- 8 Oct 2026
Fire Warning, false activation
CARGO FIRE AFT. CORRECTIVE ACTION: NO SIGNS FIRE NOTED AND SUSPECTED ISSUE WAS DRY ICE CARRIED IAW CONDITIONAL INSPECTION B747 AMM 05-51-56, FIM 21-00 TASK…
- 30 Sep 2026
Door, damaged
GEAR DOOR EICAS. INSP & TROUBLESHOT IAW AMM 05-41-07, FIM 32-61, & AMM 32-61-00. DAMAGED LT BLG INBD DOOR & HARDWARE. ALL CHKD GOOD IAW AMM 32-61-00. NO…
- 27 May 2026
Web, corroded
CORROSION FOUND ON FORWARD CARGO TORQUE BOX AT STA 660 APPROX
- 12 Dec 2025
Intercostal, cracked
A CRACK INDICATION WAS IDENTIFIED BETWEEN FASTENERS AT BL 0 BETWEEN STA 320 AND STA 340
- 12 Dec 2025
Tension Tie, cracked
AFTER NDT INSPECTION FOUND TWO CRACKS ON TWO FASTENER HOLES AT TENSION TIE 1120 LT SIDE.
- 12 Dec 2025
Seat Track, corroded
DURING " OK TO INSTALL " FOUND SEAT TRACK AT FUSELAGE STA 1960 RBL 11.33 WITH EXFOLIATION CORROSION AT THE LOWER SURFACE FLANGE
- 12 Dec 2025
Tension Tie, cracked
AFTER NDT INSPECTION 3 EA FASTENER HOLES FOUND WITH DEFECT INDICATION ON TENSION TIE BS 1140 LT.
- 12 Dec 2025
Tension Tie, cracked
AFTER NDT ACCOMPLISHED A HFEC OPEN INSPECTION ON TENSION TIE STA 1180 L/H SIDE FOUND 3 EA FASTENER HOLE WITH DEFECT INDICATION
- 12 Dec 2025
Web, cracked
AFTER NDT INSPECTION A DEFECT NOTED ON HOLE AT BONDED WEB ASSEMBLY STA 2598 WL 265 AND RBL 39
- 10 Dec 2025
Fuel Tank, corroded
CORROSION FOUND ON FUEL CTR TANK BETWEEN UPPER SKIN EDGE AND CANTED AREA MAIN DECK STA 1241, BL 0, NWL 175
- 9 Dec 2025
Reservoir, discharged
EMERGENCY POWER RESEVOIR DISCHARGED (LH)
- 9 Dec 2025
Skin, corroded
CORROSION FOUND ON FUEL CTR TANK ON UPPER SKIN MAIN W/W UPPER SURFACE MAIN DECK STA 1241 LBL 2
- 9 Dec 2025
Power Supply, inoperative
EMERGENCY LIGHTS L5734 STA 498, L1382 STA 360, L5604 STA 470 WONT TURN ON.
- 5 Dec 2025
Web, cracked
SEVERAL CRACKED PANELS IN AREA INSIDE OF THE FUSELAGE FWD OF NOSE GEAR WELL STA 140-180 L/H AND R/H LOCATIONS. 4 EA. WEBS
- 5 Dec 2025
Plate, cracked
AFTER TENSION TIE NDT INSPECTION FOUND 7 EA FASTENER HOLES WITH CRACK INDICATIONS ON STEEL PLATE BS 1180 LT.
- 5 Dec 2025
Plate, cracked
AFTER TENSION TIE NDT INSPECTION FOUND 7 EA FASTENER HOLES WITH CRACK INDICATION ON STEEL PLATE BS 1220 RT.
- 5 Dec 2025
Plate, cracked
AFTER TENSION TIE NDT INSPECTION FOUND 8 EA FASTENER HOLES WITH CRACK INDICATION ON STEEL PLATE BS 1140 RT.
- 5 Dec 2025
Tension Tie, cracked
AFTER TENSION TIE NDT INSPECTION FOUND 7 EA FASTENER HOLES WITH CRACK INDICATION ON STEEL PLATE STA 1180 R/H
- 5 Dec 2025
Longeron Fitting, cracked
AFTER NDT INSPECTION PER W/O 740037417 EO 5313-23-02 FOUND 1 EA FASTENER HOLE WITH CRACK INDICATION ON STA 2598 STR 11 LONGERON L/H SIDE UPPER FITTING
- 26 Apr 2025
Bulb, inoperative
MULTIPLE EMERGENCY LIGHTS ARE INOP ON UPPER DECK
- 24 Jan 2025
Light, no test
MULTIPLE UPPER DECK EMERGENCY LIGHTS TURN OFF AFTER 3 SECONDS OF OPERATION.
