND FROM OUTBOARD ATTACH FITTING PER ESO 80117.
- 3 Mar 2010
Cusp Web, cracked
CUSP CRACKED AT STATION 218 JUST OUTBOARD OF SEAT TRACK 2. REMOVED DAMAGE, INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.
- 12 Nov 2009
Anti-Skid Sys, contaminated
WHEN LANDING GEAR WAS LOWERED ALL 4 ANTISKID LIGHTS ILLUMINATED WHEN ANTISKID SYSTEM WAS CYCLED. ALL LIGHTS WENT OUT EXCEPT RIGHT INBOARD. ANTISKID CYCLED…
- 12 Jul 2009
Battery Pack, inoperative
FIRST CLASS EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT. / OPS CHECK GOOD.
- 13 Mar 2009
Tube, ruptured
MCO - CREW REPORTED NUMBER 2 ENGINE BLEED LIGHT AND FULL FIRE WARNING INDICATION CAME ON. EMERGENCY DECLARED, RETURNED MCO WITHOUT INCIDENT. AIRCRAFT REMOVED…
- 17 Nov 2008
Frame, cracked
CANT FRAME CRACKED AT LOWER TAILCONE ALIGNMENT PIN, STATION 1510, LEFT. REPAIRED PER ESO80559 DATED 11-17-08.
- 15 Nov 2008
Frame, cracked
FRAME AT STATION 1418 CRACKED AT LONGERON 2L. REPAIRED PER ESO80559 DATED 11-14-08.
- 15 Nov 2008
Skin, cracked
2 CRACKS IN SKIN AT STATION 1380 RT BETWEEN LONGERON 13R AND 14R. INSTALLED DOUBLER PER SRM 53-01-00.
- 4 Apr 2008
Battery Pack, inoperative
LGA - EMERGENCY LIGHTS IN AFT CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 30 Nov 2005
Battery Pack, inoperative
LGA - FORWARD SECTION SEAT MOUNTED EMERGENCY EGRESS LIGHT INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD SECTION SEAT MOUNTED EMERGENCY EGRESS LIGHT. SYSTEM…
- 30 Nov 2005
Battery Pack, inoperative
LGA - COCKPIT OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK FOR COCKPIT OVERHEAD EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 11 Nov 2005
Battery Pack, inoperative
LGA - EMERGENCY LIGHTS AT RIGHT OVERWING AFT EXIT INOPERATIVE. REPLACED BATTERY PACK B2505 FOR EMERGENCY LIGHTS AT RIGHT OVERWING AFT EXIT. SYSTEM GROUND…
- 3 Jun 2005
Battery Pack, discharged
DFW - EMERGENCY LIGHTS IN CEILING ABOVE SEATS 18-21 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN CEILING ABOVE SEATS 18-21. SYSTEM GROUND…
- 21 Nov 2004
Battery Pack, inoperative
ORD - CEILING MOUNTED EMERGENCY LIGHTS IN FIRST CLASS INOPERATIVE. REPLACED BATTERY PACK FOR CEILING MOUNTED EMERGENCY LIGHTS IN FIRST CLASS. SYSTEM GROUND…
- 21 Nov 2004
Battery Pack, inoperative
ORD - CEILING MOUNTED EMERGENCY LIGHTS BETWEEN SEAT ROWS 13 AND 16 INOPERATIVE. REPLACED BATTERY PACK FOR CEILING MOUNTED EMERGENCY LIGHTS BETWEEN SEAT ROWS…
- 4 Dec 2003
Pump, defective
MSP T1510/04 EN ROUTE MSP-DFW AFT CENTER FUEL TANK BOOST PUMP POPPING CIRCUIT BREAKER. RETURNED MSP AND LANDED WITHOUT INCIDENT. PLACARDED AFT CENTER FUEL…
- 9 Nov 2003
Battery, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, FOUND AFT TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY FOR AFT TAIL COMPARTMENT EMERGENCY LIGHTS.…
- 8 Apr 2003
