N7506
Reims Aviation Sa CESSNA FR172G FAA →
earlier registrations
3 past records
- 1989
service difficulty reports
58 reports
- 28 Jun 2010
Skin, cracked
FUSELAGE SKIN CRACKED AT 1474 CANT FRAME APPROXIMATELY LONGERON 22 LEFT. INSTALLED EXTERNAL DOUBLER ON SKIN AT 1474 CANT FRAME AND LONGERON 22 LEFT PER SRM…
- 29 Aug 2009
Battery Pack, discharged
SEAT MOUNTED EMERGENCY ESCAPE PATH INOPERATIVE FROM ROW 3 TO ROW 19. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM. OPS CHECK GOOD.
- 29 Aug 2009
Battery Pack, not seated
AFT OVERWING HATCHES TOP EXIT LIGHTS INOPERATIVE. RESEATED BATTERY PACK AT BIN 20DEF AFT. AFT OVERHEAD EXIT SIGN OPS CHECKS GOOD.
- 29 Aug 2009
Battery Pack, discharged
FORWARD GALLEY FLOOR EXIT LIGHTS INOPERATIVE. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM, OPS CHECK GOOD.
- 29 Aug 2009
Battery Pack, discharged
FORWARD HATCHES OVERWING LOWER FLOOR EXIT LIGHTS INOPERATIVE. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM, OPS CHECK GOOD.
- 29 Aug 2009
Battery Pack, discharged
FLOOR EXIT LIGHT ACROSS FORWARD LAVATORY INOPERATIVE. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM, OPS CHECK GOOD.
- 1 Aug 2009
Slide, malfunctioned
FORWARD GALLEY DOOR SLIDE, FLIGHT ATTENDANT FAILED TO DISARM SLIDE AND SKYCHEF FAILED TO CHECK TO SEE IF IT WAS DISARMED, SKYCHEF OPENED DOOR AND SLIDE CAME…
- 30 Apr 2009
Lens, broken
MSP - EMERGENCY LIGHT LENS AT SEAT 18DEF BROKEN. REPLACED LENS AT SEAT 18DEF.
- 29 Mar 2009
Battery, discharged
LGA - MID CABIN FLIGHT ATTENDANT EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED BATTERY FOR MID CABIN EMERGENCY FLASHLIGHT.
- 30 Jan 2009
Battery Pack, discharged
MSP - EMERGENCY FLOOD LIGHTS OVER CENTER AREA INOPERATIVE. REPLACED BATTERY PACK.
- 9 Dec 2008
Longeron, corroded
CORROSION ON LONGERON 22L STATION 1286 TO 1295. REPAIRED PER SRM 53-02-00 FIG 18.
- 9 Dec 2008
Longeron, cracked
STATION 1260 LONGERON 22L, SPLICE CRACKED AT AFT END. INSTALLED SERVICEABLE LONGERON SPLICE PER SRM 51-02-00.
- 8 Dec 2008
Angle, corroded
CORROSION ON RIGHT CUSP TEE ANGLE STATION 220. INSTALLED A SERVICEABLE TEE ANGLE FROM STATION 180 TO 228 PER SRM 53-05-00.
- 8 Dec 2008
Fitting, corroded
CORROSION ON LOWER FORWARD CORNER FITTING IN AFT CARGO DOOR CUTOUT STATION 1155. INSTALLED A SERVICEABLE FITTING PER SRM 51-30.
- 8 Dec 2008
Fitting, corroded
CORROSION LOWER AFT CORNER FITTING IN AFT CARGO DOOR CUTOUT STATION 1212. INSTALLED A SERVICEABLE FITTING PER SRM 51-30.
- 8 Dec 2008
Intercostal, cracked
CRACKS IN INTERCOSTAL AT FASTENER HOLE STATION 1287 TO 1309, AFT CARGO. INSTALLED A SERVICEABLE INTERCOSTAL.
- 8 Dec 2008
Cusp Web, cracked
RIGHT CUSP CRACKED AT STATION 220. INSTALLED A SERVICEABLE CUSP SHEET FROM STATION 218 TO 237.
