- 27 Feb 2013
Holder, broken
DURING MAINTENANCE INSPECTION FOUND THE FLIGHT ATTENDANT FLASHLIGHT HOLDER BROKEN. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FLIGHT…
- 19 Jan 2013
Connector, defective
DURING MAINTENANCE INSPECTION FOUND THE EMERGENCY LIGHT ON THE SERVICE DOOR INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE WIRE…
- 14 Jan 2013
Light, inoperative
DURING B INSPECTION FOUND THE LEFT OVERWING EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LAMP IAW 33-50-10. THE…
- 5 Jan 2013
Flashlight, unserviceable
ON FLIGHT 3248 THE CREW REPORTED THE CAPTAIN'S FLASHLIGHT WOULD NOT STAY IN FLASHLIGHT HOLDER/CHARGER. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND…
- 15 Nov 2012
Wire, broken
DURING B INSPECTION FOUND THE SERVICE DOOR EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED BROKEN WIRE AT SERVICE DOOR EMERGENCY…
- 26 Oct 2012
Acm, malfunctioned
FOR FLIGHT 2802 THE CREW REPORTED THAT WHILE PARKED AT THE GATE RUNNING APU FOR ABOUT 20 MINUTES CLOSED THE MAIN DOOR AND ABOUT 30 SECONDS LATER HAD SMOKE IN…
- 19 Oct 2012
Fan, malfunctioned
ON FLIGHT 2802 THE CREW REPORTED THAT AFTER LANDING THE SMELL OF ELECTRICAL SMOKE WAS DETECTED AND THEN DISSIPATED SHORTLY THEREAFTER. THE AIRCRAFT WAS…
- 19 Oct 2012
Light, inoperative
DURING MAINTENANCE INSPECTION FOUND THE 4TH EMERGENCY LIGHTING STRIP FROM REAR INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE…
- 18 Jul 2012
Unknown, odor
FLIGHT 3337, RAMP CREW REPORTED THEY NOTICED A SMOKE ODOR IN CARGO BAY. AIRCRAFT REMOVED FROM SERVICE. INSPECTED CARGO BAY FOR OBVIOUS DEFECTS, NONE NOTED.…
- 10 Jul 2012
Light, inoperative
DURING MAINTENANCE INSPECTION, FOUND THE OVERHEAD AISLE EMERGENCY EXIT LIGHT OUT. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE OVERHEAD AISLE…
- 28 Dec 2011
Light, inoperative
MEL 3330. EMERGENCY FLOOR PROXIMITY LIGHT INOP ON FLOOR SEATS 5 AND 6. REMOVED AND REPLACED EMERGENCY FLOOR PROXIMITY LIGHT STRIP AT SEATS 5 AND 6 IAW EMB 135…
- 23 Dec 2011
Light, inoperative
EMERGENCY LIGHT FLOOR PROXIMITY STRIP INOP SEAT 5 & 6. DEFERRED PER MEL 33-30, M PROCEDURE C/W.
- 22 Dec 2011
Light, inoperative
FOUND 2ND LIGHT STRIP EMERGENCY AISLE INOP. REMOVED AND REPLACED AISLE LIGHT STRIP EMERGENCY IAW EMB-135 AMM 33-50-08. OPS CHECK GOOD.
- 23 Apr 2011
Antenna, damaged
ON FLIGHT 2895 CREW REPORTED ACFT EXPOSED TO SEVERE AND EXTREME TURBULENCE, LIGHTNING STRIKES & STRONG VIBRATIONS THROUGH COCKPIT FLOOR & CABIN ROW 2. CREW…
- 17 Mar 2011
Support Bracket, cracked
DURING MAINTENANCE VISIT FOUND THE PASSENGER DOOR INTERNAL HANDLE SUPPORT BOX BRACKET CRACKED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED PASSENGER DOOR…
- 6 Mar 2011
Light, inoperative
FOR FLIGHT 2712 DURING PREFLIGHT INSPECTION FOUND THE FIRST CEILING EMERGENCY LIGHT TO BE INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND…
- 5 Dec 2010
Warning System, malfunctioned
ON FLIGHT 4470 THE CREW REPORTED A FLAP FAIL MESSAGE ON EICAS WHEN SELECTED TO 9 DEGREES FLAPS STAYED AT 0 DEGREES. THE CAPTAIN DECLARED AN EMERGENCY AND THE…
- 29 Oct 2010
Cradle, broken
FOR FLIGHT 4547 DURING TAXI THE REAR CABIN FLASHLIGHT WAS LOOSE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE AFT CABIN FLASHLIGHT AND…