- 9 Nov 2024
Light, inoperative
U/D L/H EMERGENCY DOOR EMERGENCY LIGHTS INOP
- 24 May 2024
Smoke Detector, faulted
ON FINAL FOR 8R, AIRCRAFT LOWER CARGO FIRE WARNING ANNUNCIATED. FOLLOWED QRH AND DISCHARGED FIRE BOTTLES. PER B747-400 AMM 05-51-95 CONDITIONAL INSPECTION…
- 14 Nov 2023
Battery, inoperative
PERFORMED EMERGENCY POWER RESERVOIR CHECK OPS CHECK FAILED R/H UPPER DOOR BATTERY INOP
- 27 Sep 2023
Snubber, failed
L1 DOOR DIFFICULT TO OPEN AND CLOSE. FOUND ROTARY SNUBBER TO BE BAD, REMOVED AND REPLACED ROTARY SNUBBER IAW 747-400 AMM 52-11-10, OPERATIONS CHECKS NORMAL.
- 15 Sep 2023
Battery, inoperative
LH UPPER DECK EMERGENCY ESCAPE DOOR BATTERY IS DEAD
- 14 Sep 2023
Angle, cracked
AFT LOWER L-ANGLE CRACKED AT STA 440, STR 26 FWD SIDE OF R1 DOOR OPENING.
- 14 Sep 2023
Attach Angle, cracked
#3 PYLON I/B SKIRT FAIRING ATTACH ANGLE HAS POSSIBLE CRACK
- 14 Sep 2023
Bulkhead, cracked
CRACK FOUND STA 2598 R/H SIDE IN INNER CHORD ADJACENT TO LOWEST INBOARD FASTENER HOLE AT INTERIM REPAIR
- 14 Sep 2023
Stiffener, cracked
TOP STIFFENER CRACKED @ STATION 300 L/H SIDE AS MARKED
- 14 Sep 2023
Bulkhead, cracked
STA 2598 BLKHD R/H FWD INNER CHORD CRACKED AT 1 EA. LOCATION
- 14 Sep 2023
Support Fitting, corroded
LH OB ELEVATOR REACTION HINGE SUPPORT FITTING IS CORRODED.
- 14 Sep 2023
Seat Track, corroded
POSSIBLE CORROSION ON SEAT TRACK AT STA 1670 RBL 12.
- 26 Jun 2023
Bottle, low pressure
L/H UPPER DECK ESCAPE SLIDE AFT BOTTLE LOW AFTER SERVICING.
- 31 Jan 2023
Cover, damaged
COVER HAS FALLEN OFF AND SHATTERED FROM FLIGHT DECK EMERGENCY ACCESS LIGHT AIRCRAFT OF P7. REMOVED AND REPLACED SHATTERED COVER ASSEMBLY IN ACCORDANCE WITH…
- 21 Nov 2022
Light, inoperative
MULTIPLE EMERGENCY LIGHTS INOP
- 27 Jun 2022
Light, inoperative
L/H UPPER DECK DOOR EMERGENCY LIGHTS INOP
- 27 Jun 2022
Light, inoperative
R/H UPPER DECK DOOR EMERGENCY LIGHTS INOP
- 6 Jan 2022
Light, inoperative
RH UPPER DECK EMERGENCY ESCAPE DOOR EMERGENCY LIGHTS INOP
- 30 Jul 2021
Support Bracket, corroded
RIGHT HAND ELEVATOR INBOARD ACTUATOR UPPER HINGE INBOARD SUPPORT BRACKETS HAS EVIDENCE OF CORROSION
- 30 Jul 2021
Support Bracket, corroded
RIGHT HAND ELEVATOR INBOARD ACTUATOR UPPER HINGE OUTBOARD SUPPORT BRACKET HAS EVIDENCE OF CORROSION
- 21 Jul 2021
Stiffener, cracked
CRACKED STIFFENER ON NWW STA 310 LBL 10
- 21 Jul 2021
Stiffener, cracked
CRACKED STIFFENER ON NWW STA 310 RBL 10
- 13 Jul 2021
Frame, corroded
FOUND EVIDENCE OF CORROSION ON MAIN DECK UNDER FLOOR BOARD STA 1480 LBL 20
- 30 Jun 2021
Stiffener, cracked