- 8 Dec 2008
Structure, corroded
CORROSION ON RIGHT SUBFLOOR STATION 218. REPAIRED PER AARD 53-20-00-16.
- 8 Dec 2008
Pan, corroded
CORROSION ON LOWER VERTICAL AND HORIZONTAL PAN LEGS, FORWARD CARGO PAN STATION 370 TO 425. INSTALLED SERVICEABLE DOOR PAN AND SPLICES PER SRM 53-05-00 FIG 44.
- 8 Dec 2008
Doubler, corroded
CORROSION ON DOUBLER AT FORWARD SERVICE DOOR STATION 180 TO 200. REMOVED AND REPLACED DOUBLER PER AARD 53-20-00-16.
- 8 Dec 2008
Seat Track, corroded
CORROSION ON NUMBER 5 SEAT TRACK STATION 200 TO 205. SPLICED IN NEW SEAT TRACK FROM STATION 200 TO 242 PER SRM 53-05-00.
- 8 Dec 2008
Cusp Web, corroded
CORROSION ON CUSP STATION 135 TO 155. INSTALLED DOUBLER.
- 7 Dec 2008
Cusp Web, corroded
CORROSION ON LEFT CUSP BETWEEN STATION 1250 AND 1304. REPAIRED PER AARD 53-20-00-16.
- 7 Dec 2008
Cargo Track, corroded
CORROSION ON LEFT TIE DOWN TRACK STATION 1041 TO 1220, AFT CARGO. INSTALLED A SERVICEABLE TIE DOWN TRACK PER SRM 53-01.
- 7 Dec 2008
Floorbeam, cracked
FLOORBOARD SUPPORT CRACKED UNDER BOARD C-14 STATION 1060. INSTALLED A SERVICEABLE SUPPORT PER SRM 51-01.
- 7 Dec 2008
Beam, corroded
CORROSION ON MID CARGO DOOR BEAM STATION 636 TO 693. REPAIRED PER AARD 53-10-00-3.
- 6 Dec 2008
Cargo Track, corroded
CORROSION ON RIGHT TIE DOWN TRACK IN AFT CARGO STATION 1041 TO 1155. INSTALLED SERVICEABLE TIE DOWN TRACK.
- 6 Dec 2008
Cusp Web, cracked
RIGHT CUSP CRACKED STATION 800. INSTALLED A SERVICEABLE CUSP SHEET PER SRM 51-01.
- 5 Dec 2008
Longeron, cracked
LONGERON 2L CRACKED AT STATION 160. REPAIRED LONGERON 2L FROM 148 TO 168 PER SRM 53-02-00 FIG 18.
- 5 Dec 2008
Cusp Web, cracked
RIGHT CUSP CRACKED AT STATION 810. REPAIRED PER AARD 53-20-00-16.
- 5 Dec 2008
Beam, corroded
CORROSION ON VERTICAL LEG OF AFT CARGO DOOR BEAM AT STATION 1163. INSTALLED FULL BEAM DOUBLER PER SRM 51-10-3 AND AARD 53-10-00-3.
- 3 Dec 2008
Angle, cracked
VERTICAL ANGLE CRACKED BELOW LONGERON 1 STATION 1338. REPAIRED PER AARD 53-10-00-15.
- 3 Dec 2008
Support Bracket, cracked
VERTICAL FLOORBEAM SUPPORT BRACKET CRACKED STATION 927 UNDER NUMBER 5 SEAT TRACK. INSTALLED A SERVICEABLE SUPPORT BRACKET PER SRM 51-01.
- 3 Dec 2008
Seat Track, corroded
CORROSION ON NUMBER 1 SEAT TRACK STATION 1278. INSTALLED REPAIR PLUG PER SRM 53-05-4A.
- 3 Dec 2008
Mount, corroded
FORWARD GALLEY OUTBOARD MOUNT CORRODED STATION 160. INSTALLED SERVICEABLE MOUNT.
- 3 Dec 2008
Mount, corroded
FORWARD GALLEY INBOARD MOUNT CORRODED STATION 160. INSTALLED A SERVICABLE MOUNT.
