- 1978
service difficulty reports
21 reports
- 20 Jul 2001
Cowling, cracked
NR 2 ENGINE LOWER FORWARD COWLING MATING FLANGE, FOUND 3 CRACKS, ONE 8 INCHES LONG, THE OTHERS 3.5 INCHES LONG. ALSO, THERE IS A HOLE WORN THRU COWL MATING…
- 27 Jun 2001
Battery, missing
THE R1DOOR EMERGENCY EXIT EXTERIOR LIGHT IS INOPERABLE. BATTERY ASSY IS MISSING. INSTALLED MISSING BATTERY ASSY. OPERATIONS CHECK NORMAL.
- 3 Mar 2001
Wire, broken
EMERGENCY EXIT SIGN IS LOOSE AND EEL LIGHTING IS INOPERABLE. SUPPLEMENTAL DATA UPDATE ACCOMPLISHED CABLE ASSEMBLY INTERIM REPAIR PER MM 33-50-32. OPERATIONS…
- 13 Sep 2000
Lead, failed
EEL STRIP BLINKING AT SEAT 27. *S/D* REPLACED POWER LEAD CABLE DUE TO ARCING AT STRIP CONNECTION.
- 5 Feb 2000
Shutoff Valve, stuck
UNABLE TO CONTROL CABIN PRESSURE ON CLIMBOUT OF DEN. RETURNED TO DEN. CORRECTED THE AIRCRAFT FROM 7762 TO 7763. *S/D* ENG 3 BLEED SHUT OFF VALVE STICKING.…
- 4 Jan 2000
Elbow, cracked
WITH FUEL PANEL CONFIGURED TO BURN OUT OF NR 2 TANK ONLY, 900 POUNDS OF FUEL WERE USED FROM TANK NR 3. ALL X-FEEDS WERE OPEN AND FORWARD PUMPS WERE OFF IN…
- 21 Oct 1999
Wire, broken
EEL LIGHTING INOPERATIVE FROM ROWS 19 TO 26. *S/D* REPAIRED BROKEN WIRE TO BATTERY PACK AT SEAT 20, OPERATIONALLY CHECKED NORMAL.
- 30 Jun 1999
Controller, malfunctioned
OVER BVL, AIRCRAFT LOST CABIN PRESSURE. CABIN ALTITUDE CLIMBED ABOUT I000 FEET PER MINUTE TO FL 140. DESCENDED TO FL 140. FLIGHT DIVERTED TO SLC. *S/D*…
- 5 Oct 1998
Wire, broken
FORWARD ENTRY DOOR LOWER EMERGENCY EXIT SIGN INOP. REPLACED EEL CABLE, OPS CHECKS OK.
- 6 Aug 1997
Filler Cap, loose
NR 3 ENGINE OIL QUANTITY STARTED AT 3 GALLONS, ON TAKEOFF IT WENT DOWN TO 2.5. APPROXIMATELY 1 HOUR INTO THE FLIGHT THE QUANTITY WAS DOWN TO I.75 GALLONS.…
- 28 Mar 1997
Light, inoperative
EMERGENCY EXIT LIGHTING INOPERABLE FROM ROW 20 AFT. REPLACED INOP EMERGENCY EXIT LIGHTING. OPERATION CHECKS NORMAL.
- 1 Nov 1996
Fuel Contl Unit, malfunctioned
NR 1 ENGINE NOISY AND VIBRATION ON TAKEOFF. *S/D* LOW FREQUENCY VIBRATION CAUSED THE NOISE AND VIBRATION. THE FUEL CONTROL UNIT WAS REPLACED AND THERE HAS…
- 15 Oct 1996
Inflate Tube, separated
DURING TIME CONTROLLED OVERHAUL, SLIDE SUFFERED SEAM SEPARATION OF THE INFLATION TUBE. SCRAPPED UNIT.
- 21 Sep 1996
Retract Mech, malfunctioned
ON TAXI IN, INBOARD TRAILING EDGE FLAPS DO NOT OPERATE HYDRAULICALLY, STUCK AT 25 DEGREES. FLAPS RETRACTED FROM 30 TO 25 ON LANDING ROLLOUT.
- 25 Jun 1996
Fuel Vent Tube, broken
WHILE CROSS-FEEDING ALL ENGINES FROM NUMBER 2 TANK NUMBER 3 FUEL QUANTITY DECREASED 700 LBS. *S/D* FUEL VENT TUBE ELBOW CRACKED AT FLANGE. REPLACED TUBE…
- 26 Mar 1996
Skin, cracked
AT APPROXIMATELY BODY STATION 943, STRINGER 18AL, A CRACK WAS FOUND IN THE 65-72702 FUSELAGE SKIN PANEL. REPAIRED THE SKIN PANEL PER THE 65C29069-7 REPAIR…
- 21 Mar 1996
Stringer, cracked
AT APPROXIMATELY BODY STATION 943, STRINGER 18AL A CRACK WAS FOUND IN THE VERTICAL FLANGE OF THE 65-58488-25 STRINGER. REPAIRED STRINGER PER SPLICE REPAIR…
- 3 Jan 1996
Battery Pack, discharged
RAMP PERSONNEL NOTICED EXTERIOR EMERG LIGHTS ON INITIALLY AND THEN WENT OUT. FOUND BOTH ENTRY DOORS AND SERVICE DOORS SLIDE LIGHTS INOPERATIVE. USAIR BATTERY…
- 16 Oct 1995
Battery Pack, discharged
FWD GALLEY DOOR EVACUATION SLIDE EXTERIOR EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK.
- 15 Aug 1995
Packing, failed
LANDED LGA UNDER AMBER ALERT DUE TO LOSS OF A-SYSTEM HYDRAULIC. REPLACED ELEVATOR FEEL COMPUTER UNIT FILTER PACKING P/N NAS161216.
- 19 Jun 1995
Eel, inoperative
DOOR 1 LT AND RT EMERGENCY SLIDE LIGHT IS ON WITH EMERGENCY EXIT LIGHT SWITCH IN THE OFF POSITION. REPLACED EMERGENCY SLIDE LIGHT BATTERY AND POWER SUPPLY.