N751PA
Dji INSPIRE 1 FAA →
reservations
earlier registrations
1 past record
NTSB
- 14 Apr 1984
incident, MB
service difficulty reports
27 reports
- 25 Oct 2003
Spring, failed
L1, R1, AND L4 DOOR GIRT BAR LEAF SPRINGS FAILED INSPECTION IAW MM-7200-03-00917 AND PACE MO NR B757-52-21003. REPLACED LEAF SPRINGS IAW MM 25-66-14.
- 25 Oct 2003
Socket, disconnected
FWD THREE FLOOR PATH LIGHTS OUT IN FWD CABIN AND BULB INOP IN LOWER EMERGENCY EXIT LIGHT AT L3 DOOR. RECONNECTED SOCKETS AT 2ND AND 3RD FLOOR LIGHT AND…
- 25 Oct 2003
Fuse, blown
R1 EMERGENCY EXIT LIGHT (EXTERIOR) INOP AND FLOOR PATH LIGHTING INOP AT ROWS 7 THRU 13. REPLACED BLOWN FUSE IN M730 POWER SUPPLY FOR R1 EXTERIOR LIGHT AND…
- 25 Oct 2003
Panel, corroded
RIGHT WING FUELING PANEL HAS CORROSION AROUND QUANTITY GAGE MOUNT SCREWS AND AROUND BONDING JUMPER MOUNT BOLT. REPLACED FUELING PANEL PER MM 28-21-08.
- 24 Sep 2003
Control Unit, malfunctioned
AUTO THROTTLE DISCONNECTS WHEN CAPTURING ALTITUDE EPR & SPD SWITCHES WON'T ENGAGE. PLACED ON MEL 22-11-4. 09/26/2003: REPLACED NR 1 FLAP/SLAT ELECTRIC UNIT &…
- 3 Sep 2003
Wire, broken
RED EMERGENCY FLOOR LIGHT BY L1 DOOR INOP. REPAIRED BROKEN WIRE AND REPLACED LENSE. OPS CHECKS OK.
- 12 Aug 2003
Lamp, inoperative
RT 1 DOOR EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED R1 DOOR EXTERIOR LIGHT. OPS CHECKS OK.
- 18 Jul 2003
Indicator, inoperative
EMERGENCY LIGHT INDICATOR INOP AND LENS BROKEN AT SEAT ROW 20ABC. RELAMPED AND REPLACED BROKEN LENS CAP. CHECKS OK PER MM 25-60.
- 16 Jul 2003
Wire, broken
SEVERAL EMERGENCY PATH LIGHTS INOP AFT OF L2 DOOR. REPAIRED BROKEN WIRE AT ROW 15C. OPS CHECK OK PER MM 33-50.
- 3 Jul 2003
Flashlight, inoperative
EMERGENCY FLASHLIGHT AT L3 DOOR INOP. REPLACED FLASHLIGHT ASSEMBLY.
- 30 Jun 2003
Bulb, burned out
EXTERIOR EMERGENCY LIGHTS INOP AT L1 AND R1 DOORS. REPLACED BULB IN L1 EXTERIOR EMERGENCY LIGHT AND CLEANED CONTACTS FOR R1 EXTERIOR EMERGENCY LIGHT. OPS…
- 20 Jun 2003
Wire, broken
L1 FLOOR EMERGENCY LIGHT INOP (RED). FIRST IN LINE. SPLICED BROKEN WIRE. OPS CHECKS NORMAL.
- 17 Apr 2003
Light, inoperative
R-1 EXTERIOR EMERGENCY LIGHT INOP. RELAMPED, OPS CHECK OK.
- 12 Apr 2003
Wire, loose
EMERGENCY LIGHTS ROW 17ABC ON FLOOR BROKEN OFF BY PASSENGER. REINSTALLED AND REPAIRED LOOSE WIRING ON EMERGENCY LIGHTING ROW 17ABC PER MM 33-50-00.
- 20 Mar 2003
Wire, damaged
TRACK LIGHTING AT L3 DOOR, RED, INOP. REPAIRED WIRE AND RELAMPED. OPS CHK. NORMAL
- 23 Feb 2003
Battery Pack, discharged
FOUR EMERGENCY PATH LIGHTS INOP - MAIN CABIN ROW 1-3. REPLACED BATTERY PACK. OPS CHK GOOD PER MM 25-60-00.
- 19 Jan 2003
Bulb
Bulb inop in R1 emergency light. Found bulb loose in socket. Re-installed. Ops chk. good.
- 19 Jan 2003
Bulb, inoperative
BULB INOPERATIVE IN L3 EMERGENCY LIGHT. REMOVED AND REPLACED BULB. OPS CHECKED GOOD.
- 9 Jan 2003
Light, inoperative
BULB INOP IN L1 EMERGENCY LIGHT. REMOVED AND REPLACED LIGHT BULB. OPS CHK. GOOD.
- 7 Dec 2002
Control Head, malfunctioned
FD DID NOT CAPTURE LOC, LOC ARMED SHOWN ON FMA BUT NO CAPTURE. REPLACED ILS CONTROL HEAD IAW MM 34-31-01. OPS CHECK & INDICATIONS NORMAL.
- 1 Nov 2002
Wire
F/A report - several emergency path lights inop - mid cabin. Insp lights found broken wire - repaired & ops check good per MM 33-51-00
- 17 Oct 2002
Slide
R3 door slide bottle pressure is low. R&R R3 door slide IAW 757MM 25-66-03.
- 16 Oct 2002
Light
Floor path emergency lights inop at mid lavatory. Relamped emergency path lights. ops check ok.
- 16 Oct 2002
Lamp
R1 door exterior emergency exit light out. Replaced lamp for R1 door emergency exit light. Ops chk. normal.
- 24 Sep 2002
Engine, flamed out
ON DESCENT INTO POS, NR 2 ENGINE FLAMED OUT. WENT TO FLT AND GOT A RELIGHT. INSPECTED NR 2 ENGINE FOR INTAKE & EXHAUST FOD DAMAGE, CHECKED N3 ROTATION,…
- 12 Jul 2002
Battery, discharged
REF MEL 25-63-4 CONT 0704003 R3 DOOR EMER FLASHLIGHT INOP. REPLACED BATTERY, OPS CHK GOOD. REF MM 25-63-00. THIS CLEARS MEL 0704003.
- 4 Jul 2002
Flashlight, inoperative
R3 EMERGENCY FLASHLIGHT INOP. ITEM DEFERRED IAW MEL 25-63-4 CONT 0704003.