- 14 Aug 2026
Door, no discrepancy
THE GATE AGENT REPORTS THAT THE MAIN BOARDING DOOR, SPECIFICALLY THE HANDLE, IS HARD TO OPEN/OPERATE. DOOR OPERATES AS INTENDED IAW AMM 52-11-00 COULD NOT…
- 17 Jul 2026
Trunnion, damaged
FLAP FAIL/ FLAP LO RATE ON FERRY FLIGHT. (REPEATED) REF EAML 116202132 FLAP FAIL/ FLAP LO RATE. "TRANSFERRED TO NRWC 748-DFW-02197" EMERGENCY DECLARED. REF…
- 17 Jul 2026
Flap System, faulted
FLAP FAIL IN CRUISE EMERGENCY DECLARED. (4TH REPEAT EVENT) CHECKED CMC. CONFIRMED SQK. REVIEWED FIM 27-50-00-810-803-A VISUALLY INSPECTED ALL FLAP ACUATORS TO…
- 16 Jul 2026
Sensor, faulted
FLAP FAIL ON EICAS UPON ARRIVAL INTO KLSE. RAN QRH; LANDED WITH SLAT (3)/FLAP 0. (3RD REPEAT EVENT). TROUBLESHOOTING REPEAT FLAP FAIL WITH CMC (27512009ACE) L…
- 15 Jul 2026
Flap System, malfunctioned
FLAP FAIL DURING DESCENT. RAN CHECKLIST HAD SLATS 3 FLAPS 0 FOR LANDING. EMERGENCY DECLARED. (REPEATED EVENT). PENDING CORRECTIVE ACTION.
- 15 Jul 2026
Flap System, malfunctioned
WHILE CONFIGURING FOR APPROACH INTO MSN AT 210 KTS, THE FO WAS PF AND CALLED FOR FLAPS 1. I SELECTED FLAPS 1 AND SHORTLY GOT A FLAP FAIL EICAS MESSAGE. WE RAN…
- 8 Jul 2026
Power Supply, inoperative
EMERGENCY LIGHT IN FLIGHT DECK INOPERATIVE. R & R RT NR 1 EMERGENCY-LIGHT POWER UNIT. OPS CHKD GOOD IAW AMM 33-50-01.
- 26 Jun 2026
Actuator, leaking
HYD LO QTY 3 RECEIVED IN FLIGHT. 18% INITIAL. DOWN TO 14% UPON LANDING. EMERGENCY VEHICLES SAW HYDRAULIC FLUID LEAKING AT A SIGNIFICANT RATE FROM THE TAIL…
- 28 Jan 2026
Skin, cracked
LEFT WING LOWER SKIN, JUST AFT OF SPAR 1 AND INBD OF RIB 17, HAS 1 CRACK AND APPROXIMATELY 6" LONG CRACK, VERIFIED WITH EDDY HFEC, FOUND LEAKING FUEL DURING…
- 14 Oct 2024
Steering Sys, faulted
STEERING FAIL MESSAGE DISPLAYED W/ ENG1 & APU ON. AIRCRAFT TOWED INTO GATE INTERROGATED CMC. FOLLOWED FIM TASK 32-52-00 STERRING FAIL MSG CLEARED. OPS CHECK…
- 16 Apr 2024
Battery, malfunctioned
AFT GALLEY EMERGENCY LIGHTS WONT ILLUMINATE COMPLETE:AFTER FURTHER INVESTIGATION FOUND #4 EMERGENCY BATTERY TO BE MALFUNCTIONING. REMOVED AND REPLACED THE #4…