N741CK
1989 Boeing 747-4H6 experimental, research and development FAA →
registration
- 1989
earlier registrations
1 past record
service difficulty reports
247 reports
- 4 Sep 2026
Lamp, dim
COCKPIT ENTRANCE EMERGENCY LIGHT IS DIM
- 11 Aug 2026
Seat Track, corroded
UPPER DECK SEAT TRACK APPROX RBL 40 STA 450 HAS EVIDENCE OF CORROSION
- 11 Aug 2026
Stringer, corroded
POSSIBLE CORROSION ON STRINGER 49L IN AFT CARGO AT BS 1860 - 1880.
- 11 Aug 2026
Stringer, corroded
POSSIBLE CORROSION ON STRINGER 48L IN AFT CARGO AT BS 1920-1940.
- 11 Aug 2026
Splice Plate, corroded
EVIDENCE OF CORROSION ON RT WING IN L/E CAVITY APPROX WS 1454 TWO INCHES FWD OF FRONT SPAR
- 11 Aug 2026
Stringer, cracked
UPPER DECK R/H SIDE STRINGER 8R UPPER SURFACE HAS POSSIBLE CRACK BY HILOK FASTENER JUST FWD OF BODY FRAME 460
- 11 Aug 2026
Panel, cracked
L/H CANTED PRESSURE DECK COMPOSITE PANEL STA 1240 LBL 70-80 DAMAGED
- 11 Aug 2026
Floorbeam, corroded
FLIGHT DECK FLOORBEAM UPPER SURFACE CORRODED AT WEB SEAM BS 330 LBL 41 TO RBL 41.
- 11 Aug 2026
Tension Tie, cracked
2 EACH CRACK INDICATIONS IN FASTENER HOLES IN THE FRAME COMMON TO THE TENSION TIE AT STA 1160 R/H SIDE
- 11 Aug 2026
Tension Tie, cracked
INNER FRAME DOUBLER CRACKED AT STA 1160 R/H
- 11 Aug 2026
Seat Track, corroded
UPPER DECK SEAT TRACK FOUND TO BE CORRODED AT STA 720-780 LBL 30
- 11 Aug 2026
Seat Track, corroded
UPPER DECK SEAT TRACK CORRODED AT STA 720 LBL 24
- 11 Aug 2026
Stiffener, corroded
EVIDENCE OF CORROSION ON R/H WING IN L/E CAVITY ON FWD SPAR STIFFENER APPROX WS 1513
- 11 Aug 2026
Floor Support, corroded
UNDER SIDE OF PANEL SUPPORT HAS CORROSION IN AFT BULK CARGO COMPARTMENT APPROX STA 2160 RBL 38-48
- 11 Aug 2026
Floorbeam, corroded
UNDERSIDE OF FLOOR PANEL SUPPORT HAS CORROSION IN AFT BULK CARGO COMPARTMENT APPROX STA 2160 LBL 5-12
- 11 Aug 2026
Floor Support, corroded
UNDER SIDE OF PANEL SUPPORT HAS CORROSION IN AFT BULK CARGO COMPARTMENT APPROX STA 2160 RBL 12
- 11 Aug 2026
Stringer, corroded
POSSIBLE CORROSION ON S-49L IN AFT CARGO AT STA 1860-1880.
- 11 Aug 2026
Stringer, corroded
POSSIBLE CORROSION ON S-48L IN AFT CARGO AT BS 1920-1940
- 11 Aug 2026
Stringer, corroded
CORROSION FOUND AT BS 1965 ON STRINGER 51R.
