N71GL
1988 Embraer EMB-120ER standard FAA →
reservations
earlier registrations
1 past record
- 1988
service difficulty reports
106 reports
- 22 Sep 2016
Window, lack of lube
PILOT REPORTED THAT THE LEFT COCKPIT WINDOW WAS HARD TO OPERATE. MAINTENANCE CLEANED AND LUBRICATED THE WINDOW IAW MM 12-21-05.
- 3 Aug 2016
Wire, damaged
PILOT REPORTED THAT THE LT AFT EXTERIOR EMERGENCY LIGHT IS INOPERATIVE. MAINTENANCE TROUBLESHOT TO SOFT SPLICE BETWEEN LIGHT AND GROUND, R & R SOFT SPLICE IAW…
- 8 Jun 2016
Skin, punctured
MAJOR REPAIR DURING A SCHEDULED INSPECTION, MX FOUND A PUNCTURE TO THE LOWER SKIN APPROX 7" TALL BY 2.25" WIDE, 38" OTBD OF INBD EDGE TO 40.25" OTBD OF INBD…
- 25 Oct 2015
Light, inoperative
PILOT REPORTED THAT THE AISLE EMER LIGHTS AT 6A & 7A ARE INOPERATIVE. REPLACED TWO LAMPS PN 3071BPEGPL IAW MM 33-51-01. OPERATIONAL CHECKED GOOD.
- 1 Sep 2015
Light, inoperative
PILOT REPORTED THAT THE WHITE EMER FLOOR EXIT LIGHTING AT ROW 7 IS INOPERATIVE. REPLACED THE BULB IN THE EMER LIGHTING TRACK ON THE FLOOR AT ROW 7, PN 3071BPE…
- 27 Jul 2015
Wire, disconnected
THE FLOOR LEVEL EMERGENCY LIGHTS AT ROW 7 - 8 ARE INOPERATIVE. FOUND A WIRE DISCONNECTED FROM THE LIGHT SOCKET HOUSING. RE-INSERTED THE WIRE & PIN INTO THE…
- 17 Mar 2015
Contact, dirty
PILOT REPORTED THAT THE EMERGENCY LIGHT AT 8A INOPERATIVE. CLEANED LIGHT SOCKET CONTACTS. OPS CHECKED GOOD IAW MM 33-50-00.
- 27 Oct 2014
Bayonet, out of rig
PILOT REPORTED THAT THE MAIN DOOR IS DIFFICULT TO OPEN FROM THE OUTSIDE. RIGGED THE DOOR BAYONETS, OPERATIONS CHECKED GOOD.
- 29 Sep 2014
Terminal, contaminated
SIG EVENT - PILOT REPORTED THAT THERE WAS AN ELEC SMELL & HEAT COMING FROM THE FIRST OFFICER`S CONSOLE. MAINTENANCE REMOVED DEBRIS FROM THE TERMINAL ENDS FOR…
- 18 Jul 2014
Light, not seated
PILOT REPORTED THAT THE EMER LIGHT OVER THE FLIGHT ATTENDANTS SEAT IS INOPERATIVE. RESEATED THE BULB IN THE SOCKET, OPERATIONS CHECKED GOOD.
- 30 Oct 2013
Fan, failed
PILOT REPORTED SMOKE INDICATION, ODOR AS WELL AS VISUAL, TURNED OFF RECIRCULATION AND GASPERS, TURNED OFF BOTH PACKS IAW CHECKLIST AND SMOKE CLEARED. R & R LT…
- 9 Oct 2013
Light, inoperative
PILOT REPORTED THAT THE EMERGENCY LIGHT AT ROW 6 IS INOPERATIVE.
- 1 Sep 2013
Wire, damaged
PILOT REPORTED EMERGENCY LIGHTS AT ROW 6 & 7 INOPERATIVE. REPLACED LAMP IAW MM 33-51-02-4 , REPAIRED WIRES AT ROW 6&7 IAW WM 20-21-00 OPS CHECKED GOOD.
- 2 Aug 2013
Lamp, burned out
PILOT REPORTED THAT THE EMERGENCY LIGHT OVER 8C IS OUT. MX REPLACED THE LAMP, OPS CHECKED GOOD.
- 2 Aug 2013
Lamp, burned out
PILOT REPORTED THAT THE ISLE LIGHT INOPERATIVE ON THE FLOOR NEXT TO SEAT 6A. MX REPLACED LAMP, OPS CHECKED GOOD.
