service difficulty reports
22 reports
- 4 Mar 2001
Controller, failed
AUTO PRESSURIZATION FAILED DURING CLIMB. *S/D* THE PRESSURE CONTROLLER FAILED. REPLACED THE ELECTRONIC PRESSURE CONTROLLER.
- 15 Oct 2000
Light, intermittent
OPERATIONS REPORTED THAT WHEN REMOVING POWER FROM THE AIRCRAFT THE FORWARD EMERGENCY LIGHT REMAIND ON AND CYCLING OF EMERGENCY LIGHTS DID NOT HELP. *S/D*…
- 20 Sep 2000
Actuator, leaking
ON TAKEOFF THE OUTBOARD FLAPS WOULD NOT RETRACT BEYOND POSITION 2. RETURNED TO ORD. ON APPROACH TO GATE SYSTEM A HYDRAULIC FLUID QUANTITY WENT TO ZERO. *S/D*…
- 9 Mar 2000
Battery Pack, inoperative
AN EIGHT FOOT SECTION OF EEL LIGHTS FROM ROW 24 TO 27 IS INOPERATIVE. *S/D* REPLACED BATTERY PACK AND POWER STRIP.
- 20 Dec 1999
Fire Loop, out of position
ENGINE 1 STRUT OVERHEAT LIGHT CAME ON. COMPLETED IN FLIGHT ENGINE SHUTDOWN, LIGHT REMAINED ON. *S/D* THE STRUT OVERHEAT LIGHT ILLUMINATION IN-FLIGHT WAS AN…
- 1 Oct 1999
Access Panel, loose
PASSENGER REPORTED FUEL DRAINING FROM LEFT WING TIP. CREW REPORTED QUANTITY DECREASING. RETURNED TO ABQ. *S/D* TORQUED NR 15 LEFT HAND WING ACCESS PANEL.
- 2 Aug 1999
Bulkhead Chord, corroded
THE FORWARD EDGE OF THE CHORD AT STATION 1183 BULKHEAD LBL 24, WL 209 WAS CORRODED BEYOND THE SRM ALLOWABLE LIMIT. DAMAGE WAS TRIMMED OUT AND AREA WAS…
- 30 Jul 1999
Spar, chafed
THE VERTICAL STABILIZER MID SPAR CHORD AT FIN STATION 215 ON THE LT SIDE WAS FOUND CHAFED TO BELOW THE MINIMUM ALLOWABLE THICKNESS OF THE CHORD. THE DAMAGED…
- 30 Jul 1999
Rib, cracked
DURING INSPECTION AND INSTALLATION OF THE PREVENTIVE MOD PER SERVICE BULLETIN727-57-0012 AS MANDATED BY AD94-07-08 AND AD90-06-09 ON THE LBL 70.5 RIB CHORD AT…
- 20 Jul 1999
Floorbeam, corroded
CORROSION DAMAGE WAS FOUND ON THE STATION 1050 FLOORBEAM UPPER FLANGE AT RRL 30. THE RESULTING BLENDOUT WENT BEYOND ALLOWABLE LIMITS FOR MATERIAL REMOVAL. THE…
- 19 Jul 1999
Floorbeam, corroded
CORROSION DAMAGE WAS FOUND ON THE STATION 1130 FLOORBEAM UPPER FLANGE FROM RBL 15 TO 24. THE RESULTING BLENDOUT WENT BEYOND THE ALLOWABLE LIMITS FOR MATERIAL…
- 7 Jan 1999
Duct, broken
FOUND NR 6 LEADING EDGE SLAT HEAT TUBE BROKEN AT SWIVEL POINT IN RIGHT WING. *S/D* FOUND BROKEN ANTI ICE DUCT. REPLACED DUCT ASSY AND SHAFT ASSY OF NR 6 SLAT…
- 23 Jun 1998
Light, inoperative
FORWARD ENTRY DOOR INTERIOR EEL LIGHT INOPERATIVE. *S/D* REPLACED LIGHT ASSY.
- 1 Mar 1998
Duct, failed
NR 1 ENGINE STRUT OVERHEAT LIGHT GOES OUT WHEN BLEED SHUT OFF. *S/D* THE SHORT FLEX DUCT WAS LEAKING. REPLACED FLEX DUCT. ALSO, REPLACED THE ANTI-ICE VALVE…
- 2 Aug 1997
Connector, corroded
OUTBOARD FLAPS WILL NOT MOVE BEYOND 2 DEGREES. INBOARD FLAPS ARE DOWN AT SELECTED 5 DEGREES AND LEADING EDGE DEVICES ARE OPERATING. OUTBOARD FLAPS WILL NOT GO…
- 11 Jun 1997
Switch, failed
AIRCRAFT RETURNED TO GATE WITH B-SYSTEM LOW PRESSURE WARNING LIGHT. *S/D* REPLACED HYDRAULIC PRESSURE SWITCH ASSEMBLY DUE TO FAILURE.
- 7 Jan 1997
Seam, leaking
SLIDE REMOVED FROM DOOR 2R FOR AIR CRUISERS SERVICE INFORMATION LETTER 25-98 DEVELOPED AN INFLATION TUBE SEAM LEAK DURING SHOP TEST. SLIDE SCRAPPED.
- 27 Dec 1996
Fan, failed
CREW REPORTS, SMOKE SMELL IN AIRCRAFT WITH LEFT PACK RUNNING. *S/D* REPLACED FROZEN LT PACK COOLING FAN.
- 17 May 1996
Battery Pack, discharged
EMERGENCY LIGHT AT ROW 21 FAILED TO TEST PER CREW. REPLACED BATTERY PACK AND LIGHT ASSEMBLY. CHECKS OKAY.
- 16 Feb 1996
Pack, odor
FUMES IN COCKPIT WITH PACKS RUNNING. SUPPLEMENTAL DATA UPDATE: OPERATED BOTH PACKS FOR 1 HOUR AND NO FUMES NOTICED.
- 25 Oct 1995
Air Distribution, odor
FUMES IN CABIN, SUSPECT APU. ACCOMPLISHED TROUBLE SHOOTING PER MM 49-00-08 H8. CLEANED ACCESSORY CASE AT PUMP AREA, CHECKED VENT, RAN APU AND BOTH PACKS HOT…
- 20 Oct 1995
Aural Warn Mod, malfunctioned
DURING ENGINE FIRE WARNING TEST, FOUND WARNING BELL TO BE INTERMITTENT. REPLACED AURAL WARNING MODULE M6. OPERATIONAL CHECKED NORMAL WITH NO FURTHER PROBLEMS…