- 11 Aug 2026
Battery Pack, no test
EMERGENCY LIGHT POWER SUPPLY AT APPROX STA 830 BEHIND GALLEY FAILS OPS CHECKED
- 11 Aug 2026
Battery Pack, discharged
L/H SIDE UPPER DECK DOOR BATTERY HAS LOW VOLTAGE
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553BB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553EB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 545BB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 546AB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 546BB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552EB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553GB HAS CORROSION
- 6 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 545AB HAS CORROSION
- 6 Aug 2026
Seat Track, corroded
UPPER DECK SEAT TRACK APPROX RBL 40 STA 450 HAS EVIDENCE OF CORROSION
- 6 Aug 2026
Beam, cracked
CENTER WING TANK INTERIOR NR 2 SPANWISE BEAM WEB HAS POSSIBLE CRACK AT APPROX LBL 90
- 6 Aug 2026
Angle, cracked
CRACKED ANGLE AT NAC 354 IN LOWER AFT TORQUE BOX # 2 PYLON
- 6 Aug 2026
Tension Tie, cracked
VISIBLE CRACK APPROX 2 INCHES LONG FOUND IN LT SIDE OF TENSION TIE AT STA 1160
- 6 Aug 2026
Stiffener, corroded
EVIDENCE OF CORROSION ON RT WING IN L/E CAVITY ON FWD SPAR STIFFENER APPROX WS 1513
- 6 Aug 2026
Tension Tie, cracked
TENSION TIE AT STA 1120 FOUND TO HAVE CRACK INDICATION AT I/B FASTENER HOLE COMMON WITH L/H SIDE FRAME
- 6 Aug 2026
Stringer Clip, cracked
O/B FASTENER HOLE WITH POSSIBLE CRACK INDICATION FOUND AT STA 1120 COMMON WITH FRAME, STRINGER CLIP AND TENSION TIE
- 6 Aug 2026
Tension Tie, cracked
FOUND 2EA CRACK INDICATIONS IN FASTENER HOLES AS MARKED AT STA 1160 TENSION TIE TO FRAME ATTACHMENT LOCATIONS L/H
- 6 Aug 2026
Tension Tie, damaged
TENSION TIE AT STA 1120 RT SIDE HAS DAMAGED FASTENER HOLE
- 6 Aug 2026
Tension Tie, cracked
CRACK INDICATIONS FOUND ON FRAME DOUBLER AT STA 1160 L/H, S-10L
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 L/H OUTER FLANGE STA 306
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 RT OUTER FLANGE STA 339
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 R/H OUTER FLANGE STA 310.
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 LT OUTER FLANGE BS 326.
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 L/H OUTER FLANGE STA 310
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 L/H OUTER FLANGE STA 323
- 6 Aug 2026
Intercostal, cracked
CRACK FOUND AT INTERCOSTAL BL 0 RT INNER FLANGE BS 337
- 6 Aug 2026
Web, cracked
CRACKED WEB BELOW BULK PIT FLOOR AT STA 2060 RBL 25
- 6 Aug 2026
Seat Track, corroded
MAIN DECK STA 2220-2240 RBL 90 EVIDENCE OF CORROSION. ( SEAT TRACK)
- 6 Aug 2026
Fitting, corroded
POSSIBLE CRACK INDICATION IN BOLT HOLE COMMON WITH OUTER CHORD OF RT SIDE BS 2598 BULKHEAD AT WL 321 FOUND DURING OPEN HOLE HFEC INSPECTION.
- 6 Aug 2026
Stringer, corroded
LOWER R/H BOLT HOLE AT STRINGER 11 CORRODED THROUGHOUT. ( STA 2598)
- 6 Aug 2026
Stiffener, corroded
EVIDENCE OF CORROSION ON L/H WING L/E STIFFENER ON FWD SIDE OF FRONT SPAR AT WS 1421
- 6 Aug 2026
Web, cracked
LEFT HORIZONTAL STAB TIP CLOSURE WEB UPPER CHORD WAS CRACKED
- 6 Aug 2026
Web, cracked
LT HORIZONTAL STAB TIP CLOSURE RIB WEB WAS CRACKED.
- 6 Aug 2026
Door Sill, cracked
E&E BAY BILGE AREA SILL CRACKED AT STA 400 BL 0
- 6 Aug 2026
Angle, cracked
E&E BAY BILGE AREA SILL ANGLE BRACKET CRACKED AT STA 400 LBL 14
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 652AB HAD CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 646BB HAD CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653GB HAD CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653HB HAD CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653FB HAD CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS PANEL CUTOUT 652DB HAD CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 652BB HAD CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 652EB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 652FB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653KB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 652CB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 652GB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653AB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653CB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653BB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653DB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 653EB HAS CORROSION
- 5 Aug 2026
Skin, cracked
DURING HFEC SURFACE INSPECTION OF OUTER SKIN, CRACK INDICATION AROUND FASTENER FOUND AT STA 1456 STR 23L
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 644AB HAS CORROSION.
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 645AB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 645BB HAS CORROSION
- 5 Aug 2026
Skin, corroded
RIGHT WING FUEL TANK ACCESS CUTOUT 646AB HAS CORROSION
- 5 Aug 2026
Skin, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552FB HAS CORROSION
- 5 Aug 2026
Skin, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 544AB HAS CORROSION
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552CB HAS CORROSION.
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553FB HAS CORROSION.
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553AB HAS CORROSION
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553DB HAS CORROSION.
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552DB HAS CORROSION
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553JB HAS CORROSION.
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553HB HAS CORROSION
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 553CB HAS CORROSION
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552GB HAS CORROSION
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552AB HAS CORROSION.
- 5 Aug 2026
Access Panel, corroded
LEFT WING FUEL TANK ACCESS CUTOUT 552BB HAS CORROSION.