- 20 Apr 2013
Bulb, burned out
EMERGENCY LIGHT AT 6A IS INOPERATIVE. MX REPLACED THE BULB, OPS CHECKED GOOD.
- 18 Apr 2013
Lens, missing
PILOT REPORTED THAT THE RED EMERGENCY EXIT LIGHT LENS IS MISSING IN FRONT OF SEAT 5A. MX REPLACED THE LENS FILTER ON THE LIGHT, OPS CHECKED GOOD.
- 12 Mar 2013
Structure, out of position
PILOT REPORTED THAT THE MAIN DOOR HAS A LARGE GAP AT THE TOP OF THE DOOR MAKING IT DIFFICULT TO OPEN AND CLOSE AND IS LOUD. MX INSPECTED SEAL AND FOUND A TRIM…
- 13 Jul 2012
Frame, cracked
DURING A SCHEDULED ROUTINE INSPECTION FOUND CRACK AT THE BOTTOM OF FRAME 13A UNDER CONDITION CABLE PULLEY, .8" IN LENGTH. REPAIRED THE AFFECTED AREA AND…
- 10 Jul 2012
Skin, dented
MAJOR REPAIR - DURING A SCHEDULED ROUTINE INSPECTION, FOUND THE FUSELAGE SKIN AT FS 4410.5 BETWEEN STRINGERS 19L & 18L ON FRAME 14 DENTED, DENT AT AREAS THAT…
- 12 Jun 2012
Light, inoperative
TWO EMERGENCY LIGHTS IN PAX CABIN WON'T TEST, ONE RED, ONE WHITE BY ROW ONE.
- 11 Jun 2012
Wire, broken
CREW DISCOVERED 2 EMERGENCY LIGHTS IN PAX CABIN THAT WOULD NOT TEST, ONE RED AND ONE WHITE BY ROW 1. MX FOUND A BROKEN WIRE UNDER A COVER BY SEAT 2A, REPAIRED…
- 9 May 2012
Line, punctured
PILOT REPORTED A LOSS OF GREEN HYD SYS PRESSURE, PERFORMED A FREE-FALL EXTENSION OF LANDING GEAR, DECLARED AN EMERGENCY, LANDED WITH NO OTHER INCIDENT. MX…
- 15 Jan 2012
Switch, out of adjust
PILOT REPORTED THAT THE CABIN DOOR ANNUNCIATOR WILL NOT EXTINGUISH WITH THE DOOR CLOSED. MX ADJUSTED THE LOCKING MECHANISM WARNING SWITCH IAW MM 52-71-01, OPS…
- 15 Jan 2012
Rod, out of adjust
PILOT REPORTED THAT THE F/A COULD SEE LIGHT AT THE TOP OF THE AIRSTAIR DOOR AFTER CLOSING. MX ADJUSTED THE FOLDING FLAP ACTUATING RODS IAW MM 52-11-00, STEP…
- 17 Dec 2011
Seal, failed
AT FL 225 THE CABIN BEGAN TO CLIMB AT 3000 FT PER MINUTE. THE PAC'S WERE SELECTED TO NORM BUT THE CABIN CONTINUED TO CLIMB. A DESCENT TO 10,000 FT WAS…
- 8 Dec 2011
Connector, damaged
MX FOUND PIN NR 9 PULLED OUT OF THE EMERGENCY LIGHTING SYS. MX REINSTALLED THE PIN IN THE CONNECTOR, OPS CHECKED GOOD.
- 15 Nov 2011
Spar Cap, cracked
DURING A SCHEDULED ROUTINE INSPECTION, FOUND A CRACK IN THE LT WING FRONT SPAR CAP AT RIB 17, 1 INCH IN LENGTH. MAINTENANCE REPAIRED THE AFFECTED AREA AND…
- 25 Oct 2011
Seal, unsecure
PILOT REPORTED THAT THE CABIN DOOR IS SQUEELING IN FLIGHT, PRESSURIZATION NORMAL. MX RESECURED THE CABIN DOOR SEAL, LEAKS CHECKS GOOD, IAW MM 52-00-01 (A),…
- 4 Oct 2011
Flashlight, cracked
PILOT REPORTED THAT THE COCKPIT FLASHLIGHT BODY IS CRACKED. MX REPLACED THE FLASHLIGHT.