3 EA. CRACK INDICATIONS ON NWW AT STA 310 R/H WL 130, RADIUS OF STIFFENER
- 3 Mar 2021
Light, inoperative
UPPER DECK EMERGENCY LIGHT STA 644 INOP
- 20 May 2020
Light, inoperative
UPPER DECK AFT EMERGENCY LIGHT INOP
- 4 Mar 2020
Light, inoperative
R/H UPPER DECK DOOR EMERGENCY SLIDE LIGHTS INOP L2927 AND L2930
- 4 Mar 2020
Light, inoperative
L/H UPPER DECK DOOR EMERGENCY SLIDE LIGHTS INOP L2927 AND L2930
- 28 Aug 2019
Angle, corroded
LOWER INSIDE ANGLE OF AFT PIT CARGO DOOR HAS CORROSION IN MULTIPLE SPOTS
- 26 Aug 2019
Light, inoperative
EMERGENCY LIGHT IN MAIN DECK CEILING BY L1 DOOR INOP
- 26 Aug 2019
Light, inoperative
EMERGENCY LIGHTS UPPER DECK AFT, CENTER & LEFT INOP
- 14 Aug 2019
Door Sill, corroded
L/H UPPER DECK DOOR SILL OUTER CORD CORRODED.
- 7 Aug 2019
Seat Track, corroded
CORROSION FOUND ON SEAT TRACK AT STA 2223 LBL 89.67.
- 7 Aug 2019
Plate, corroded
CORROSION IN HOLES OF MDCD LATCH PIN FITTING MOUNT PLATES POSITION 8 AND 10.
- 7 Aug 2019
Floorbeam, corroded
EVIDENCE OF CORROSION ON UPPER CHORD OF MAIN DECK FLOOR BEAM AT STA 2360 RBL 53
- 1 Aug 2019
Floorbeam, cracked
BULK PIT FLOORBEAM CRACKED STA 2000 RBL 32
- 1 Aug 2019
Skin, corroded
FWD CARGO COMPT BILGE AT F.S. 980 - 1000, RBL 60 APPROX, HAS EVIDENCE OF CORROSION
- 1 Aug 2019
Seat Track, cracked
FWD PIT SEAT TRACK CRACKED STA 710 LBL 24
- 1 Aug 2019
Skin, cracked
L5 DOOR CUTOUT FWD EDGE CRACKED
- 1 Aug 2019
Web, cracked
UPPER DECK MED LOWER SILL WEB STA 665 - 715 CRACKED
- 1 Aug 2019
Seat Track, corroded
EVIDENCE OF CORROSION ON MAIN DECK SEAT TRACK STA 1484 RBL 32
- 1 Aug 2019
Stiffener, cracked
BULK PIT FLOOR STA 2000 RBL 40 STIFFENER CRACKED
- 1 Aug 2019
Stiffener, cracked
BULK PIT FLOOR STA 2000 RBL 32 STIFFENER CRACKED
- 17 Jul 2019
Web, cracked
WEB CRACKED AT TIP OF LT HORIZ. STAB. APPROX. STAB BL 421.5 APPROX. 30 INCHES FROM AFT EDGE.
- 17 Jul 2019
Spar, cracked
UPPER CHORD CRACKED AT TIP OF LT HORZ. STAB. APPROX. STAB BL 421.5 APPROX. 30 INCHES FROM AFT EDGE.
- 17 Jul 2019
Spar, cracked
LOWER CHORD CRACKED AT TIP OF LT HORZ. STAB. APPROX. STAB BL 421.5 APPROX. 30 INCHES FROM AFT EDGE.
- 17 Jul 2019
Spar, cracked
UPPER CHORD CRACKED AT TIP OF RT HORIZ. STAB. APPROX. STAB BL 421.5 APPROX. 30 INCHES FROM AFT EDGE.
- 17 Jul 2019
Web, cracked
WEB CRACKED AT TIP OF RT HORIZ. STAB. APPROX. STAB BL 421.5 AT AFT SPAR WEB.
- 16 Jul 2019
Stringer, corroded
AFT PIT STR 51 L HAS EVIDENCE OF CORROSION AT STA 1480.
- 16 Jul 2019
Torque Box, corroded
EVIDENCE OF CORROSION ON AFT PIT TORQUE BOX WEB STA 1680 RBL 8.