- 12 Feb 2025
Web, cracked
LW FIXED TRAILING EDGE BEAM WEB CRACKED ON INBD OF #4 FLAP TRACK FAIRING AT APPROX WBL 255
- 12 Feb 2025
Beam, cracked
LW FIXED TRAILING EDGE BEAM LWR CHORD DAMAGED INBD OF #4 FLAP TRACK FAIRING AT APPROX WBL 255
- 7 Feb 2025
Light, inoperative
EMERGENCY LIGHT AT STA 470 INOP
- 7 Feb 2025
Light, inoperative
MULTIPLE FORWARD UPPER DECK EMERGENCY LIGHTS INOP
- 11 Jul 2024
Battery Pack, no test
R/H UPPER DECK DOOR SLIDE BATTERY PACK FAILS OPS CHECK
- 30 Jun 2024
Battery, unserviceable
100170844 LEFT UPPER DECK DOOR EMERGENCY LIGHT INOPERABLE. REMOVED AND REPLACED POWER SUPPLY BATTERY AND OPERATIONAL CHECK GOOD IAW B747-400 AMM 33-51-04.
- 28 Jun 2024
Fitting, cracked
FOUND FITTING CRACKED AT RH STR-19 AT R5 DOOR
- 28 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE EXTERNAL SKIN HAS EVIDENCE OF LIGHTNING STRIKE RIGHT SIDE APPROX STA 200 AND S-31A
- 27 Jun 2024
Stringer, corroded
FWD CARGO STRINGER 47R HAS CORROSION AT APPROX BS 995
- 27 Jun 2024
Stringer, corroded
FWD PIT STRINGER 42L HAS CORROSION AT APPROX BS 995
- 27 Jun 2024
Hinge Bracket, cracked
FWD CARGO DOOR AFT HINGE HAS CRACKED BRACKET ON THE DOOR SIDE
- 21 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE SKIN HAS EVIDENCE OF LIGHTNING STRIKE RIGHT SIDE APPROX STA 160 AND S-39
- 21 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE EXTERNAL SKIN HAS EVIDENCE OF LIGHTNING STRIKE RIGHT SIDE APPROX STA 160 AND S-47
- 14 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE EXTERNAL SKIN HAS EVIDENCE OF LIGHTNING STRIKE RIGHT SIDE APPROX STA 208 AND S-42A
- 14 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE EXTERNAL SKIN HAS EVIDENCE OF LIGHTNING STRIKE LEFT SIDE APPROX STA 160 AND S-41
- 14 Jun 2024
Skin, damaged
EVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN @ STA 591 ABOVE LS-19
- 14 Jun 2024
Skin, damaged
EVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN @ STA 435 APPROX LS-1
- 14 Jun 2024
Skin, damaged
EVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN @ STA 464 APPROX LS-1
- 13 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE EXTERNAL SKIN HAS EVIDENCE OF LIGHTNING STRIKE RIGHT SIDE APPROX STA 200 AND S-42A
- 11 Jun 2024
Stiffener, cracked
CRACKED STIFFENER FOUND ON R/H NWW SIDEWALL PANEL AT WL 130 STA 320-340 RBL 30
- 11 Jun 2024
Stiffener, cracked
CRACKED STIFFENER FOUND ON L/H NWW SIDEWALL PANEL AT WL 130 STA 320-340 LBL 30
- 5 Jun 2024
Skin, damaged
LOWER HALF OF FUSELAGE EXTERNAL SKIN HAS EVIDENCE OF LIGHTNING STRIKE RIGHT SIDE APPROX STA 160 AND S-42A
- 12 Jan 2024
Seat Track, broken
CAPTAINS RH AFT SEAT TRACK BROKEN
- 11 Jan 2024
Battery, failed
U/P EMERGENCY LIGHTS AT APPROX STA. 700-780 CENTER AND L/H ONLY STAY ON FOR A FEW SECONDS BEFORE TURNING OFF.
- 2 Nov 2023
Light, inoperative
UPPER DECK EMERGENCY LIGHTS AT ABOUT STATION 600 INOP.
- 2 Nov 2023
Rib, cracked
L/E RIB CRACKED AT W.S. 756.95 ON L/H WING.
- 31 Oct 2023
Light, inoperative
UPPER DECK R/H DOOR EMERGENCY LIGHTS INOP.
- 18 Aug 2023
Angle, cracked
BULK PIT STA 1980 RBL 62 FOUND DAMAGED ANGLE.
- 18 Aug 2023
Shim, cracked
BULK PIT STA 2034 RBL 62 FOUND DAMAGED SHIM.
