N715JB
2008 Airbus A320-232 standard FAA →
registration
- 2008
service difficulty reports
61 reports
- 11 Oct 2026
Switch, faulted
FLT#2751, TPA-SJU. EMERGENCY LIGHT DOES NOT WORK IN NORMAL CONFIG; R/R NO SMOKE SIGN TOGGLESWITCH. AS PER ESPM 20-45-21. OPS CK OK AS PER AMM 33-51-00.
- 17 Sep 2026
Unknown, odor
FLT 8348, LAS-JFK. DURING DESENT BOTH PILOTS DETECTED 'MAGIC MARKER' SMELL REPORTED BY PREVIOUS CREW SMELL WAS STRONG ENOUGH THAT BOTH PILOT NEEDED O2 AS A…
- 14 Sep 2026
Unknown, odor
FLT 411, JFK-LAS. OPERATING F411 FROM JFK TO LAS REPORTED THE FOLLOWING. DESCENDING THRU 11000' WE STARTED TO GET AN ODOR IN THE COCKPIT. THE ODOR WAS SIMILAR…
- 9 Sep 2026
A/C Pack, odor
FLT1447, HPN-TPA. WEIRD ODOR DESENDING THRUGH 12000 IDLE POWER ISOLATED PACK 1 ODOR DIMMININGED, ISOLATED PACK 2 ODOR DISSAPATED, C/W TSM 05-50-00-810-831-A…
- 21 Aug 2026
Line, damaged
FLT 302, FLL-JFK. LEVEL TWO ODOR AT 4000 FEET IN THE DESCENT RESOLVED WITH STEP 9 WITH ODOR ISOLATION CHECKLIST 3 FLIGHT ATTENDANTS IN THE BACK ODOR IT ALSO…
- 13 Aug 2026
Starter, leaking
FLT # 234, BOS-MCO. OIL SMELL FORM 15000FT TO THE GROUND DID ISOLATION CHECKLIST WAITED 3 MIN TURNED ON AND ODOR WAS AT THE SAME LEVEL 2; COMPLIED WITH INFO…
- 24 Aug 2025
Unknown, odor
FLT 1962, PBI-LGA, DURING CLIMB, STRONG PERSISTENT & INCREASING INDICATION OF OIL FUMES. LEVEL 3 DETERMINED USING FOM AND ISOLATION CHECKLIST. PACK 1…
- 14 May 2025
Unknown, odor
FLT#813, HPN-FLL. '1/2 WAY THOURGH FLT F1 SAID MILD DIRTY SOCK SMELL ROWS 7 8 9 HE SAID HE NOTED IT DURING FINAL COMPLIANCE AS WELL (BEFORE T/O) (IT WAS NOT…
- 25 Mar 2025
A/C Pack, fumes
FLT#1588, SXM-JFK. 'LEVEL 1 FUMES EVENT FROM PACK 1 IN THE DESCENT AT 11000FT DID ISOLATION PROCEDURE AND AFTER 3-5 MIN THE SMELL BACK SO LEFT PACK 1 OFF AND…
- 18 Mar 2025
Unknown, odor
FLT#2904, RSW-BDL. 'ODOR/ FUME EVENT. DURING DESCENT FA'S IN AFT GALLEY REPORTED A FUEL SMELL IN THE FLIGHT DECK WE SMELLED A DIRTY SOCK SMELL. ( PACKS ).'…
- 20 Dec 2024
Apu, odor
FLT# 8360, SJU-FLL. 'FUMES SMELL ON DESCENT AT ABOUT 10,000MSL UNTIL LANDING APU WAS OFF; C/W INFORMATION NOTICE 2017-T015, SECTION B2. DECONTAMINATION LEVEL…
- 18 Dec 2024
Unknown, odor
FLT# 2933, MCO-SJU. 'FUME DIRTY SOCK SMELL FOUND IN CABIN BEFORE FLIGHT; COMPLIED WITH INFORMATION NOTICE 2017-T015 SECTION B2 IDENTIFIED ODOR.…
- 13 Nov 2024
A/C Pack, abnormal
FLT#1009, JFK-SDQ. 'GOING THROUGH APPROXIMATELY 15000 ON DESCENT TEH CAPT SMELLED AN ACRID ODOR DIRTY SMELL. NOT DIRTY SOCKS. APPROX 10000 # 4 INFLIGHT CALLED…
- 19 Oct 2024
Tail Cone, damaged
DURING HEAVY MAINTENANCE: FUSELAGE/ REAR FUSELAGE/ TAIL CONE/ FR 78-81 STGR 2L-2R/ MULTIPLE DAMAGE- PERMANENT REPAIR; REFERENCES /1/ AEROMAN EA 53-9042-24…
- 19 Oct 2024
Skin, damaged