Battery, inoperative
ORD - DURING OVERNIGHT MAINTENANCE, AFT SEAT MOUNTED EMERGENCY EXIT PATH LIGHTS AT ROW 20 INOPERATIVE. REPLACED AFT EMERGENCY EXIT PATH LIGHT BATTERY. SYSTEM…
- 15 Mar 2003
Battery, inoperative
DURING OVERNIGHT MAINTENANCE, AFT ZONE SEAT MOUNTED EMERGENCY EXIT LIGHTING INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY EXIT PATH LIGHTING BATTERY. SYSTEM…
- 15 Nov 2002
Connector, loose
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD AIRSTAIR EMERGENCY EXIT LIGHT INOPERATIVE. SECURED EMERGENCY EXIT LIGHT QUICK DISCONNECT AT FORWARD AIRSTAIR.…
- 31 May 2002
Frame, corroded
TUL - FOUND CORROSION UNDER FASTENERS ON INSIDE FRAME AT STATION 1463. INSTALLED DOUBLER PER ESO DATED 5-30-02, SPOT FACED CORROSION AREAS. STRAP INSTALLED, 2…
- 31 May 2002
Web, corroded
TUL - FOUND WEB CORRODED SEVERAL AREAS FS 1213-1215 ABOVE L28R WEB BLOWN OUT. INSTALLED NEW WEB PER SRM 51-01. (M)
- 31 May 2002
Door Frame, corroded
TUL - FOUND CARGO CUT OUT LOWER FRAME HAS CORROSION ON OUTBOARD FACE STATION 1155-1211, SEVERAL AREAS. INSTALLED NEW FRAME PER SRM 51-01. (M)
- 29 May 2002
Intercostal, cracked
TUL - FOUND TOP FLANGE OF INTERCOSTAL CRACKED AT TWO FASTENER HOLES BELOW CABIN FLOOR, BL0. REMOVED CRACKED INTERCOSTAL AND INSTALLED NEW PER SRM 51-01. (M)
- 24 May 2002
Skin, dented
TUL - FOUND TWO DEEP DENTS IN SKIN STATION 452 BETWEEN LONGERON 22 AND 23L. INSTALLED PERMANENT EXTERNAL REPAIR PER SRM 53-04 FIG 12B SHEET 4, 5, 6 95 AND 96.…
- 22 May 2002
Threshold, corroded
TUL - FOUND CORROSION ON FORWARD CARGO DOOR FRAME, LOWER THRESHOLD AT STATION 405. REMOVED AND REPLACED SECTION OF PAN (THRESHOLD) PER SRM 53-05 FIG 44. (M)
- 20 May 2002
Attach Angle, cracked
TUL - FOUND CRACK BETWEEN RIVETS ON VERTICAL STABILIZER TO FUSELAGE RIGHT ATTACH ANGLE 8 INCHE FORWARD OF VERTICAL REAR SPAR ATTACH POINT. CUT OUT DAMAGED…
- 20 May 2002
Skin, damaged
TUL - FOUND CREASE IN SKIN ALONG FRAME AND SEVERAL DENTS IN SKIN STATION 277 ABOVE LONGERON 18L. INSTALLED REPAIR DOUBLER PER SRM 53-04 FIG 38. (M)
- 17 May 2002
Floorbeam, cracked
TUL - FLOORBEAM CRACKED, STATION 927, LBL 56. REMOVED AND INSTALLED NEW FLOORBEAM PER SRM 51-01. (M)
- 17 May 2002
Skin, gouged
TUL - FOUND TWO DEEP GOUGES STATION 387-395 LONGERON 23L, STATION 369-374 STATION 370. INSTALLED PERMANENT REPAIR PER SRM 5304 FIG 12B SHEET 4, 5, 6 AND 95,…
- 16 May 2002
Seat Track, corroded
TUL - FOUND NR 1 SEAT TRACK CORRODED STATION 1236 AND 1208. REPAIRED DAMAGED AREAS PER AARD 53-20-00-10. (M)
- 16 May 2002
Shear Tie, cracked
TUL - FOUND SHEAR TIE CRACKED AFT SIDE OF 1437 FRAME BETWEEN L1 AND L2R. INSTALLED NEW SHEAR TIE SRM 51-01. (M)
- 16 May 2002
Skin, dented
TUL - FOUND DENT IN FUSELAGE SKIN RUNNING PARALLEL TO LONGERON 23L FROM STATION 387-395. INSTALLED PERMANENT REPAIR (CLAS 1) PER SRM 53-04 FIG 12B SHEET 4, 5,…