- 5 Sep 2011
Bulb, loose
PILOT REPORTED THAT ON RED EMERGENCY LIGHT AT THE FORWARD DOOR DOES NOT ILLUMINATE. MX FOUND THE BULB LOOSE IN THE SOCKET, SECURED BULB, OPS CHECKED GOOD.
- 10 Aug 2011
Placard, missing
PILOT REPORTED THAT THE PLACARD "REMOVE IN EMERGENCY ONLY" IS MISSING ON THE ROW 5 EMERGENCY EXIT DOOR. MX INSTALLED THE PLACARD, IAW AIM CH 5 SECTION 2.3.0.
- 7 Aug 2011
Sign, unsecure
SIG EVENT - PILOT REPORTED THAT THE SEAT ROW 4 LIGHTED EXIT SIGN FELL OFF. MX RESECURED THE ROW 4 EXIT SIGN, OPS CK GOOD.
- 3 Aug 2011
Oxygen Mask, unwanted deploy
PILOT REPORTED THAT THE ROW 7 OXYGEN MASKS DROPPED. MX REINSTALLED THE O2 MASKS IAW EMM 35-20-00.
- 28 Jul 2011
Proximity Sensor, failed
PILOT REPORTED THAT THE LT LANDING GEAR A SYS LIGHT ILLUMINATED AND GREEN EXTINGUISHED, RED ILLUMINATED ON ROLL OUT. MAINTENANCE RIGGED THE LT GEAR PROX…
- 28 Jul 2011
Proximity Switch, malfunctioned
PILOT REPORTED THAT ON LANDING ROLL OUT THE LT GREEN A LIGHT GOES OUT AND THE LT RED A LIGHT COMES ON INTERMITTENTLY. MAINTENANCE RIGGED THE LT GEAR PROXIMITY…
- 14 Jul 2011
Switch, stuck
"SUP" - SIG EVENT - PILOT REPORTED THAT THE RT PROP FEATHERED WHEN APPLYING TO POWER. MX FOUND RT AND LT TEST SWITCHES STUCK, R & R BOTH TEST SWITCHES, IAW…
- 5 Jul 2011
Placard, missing
"SUP" - SIG EVENT - PILOT REPORTED THAT THE "REMOVE ONLY IN EMERGENCY" PLACARD FELL OFF OF DOOR AT 5A. MX REINSTALLED THE PLACARD ON THE EMERGENCY DOOR 5A,…
- 4 Jun 2011
Sign, loose
PILOT REPORTED THAT THE EMERGENCY EXIT SIGN ABOVE 4C IS NOT PROPERLY SECURED. MX RESECURED THE EMERGENCY EXIT SIGN ABOVE 4C, OPS CK GOOD.
- 15 May 2011
Battery, discharged
SIG EVENT -PILOT REPORTED THAT FLIGHT DECK FLASHLIGHT BATTERIES WERE DEAD. MX REPLACED THE BATTERIES FOR THE FLASHLIGHT.
- 18 Mar 2011
Wheel Half, cracked
CRACK FOUND IN THE BEAD SEAT AREA OF THE INBD WHEEL HALF DURING NDT INSPECTION.
- 18 Mar 2011
Bearing, failed
STARTER GENERATOR WAS RECEIVED, AS WILL NOT STAY ON LINE. DURING PRELIMINARY INSP, THE DRIVE END BEARING HAD BEEN NOTED TO HAD FAILED, CAUSING THE FAULT…
- 21 Jan 2011
Wheel Half, cracked
INBOARD WHEEL HALF CRACKED WHEEL FLANGE.
- 18 Jan 2011
Skin, bent
THE PILOT REPORTED THAT ON HIS WALK-AROUND, FOUND A DENT ON THE LT ELEVATOR, BENT DOWN 5" TO 14" FROM OTBD TIP AND 2.5" FROM T/E, TOP AND BOTTOM SKIN.…
- 2 Sep 2010
Skin, cracked
MAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSP, MX FOUND A CRACK ON THE AIRSTAIR DOOR AFT UPPER MOUNT HOLE FOR THE GUIDE, LOWER AFT CORNER, .5" IN LENGTH. MX…
- 23 Aug 2010
Heat Exchanger, overheated
PILOT REPORTED THAT THERE WAS A BURNED ODOR COMING FROM THE LT PACK, TURNED THE PACK OFF AND THE ODOR WENT AWAY, NO SMOKE. MX REPLACED THE LT HEAT EXCHANGER…
- 2 Aug 2010
Light, burned
F/A OBSERVED SPARKS AND SMOKE FROM ISLE LIGHTING ABOVE ROW 2, SEATS B,C. MAINTENANCE REPLACED THE LIGHT ASSY, REF MM 33-21-02, SYSTEM OPERATIONAL CHECKS GOOD.
