N74
Penns Cave, airport
Russell E. Schleiden
Centre Hall PA full record →
- N74
Penns Cave, airport
P.C. Avn Svc, INC.
Centre Hall PA full record →
- N74
Penns Cave, airport
aircraft
Douglas DC3C-S1C3G FAA →
reservations
earlier registrations
service difficulty reports
11 reports
- 8 Apr 2014
Display, inoperative
DISPLAY FAILED, CABIN HAD SMOKE PRESENT WITH STRONG ELECRICAL ODOR. A DETAILED SMOKE & FUMES INSPECTION WAS PERFORMED. DISPLAY HAD A STRONG ELECRICAL ODOR.…
- 4 Feb 2012
Fuel Cap, unsecure
AFTER REACHING FL200, FUEL STREAMING FROM LEFT OUTBOARD FUEL CAP WAS OBSERVED BY CREW. EMERGENCY WAS DECLARED AND AN UNEVENTFUL LANDING WAS MADE.
- 24 Jan 2012
Hose, restricted
DURING FLIGHT INSPECTION MISSION, LOST GPS UPDATING (HONEYWELL) AND SHORTLY THEREAFTER NOTICED A BURNING ELECTRICAL SMELL. ALL THREE CREW NOTICED THE SMELL.…
- 12 Jan 2010
Tube, broken
ON GROUND WHEN ENGINES STARTED (WITH BLEEDS IN ENVIRONMENTAL) STRONG EXHAUST SMELL IN CABIN. SMELL GOES AWAY ONCE AIRCRAFT PRESSURIZES. WHEN AIRCRAFT STARTED…
- 15 Feb 2007
Squat Switch, defective
LANDING GEAR HANDLE CANNOT BE RAISED INFLIGHT WITHOUT USING DOWNLOCK RELEASE. REPLACED SWITCH ON RT MAIN SCISSORS.
- 27 Jul 2005
Transducer, failed
RT ENGINE OIL PRESSURE INDICATION WAS ABOVE 200 PSI. CREW NOTICED SLIGHT OIL SMELL IN AC. PRECAUTIONARY SHUTDOWN OF RT ENGINE IN FLIGHT. ALL OTHER INDICATIONS…
- 23 May 2003
Hook, failed
J-HOOK OVER LANDING GEAR SELECTOR HANDLE IN COCKPIT RETRACTED WITH AIRCRAFT ON GROUND. LUBRICATED AND ACTUATED (J) HOOK AND RIGGED RIGHT MAIN LANDING GEAR…
- 7 Apr 2003
Wire, melted
CLIMBING THROUGH16,500 FT MSL, LT BLEED AIR LIGHT FLASHED THEN STEADY. FOLLOWED EMERGENCY PROCEDURE AND LANDED. DURING DESCENT, BLEED AIR FAIL LIGHT…
- 26 Sep 2002
Powerpack, malfunctioned
PUT GEAR HANDLE DOWN, NOTHING HAPPENED, NO LIGHTS, NO LANDING GEAR EXTENDED. EXECUTED MANUAL EXTENSION PROCEDURE, THREE GREEN LIGHTS, NO RED, LANDED…
- 27 Jun 2002
Relay, burned
WHITE SMOKE FILLED CABIN FROM BACK. OBSERVER SAID IT WAS NOT COMING FROM EQUIPMENT RACKS. SMELLED LIKE BURNING WOOD OR PAPER . FIRE DEPARTMENT FOUND NO…
- 3 Aug 1999
Blower, failed
THE FLT CREW NOTICED A BURNING ODOR/FUMES AT CRUISE ALTITUDE. NO VISIBLE SMOKE WAS NOTED. DURING THIS TIME THE PANEL TECH NOTICED THAT THE TEMPERATURE IN THE…