DURING HEAVY MAINTENANCE: MISSING MATERIAL ON EXTERNAL SKIN LOCATED BTW FRAME 78 TO FRAME 80 PLUS 4 INCH AND BTW STRINGER 1 LH TO 1RH THS COMPARTMENT;…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FWD AND AFT SIDE OF THE FRAME SEGMENT (1) THE EEH 834 PASSENGER CABIN CRACK LENGTH IS 0.280 INCH; REMOVED…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FWD AND AFT SIDE OF THE FRAME SEGMENT (1) THE EEH 843 PASSENGER CABIN CRACK LENGTH IS 0.315 INCH; REMOVED…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FWD AND AFT SIDE OF THE FRAME SEGMENT (1) THE EEH 844 PASSENGER CABIN CRACK LENGTH IS 0.350 INCHES;…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FWD AND AFT SIDE THE FRAME SEGMENTS (1) THE EEH 833 CRACK LENGTH IS 0.330 INCH; REMOVED AND REPLACED THE…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR16 AT FWD GALLEY AREA DOOR STOP FITTING 7 LOWER I/B, LH SIDE CRACK POSITION AT 1 O'CLOCK; (RESOLVED ON W/O:…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR16 AT FWD GALLEY AREA, DOOR STOP FITTING 7 UPPER I/B LH SIDE, AT 6 O'CLOCK; REF: ARM W/O 2024 314/1 N/R…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR16 AT FWD GALLEY AREA, DOOR STOP FITTING 7 UPPER I/B RH SIDE, CRACK POSITION 7 O'CLOCK; REF: ARM W/O 2024…
- 19 Oct 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR16 AT FWD GALLEY AREA DOOR STOP FITTING 7 LOWER INBOARD RH SIDE POSITION AT 6 O'CLOCK; REF: ARM W/O 2024 314/1…
- 19 Oct 2024
Crossbeam, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FASTENER HOLE H2, LOCATED ON CROSSBEAM SPLIC AREA FR16 LH SIDE ON PASSENGER CABIN; REF; ARM W/O 2024 314/1…
- 7 Jun 2024
Oil Cooler, leaking
FLT#1167, HPN-PBI. 'F/A REPORT DIRTY SOCK SMELL MID AND AFT CABIN; REMOVED AND REPLACED APU OIL COOLER IAW AMM 49-91-44. OPS / LEAK CHK GOOD. RAN APU FOR 45…
- 5 Jun 2024
Oil System, leaking
FLT#1287, PVD-PBI. FA REPORTED DIRTY SOCK SMELL AFT GALLEY ON DESCENT AT 4000'; COMPLIED WITH INFO NOTICE 2017-015K. IDENTIFIED ODOR CAUSED BY APU OIL LEAK.…
- 29 Oct 2023
Unknown, unknown
FLT#2188, BNA-LGA. 'DESCENDING FROM ALTITUDE FROM 25000-18000 SMELLED DIRTY SOCKS IN COCKPIT AND REAR CABIN THRUST IDLE CLEAR AIR APU OFF ODOR INCREASE AS…
- 26 Sep 2023
Unknown, unknown
FLT#1248, TPA-LGA. 'DIRTY SOCK SMELL TURNED OFF PACK 1 AND SMELL SUBSIDED ( APU BLEED AIR SUPPLY SYSTEM ); T/S APU ODOR PER AMM 49-00-00-200-811-A, AND FOUND…
- 23 Sep 2023
Unknown, unknown
FLT#1248, TPA-LGA. 'ON TAKEOFF VERY STRONG CHEMICAL /MUSTY ODOR IN FLIGHT DECK.FUMES/ODOR WERE MAGIC MARKER /SWEET SMELLING. ODOR WAS MODERATE AND INTENSITY…
- 12 Sep 2023
Unknown, unknown
FLT#39, FLL-SJO. 'DURING DESCENT BELOW 10000 CABIN CREW REPORTED DIRTY SOCKS ODOR MID CABIN AND REAR LEVEL 1 - APU OFF; COMPLIED WITH INFO NOTICE 2017 - T015…
- 8 Aug 2023
Unknown, unknown
FLT#299, LGA-MCO. 'INFLIGHT REPORT DIRTY SOCK ODOR IN CABIN; COMPLIED WITH INFO NOTICE 2017-T015, SECTION B2. DECONTAMINATION LEVEL B WAS ACCOMPLISHED PER TSM…
- 8 May 2022
None, none
FLT#2320, SLC-FLL. ' LEVEL 1 ODOR EVENT IN CRUISE 2 AND HOURS INTO FLT. INFLIGHT REPORTED A STRONG DIRTY SOCK SMELL IN THE AFT RIGHT GALLEY. THE SMELL WOULD…
- 12 Apr 2022
None, none
FLT#655, SYR-MCO. 'FUMES STRONG CHEMICAL BURNING SMELL DESCENDING THROUGH 5,000; AS PRECAUTIONARY PERFORMED ENGINE RUNS (ENG 1-2)- WITH ASSOCIATED PACKS,…
- 4 Apr 2022