- 23 Jul 2010
Light, malfunctioned
PILOT REPORTED THAT THE EMERGENCY LIGHTS NEXT TO ROWS 5 & 7 ARE INOP. MAINTENANCE COULD NOT DUPLICATE THE DISCREPANCY, NO DEFECTS NOTED, OPERATED NORMAL PER…
- 23 Jul 2010
Oil Cooler, leaking
OIL LEAKING FROM NR 1 ENGINE APPEARS TO BE COMING FROM OIL COOLER.
- 25 Jun 2010
Proximity Sensor, failed
UPON CLIMBOUT THE PILOTS REPORTED THAT THE LANDING GEAR WOULD NOT RETRACT WITH THE GEAR HANDLE IN THE UP POSITION. THE GEAR INDICATION HAD SHOWN SIX GREEN…
- 6 Jun 2010
Light, disconnected
EMERGENCY ESCAPE PATH LIGHTING, FIRST RED LIGHT BY CABIN DOOR INOP. MAINTENANCE REMOVED COVER TO THE EMERGENCY LIGHT TRACK AND FOUND LIGHT BULB TO BE…
- 15 May 2010
Light, inoperative
FIRST EMERGENCY EXIT FLOOR LIGHT (RED) IS INOP. MX REPOSITIONED THE LAMP INTO ITS HOLDER IAW MM 120-33-51-02, OPS CHECK NORMAL.
- 12 Apr 2010
Unknown, odor
IMMEDIATELY AFTER LIFTOFF, SMOKE WAS SMELLED IN COCKPIT, THEN SMOKE WAS VISIBLE. VISIBLE SMOKE AND ODOR WERE NOTICED IN COCKPIT BEFORE THEY WERE APPARENT IN…
- 25 Feb 2010
Windshield, deteriorated
PILOTS REPORTED A STRONG CHEMICAL ODOR IN THE FLIGHT DECK AFTER WINDSHIELD HEAT WAS TURNED ON. STARTED 10 MINUTES AFT ACTIVATING THE HEATER A 170 FT AND DID…
- 24 Feb 2010
Unknown, odor
PILOTS REPORTED THAT A STRONG ODOR WAS NOTED WHEN WINDSHIELD HEAT WAS TURNED ON, AFTER ABOUT 1 MIN TO 1 MINUTE AND 45 SECONDS. SMELLED LIKE CHEMICALS RATHER…
- 22 Feb 2010
Unknown, odor
PILOTS REPORTED THAT A STRONG ELECTRICAL ODOR AND VISIBLE SMOKE WAS PRESENT WHEN WINDSHIELD HEAT WAS ON. MX RAN THE WINDSHIELD HEAT FOR 30 MINUTES AND COULD…
- 23 Jan 2010
Door, unlatched
UPON GEAR RETRACTION LOUD VIBRATION CAN BE FELT AND HEARD IN FLIGHT DECK. VIBRATION AN BE FELT THROUGH RUDDER PEDALS AND SEATS. MX FOUND THE GEAR DOOR…
- 13 Jan 2010
Bulb, inoperative
PILOTS REPORTED THAT A STRONG BURNING ODOR APPEARED TO BE COMING FROM THE F/O CHART HOLDER LIGHT. MX REMOVED SOME SEALANT THAT WAS TOUCHING THE BULB OF THE…
- 2 Sep 2009
Cover, loose
PILOTS REPORTED THAT THE EMERGENCY LIGHTING WAS EXPOSED AT THE REAR OF THE CABIN. MAINTENANCE RE-POSITIONED THE EMERGENCY LIGHTING TRACK COVER AND NO FURTHER…
- 28 May 2009
Switch, intermittent
PILOTS REPORTED THAT WHILE CLIMBING THROUGH 13000 FT. THE TORQUE DROPPED TO 0% ON THE NR 2 ENGINE AND EEC AURAL AND ANNUNCIATOR WARNINGS WERE PRESENT WHEN…
- 27 May 2009
Switch, malfunctioned
PILOTS REPORTED THAT WHILE CLIMBING THROUGH 13000 FT. THE TORQUE DROPPED TO 0% ON THE NR 2 ENGINE AND EEC AURAL AND ANNUNCIATOR WARNINGS WERE PRESENT WHEN…
- 27 May 2009
Engine, failed
NR 2 ENGINE FAILED IN FLIGHT AT 13800 TORQUE INDICATIONS WERE AROUND 0-5% EEC WARNINGS WERE SOUNDING OFF. NO ELECTRIC FAILURES INDICATED NH NUMBERS DID NOT…