- 3 Dec 2008
Floorbeam, cracked
VERTICAL FLOORBEAM SUPPORT CRACKED STATION 927 UNDER SEAT TRACK NUMBER 2. INSTALLED A SERVICABLE SUPPORT.
- 2 Dec 2008
Attach Angle, cracked
ATTACH ANGLE CRACKED BELOW RIGHT HAND TIE DOWN TRACK STATION 237 FORWARD CARGO. INSTALLED SERVICEABLE ANGLE.
- 31 Dec 2007
Battery Pack, inoperative
LGA - EMERGENCY LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 5 Jan 2007
Valve, inoperative
IAD INFLIGHT T1507/05JAN DEC TO DFW - DURING CLIMB, THE LEFT FUEL TEMPERATURE ROSE AT 120 DEGREES THE OIL TEMPERATURE ROSE TO 150 DEGREES AND WAS IN THE…
- 31 Dec 2004
Battery Pack, discharged
STL - RIGHT AND LEFT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR RIGHT AND LEFT OVERWING EMERGENCY EXIT LIGHTS. SYSTEM GROUND…
- 11 Jun 2004
Battery Pack, inoperative
DFW - EMERGENCY LIGHTS IN TAIL CONE ARE INOPERATIVE. REPLACED BATTERY AND CHARGER ASSEMBLY FOR EMERGENCY LIGHTS IN TAIL CONE. SYSTEM GROUND CHECKED NORMAL…
- 7 Nov 2002
Battery Pack, discharged
PHX - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTS AT SEATS 24-26 INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 20 Sep 2002
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS IN CEILING AT ROWS 3-7 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY PACK IN CEILING AT ROWS…
- 5 Dec 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, AFT ACCESSORY OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 26 Apr 2001
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, CEILING MOUNTED EMERGENCY EXIT LIGHT AT ROW 13 THROUGH 17 DIM. REPLACED CEILING MOUNTED EMERGENCY EXIT LIGHT BATTERY PACK.…
- 25 Mar 2001
Lamp, malfunctioned
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 20D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 20D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 25 Mar 2001
Lamp, malfunctioned
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ILGHT AT SEAT 18D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 18D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 25 Mar 2001
Lamp, malfunctioned
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 13D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 13D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 25 Mar 2001
Lamp, malfunctioned
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 7D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 25 Mar 2001
Lamp, malfunctioned
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 17D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 17D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 30 Nov 1999
Lamp Holder, failed
RDU - FLT 2146 - AT THE GATE, SMOEK AND FLAME GENERATED FROM ROW 3EF PASSENGER SERVICE UNIT. AIRPORT FIRE DEPARTMENT ARRIVED AND PUT FIRE OUT WITH WATER FROM…
- 21 Jun 1999
Socket, defective
DFW - DURING OVERNIGHT, FORWARD EMERGENCY EXIT FLOOR LIGHT AT FORWARD ENTRY DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLOOD LIGHT SOCKET AT FORWARD ENTRY…
- 25 Dec 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT STRIP INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED…
- 1 Aug 1998
Coalescer, contaminated
ORD - FLT 832 - AFTER TAKEOFF ORD, A STRONG HEAVY SMELL OF BURNING RUBBER AND ELECTRICAL WIRING WAS NOTED. DECLARED EMERGENCY, TURNED OFF RECIRCULATING FANS…
- 16 Feb 1998
Light, loose
ORD - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT LIGHT INOPERATIVE AT ROW 9. RE-SECURED EMERGENCY EXIT LIGHT STRIP AT ROW 9. SYSTEM GROUND CHECKED, NORMAL…
- 29 Jul 1997
Schrader Valve, loose
TUL - FLT 1031 - AFTER T/O, LANDING GEAR HANDLE WOULD NOT RAISE COMPLETELY UP. RECYCLED HANDLE TWICE AND HANDLE RAISED, HOWEVER, NLG RED LIGHT REMAINED…
- 7 Apr 1997
Light, inoperative
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AFT OF PASSENGER SEAT ROW 25 INOPERATIVE. REPLACED DAMAGED SECTION OF EMERGENCY FLOOR LIGHT STRIP JUST…