- 1 Jun 2023
Skin, corroded
RIGHT WING UPPER INSTERSPAR SKIN HAS CORROSION AT AFT SPAR AT APPROX WS 492.82 APPROX WBL 237
- 30 May 2023
Fitting, damaged
LH WING OB AILERON #5 WS 1548 HINGE TUB FITTING DAMAGED
- 22 May 2023
Attach Fitting, damaged
LH WING OB AILERON #3 ATTACH FITTING AT WS 1423 HAS DAMAGED UPPER CHORD
- 22 May 2023
Web, damaged
LH WING OB AILERON #3 ATTACH FITTING AT WS 1423 HAS DAMAGED WEB
- 22 May 2023
Attach Fitting, damaged
LH WING OB AILERON #3 ATTACH FITTING AT WS 1423 HAS DAMAGED TUB FITTING
- 16 Jun 2022
Stiffener, cracked
STIFFENER FOUND TO BE CRACKED ON NOSE WHEEL WELL R/H SIDE AT STA 280 TO STA 300 WL140
- 6 Jun 2022
Stringer, cracked
STR 10R HAS CRACK AT STA 460 IN UPPER DECK
- 6 Jun 2022
Tie Clip, cracked
STA 1140 R/H FRAME HAS CRACK INDICATION IN MOST O/B LOWER HOLE AT TENSION TIE ATTACH POINT
- 6 Jun 2022
Tension Tie, cracked
STA 1140 L/H FRAME AT TENSION TIE ATTACH POINT HAS 2 EA CRACK INDICATIONS
- 2 Jun 2022
Stringer, cracked
STR-10R HAS APPROX. 1.5 INCH CRACK AT STA 500 IN UPPER DECK
- 2 Jun 2022
Stringer, cracked
STR-10R HAS APPROX. 2 INCH CRACK AT STA 480 IN UPPER DECK
- 27 May 2022
Fitting, corroded
RH INBOARD ELEVATOR ACTUATOR FITTING HAS EVIDENCE OF CORROSION AT ELEVATOR STA 125
- 27 May 2022
Tension Tie, cracked
STA 1180 R/H TENSION TIE HAS CRACK INDICATION IN FWD CHANNEL
- 18 May 2022
Shear Web, cracked
STR 26L CRACKED AT STA 510
- 18 May 2022
Web, cracked
L/H I/B MID FLAP HAS CRACKED WEB AT OB AFT CORNER WBL 445
- 18 May 2022
Stringer, cracked
STR-10R HAS APPROX 1.5 INCH CRACK AT STATION 500 IN UPPER DECK
- 18 May 2022
Stringer, cracked
STR-10R HAS APPROX 2 INCH CRACK AT STATION 480 IN THE UPPER DECK
- 16 May 2022
Fitting, corroded
LH INBOARD ELEVATOR ACTUATOR O/B FITTING HAS EVIDENCE OF CORROSION.
- 16 May 2022
Fitting, corroded
R/H OUTBOARD ELEVATOR ACTUATOR O/B FITTING HAS EVIDENCE OF CORROSION.
- 16 May 2022
Actuator, corroded
RH INBOARD ELEVATOR ACTUATOR O/B FITTING HAS EVIDENCE OF CORROSION.
- 16 May 2022
None, corroded
RH INBOARD ELEVATOR ACTUATOR I/B SUPPORT FITTING HAS EVIDENCE OF CORROSION.
- 16 May 2022
None, corroded
L/H OUTBOARD ELEVATOR ACTUATOR I/B SUPPORT FITTING HAS EVIDENCE OF CORROSION.
- 13 May 2022
Actuator, corroded
LH OUTBOARD ELEVATOR ACTUATOR FITTING HAS EVIDENCE OF CORROSION.
- 15 Jun 2021
Light, inoperative
L/H UPPER DECK DOOR EMERGENCY LIGHT INOP
- 17 Mar 2021
Light, inoperative
BOTH EMERGENCY LIGHTS ON UPPER DECK R/H EMERGENCY DOOR INOP
- 17 Mar 2021
Light, inoperative
BOTH EMERGENCY LIGHTS ON UPPER DECK L/H EMERGENCY DOOR INOP
- 24 Jul 2020
Battery, no test
R/H UPPER DECK DOOR BATTERY WILL NOT TEST
- 22 Jul 2020
Skin, corroded
AFT CARGO BILGE, APROXIMATELY BS 1630, LBL 6, HAD CORROSION AROUND A DOME NUT ON FUSELAGE SKIN.
- 22 Jul 2020
Stop Fitting, cracked
R3 DOOR FWD FRAME STOP FITTING CRACKED.
- 22 Jul 2020
Light, inoperative
EMERGENCY LIGHT, BS 770 NOT FUNCTIONING.
- 15 Jul 2020
Frame, cracked
STA 800 STR 17 L 2 AFT FRAME FASTENER HOLES HAVE CRACK INDICATION.
