N74318
1969 Boeing 727-231 standard FAA →
aircraft radio
1 past record
earlier registrations
1 past record
- 1969
service difficulty reports
37 reports
- 3 Jan 2001
Outflow Valve, obstructed
CLIMBING THROUGH 18000 FT CABIN STARTED TO CLIMB, UNABLE TO CONTROL IN AUTO OR MANUAL. DESCENDED TO 10000 FT, CABIN LEVELED OFF AT 8000 FT. RETURNED TO…
- 20 Nov 2000
Door Frame, cracked
CRACK FOUND ON NR 1 CARGO DOOR CUTOUT FRAME WEB AT BS 620R ADJACENT TO NR 6 DOOR STOP. CORRECTIVE ACTION: FABRICATED, ALODINED, PRIMED AND INSTALLED DOUBLER,…
- 19 Oct 2000
Warning Light, activated
ON PREFLIGHT STAB OUT OF TRIM LIGHT ILLUMINATED, WHILE IN PROCESS OF PLACARDING, CREW AND MAINTENANCE SMELLED SMOKE COMING FROM FWD PANEL. CORRECTIVE ACTION:…
- 29 Dec 1999
Bleed Valve, worn
DURING ENGINE RUN ACCELERATION PRIOR TO TAKEOFF ROLL ENGINES WERE STABILIZED ABOUT 1.4 EPR AND WE HEARD A LOUD BANG. AT ABOUT 1.7 EPR AFTER CHECKING ALL THREE…
- 20 Oct 1999
Wire, damaged
ALL EMERGENCY LIGHTS INOPERATIVE. REPAIRED DAMAGED WIRES BEHIND CONTROL PANEL, OPS CHECK GOOD. (M)
- 4 Oct 1999
Actuator, malfunctioned
ON TAKEOFF, WHEN FLAPS AND LEADING EDGE DEVICES WERE RETRACTING, NR 7 SLAT FAILED TO RETRACT, RECYCLED BUT REMAINED EXTENDED. AIR TURN BACK TO (VIT). UPON…
- 4 Oct 1999
Actuator, malfunctioned
ON TAKEOFF, WHEN FLAPS AND LEADING EDGE DEVICES WERE RETRACTING, NR 7 SLAT FAILED TO RETRACT, RECYCLED BUT REMAINED EXTENDED. AIR TURN BACK TO (VIT). UPON…
- 9 Jun 1999
Gcu, failed
NR 1 AND NR 2 GENERATOR UNDER EXCITOR LIGHTS ILLUMINATED, TRIPPED BOTH GENERATORS. REMOVED AND REPLACED NR 2 GCU, OPS CHECK NORMAL. (M)
- 2 Mar 1999
Instrument Amp, c1 shorted
FLIGHT DIRECTOR BANK INDICATOR INCORRECT. AIR TURN BACK TO EAST MIDLANDS. REMOVED AND REPLACED NR 1 INSTRUMENT AMP AND THE NR 1 VERTICAL. OPS CHECK GOOD IAW…
- 12 Feb 1999
Rod, loose
SEVERE VIBRATION IN FLIGHT. RETURNED TO EDI. ON POST FLIGHT WALK AROUND FOUND REAR AFT CARGO DOOR OPEN. VISUAL INSPECTION OF AFT CARGO DOOR REVEALED INTERNAL…
- 26 Jan 1999
Outflow Valves, dirty
CABIN PRESSURIZATION CONTINUES TO CLIMB AFTER LEVEL OFF AT 100-200 FEET PER MINUTE. MANUAL AND AUTO MODES FAIL TO CONTROL CABIN RISE. AIR TURN BACK TO BGY.…
- 11 Sep 1998
Light, inoperative
ON POSTFLIGHT, CABIN DOOR EMERGENCY EXIT LIGHT INOPERATIVE. GENERATED FROM MAINTENANCE REPORT. REPLACED CABIN DOOR EMERGENCY EXIT LIGHT IAW MM CHAPTER 33. (M)
- 10 Jul 1998
Generator, malfunctioned
DURING CRUISE FLIGHT, CREW NOTICED ALL LIGHTS IN COCKPIT, RADAR SCREEN, AND GPS SCREEN WOULD FLASH ON AND OFF EVERY FEW MINUTES. KILOWATTS ON THE NR 1 WOULD…
- 10 Jul 1998
Voltage Reg, malfunctioned
DURING CRUISE FLIGHT, CREW NOTICED ALL LIGHTS IN COCKPIT, RADAR SCREEN, AND GPS SCREEN WOULD FLASH ON AND OFF EVERY FEW MINUTES. KILOWATTS ON THE NR 1 WOULD…
- 10 Jul 1998
Generator, malfunctioned
DURING CRUISE FLIGHT, CREW NOTICED ALL LIGHTS IN COCKPIT, RADAR SCREEN, AND GPS SCREEN WOULD FLASH ON AND OFF EVERY FEW MINUTES. KILOWATTS ON THE NR 1 WOULD…
- 30 Jun 1998
Switch, inoperative
NR 3 OIL FILTER BYPASS LIGHT CAME ON WHEN TAKEOFF POWER WAS SET. EXTINGUISHED AFTER CLEARING RUNWAY. GENERATED FROM PILOT REPORT. REMOVED AND REPLACED NR 3…
- 25 May 1998
Battery Charger, failed
ON POST-FLIGHT INSPECTION, FOUND THE BATTERY VOLTAGE TO BE ZERO. AFTER CONSULTING WITH MAINTENANCE (BRUSSELS), FOUND A 50-AMP CIRCUIT BREAKER IN LOWER 48…
- 22 Mar 1998
Light, inoperative