- 17 Apr 2009
Connector, dirty
PILOTS REPORTED THAT THE GREEN LIGHT ON THE LEFT MAIN LANDING GEAR STAYED ILLUMINATED WHENCEAR CAME UP AFTER TAKEOFF. AFTER RUNNING THE CHECKLIST FOR THE…
- 17 Apr 2009
Sensor, dirty
AIR RETURN, PILOTS REPORTED THAT THE GREEN "B" LIGHT ON THE LT MLG STAYED ILLUMINATED WHEN GEAR CAME UP AFTER TAKEOFF. AFTER RUNNING THE CHECKLIST, THE…
- 26 Mar 2009
Landing Gear, malfunctioned
PILOTS REPORTED THAT AFTER TAKEOFF THE GEAR LEVER SELECTOR WAS SELECTED UP, THEY HEARD THE GEAR IN TRANSIT AND SAW IN TRANSIT LIGHTS. ALL IN TRANSIT LIGHTS…
- 5 Feb 2009
Transmitter, malfunctioned
AUROL WARNING OIL IF FLIGHT AT 24000FT OIL PRESSURE GAUGE READS BETWEEN 45-55PSI, DESCENDING BELOW 180, GAUGE RETURNED TO NORMAL PARAMETERS NORMAL ON GROUND.…
- 4 Feb 2009
Oil System, underserviced
OIL PRESSURE GAUGE FLUCTUATES BETWEEN 45-55 PSI IN FLIGHT ON THE NR 1 ENGINE. MX SERVICED ENGINE WITH 2 QUARTS OF OIL IAW EMB-120 12-12.
- 23 Oct 2008
Stringer, cracked
MAJOR REPAIR - DURING SCHEDULED MAINTENANCE THE NR 8 STRINGER WAS FOUND CRACKED ON THE LOWER WING SKIN JUST INBOARD OF RIB NR 9 NEAR WS 2593. MAINTENANCE…
- 23 Oct 2008
Stringer, cracked
MAJOR REPAIR - DURING SCHEDULED MAINTENANCE THE NR 8 STRINGER WAS FOUND CRACKED ON THE LOWER WING SKIN JUST INBOARD OF RIB NR 5 AT APPROXIMATELY WS 1380.…
- 23 Oct 2008
Stringer, cracked
MAJOR REPAIR - DURING SCHEDULED MAINTENANCE THE NR 10 STRINGER WAS FOUND CRACKED ON THE LOWER WING SKIN JUST INBOARD OF RIB NR 9 AT APPROXIMATELY WS 2443.…
- 15 Oct 2008
Skin, chafed
MAJOR REPAIR - DURING SCHEDULED MAINTENANCE A CHAFE IN AN EXISITING PATCH BETWEEN FRAME 6 & 7 AT STRINGER 15L WAS FOUND. MX REPLACED CHAFED INSERT PATCH IAW…
- 8 Oct 2008
Window Post, cracked
SUPPLEMENTAL INFORMATION - MAJOR REPAIR. CRACK IN RT FWD DV WINDOW POST. C/W EO 04-716L-01 ON RT DV WINDOW IAW THE INCLUDED INSTRUCTIONS AND SB 120-53-0072.…
- 8 Oct 2008
Window Post, damaged
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A MAJOR REPAIR AT THE RIGHT DV WINDOW FORWARD POST DOES NOT CONFORM TO GIVEN DOCUMENTATION. **…
- 8 Oct 2008
Skin, damaged
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A REPAIR AT THE LEFT INBOARD LOWER WING SKIN AT THE OUTBOARD AFT CORNER AND OUTBOARD FUEL PANEL AT…
- 6 Oct 2008
Skin, damaged
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A LEFT FUSELAGE SKIN REPAIR ABOVE THE LEFT HEAT EXCHANGER EXIT DUCT DOES NOT CONFORM TO GIVEN…
- 6 Oct 2008
Stringer, damaged
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A RIGHT HAND INBOARD WING LOWER STRINGER REPAIR BETWEEN WS 2129 & 2593 DOES NOT CONFORM TO GIVEN…
- 6 Oct 2008
Stringer, damaged
