- 22 Apr 2001
Battery Pack, discharged
BOTH LT ESCAPE HATCH EMERGENCY EXIT SIGNS ARE INOPERABLE. *S/D* BATTERY PACK FAILED. REPLACED BATTERY PACK. OPERATIONS CHECK NORMAL.
- 14 Jan 2001
Sensor, failed
UNABLE TO RETRACT LANDING GEAR NORMALLY ON TAKEOFF. *S/D* REPLACED AIR SAFETY SENSOR AND ADJUSTED SHIM PER MAINTENANCE MANUAL. ACCOMPLISHED…
- 29 Oct 2000
Pump, failed
DIVERTED TO IAD DUE TO LOSS OF A-SYSTEM HYDRAULICS. REPLACED NR 1 ENGINE HYDRAULIC PUMP.
- 20 Jul 1998
Control Panel, failed
FLIGHT ATTENDANT NOTICED SMOKE AND SPARKS COMING FROM THE ELECTRICAL CONTROL PANEL ON THE FORWARD GALLEY ABOVE THE HOT PLATE.
- 17 Jun 1998
Transmitter, malfunctioned
NR 3 ENGINE OIL PRESSURE LOW TO RED BAND ON TAKEOFF ROLL. ABORTED TAKEOFF. *S/D* CLEANED THE ELECTRICAL CONNECTOR TO THE OIL PRESSURE TRANSMITTER AND SWAPPED…
- 2 Aug 1997
Light, inoperative
AFT CARGO PIT DOOR EMERGENCY LIGHT INOPERATIVE. *S/D* FOUND ONE LAMP BROKEN AND ONE LAMP WITH CORRODED CONTACT. BOTH LAMPS REPLACED.
- 12 May 1997
Window, cracked
FIRST OFFICER'S SLIDING WINDOW HAS A LONG CRACK DIAGONALLY ACROSS IT. *S/D* REPLACED WINDOW DUE TO OUTER PANE CRACKED.
- 19 Nov 1996
Turbine Wheel, cracked
LOUVER ASSEMBLY AND EXHAUST DUCTS DAMAGED WHEN TURBINE BROKE OFF FROM THE APU. *S/D* UNITED NO LONGER USES (P/N 3606982-1) AND NOW USES(P/N 3842072-2 OR - 3).…
- 18 Oct 1996
Battery Pack, discharged
EEL STRIP INOP FROM ROW 26 AFT APPROXIMATELY 12 FEET. REPLACED POWER CONDUIT TO AFT STRIP SECTIONS AND BATTERY PACK, OPS CHECK NORMAL.
- 27 Sep 1996
Fuel Transfer, malfunctioned
UNWANTED FUEL TRANSFER FROM NR 1 TO NR 2 TANK. NR 3 TANK WAS 700 POUNDS HIGHER THAN NR 1.
- 29 Aug 1996
Elbow, cracked
UNWANTED FUEL USAGE FROM NR 1 TANK DURING TAKEOFF. DECREASE 1,000 LBS. *S/D* FUEL VENT TUBE ELBOW CRACKED. REPLACED ELBOW.
- 5 Jun 1996
Oven, burnt odor
CREW REPORTED, AFT GALLEY AREA HAS A BURNT SMELL. *S/D* OPERATED COFFEE MAKERS, NO DISCREPANCY OR SMELL NOTED. GALLEY MODULES REMOVED AT LAS. REPLACEMENT OVEN…
- 5 Mar 1996
Fan, failed
ELECTRICAL FUMES NOTICED IN CENTER OF CABIN, COULD NOT ISOLATE CAUSE. FOUND GASPER FAN POPPING CIRCUIT BREAKER. REPLACED GASPER FAN. OPERATIONALLY CHECKED…
- 15 Feb 1996
Light, inoperative
EEL DOOR FRAME LIGHT INOPERATIVE DOOR 1 LEFT. REPLACED FEEDER.
- 13 Sep 1995
Eel Battery Pack, discharged
EMERGENCY LIGHT ABOVE AFT END OF VENTRAL STAIRS INOPERATIVE. REPLACED BATTERIES.