DURING SERVICE CHECK, FOUND EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED CABIN EMERGENCY EXIT LIGHT IAW 33-00. OPS CHECK GOOD. (M)
- 15 Dec 1997
Sensor, dirty
RIGHT MAIN GEAR RED LIGHT ON. CLEANED UP LOCK SENSOR. CHECK OK PER MM 32-00-00. (X)
- 4 Nov 1997
Linkage, disconnected
ENGINE NR 3 COULD NOT REDUCE POWER, PULLED THROTTLE BACK, NO CHANGE. SHUT NR 3 ENGINE DOWN. FOUND LINKAGE ON FUEL CONTROL DISCONNECTED. RECONNECTED LINKAGE.…
- 31 Oct 1997
Floor Pan, corroded
MAIN CABIN, FLOOR PAN HAS CORROSION APPROX FS 1160. CUT OUT DAMAGED AREA, FABRICATED REPAIR PER 51-40-02. INSTALLED FILLER AND DOUBLER PER SRM 51-40-02. (M)
- 31 Oct 1997
Stringer, cracked
FORWARD CARGO PIT LEFT SIDE, STRINGER 19L HAS .125 INCH CRACK AT APPROX FS 626 ON INNER FLANGE. STOP DRILLED CRACK .25 INCH PER SRM 53-10-03. (M)
- 31 Oct 1997
Web, cracked
AFT AIRSTAIR, RIGHT SIDE WEB CRACK TO BOTTOM LIGHTING HOLE AT FS 1265. STOP DRILLED CRACK, FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-02. (M)
- 31 Oct 1997
Wire, broken
EMERGENCY LIGHTS INOP. FOUND BROKEN WIRE AT PIN NR 9. REPINNED CONNECTOR PER MM. SYSTEM OPS CHECK NORMAL PER MM 33-50-01. (M)
- 6 Oct 1997
Seat Track, corroded
MAIN CABIN, LEFT OUTBOARD SEAT TRACK HAS CORROSION INSIDE AND OUTSIDE FS 344 TO 360. REMOVED LEFT OUTBOARD TRACK FS 344 TO 480. INSTALLED NEW SEAT TRACK…
- 6 Oct 1997
Seat Track, corroded
RIGHT INBOARD SEAT TRACK HAS CORROSION FROM FS 420 TO 440. SEAT TRACK SECTION REPLACED FROM FS 360 TO 480 IAW SRM 53-10-05. (M)
- 6 Oct 1997
Seat Track, corroded
MAIN CABIN RIGHT OUTBOARD SEAT TRACK HAS CORROSION FROM FS 360 TO 480. REPLACED SEAT TRACK SECTION FROM FS 360 TO 480 IAW SRM 53-10-05. (M)
- 14 Sep 1997
Seat Track, corroded
MAIN CABIN LEFT INBOARD SEAT TRACK HAS CORROSION FS 360 TO 480. REPLACED SEAT TRACK SECTION FROM FS 360 TO 480 IAW SRM 53-10-05. (M)
- 10 Sep 1997
Seat Track, cracked
MAIN CABIN LEFT OUTBOARD SEAT TRACK HAS CRACKS FS 1050. SEAT TRACK SECTION REPLACED FROM FS 1050 TO 1090 IAW SRM 53-10-05. (M)
- 9 Sep 1997
Seat Track, corroded
MAIN CABIN, RIGHT INBOARD SEAT TRACK HAS CORROSION ON BOTH FLANGES FROM FS 360 TO 400. REPLACED SEAT TRACK SECTION FROM FS 360 TO 480 IAW SRM 53-10-05. (M)
- 9 Jan 1997
Battery, discharged
AFT AIRSTAIRS EMERGENCY LIGHT INOP. CLEANED BATTERY PACK AND CHANGED BATTERIES. OPS CHECKS GOOD IAW MM 33-50-0. (M)
- 13 Nov 1996
Megaphone, intermittent
ON PREFLIGHT, FOUND FORWARD MEGAPHONE INTERMITTENT. REMOVED AND REPLACED FORWARD MEGAPHONE. OPS CHECK OK IAW MM 25-60-0. (M)
- 28 Oct 1996
Battery, discharged
EMERGENCY PATH LIGHTING DIM AT STATION 1030-1183. REMOVED AND REPLACED BATTERY POWER CENTER CEILING STATION 1090. OPS CHECKS NORMAL IAW MM 33-50-71. (M)
- 23 May 1996
Battery Pack, discharged
R1 DOOR SLIDE LIGHT INOPERATIVE. REPLACED BATTERY PACK, OPS CHECKS GOOD. MM 33-50-00.
- 16 Oct 1995
Cables, lack of lube
RIGHT MAIN MANUAL GEAR EXTENSION CABLES ARE BINDING. REPORTED DURING MANUAL EXTENSION AFTER 'A' SYSTEM FAILURE. LUBED CABLES AND ACCOMPLISHED GEAR SWING AND…
- 16 Oct 1995
Hyd Tube, chafed
'A' SYSTEM HYDRAULIC QUANTITY DROPPED TO ZERO IN ABOUT 20 MINUTE TIME SPAN. FOLLOWED 'A' SYSTEM FAILURE CHECK LIST, MANUALLY LOWERED LANDING GEAR AND FLAPS.…
- 14 Jul 1995
Door, jammed
DURING DITCHING DEMONSTRATION, FORWARD OVERHEAD RAFT COMPARTMENT DOOR JAMMED ON OPENING. FOUND INERTIA REEL JAMMED. SEVERAL TEETH BROKEN ON GEARS. (X)