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A RIGHT HAND INBOARD WING LOWER STRINGER BETWEEN WS 2129 & 2593 DOES NOT CONFORM TO GIVEN DOCUMENTATION.…
- 3 Oct 2008
Door Frame, cracked
SUPPLEMENTAL INFORMATION - MAJOR REPAIR. DURING ROUTINE SCHEDULED MAINTENANCE A CRACK WAS FOUND IN THE CARGO DOOR FRAME AT THE LOWER AFT CORNER AT A LATERAL…
- 3 Oct 2008
Door Frame, cracked
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A CRACK WAS FOUND IN THE CARGO DOOR FRAME AT THE UPPER FORWARD CORNER AT A LATERAL STOP APPROXIMATELY 1.10…
- 3 Oct 2008
Skin, damaged
MAJOR REPAIR - DURING ROUTINE SCHEDULED MAINTENANCE A REPAIR TO THE BELLY SKIN BENEATH THE TCAS ANTENNA AT FS 5611 BETWEEN FRAMES 17 & 18 AND STRINGERS 21L &…
- 25 Sep 2008
Skin, punctured
SUPPLEMENTAL INFORMATION - MAJOR REPAIR. DURING SCHEDULED MAINTENANCE A HOLE IN THE FUSELAGE IN AN AREA CLOSE TO THE CARGO DOOR PULLEY AREA AT FS 15000.0…
- 11 Jun 2008
Panel, loose
ENROUTE, THE PILOTS REPORTED THAT A LARGE FUEL LEAK WAS OBSERVED IN FLIGHT FROM THE LT FUEL TANK. 300 POUNDS OF FUEL LOST IN ONE HOUR OF FLIGHT. MAINTENANCE…
- 10 Jan 2008
Bleed Air Sys, contaminated
SMOKE/SMELL, PILOTS REPORTED STRONG ODOR OF SMOKE IN CABIN FOLLOWED BY SMOKE AURAL WARNING FROM LAV SMOKE DETECTOR. MAINTENANCE CLEANED BLEED DUCT AND BELLY…
- 9 Dec 2007
Heat Exchanger, deteriorated
SMOKE/SMELL, ENROUTE, PILOTS REPORTED THAT SMOKE FILLED THE COCKPIT AND CABIN OUT OF THE HEATER VENTS. MX RE-INSTALLED A HOSE THAT WAS ASSOCIATED WITH THE LT…
- 21 Jul 2007
Line, leaking
HYDRAULIC SYSTEM FLUID LOSS. PILOTS REPORTED UPON LANDING APPROACH WHEN THE GEAR WAS EXTENDED, THE GREEN HYDRAULIC SYSTEM APPEARED TO HAVE LOST ALL HYDRAULIC…
- 21 May 2007
Cap, dislodged
ENGINE SHUTDOWN ON GROUND, PILOTS REPORTED LT ENGINE OIL PRESSURE DROPPED TO 50 PSI FOR A FEW SECONDS AND THE ENGINE WAS SHUTDOWN IMMEDIATELY. MX FOUND THE…
- 28 Mar 2007
Fan, weak
PILOTS REPORTED AN ODOR OF SMOKE COMING FROM THE VENTS AFTER PARKING AT THE GATE. MAINTENANCE PLACED THE RECIRCULATION FAN ON MEL IAW 21-25-1 CATEGORY C.…
- 22 Mar 2007
Wire, disconnected
FLIGHT 5022 - PILOTS REPORTED THE ODOR OF SMOKE OR FUMES THROUGHOUT THE CABIN. NO INDICATIONS OF FIRE OR SMOKE REPORTED. MAINTENANCE PLACED THE ITEM ON MEL…
- 12 Oct 2006
Warning Message, multiple fail
ILS APPROACH EXPERENCED EMERGENCY BUSS OFF LIGHT, THEN RUDDER OVERBOOST. LOST OF ALL NR 1 COMM, ASI, VSI, FLIGHT DIRECTOR, RMI, NR 1 TQ, T6. ADDITIONAL LIGHTS…
- 30 Nov 2005
A/C Pack, odor
SMOKE ANNUNCIATOR ILLUMINATED THEN CLEARED, PAC'S SMELL LIKE THEY ARE ABOUT TO FAIL IN CLIMBS AND DESCENTS, PERFORMED CHECK OF PACK SYSTEM, NO DEFECTS FOUND,…
- 6 Nov 2004
Panel, leaking
FUEL SEEP RT LOWER I/B PANEL. REPAIRED FUEL LEAK IAW EO 04-71GL-02.