- 15 Jul 2020
Frame, cracked
STA 800 STR 23 L UPPER FRAME FASTENER HOLE HAS CRACK INDICATION.
- 15 Jul 2020
Frame, cracked
STA 800 FRAME RT HAS A CRACK INDICATION IN THE FWD LOWER FASTENER HOLE AT STR 17R. REMOVED FOR SB 747-53A2451.
- 15 Jul 2020
Frame, cracked
STA 800 FRAME RH HAS A CRACK INDICATION IN THE AFT UPPER FASTENER HOLE AT STR 17R. REMOVED FOR SB 747-53A2451.
- 15 Jul 2020
Support Beam, corroded
RIGHT WING TRAILING EDGE SUPPORT BEAM'S UPPER SPAR ON THE FORWARD SIDE AT APPROX WBL 279, HAS A 1" DAMAGED AREA WITH EVIDENCE OF CORROSION.
- 15 Jul 2020
Floorbeam, corroded
FLOORBEAM UPPER CORD CORRODED AT STA 2240 - BL 65 NEXT TO L5 DOOR.
- 15 Jul 2020
Floorbeam, corroded
FLOORBEAM UPPER CHORD HAS CORROSION AT STA 2240 APPROXIMATELY AT RBL 72 ON MAIN DECK.
- 9 Jul 2020
Keelbeam, corroded
RT WING GEAR W/W KEAL BEAM UPPER CORD CORRODED AT STA 1350.
- 9 Jul 2020
Structure, cracked
CRACK ON RIGHT HORIZ STAB APPROX STAB STA 560 UPPER CORD.
- 9 Jul 2020
Structure, cracked
LT HORIZONTAL STAB TIP HAS A CRACK ON LOWER CHORD NEAR TRAILING EDGE.
- 9 Jul 2020
Web, cracked
RT STAB TIP WEB IS CRACKED.
- 1 Jul 2020
Stiffener, cracked
NWW TOP PANEL STIFFENER AT RIGHT BL 10 HAS A CRACK AT STA 310.
- 1 Jul 2020
Bracket, cracked
FWD LOWER CARGO COMP AT STA 960 C-TRACK CARGO STOP BRACKET CRACKED.
- 26 Jun 2020
Drain Valve, corroded
FWD PORTABLE WATER TANK DRAIN VAVLE UNDER SERVICE PANEL IS CORRODED
- 26 Jun 2020
Web, cracked
CRACK IN NOSE WHEEL WELL WEB AT STA 290 AT APPROX. RBL 20
- 26 Jun 2020
Structure, cracked
CRACK ON RIGHT HORZ. STAB TIP
- 26 Jun 2020
Reveal, cracked
L5 DOOR REVEAL IS CRACKED AT STA 2231 JUST ABOVE S-17 L APPROX. 1.5" LONG
- 26 Jun 2020
Rib, cracked
UPPER RUDDER HAS A 17 INCH CRACK ON INTERSPAR RIB AT RUDDER STA 146.7 UNDER PANEL 326AL
- 22 Jun 2020
Stiffener, cracked
NLG WW TOP PANEL STIFFENER AT LEFT BL 10 HAS A CRACK AT STA 310.
- 17 Jun 2020
Cargo Track, cracked
FWD LOWER CARGO BAY, BS 960 LBL 24 CARGO TRACK WAS CRACKED.
- 11 Jun 2020
Skin, corroded
LOWER FUSELAGE SKIN, BS 1740 CORRODED.
- 11 Jun 2020
Bulkhead, cracked
BS 2598 LOWER LH BULKHEAD CORNER HAS A CRACK INDICATION AT FASTENER HOLE MARKED "J"
- 2 Jun 2020
Shear Web, cracked
FORWARD OF E & E BAY AT STA 140 TO 160 RT SIDE SHEAR WEB LIGHTNING HOLES CRACKED AT WL 199.8 AT RBL 96.
- 2 Jun 2020
Shear Web, cracked
FORWARD OF E & E BAY AT STA 160 TO 180 RT SIDE SHEAR WEB LIGHTNING HOLES CRACKED AT WL 199.8 AT RBL 96.
- 2 Jun 2020
Shear Web, cracked
FORWARD OF E & E BAY AT STA 140 TO 160 LT SIDE SHEAR WEB LIGHTNING HOLES CRACKED AT WL 199.8 AT LBL 96.
- 22 May 2020
Stop Fitting, cracked
STA 800 FWD DOOR STOP ASSEMBLY WEB CRACKED JUST BELOW STR 24L
- 22 May 2020
Stop Fitting, cracked
STA 800 FWD DOOR STOP ASSEMBLY WEB CRACKED JUST BELOW STR 24R
- 12 Jun 2018
Access Panel, cracked
EVIDENCE OF CRACK ON NR 1 PYLON INBD SIDE ON LOWER LT CORNER OF ACCESS PANEL 452DR APPX MAC STA 282.