- 25 Aug 2010
Ballast, defective
ON FLIGHT 4524 THE CREW REPORTED A STRONG SMOKE ODOR COMING FROM A PASSENGER SERVICE UNIT AT SEAT 8A IN THE CABIN. THE CAPTAIN DECLARED AN EMERGENCY AND THE…
- 5 Dec 2009
Flap System, malfunctioned
DURING FLIGHT 4546 WHILE ON APPROACH THE CREW RECEIVED A FLAP FAIL MESSAGE. THE MESSAGE INDICATED THAT THE FLAPS WERE ON 0 DEGREES. THE CREW DECLARED AN…
- 3 Dec 2009
Brake, failed
DURING FLIGHT 4485 ON APPROACH THE CREW REPORTED A FLAP FAIL. THE CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM…
- 5 Nov 2009
Flap, malfunctioned
ON FLIGHT 4552 DURING DESCENT WHILE SELECTING FLAPS 9 FROM ZERO THE CREW RECEIVED AN EICAS FLAP FAIL MESSAGE. THE MESSAGE INDICATED ZERO DEGREES. THE CREW…
- 25 Oct 2009
Velocity Sensor, defective
ON FLIGHT 4472 DURING THE DESCENT THE CREW REPORTED A FLAP FAILURE MESSAGE ON EICAS. THE CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. THE AIRCRAFT…
- 29 Apr 2009
Unknown, odor
ON FLIGHT 3226 CREW REPORTED, RETURNED TO GATE DUE TO AN ELECTRICAL BURNING ODOR IN THE COCKPIT. AIRCRAFT REMOVED FROM SERVICE. PERFORMED VISUAL INSPECTION,…
- 9 Apr 2009
Floor Support, corroded
DURING A MBV INSPECTION, THE CENTER OMEGA BEAM AT FRAME 38 WAS FOUND CORRODED. PERFORMED A CUT OUT OF THE OMEGA BEAM TO REMOVE THE DAMAGE. PREPARED A DOUBLER,…
- 7 Apr 2009
Floor Support, corroded
DURING A MBV INSPECTION, THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 38. PERFORMED A CUTOUT TO REMOVE THE CORROSION. TRIMMED EPNEM5354701 AND 54703…
- 6 Apr 2009
Floor Support, corroded
DURING MBV, THE CENTER OMEGA BEAM WAS FOUND CORRODED. REMOVED CORROSION AND PERFORMED NDR INSPECTION. CLEANED, ALODINED, PRIMED AND FILLED BLEND AREA.…
- 2 Aug 2007
Relay, failed
EMERGENCY LIGHTS NOT ARM AND ELECTRICAL EMERGENCY ABNORMAL MESSAGE, ABORTED TAKEOFF. REMOVED AND REPLACED BATTERY RELAY BOX IAW EMB AMM 24-33-02. OPERATIONAL…
- 7 Jun 2007
Unknown, odor
SMOKE APPEARED AFTER SELECTING CRUISE THRUST, EMERGENCY DECLARED. DIVERTED TO JFK. PERFORMED TROUBLESHOOTING IAW ROLLS ROYCE FAULT ISOLATION MANUAL 72-00-00…
- 21 Mar 2007
Unknown, smoke
SMOKE REPORTED IN CABIN AFTER NR 1 ENGINE START. PERFORMED VISUAL INSPECTION OF NR 1 ENGINE, APU AND BOTH PACKS WITH NO DEFECTS NOTED. PERFORMED ENGINE START…
- 16 Feb 2007
Floorbeam, corroded
PREVIOUS REPAIR ON LEFT OMEGA BEAM AT FRAME 20 CORRODED. FABRICATED AND INSTALLED REPAIR DOUBLERS AND FILLERS. CLEANED, TREATED AND RESTORED PROTECTIVE FINISH…
- 13 Feb 2007
Sill, corroded
FOUND CARGO DOOR FRAME LOWER SILL CORRODED. REMOVED EXISTING SILL, CLEANED AND TREATED REPAIR AREA. INSTALLED NEW SILL IAW EMB SRM 51-40-02. RESTORED…
- 13 Feb 2007
Sill, corroded
BAGGAGE DOOR FRAME LOWER SILL FOUND CORRODED. REMOVED EXISTING SILL, CLEANED AND TREATED AREA. INSTALLED NEW SILL IAW EMB SRM 51-40-02. RESTORED PROTECTIVE…
- 13 Feb 2007
Skin, dented
FOUND RIGHT NOSE SKIN DENTED BETWEEN STRINGER 13 RIGHT AND 16 RIGHT AND FRAMES 7 AND 8. PERFORMED RECONTOUR OF DENT, PERFORMED NDT. FABRICATED AND INSTALLED…
- 24 Oct 2006
Flap System, malfunctioned