- 10 Jul 2019
Stringer, corroded
AFT PIT STR 51R HAS EVIDENCE OF CORROSION STA 1480.
- 10 Jul 2019
Seat Track, cracked
AFT PIT SEAT TRACK CRACKED STA 1840 RBL 25.
- 1 Jul 2019
Reveal, cracked
BS 2231 RT DOOR REVEAL CRACKED BETWEEN STR 21 R & 22 R.
- 26 Jun 2019
Fuse Pin, cracked
LEFT WLG SUPPORT BEAM FUSE PIN CRACKED AT 2 GREASE HOLES, TOTAL 4 EACH CRACKS, EACH APPROX 0.150" L
- 26 Jun 2019
Stringer, corroded
AFT PIT STRINGER 51 R END FITTING HAS EVIDENCE OF CORROSION AT STA 1480
- 26 Jun 2019
Stringer, corroded
AFT PIT STRINGER 51 L END FITTING HAS EVIDENCE OF CORROSION AT STA 1480
- 26 Jun 2019
Angle, cracked
ANGLE CRACKED INSIDE AFT PIT CARGO DOOR JUST ABOVE FWD OPENING ROD ATTACH FITTING
- 26 Jun 2019
Stiffener, cracked
NOSE WHEEL WELL SIDEWALL PANEL STIFFENER CRACKED. B.S. 290 RBL 30 WL 170 CRACK LENGTH 14"
- 26 Jun 2019
Stiffener, cracked
NOSE WHEEL WELL SIDEWALL PANEL STIFFENER CRACKED. B.S. 328 RBL 30 WL 130 CRACK LENGTH 1"
- 26 Jun 2019
Fuse Pin, cracked
R/H WLG SUPPORT BEAM FUSE PIN CRACKED AT GREASE HOLE
- 26 Jun 2019
Frame, cracked
BS 2231 L STR 22 FWD 1 EA HOLE CRACKED COMMON TO THE INBD CHORD.
- 26 Jun 2019
Frame, cracked
STA 2231 L STR 21 1 EA HOLE FWD & AFT CRACKED COMMON TO THE INNER CORD
- 26 Jun 2019
Frame, cracked
STA 2231 L STR 20 AFT 1 EA HOLE CRACKED COMMON TO THE INBD CORD
- 26 Jun 2019
Frame, cracked
STA 2231 L STR 18 2 EA HOLES CRACKED COMMON TO THE INBD CORD
- 26 Jun 2019
Frame, cracked
STA 2231 L STR 19 1 EA HOLE CRACKED THRU SKIN COMMON TO THE INBD CORD
- 26 Jun 2019
Frame, cracked
STA 2231 L STR 17 1 EA HOLE CRACKED AFT COMMON TO THE INBD CORD
- 31 May 2018
Support Fitting, damaged
NR 7 SPOILER WEB DAMAGED. THE WEB IS PART OF NR 7 SPOILER ACTUATOR SUPPORT FITTING.
- 20 Oct 2017
Light, inoperative
UPPER DECK EMERGENCY LIGHTS INOPERATIVE.
- 22 Aug 2017
Battery, inoperative
LT UPPER DECK DOOR EMERGENCY POWER BATTERY IS INOP.
- 27 Jul 2017
Skin, corroded
SKIN AT BS 1758, STRINGER 45R FOUND CORRODED AND CRACKED.
- 27 Jul 2017
Stringer, corroded
STRINGER 45R AT BS 1758 HAS EVIDENCE OF CORROSION.
- 27 Jul 2017
Skin, damaged
FUSELAGE SKIN AT BA 1941, STRINGER 46R EVIDENCE OF PULLED FASTENER.
- 20 Jul 2017
Skin, cracked
FUSELAGE SKIN HAS A CRACK AT FASTENER APPROX BS 540, STRINGER 23L.
- 26 Aug 2015
Bear Strap, cracked
RIGHT MAIN ENTRY DOOR NR 5 UPPER AFT DOOR FRAME CORNER CUTOUT INNER LAYER, BEARSTRAP, CRACKED .250" LONG.
- 14 Aug 2015
Frame, corroded
CORROSION ON FRAME, ZONE 151, BS 2200, JUST IN FRONT OF OUTFLOW VALVE. GROUNDING STRAP BOLT TO FRAME.