- 11 Jun 2018
Switch, intermittent
LEFT UPPER DECK DOOR BATTERY OK SWITCH INTERMITTENT.
- 8 Jun 2018
Light, inoperative
EMERGENCY LIGHT IN UPPER DECK STAIRWELL INOP.
- 6 Jun 2018
Spar, damaged
RIGHT OTBD ELEVATOR WAS DAMAGED ES 256.8. FORWARD SPAR TO COUNTERWEIGHT SUPPORT STRUCTURE.
- 5 Jun 2018
Light, inoperative
UPPER DECK DOORS EMERGENCY LIGHTS FAILS TO ILLUMINATE.
- 18 May 2018
Fuse Pin, cracked
FOUND CRACKS IN 2 OF 4 GREASE HOLES OF LT WING LANDING GEAR SUPPORT BEAM FUSE PIN VIA MAGNETIC PARTICLE INSPECTION.
- 18 May 2018
Fuse Pin, cracked
FOUND CRACKS IN ONE GREASE HOLE OF RT WING LANDING GEAR SUPPORT BEAM FUSE PIN VIA MAGNETIC PARTICLE INSPECTION.
- 17 May 2018
Sign, unserviceable
EXIT SIGN ABOVE COMPUTER CABINET ON CEILING, CAN'T READ.
- 17 May 2018
Reveal, cracked
R5 DOOR STA 2231 BETWEEN 21-22 STR ON REVEAL HAS CRACKED.
- 17 May 2018
Reveal, cracked
L5 DOOR STA 2231 BETWEEN 21-22 STR ON REVEAL HAS CRACK.
- 17 May 2018
Seat Track, corroded
AFT PIT SEAT TRACK AT STA 1850, BBL 24 RIGHT IS CORRODED.
- 17 May 2018
Support Fitting, corroded
RT WING L/E SUPPORT RIB FITTING HAS CORROSION AT OLES 1535.
- 2 Nov 2017
Terminal, broken
UPPER DECK EMERGENCY LIGHT HAS BROKEN TERMINAL STUD.
- 16 Jun 2016
Light, inoperative
LEFT UPPER DECK EMERGENCY DOOR BATTERY OK. LIGHT DOES NOT ILLUMINATE DURING TEST.
- 12 Apr 2016
Attach Angle, cracked
BS 1241 AT STR-6R CREASEBEAM ATTACH ANGLE CRACKED, .5 INCH LONG.
- 5 Apr 2016
Skin, corroded
AFT CARGO DOOR LOWER INNER SKIN HAS MULTIPLE AREAS OF CORROSION AT STATIONS APPROXIMATELY 1883-1871.
- 5 Apr 2016
Skin, corroded
AFT CARGO DOOR LOWER INNER SKIN HAS MULTIPLE AREAS OF CORROSION AT STATIONS APPROXIMATELY 1871-1856.
- 5 Apr 2016
Skin, corroded
AFT PIT CARGO DOOR LOWER INNER SKIN HAS MULTIPLE AREAS OF CORROSION AT BS 1856-1843.
- 5 Apr 2016
Skin, corroded
AFT CARGO DOOR LOWER INNER SKIN HAS MULTIPLE AREAS OF CORROSION AT STATIONS APPROXIMATELY 1843-1828.
- 5 Nov 2015
Skin, corroded
ON POST FLIGHT, FOUND 3 EA RIVETS PULLED IN SKIN AFT OF NR 1 L/E FLAP, LT WING.