None, failed
FLT#149, JFK-GND. 'AFTER LANDING FLIGHT ATTENDANTS REPORTED DIRTY SOCKS SMELL PASSING THROUGH 10,000FT UNTIL LANDING REPORTING HEADACHES. APU WAS OFF. THE…
- 1 Apr 2022
Ecs, contaminated
FLT#1447, HPN-TPA. 'ACRID SMELL ORIGINATING FROM BLEED ENG 1 ISOLATED SYSTEM AND SMELL WENT AWAY; COMPLIED WITH INFORMATION NOTICE 2017-T015I, SECTION A.…
- 8 Mar 2022
None, none
FLT#1521,LGA-FLL. 'LEVEL 2 FUMES EVENT ON LEVEL OFF BEOLW 800O', PILOTS & BACK F/A DETECTED IT. ISOLATED PACK 1, WENT AWAY UPON TOUCHDOWN; RAN ENGINES #1 AND…
- 16 Jan 2022
Unknown, odor
FLT # 1853, JFK-PBI. INBD CABIN CREW REPORTS ELETIRC ODOR ON PREVIOUS DESCENT FROM 10,00 FEET TO TOUCH DOWN ODOR THROUGHOUT CABIN. ( THALES-AVANT IFE (ENTIRE…
- 14 Jan 2022
Door, damaged
FLT # 894, STI-EWR. WHILE AGR WAS MOVING THE AIRCRAFT OFF THE GATE, THE AIRCRAFT ROLLED BACK DUE TO MAIN LANDING GEAR WHEELS NOT BEING CHOCKED. L1 DOOR MADE…
- 3 Sep 2021
Battery, failed
FLT 1076, MCO-PVD. EXIT SIGN ON DOOR 2R IS NOT ILLUMINATED; R & R BATTERY OF THE EPSU. OPS CHECK GOOD. REF AMM 33-51-38
- 2 Sep 2021
Cover, displaced
DURING HEAVY MAINTENANCE, PUSHED ENCLOSURE OFF WING SCAPE SLIDE . ALL THE BALLS ARE IN ON LH WING; (REF ARM W/O 2021-197/1 N/R 2021-355368) R & R OFFWING…
- 2 Sep 2021
Battery, no test
DURING HEAVY MAINTENANCE, EPSU BATTERY 10WL DON'T PASS TEST; (REF ARM W/O 2021-197/1 N/R 2021-381719) R & R EPSU 10WL IAW AMM 33-51-38-000-002-A AND…
- 2 Sep 2021
Battery, no test
DURING HEAVY MAINTENANCE, EPSU BATTERY 11WL DON'T PASS TEST; (REF ARM W/O 2021-197/1 N/R 2021-381720) R & R EPSU 11WL IAW AMM 33-51-38-000-002-A AND…
- 2 Sep 2021
Battery, no test
DURING HEAVY MAINTENANCE, EXIT SIGN ON DOOR 2R DID NOT ILLUMINATE; R & R BATTERY OF THE EPSU. OPS CHECK GOOD. REF AMM 33-51-38
- 29 Jan 2021
Fan, failed
FLT 110, SDQ-JFK. FELT VIBRATION WITH ELECTRICAL BURNING SMELL VENT EXTRACT FAULT ECAM CAUTION; R & R EXTRACT FAN REF AMM 21-26-51 OPS CCHECK OK FAULTS…
- 20 Jul 2019
Unknown, odor
FT # 499, LGA-MCO. TRICRESYL PHOSPHATE ODOR/ FUME STARTED IN DECENT AT 12,000 FUMES DISSIPATED WITH PACK 2 OFF FUME REPORT ATTACHED; ODOR IS DETERMINED TO BE…
- 18 Feb 2019
Slide, defective
DURING HEAVY MAINTENANCE, BUMP IN PAX DOOR SLIDE 832; REF AEM NR 2019-14/1 - 2019-50048. REPLACED ESCAPE SLIDE RAFT AT 832 IAW AMM 25-62-44-400-002-A.…
- 9 Jan 2019
Structure, corroded
FLT 2191. BOS-TPA. AIRCRAFT WAS FOUND WITH CORROSION DAMAGE AT THE LAVATORY VENT LOCATED IN THE REAR FUSELAGE BETWEEN FR 69-70 AND STR 31R-32R. THE AIRCRAFT…
- 9 Jan 2019
Vent, corroded
FLT 2191. BOS-TPA. AIRCRAFT WAS FOUND WITH CORROSION DAMAGE AT THE LAVATORY VENT LOCATED IN THE REAR FUSELAGE BETWEEN FR 69-70 AND STR 31R-32R. THE AIRCRAFT…
- 9 Jan 2019
Vent, corroded
FLT 2191,BOS-TPA. ON 1/9/2019 WAS FOUND WITH CORROSION DAMAGE AT THE LAVATORY VENT LOCATED IN THE REAR FUSELAGE BETWEEN FR 69-70 AND STR 31R-32R. THE AIRCRAFT…
- 14 Mar 2018
Battery Pack, no test
EPSU BATTERY 10WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY IAW AMM 33-51-38, SYSTEM OPS CHECKED GOOD.