- 14 Aug 2015
Stringer, corroded
CORROSION ON STRINGER, INBD OF OUTFLOW VALVE.
- 14 Aug 2015
Stringer, corroded
BS 2203.0 LT STRINGER 44, CORROSION ON OTBD WEB OF STRINGER.
- 14 Aug 2015
Bear Strap, cracked
L3 DOOR UPPER AFT CORNER BEARSTRAP HAS A CRACK.
- 30 Jul 2015
Stringer, cracked
NR 3 PYLON, OTBD SIDE AT NAC BS 375, 1ST STRINGER UP FROM BOTTOM SPAR IS CRACKED.
- 2 Jun 2015
Engine, vibration
AFTER ROTATION, CREW NOTICED A VIBRATION. NR 3 ENGINE VIBRATION INDICATOR DISPLAYED HIGH. ALL OTHER ENGINE INDICATIONS WERE NORMAL. VIBRATION DISAPPEARED…
- 29 Nov 2014
Light, inoperative
UPPER DECK EMERGENCY LIGHT AT BS 640 INOPERATIVE.
- 8 Oct 2013
Battery Pack, failed
ON TERMINATING SERVICE CHECK, LT ESCAPE DOOR BATTERY CHECK FAILED. R & R BATTERY PACK IAW MM 52-23-14. OPS CHECKED GOOD.
- 11 Sep 2013
Fire Warning, false activation
FIRE WARNING IN FWD CARGO, DECLARED EMERGENCY, DISCHARGED FIRE EXTINGUSHING BOTTLES. INSPECTED LOWER CARGO BAY FOR FIRE, NONE NOTED. R & R LOWER CARGO BAY…
- 23 Aug 2013
Floorbeam, corroded
BS 1920 FLOORBEAM UPPER TEE FWD SIDE LOWER LEG AT RBL 40 IS CORRODED.
- 23 Aug 2013
Light, inoperative
EMERGENCY LIGHT AND EXIT SIGNS AT BS 620, 640 & 690 WILL NOT ILLUMINATE.
- 23 Aug 2013
Light, inoperative
EMERGENCY LIGHT AT L1 DOOR INOPERATIVE.
- 16 Aug 2013
Frame, damaged
FORWARD CARGO BAY HAS A FRAME FLANGE DAMAGED AT BS 500 BETWEEN S37-38L.
- 13 Aug 2013
Frame, corroded
CORROSION FOUND AT BS 1920, RBL 55 ON AFT CHORD LWR LEG OF INNER FRAME.
- 9 Aug 2013
Skin, damaged
IN APU COMPARTMENT, TAILCONE CUT OUT DAMAGED AT BS 2742, BL 0 WHERE APU DOORS MEET.
- 9 Aug 2013
Skin, cracked
NR 1 PYLON RT ACCESS DOOR CUT OUT, SKIN CRACKED AT AFT LOWER CORNER NAC. STA. 295.
- 8 Aug 2013
Pressure Deck, corroded
CORROSION ON TOP OF MAIN WHEEL WELL PRESSURE DECK AT BS 1440, LBL 46.
- 8 Aug 2013
Pressure Deck, corroded
CORROSION ON TOP OF MAIN WHEEL WELL PRESSURE DECK AT BS 1440, LBL 46.
- 8 Jun 2013
Circuit Board, intermittent
HAD AN ENROUTE MAIN DECK MID FIRE WARNING (INTERMITTENT/ MOMENTARY). INSPECTION CONFIRMED NO FIRE/ SMOKE. PERFORMED FIM TASK 26-16-911. R & R THE A7 CARD IAW…
- 3 Jan 2013
Skin, corroded
FUSELAGE SKIN CORRODED AT BS 1740, WL 96, RBL 30, STR 46R.
- 1 Jan 2013
Skin, corroded
POSSIBLE CORROSION ON EXTERNAL SKIN AT STA 1740, WL 96, RBL 30.
- 6 Jun 2012
Battery Pack, discharged
RIGHT EMERGENCY DOOR BATTERY WILL NOT TEST. REMOVED AND REPLACED RIGHT UPPER DECK DOOR EMERGENCY BATTERY PACK IAW MM 52-23-14. OPS CHECK NORMAL.
- 19 Jul 2011
Stiffener, cracked
RIGHT I/B ELEVATOR FRONT SPAR STIFFENER CRACKED AT ELEV STA 106.8.