- 28 Oct 2015
Fire Warning, false activation
MOMENTARY MAIN DECK FOWARD CARGO FIRE WARNING OCCURED DURING DESCENT THROUGH FL 210 SENT ACM'S TO VERIFY NO FIRE OR SMOKE NOTICED. CONTINUED TO DESTINATION.…
- 28 Oct 2015
Fire Warning, false activation
APPROXIMATELY 1 HOUR AFTER TAKEOFF, AT FL320 MAIN DECK, FORWARD FIRE WARNING ACTIVATED ACM'S VERIFIED NO FIRE OR SMOKE WAS PRESENT. INTERMITTENT FIRE WARNING…
- 27 Oct 2015
Signal Cond Unit, defective
MOMENTARY MAIN DECK FORWARD CARGO FIRE WARNING, SENT ACM'S TO VERIFY, NO FIRE OR SMOKE NOTED, CONTINUED TO DESTINATION, CHECKED MAIN DECK EVERY 20 MINUTES…
- 27 Oct 2015
Fire Warning, intermittent
MOMENTARY MAIN DECK FORWARD CARGO FIRE WARNING, NO FIRE OR SMOKE NOTED, CONTINUED TO DESTINATION, CHECKED MAIN DECK EVERY 20 MINUTES UNTIL ARRIVAL. PERFORMED…
- 24 Jan 2015
Control Unit, failed
IN FLIGHT, R1 WINDOW ARCED AND SMOKE WAS PRODUCED. R & R R1 WINDOW HEAT CONTROL UNIT IAW MM 30-41-01. OPS CHECKS GOOD. R & R R1 WINDOW IAW MM 56-11-01, OPS…
- 27 Jul 2014
Circuit Card, defective
AFTER DEPARTURE, FIRE WARNING BELL KEPT GOING OFF FOR 1 HOUR. R & R MASTER MONITOR B PRINTED CIRCUIT CARD IAW MM 31-51-02. SYS TEST GOOD IAW MM 31-51-00. OPS…
- 9 Jul 2014
Ground Stud, damaged
COCKPIT UPPER AFT FACING DOME LIGHT INOPERATIVE. REPLACE GROUND TERMINAL ON COCKPIT UPPER AFT FACING DOME LIGHT IAW SWPM 20-30-11. LIGHT OPERATIONS CHECK GOOD.
- 9 Jul 2014
Battery Pack, inoperative
AFT UPPER DECK CENTER DOOR CEILING EMERGENCY LIGHT INOPERATIVE. R & R BATTERY PACK. OPS CHECK GOOD IAW AMM 33-51-04.
- 21 Jun 2014
Fire Warning, false activation
FOUR INTERMITTENT MAIN CARGO DECK ZONE 8 FIRE WARNINGS. FIRE, SMOKE, NOT VISUALLY DETECTED. CHECKED EVERY 30 MINUTES. NO FURTHER FIRE WARNINGS OCCURRRED OR…
- 7 Apr 2014
Structure, cracked
CRACK INDICATION NOTED IN FWD CORNER OF THE AFT CARGO DOOR APPROXIMATELY BS 1820.
- 7 Apr 2014
Beam, corroded
AFT CARGO DOOR CLOSEOUT BEAM HAS CORROSION APPROXIMATELY BS 1900.
- 7 Apr 2014
Seat Track, corroded
SEAT TRACK AT STA 680, RBL 45 HAS AREA OF CORROSION.
- 7 Apr 2014
Light, no test
SEVERAL EMERGENCY LIGHTS NEAR AFT UPPER DECK EXIT DOORS, FAILED OPS CHECK.
- 25 Mar 2014
Frame, corroded
BS 1960 FRAME OUTER ANGLE HAS EVIDENCE OF CORROSION AT STRINGER 51L.
- 25 Mar 2014
Sill, corroded
BULK CARGO DOOR CUTOUT LOWER SILL UPPER CHORD CORRODED AT BS 2018 UNDER NUTPLATE.
- 25 Mar 2014
Web, corroded
LOWER SILL WEB HAS EVIDENCE OF CORROSION AT BS 1992.
- 25 Mar 2014
Web, corroded
LOWER SILL WEB HAS EVIDENCE OF CORROSION FROM BS 1980-1990.
- 25 Mar 2014
Sill, corroded
LOWER SILL UPPER ANGLE HAS CORROSION UNDER NUT PLATES FROM BS 1990-2002.
- 20 Mar 2014
Stringer, cracked
STRINGER 51L CRACKED AT BS 2020.
- 20 Mar 2014
Frame, corroded
BS 1820 FRAME INNER FORWARD ANGLE AT RBL 60 HAS AREA OF CORROSION.
- 11 Mar 2014
Floor Support, corroded
BULK CARGO FLOOR SUPPORT, RBL 7.5 HAS EVIDENCE OF CORROSION AT APPROX. BS 2048 UPPER AND LOWER SURFACES.
- 11 Mar 2014
Floor Support, corroded
BULK CARGO FLOOR SUPPORT BL 0 HAS EVIDENCE OF CORROSION AT BS 2048 UPPER AND LOWER SURFACES.
- 11 Mar 2014
Floor Support, corroded
BULK CARGO FLOOR SUPPORT, LBL 7.5 HAS EVIDENCE OF CORROSION AT BS 2048 UPPER AND LOWER SURFACES.
- 7 Mar 2014
Shear Tie, corroded
CORROSION AT BS 1580 FUSELAGE FRAME SHEAR TIE BETWEEN S50-51L.
- 7 Mar 2014
Strap, corroded
CORROSION ON STRAP FOR L1 WINDOW UPPER OTBD CORNER.