- 29 Jun 2017
Connector, dirty
DURING HEAVY MAINTENANCE, EMERGENCY LIGHTS FAILED AN EPSU SYSTEM TEST. CLEANED AND RECONNECTED 43WL, 42WL, 44WL AND 45WL IAW AWM 33-51-03 SHEET 02. OPS CHECK…
- 22 Jan 2017
Battery Pack, failed
EMERGENCY LIGHTS IN AUTO DID NOT ILLUMINATE WHEN POWER DROPPED OFF. R & R THE BATTERY PACK AT 10WL IAW AMM 33-51-00. OPS CHECKED GOOD.
- 21 Jan 2017
Apu, odor
FLIGHT ATTENDENTS AND PAX SMELLED A STRONG FOUL ODOR PASSING THROUGH 10,000 FT DURING DESCENT; FOUND APU TO BE THE SOURCE OF THE ODOR. R & R THE APU.
- 18 Apr 2016
Skin, corroded
CORROSION FOUND ON LT WING UPPER SURFACE AT RIB 2, STR 11, FASTENER HOLE 606 IN UPPER LAYER OF BORE. REF DWG 571183A57120, SHEET 01; REPAIRED IAW ECA16-294-01…
- 18 Apr 2016
Skin, corroded
CORROSION FOUND ON RT WING T/E TOP SKIN OF RIB 15, UNDER ATTACH POINT FOR GLASS CLOTH SEAL PLATE. REPAIRED ECA16-287-01 AND REO L19816RI.
- 14 Dec 2015
Battery, failed
EMERGENCY LIGHT FAILS TEST. R & R EMERGENCY LIGHT BATTERY AT 12WL. EMERGENCY LIGHT, OPS CHECK GOOD.
- 28 Feb 2013
Proximity Sensor, failed
FLT 374 FLL-LGA, AIRCRAFT DIVERTED TO JFK DUE TO UPON GEAR SELECTION DOWN GOT ECAM L/G DOOR NOT LOCKED FOLLOWED BY LANDING GEAR NOT DOWN INDICATION (LDG GEAR…
- 10 Jun 2011
Battery, failed
FLT 654 SJU-TPA EPSU BATT FIN 11WL FAILS BATT CAP TEST. REPLACED BATTERY AT EPSU FIN 11WL PER AMM 33-51-38, OPS CHECKED OK.
- 7 Jun 2011
Proximity Sensor, failed
FLT 61 JFK-FLL, CREW DECLARED EMERGENCY DUE TO UPON GEAR EXTENSION INDICATION OF GEAR DOORS NOT CLOSED AND ON LOWER ECAM RT MAIN GEAR 1/2 OF GEAR TRIANGLE…
- 20 May 2011
Gcu, failed
FLT 47 JFK-FLL, AIR RETURN BACK TO JFK- GEN 2 FAULT ON ECAM AFTER TAKEOFF AT 5000FT 250 KNOTS. CYCLE PUSH BUTTON GEN 2, NEVER CAME BACK ONLINE. REMOVED AND…
- 14 Aug 2008
Powerplant, flamed out
FLT 354, BUR-JFK, UPON LANDING NR 1 ENG FLAMED OUT ON ROLL OUT, AFTER ENG 1 COMP FAIL ECAM FOLLOWED BY ENG 1 FAIL ECAM. DVDR ANALYSIS DETERMINED NR1 ENG…