- 14 May 2002
Frame, damaged
TUL - ROUTED FRAME PREVIOUSLY WITHOUT REPAIR. INSTALLED STRAP REPAIR PER AARD 53-10-00-25. (M)
- 14 May 2002
Web, corroded
TUL - FOUND CORROSION ON BOTTOM SIDE OF LEFT CUSP STATION 617-622. REMOVED CORROSION AND INSTALLED DOUBLER AS PER SRM 53-01 PAGE 18. (M)
- 14 May 2002
Web, corroded
TUL - FOUND CORROSION TOP CUSP STATION 549-533, LEFT SIDE. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 53-01 PAGE 18. (M)
- 13 May 2002
Seat Track, corroded
TUL - FOUND NR 2 SEAT TRACK CORRODED STATION 1193. INSTALLED PLUG REPAIR AS PER SRM 53-05 FIG 4A. (M)
- 10 May 2002
Seat Track, corroded
TUL - FOUND SEAT TRACK NR 6 CORRODED STATION 451-458. INSTALLED SLAT TRACK REPAIR PER SRM 53-05 FIG 4A SHEET 1 AND 2. (M)
- 1 May 2002
Longeron, gouged
TUL - FOUND STATION 1306 ABOVE LONGERON 19R SKIN GOUGED. CUT OUT GOUGED AREA AND INSTALLED INTERNAL DOUBLER AND PLUG PER SRM 53-04 FIG 38 SHT 24 AND INSTALLED…
- 22 Feb 2002
Oven, odor
DFW - FLT 353 - EN ROUTE LGA-ORD, AT 31,000 FEET NR 1 FLIGHT ATTENDANT REPORTED SMOKE AND FUMES COMING FROM CEILING NEAR FORWARD GALLEY. SHUTOFF GALLEY POWER,…
- 8 Oct 1999
Connector, damaged
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD GALLEY EMERGENCY EXIT FLOOR PATH LIGHTING SIGN INOPERATIVE. REPLACED CONNECTOR PIN ON FORWARD GALLEY EMERGENCY…
- 11 Jul 1999
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD ENTRY WALK-AROUND EMERGENCY LIGHT ASSEMBLY INOPERATIVE. REPLACED WALK-AROUND EMERGENCY LIGHT ASSEMBLY. SYSTEM…
- 22 Jun 1999
Connector, loose
DFW - DURING OVERNIGHT MAINTENANCE GALLEY DOOR EMERGENCY EXIT LIGHT SIGN INOPERATIVE. REINSTALLED PINS IN QUICK DISCONNECT CONNECTOR FOR GALLEY DOOR EMERGENCY…
- 8 Apr 1999
Light, defective
DFW - DURING MAINTENANCE CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED EMERGENCY FLOOR PATH LIGHT STRIP AT BULKHEAD. SYSTEM…
- 21 Aug 1998
Tie Down, corroded
TUL - CORROSION ON AFT ARGO TIE DOWN TRACK FROM STA 1025 TO STA 1155. CORROSION REMOVAL EXCEEDED MAXIMUM ALLOWABLE AT STA 1057. INSTALLED REPAIR STRAP PER…
- 21 Aug 1998
Skin, dented
TUL - DENT AND CREASE IN FUSELAGE SKIN, STA 237 BETWEEN LONGERON 18L AND LONGERON 19L. ALSO, INTERNAL DAMAGE TO FUSELAGE FRAME, BENT AND CRACKED, AT SAME…
- 20 Aug 1998
Tie Down, corroded
TUL - CORROSION ON RT TIE DOWN TRACK, OUTBOARD FLANGE, STA 1212. REMOVED CORROSION. CUT-OUT DAMAGED AREA. INSTALLED FILLER AND STRAP REPAIR PER ESO 80559,…
- 17 Aug 1998
Frame, corroded
TUL - AFT CARGO CORROSION ON FRAME AFT SIDE LOWER LIP FS 1287 FROM LG 29R, LG29L. INSTALLED DOUBLER PER 53-03. (M)
- 20 May 1997
Connector, broken
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN THE FIRST 10 ROWS OF COACH FOUND INOPERATIVE. REPLACED BROKED EMERGENCY FLOOR LIGHT STRIP CONNECTOR IN…