- 6 Mar 2014
Tension Tie, cracked
LEFT TENSION TIE AT BS 1180 HAS CRACK INDICATION IN TENSION TIE FASTENER HOLE.
- 6 Mar 2014
Angle, corroded
LEFT HORIZONTAL STAB, INSIDE T/E CAVITY; CORROSION ON ANGLE AT ELEVATOR STA. 210.8
- 30 Sep 2013
Link, out of alignment
LT FLOOR MOUNTED ESCAPE SLIDE DEPLOYMENT LINK OUT OF ALIGNMENT. ADDED SHIMS TO ALIGN SLIDE DEPLOYMENT LINK WITH SLIDE DEPLOYMENT HOOK IAW AMM 25-68-01. OPS…
- 3 Sep 2013
Battery Pack, no test
RT UPPER DECK ESCAPE DOOR BATTERY WILL NOT TEST. R & R RT UPPER DECK ESCAPE DOOR BATTERY IAW BMM CHAPTER 52-23-14. OPERATIONS CHECKS GOOD.
- 15 May 2013
Display, failed
FUMES, HEAVY IN SCENT, IN COCKPIT DURING DESCENT, AFTER FIRST OFFICER'S PRIMARY FLIGHT DISPLAY FAILURE. PERFORMED FUMES IN CABIN CONDITIONAL INSPECTION IAW MM…
- 29 May 2012
Display, failed
AFTER TAKEOFF PRIMARY EICAS (UPPER DISPLAY) FAIL WITHOUT AUTO SWITCHING TO LOWER POSITION. F/O PFD DISPLAY COLOR GUN FAIL DID NOT GO TO GRAY SCALE, DISPLAY…
- 17 Feb 2012
Rib, cracked
LEFT WING L/E NOSE BEAM LOWER RIB IS CRACKED AT ILES 1120.
- 9 Feb 2012
Door Frame, worn
AFT OF APU DOORS LOWER STRUCTURE AT 6 O'CLOCK POSITION STA 2742 HAS SIGNS OF WEAR.
- 8 Feb 2012
Skin, damaged
THERE IS A SMALL AREA OF WEAR DAMAGE THAT EXCEEDS SRM LIMITS AT STA 2360 TO 2364 ON THE FUSELAGE SKIN AT THE VERTICAL STAB SEAL INTERFACE LT SIDE.
- 8 Feb 2012
Web, damaged
UPPER RUDDER LOWER WEB IS DAMAGED.
- 8 Feb 2012
Stiffener, cracked
UPPER RUDDER LOWER WEB HAS A CRACKED STIFFENER.
- 4 Feb 2012
Stringer, cracked
CRACK ON STR 10L AT STA 2430 IN JACKSCREW COMPARTMENT.
- 4 Feb 2012
Light, failed
UPPER DECK STA 560 - 580 CEILING EMERGENCY LIGHT FAILED TEST LIGHT WENT OUT AFTER 5 MINUTES.
- 17 Feb 2011
Light, inoperative
COCKPIT EMERGENCY LIGHT INOP.
- 17 Feb 2011
Light, inoperative
EMERGENCY LIGHT IN STAIR WELL TO UPPER DECK IS INOP.
- 17 Feb 2011
Light, inoperative
EMERGENCY LIGHT IN FORWARD SECTION OF UPPER DECK IS INOP.
- 17 Feb 2011
Battery Pack, failed
UPPER DECK LT DOOR EMERGENCY OPENING SYSTEM FAILED BATTERY PACK CHECK.
- 17 Jul 2010
Skin, damaged
EXTERNAL FUSELAGE SKIN IS DAMAGED AT BS 150 BETWEEN STR 42AR AND 45R.
- 17 Jul 2010
Skin, damaged
EXTERNAL FUSELAGE SKIN IS DAMAGED AT BS 190 BETWEEN STR 42AR AND 43R.
- 17 Jul 2010
Skin, damaged
EXTERNAL FUSELAGE SKIN IS DAMAGED AT BS 210 BETWEEN STR 43R AND 45R.
- 17 Jul 2010
Skin, damaged
EXTERNAL FUSELAGE SKIN IS DAMAGED AT BS 215 BETWEEN STR 42AR AND 43R.
- 9 Jan 2010
Strap, cracked
FUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, LBL 10.
- 9 Jan 2010
Strap, cracked
FUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, LBL 20.
- 9 Jan 2010
Strap, cracked
FUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, RBL 10.
- 9 Jan 2010
Strap, cracked
FUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, RBL 20.
- 3 Sep 2009
Light, inoperative
COCKPIT EMERGENCY LIGHTS OUT IN COCKPIT. RELAMPED COCKPIT EMERGENCY LIGHT PER B747 M/M 33-51-07. OPS NORMAL.