- 19 Jul 2011
Stiffener, cracked
RIGHT I/B ELEVATOR FRONT SPAR STIFFENER CRACKED AT ELEV STA 94.7.
- 19 Jul 2011
Flap Track, corroded
NR 7 FLAP TRACK HAS RUST UNDER BUSHING PLATE WHERE IT ATTACHES TO REAR SPAR.
- 19 Jul 2011
Flap Track, corroded
NR 3 FLAP TRACK HAS RUST UNDER BUSHING PLATE WHERE IT ATTACHES TO REAR SPAR.
- 19 Jul 2011
Flap Track, corroded
NR 6 FLAP TRACK HAS RUST UNDER BUSHING PLATE WHERE IT ATTACHES TO REAR SPAR.
- 2 Jul 2011
Sign, inoperative
LT UPPER DECK EMERGENCY DOOR, UPPER EXIT SIGN INOP.
- 2 Jul 2011
Sign, inoperative
RT UPPER DECK EMERGENCY DOOR EXIT SIGNS BOTH INOP.
- 2 Jul 2011
Light, inoperative
APPROX STA 630, UPPER DECK EMERGENCY EXIT LIGHT INOP.
- 2 Jul 2011
Sign, inoperative
APPROX STA 650, UPPER DECK CEILING EMERGENCY EXIT SIGN INOP.
- 26 Jun 2011
Stringer, corroded
STA 2160 - 2180 STR 41R CORROSION THROUGH STRINGER SIDE WEB FLANGE.
- 26 Jun 2011
Web, corroded
STA 2160 - 2180 STR 40R HAS SMALL AREA OF CORROSION ON SIDE WEB FLANGE.
- 26 Jun 2011
Stringer, corroded
STR 42R AT STA 2160 HAS CORROSION ON UPPER SIDE WEB FLANGE OF STRINGER.
- 13 Apr 2011
Engine, leaking
SMOKE IN FLT DECK & CABIN DURING CRUISE. DECLARED EMERGENCY AND DIVERTED TO EDDF. PERFORMED FIM TASK 21-00 TASK 810 & 71-03 TASK 854. FOUND OIL (ENG) IN TAIL…
- 25 Aug 2009
Power Supply, discharged
UPPER DECK EMERGENCY LIGHTS FAIL TO ILLUMINATE. REMOVED AND REPLACED UPPER DECK EMERGENCY LIGHT POWER SUPPLY AS PER B747-400 MM 33-51-04. OPS CHECKS GOOD.
- 9 Jul 2009
Skin, damaged
STATIC DISCHARGE AT BS 350 BETWEEN STR 43L AND 44L.
- 29 Jun 2009
Skin, damaged
STATIC DISCHARGE ON FUSELAGE SKIN AT BS 150, STR-32L.
- 29 Jun 2009
Skin, damaged
STATIC DISCHARGE ON FUSLEAGE SKIN AT BS 430 BETWEEN STR-42L AND 43L.
- 29 Jun 2009
Skin, damaged
STATIC DICHARGE ON FUSELAGE SKIN AT BS 345, STR-44L.
- 29 Jun 2009
Skin, damaged
STATIC DISCHARGE ON FUSELAGE SKIN AT BS 155, STR-32L.
- 29 Jun 2009
Skin, damaged
STATIC DISCHARGE ON FUSELAGE SKIN AT BS 200 ABOVE STR-33L.
- 29 Jun 2009
Skin, damaged
STATIC DISCHARGE ON FUSELAGE SKIN AT BS 180 BELOW STR-33L.
- 29 Jun 2009
Skin, damaged
STATIC DISCHARGE ON FUSELAGE SKIN AT BS 220 ABOVE STR-33L.
- 26 Jun 2009
Skin, damaged
STATIC DISCHARGE AT STA-164, STR-32L.
- 26 Jun 2009
Skin, damaged
STATIC DISCHARGE AT STA-480, STR-42L.
- 26 Jun 2009
Skin, damaged
STATIC DISCHARGE AT STA-400, STR-43L.
- 26 Jun 2009
Skin, damaged
STATIC DISCHARGE AT STA-375, STR-43L.
- 26 Jun 2009
Skin, damaged
STATIC DISCHARGE AT STA-365, STR-43L.
- 26 Jun 2009
Skin, damaged
STATIC DISCHARGE AT STA-360, STR-43L.
- 28 Mar 2009
Light, inoperative
L1 EMERGENCY EXIT LIGHT IS INOP.