- 11 Jan 2004
Actuator, malfunctioned
FLAP ASSYMETRY CONTROL FAULT, R & R RT OB ACTUATOR PN 3203000-1007 OPS CK GOOD
- 10 Jan 2004
Buss, failed
LOST EMERGENCY DC BUSS IN FLIGHT, REPLACED THE CB0348 WITH SERVICABLE IAW EMB120MM CH24-34. OPS CK GOOD
- 10 Sep 2003
Seal, loose
O2 MASKS DEPLOYED CARGO DOOR SEAL CAME LOOSE, R&R CARGO DOOR SEAL
- 6 Dec 2002
Pressure Switch, faulty
RT LOW HYD PRESS LIGHT FLICKERS. REMOVED AND REPLACED PRESSURE SWITCH, OPS CHECK GOOD.
- 4 May 2002
Socket, defective
RED EMERGENCY LIGHT INOP. REPLACED SOCKET.
- 24 Oct 2001
Door, out of adj
LANDING GEAR WOULD NOT RETRACT ON T/O. ADJUSTED LEFT GEAR DOOR, OPS CHECKED SYSTEM SATISFACTORY.
- 3 Oct 2001
Downlock Sensor, shorted
LANDING GEAR WOULD NOT EXTEND, ELECTRIC OVERRIDE USED. REPLACED RIGHT (A) SYSTEM DOWNLOCK PROX SENSOR, OPS CHECKED SYSTEM SATISFACTORY.
- 7 Jul 2001
Wire, broken
LANDING GEAR WOULD NOT RETRACT ON T/O. INSPECTED FOUND BROKEN WIRE ON LEFT SQUAT SWITCH. REPAIRED, OPS CHECKED SYSTEM SATISFACTORY.
- 17 Feb 2001
Actuator, out of adj
AFTER T/O GEAR FAILED TO RETRACT. CYCLED CONTROL SEVERAL TIMES BEFORE GEAR RETRACTED. ADJUSTED RIGHT MAIN LANDING GEAR ACTUATOR AND UPLOCK SENSOR OPS CHECKED…
- 6 Feb 2001
Plate, out of adj
RETURN TO BLOCK - CARGO DOOR ANNUNCIATOR ILLUMINATED. ADJUSTED TARGET PLATE, OPS CHECKED SYSTEM GOOD.
- 28 Sep 2000
Relay, stuck
ABORTED TAKEOFF. THE NR 1 ELECTRONIC ENGINE CONTROL FAILED TO HOLD THE TAKEOFF PARAMETERS IN AUTO MODE AND WOULD NOT RESET. REPLACED THE REVERSION RELAY.…
- 28 Sep 2000
Line, loose
SMOKE TYPE ODOR FROM THE RIGHT PRESSURIZATION PACK. FOUND THE REFERENCE AIR LINE LOOSE ON THE TEMPERATURE CONTROL VALVE. RESECURED THE LINE, OPERATIONAL CHECK…
- 3 Dec 1999
Wire, failed
INTERIOR EMERGENCY EXIT LIGHT NEAR PASSENGER DOOR INOPERATIVE. REPAIRED GROUND WIRE AT LIGHT ASSEMBLY. (M)
- 8 Sep 1999
Heat Exchanger, dirty
SMELL OF SMOKE IN COCKPIT WHILE TAXIING ALSO LEFT PACK FAILED. FOUND CONTAMINATION IN HEAT EXCHANGER. CLEANED HEAT EXCHANGER. OPERATIONAL CHECK GOOD. (M)
- 18 Jul 1999
Acm, failed
COCKPIT AND CABIN FILLED WITH SMOKE DURING TAXI. SMOKE ALARM ACTIVATED. ALSO, HAD PACK FAIL ILLUMINATION FOR LEFT SIDE AND HOT AIR DISCHARGE IN COCKPIT ON…