N745JB
2005 Embraer ERJ 170-100 SE standard FAA →
registration
- 2005
earlier registrations
1 past record
service difficulty reports
20 reports
- 2 Nov 2026
Indication Sys, faulted
DOOR PAX FWD OPEN WARNING EICAS MSG CAME ON DURING FLIGHT ON APPROACH. ACFT WAS AT APPROXIMATELY 3,000' MSL. SYS STATUS PAGE SHOWED L1 DOOR OPEN. FA1 VERIFIED…
- 15 Oct 2026
Radio, failed
INTERMITTENT RADIO FAILURE LOST COMM 1, COMM 2 INTO ORD. WE SAY STUCK MIC ON COMM 1. WE TRIED ALL MEANS TO CLEAR VIA YOKE, DASH AND HAN HELD MIC. COMM2 ALSO…
- 9 Oct 2026
Engine, unserviceable
ENGINE TWO FAILURE ON TAKEOFF BELOW 40 KNOTS. ENGINE TWO FAILED MESSAGE. NO FIRE. NO FLUID LEAKS. NO ABNORMAL SMELLS. PICS ATTACHED OF OBJECTS IN TAILPIPE OF…
- 4 May 2026
Doubler, corroded
2 AREAS OF BLENDED CORROSION ON CO-PILOTS COCKPIT FLOOR DOUBLER OUT OF LIMITS, ONE AT FR 11, INBD OF CO-PILOTS INBD SEAT TRACK, AND ONE BETWEEN FR 11 AND 12…
- 4 May 2026
Doubler, corroded
SSI# 53-10-026: BLENDED CORROSION ON PILOTS COCKPIT FLOOR DOUBLER OUT OF LIMITS AT FR 9, INBD OF PILOTS SEAT INBD SEAT TRACK. (MAJOR REPAIR) (LEVEL 2…
- 22 Apr 2026
Floorbeam, corroded
SSI 53-10-027: RH GALLEY FLOOR BEAM CORRODED AT FR 15. (MAJOR REPAIR) (LEVEL 2 CORROSION) PERFORMED PERMANENT REPAIR TO RH GALLEY FLOOR BEAM AT FR 15 IAW ERJ…
- 22 Apr 2026
Strap, corroded
SSI 52-46-001 POSSIBLE CORROSION FOUND AT MULTIPLE SPOTS AROUND THE SURROUND FRAME ON EXTERNAL SIDE OF MIDDLE AVIONICS HATCH. (MAJOR REPAIR) (LEVEL 2…
- 22 Apr 2026
Stringer, corroded
SSI 53-23-007: STRINGER 23R IS CORRODED BTWN FR 88-89. (MAJOR REPAIR) (LEVEL 1 CORROSION) REMOVED AND REPLACED STRINGER 23R BETWEEN FR80 AND 90A IAW ERJ 170…
- 22 Apr 2026
Stringer, corroded
SSI 53-23-003: STRINGER 21R CORRODED BTWN FR 89-90. (MAJOR REPAIR) (LEVEL 2 CORROSION) ACCOMPLISHED REPAIR OF STGR 21R BTW FR 88-90A IAW ERJ 170 SRM…
- 22 Apr 2026
Stringer, corroded
SSI 53-23-003: STRINGER 21L CORRODED BTWN FR 88-89. (MAJOR REPAIR) (LEVEL 1 CORROSION) PERFORMED PERMANENT REPAIR TO STRINGER 21L BETWEEN FR 86 AND FR 90A IAW…
- 22 Apr 2026
Stringer, corroded
STRINGER 19R CORRODED BTWN FR 88-89. (MAJOR REPAIR) (LEVEL 2 CORROSION) REMOVED AND REPLACED STRINGER 19R BETWEEN FR 80 AND FR 90A IAW ERJ 170 SRM 51-40-08.
- 18 Apr 2026
Floorbeam, corroded
FWD GALLEY LH CENTER FLOOR BEAM HAS AREA OF CORROSION AT FR 19. (MAJOR REPAIR LEVEL 2 CORROSION) PERFORMED PERMANENT REPAIR TO FWD GALLEY LH CENTER FLOOR BEAM…
- 18 Apr 2026
Seat Track, corroded
SSI 53-21-005: RH CENTER SEAT TRACK HAS AREA OF CORROSION BTWN FR 30-31. (MAJOR REPAIR) (LEVEL 2 CORROSION) PERFORMED PERMANENT REPAIR TO RH CENTER SEAT TRACK…
- 18 Apr 2026
Crossbeam, corroded
SSI 53-23-005. CABIN FLOOR FR 84 CROSSBEAM CORRODED AT LH SIDE. (MAJOR REPAIR) (LEVEL 2 CORROSION) PERFORMED PERMANENT REPAIR TO CABIN FLOOR FR 84 CROSSBEAM…
- 15 Apr 2026
Retainer, gouged
FWD CARGO DOOR LOWER SEAL RETAINER IS GOUGED IN SEVERAL SPOTS. (MAJOR REPAIR) REMOVED AND REPLACED FWD CARGO DOOR LOWER SEAL RETAINER IAW ERJ 170 SRM 51-40-08.
- 14 Apr 2026
Retainer, gouged
FWD PAX DOOR CUTOUT SEAL RETAINER FLANGE IS GOUGED. (MAJOR REPAIR) BLENDED 5EA MARKED GOUGES ON FWD PAX DOOR SEAL RETAIN IAW ERJ 170 SRM 51-10-03 AND FOUND…
- 8 Apr 2026
Light, damaged
EMERGENCY PHOTOLUMINESCENT INDICATOR STRIP LIGHT RH SIDE # 1,2,3,4,7,9 ,12 AND LH #7 AND 8 ARE DAMAGED. REMOVED AND REPLACED EMERGENCY PHOTO-LUMINESCENT…
- 8 Apr 2026
Battery, inoperative
AFT SVC DOOR LOWER EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY-LIGHT ELECTRICAL POWER UNIT NR 4 IAW AMM 33-50-01. BOND CHECK GOOD. AFT…
- 8 Apr 2026
Shear Tie, corroded
SHEAR TIE AT FR 88 BTWN STGRS 27R-28R CORRODED. LVL2 CORROSION COMPLETE:RAR SHEAR TIE AT FR 88 STGR 27R-28R IAW SRM 51-40-08.
- 26 Sep 2025
Power Supply, inoperative
OVERHEAD EMERGENCY LIGHT BY ROW 16 INOP "TRANSFERRED TO NRWC 745-ORD-01355" REF. NRWC# 745-ORD-01355. REPLACED UPPER AFT EMERGENCY LIGHT POWER UNIT IAW…