ON APPROACH SELECTED FLAPS 9, FLAPS STAYED AT 0 WITH ASSOCIATED EICAS MESSAGE "FLAP FAIL". NO CIRCUIT BREAKERS POPPED. COMPLIED WITH AIRCRAFT OPERATING MANUAL…
- 7 Jul 2005
Floor Support, corroded
THE CENTER OMEGA BEAM AT FRAME 25 WAS FOUND CORRODED. PERFORMED A CUT OUT OF THE CENTER OMEGA BEAM TO REMOVE CORROSION FABRICATED A FILLER DOUBLER AND 2…
- 7 Jul 2005
Floorbeam, corroded
THE GALLEY AREA FORWARD DIGITAL PREVIOUS REPAIR WAS FOUND CORRODED. REMOVED THE EXISTING REPAIR, BLENDED THE DAMAGE AREA OF THE FORWARD DIGITAL TO REMOVE THE…
- 23 Jun 2003
Floorbeam, corroded
ABI - DURING AN IMBV INSPECTION, THE LEFT OMEGA BEAM LOEW FLANGE AND WEB WERE FOUND TO BE CORRODED BEYOND SRM LIMITS BETWEEN FRAMES 20 AND 22. BLENDED THE…
- 21 Jun 2003
Floorbeam, corroded
ABI - DURING AN IMBV INSPECTION, FOUND CORROSOIN ON THE EXISTING REPAIR ON THE LEFT OMEGA BEAM AT FRAME 20. REMOVED EXISTING REPAIR. FABRICATED AN EXTERNAL…
- 18 Jun 2003
Sill, corroded
ABI - DURING AN IMBV INSPECTION, THE SERVICE DOOR CENTER SILL WAS FOUND TO BE CORRODED BELOW SRM LIMITS. REMOVED EXISTING CENTER SILL, INSTALLED NEW CENTER…
- 10 Mar 2003
Odor, detected
CMH - FLT 4576 - AFTER TAKEOFF, THE FLIGHT ATTENDANT REPORTED STRONG BURNING RUBBER ODOR. PERFORMED PNEUMATIC BLEED CHECK WITH BOTH ENGINES AND APU OPERATING…
- 23 Nov 2002
Engine, malfunctioned
LGA - FLT 4401 - AFTER TAKEOFF, CREW REPORTED LAVATORY SMOKE MESSAGE ON EICAS AND SMOKE IN CABIN. APU ALREADY ON MEL. MAINTENANCE REMOVED AND REPLACED THE…
- 22 Nov 2002
Solenoid, malfunctioned
CMH - FLT 4564 - AFTER TAKEOFF, CREW REPORTED SMELLING FUMES IN COCKPIT AND FLIGHT ATTENDANT REPORTED A HAZE IN THE CABIN LIKE A BURNING PLASTIC SMELL.…
- 13 Nov 2001
Support, corroded
THIS IS A LEVEL 2 FINDING ON A CORROSION REPAIR ITEM. GALLEY RAMP SUPPORT CORRODED. REMOVED RAMP SUPPORT AND INSTALLED NEW RAMP IAW EMB 135/145 SRM 51-40-02.…
- 13 Nov 2001
Floor Support, corroded
ABI - THIS IS A LEVEL 2 FINDING ON A CORROSION REPAIR ITEM. GALLEY CENTER BEAM GUSSET CORRODED. RAI SERVICEABLE GALLEY CENTER BEAM IAW EMB 135 SRM 51-40-02. (M)
- 25 Oct 2001
Floorbeam, corroded
ABI - DURING MBV INSPECTION OF AIRCRAFT, FOUND CORROSION ON THE FORWARD DIGITAL IN GALLEY AREA. REMOVED CORROSION BY BLENDING IT OUT. PERFORMED AN NDT…
- 25 Oct 2001
Floorbeam, corroded
DURING MBV INSPECTION, FOUND CORROSION ON THE GALLEY LEFT OMEGA BEAM AT FRAME 20. REMOVED CORROSION BY CUTOUT. FABRICATED FILLER AND DOUBLER. REPAIR DONE IAW…
- 19 Mar 2001
Rod, out of adj
ORD - FLT 4230 - DURING TAKEOFF ROLL, CREW NOTED T/REV DISAGREE MSG ON EICAS. CREW ABORTED TAKEOFF AND RETURNED TO GATE SAFELY. NO FURTHER INCIDENTS WERE…
- 14 Mar 2001
Relay, failed
ORD - FLT 4123 - DURING TAKEOFF ROLL, AFTER 80 KNOTS BUT PRIOR TO Y1 CREW RECEIVED THE NR 2 REVERSER DISAGREE MESSAGE. TAKEOFF WAS ABORTED. MESSAGE CLEARED…
- 27 Jul 2000
Switch, malfunctioned
BOS - FLT 5172 - DURING TAKEOFF ROLL, CREW NOTED NR 2 THRUST REVERSER DISAGREE MESSAGE. ABORTED TAKEOFF AND RETURNED TO GATE. NO FURTHER INCIDENTS REPORTED.…
- 18 Jun 2000
Squat Switch, dirty
RIC - FLT 4941 - ON TAKEOFF ROLL, CREW HAD THRUST REVERSER NR 2 DISAGREE AND NR 1 THRUST REVERSER ALREADY ON MEL. MAINTENANCE REMOVED METALIC PASTE FROM MLG…