N7288U
1979 Boeing 727-222 standard FAA →
reservations
earlier registrations
1 past record
- 1979
service difficulty reports
19 reports
- 26 Sep 2001
Lamp, failed
EMERGENCY EXIT LIGHTING IN FIRST CLASS AISLE IS INOPERABLE. *S/D* LAMPS FAILED. REPLACED LAMPS. OPERATIONS CHECK NORMAL.
- 4 Mar 2001
Adc, failed
DURING CRUISE THE CAPTAINS ALTIMETER AND AUTOPILOT WERE INOPERABLE. SUPPLEMENTAL DATA UPDATE MAINTENANCE REPLACED CAPTS AIR DATA COMPUTER - OPS CHECK NORMAL…
- 21 Feb 2001
Skin, damaged
STATIC DISCHARGE FOUND AT RT ELEVATOR TRAILING EDGE JUST OUTBOARD OF TAB. INSTALLED SKIN REPAIR PER CMM SM-70-55-20-03-JD FIG 19.
- 21 Feb 2001
Skin, delaminated
RIGHT INBOARD FLAP IS DELAMINATED AND LEFT INBOARD FORE FLAP UPPER SURFACE IS CHAFED. REMOVED AND REPLACED RIGHT INBOARD FLAP PER MM 27-51-04. REPAIRED LEFT…
- 21 Feb 2001
Skin, delaminated
LEFT ELEVATOR TAB IS DELAMINATED. REPAIRED TAB PER GN MM 1-0-1-24 AND CALCULATED WEIGHT AND BALANCE PER SRM 51-80-09.
- 11 Jun 2000
Power Supply, failed
DOOR 2L EMERGENCY EXIT LIGHT INOPERATIVE. *S/D* REPLACED BATTERY AND CHARGER IN AFT GALLEY CEILING.
- 1 Jan 2000
Bypass Valve, leaking
HYDRAULIC SYSTEM A PRESSURE AND QUANTITY ZERO. ENGINES 1 AND 3 PUMPS LIGHTS ON APPROXIMATELY 5 MINUTES AFTER ELEVATOR FEEL DIFFERENTIAL PRESSURE LIGHT ON.…
- 7 Apr 1999
Emergency Lights, miswired
THE EMERGENCY LIGHTS UNDER THE GLARE SHIELD ARE ON. LIGHTS ARE TIED INTO THE PILOTS BACKGROUND LIGHTS. RELAMPED BACKGROUND LIGHTS AND CORRECTED EMERGENCY…
- 22 Oct 1998
Light, inop
FORWARD CABIN CEILING EMERGENCY LIGHT INOPERATIVE.
- 20 Oct 1998
Light, inop
FORWARD CABIN CEILING EMERGENCY LIGHT INOPERATIVE.
- 12 Aug 1998
Battery, discharged
AIRSTAIR EMERGENCY LIGHT INOPERATIVE. *S/D* REPLACED BATTERY, OPERATIONAL CHECK OK.
- 22 Jul 1998
Battery, discharged
EMERGENCY EXIT SIGN ABOVE DOOR 1L DIM AND THEN FADES OUT. *S/D* REMOVED AND REPLACED BATTERIES.
- 20 Jul 1998
Battery, discharged
FORWARD COACH CEILING EMERGENCY LIGHT INOPERATIVE. *S/D* REPLACED BATTERY.
- 26 Jun 1998
Pressurization, malfunctioned
CABIN PRESSURE CANNOT BE MAINTAINED.
- 5 May 1998
Skin, cracked
APPROXIMATELY THREE INCH CRACK IN FUSELAGE SKIN AT LOWER AFT RADIUS OF DOOR 1R FRAME.
- 25 Jan 1998
Battery, discharged
CEILING EMERGENCY EXIT SIGN BETWEEN FORWARD DOORS IS INOPERATIVE. *S/D* REPLACED FAILED BATTERY.
- 30 Apr 1997
Air Distribution, smoke
FORWARD PART OF PASSENGER CABIN FILLED WITH SMOKE. THE SMOKE APPEARED WHEN THE LEFT PACK WAS RUNNING ON THE NR 2 ENGINE BLEED. SUPPLEMENTAL DATA UPDATE,…
- 9 Aug 1996
Light, inoperative
EMERGENCY EXIT LIGHT IN COCKPIT INOPERATIVE.
- 10 Oct 1995
Oil Filter, dirty
OIL FILTER BYPASS LIGHT NR 2 CAME ON. OIL PRESSURE NORMAL 45-47 PSI. LIGHT WENT OUT AS THROTTLE REDUCED, BUT CAME BACK ON AT THE NEW SETTING. STAYED ON AT…