N708JB
2008 Airbus A320-232 standard FAA →
registration
- 2008
service difficulty reports
48 reports
- 31 Oct 2026
Interface Unit, failed
FLT 2098, FLL-ATL (AIR RETURN). ON CLIMBOUT WE HEARD A RHYTHMIC BANGING FROM THE COCKPIT TO ROW 8 (PER CUSTOMER) ON/AT GEAR RETRACTION SHORTLY AFTER ECAM L/G…
- 30 Aug 2026
A/C Pack, odor
FLT 2472, BQN-FLL. AFT FLT ATTENDANTS SMELLED ROTTEN EGG ODOR MULTI[PLE TIME DURING CLIMB AND CRUISE PERFORMED ODOR ISOLATION PROCEDURES FOR AFT CABIN AFTER…
- 29 Mar 2025
Microphone, failed
FLT#2476, SJU-BDL. (AIRCRAFT PERFORMED AN AIRTURN BACK TO SJU) ACP ONE WENT INTO TRANSMIT CAP SIDE SPEAKER WOULD HAVE TRANSMIT TONER P.A. BUTTON INOP ON ACP…
- 29 Nov 2024
String, corroded
DURING HEAVY MAINTENANCE: FUSELAGE / AFT FUSELAGE / STRINGER 37 LH BETWEEN FR 62-63 / CORROSION - PERMANENT REPAIR; REFERENCES: /1/ AEROMAN EA 53-9059-24 REV.…
- 29 Nov 2024
Cargo, corroded
DURING HEAVY MAINTENANCE: CORROSION LOWER SILL DOOR IN BULK CARGO COMPARTMENT; REF AEROMAN NR 2024-649062 WO 2024 263/1 REMOVED REPLACED LOWER SILL LOCATED…
- 29 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK FOUND ON DOOR FRAME IN PASSENGER (1 EACH) HOLE H3 ON DOOR STOP1 FR68 LH CRACK DEPTH .100 INCH AND DIRECTION 6 O CLOCK;…
- 29 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK FOUND ON OPEN HOLE H1 ON DOOR STOP 7 FR 66 RH CRACK DEPTH .100 INCH AND DIRECTION 12 O CLOCK; (RESOLVED ON W/O: 1324769…
- 29 Nov 2024
Intercostal, cracked
DURING HEAVY MAINTENANCE: CRACK FOUND ON HOLE H1 OF INTERCOASTAL FITTING AT FR 16 LH DOOR STOP FITTING N7 AREA; REMOVED AND REPLACED INTERCOSTAL FITTING…
- 29 Nov 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (FWD LH EEH DOOR 833) CRACK L=0.150 INCH APPROX;…
- 29 Nov 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (AFT LH EEH DOOR 834) CRACK L=0.\130 INCH APPROX;…
- 29 Nov 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (AFT RH EEH DOOR 844) CRACK L=0.128 INCH APPROX;…
- 29 Nov 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (FWD RH EEH DOOR 843) CRACK L=0.135 INCH APPROX;…
- 24 Apr 2024
Windshield, leaking
FLT#149, JFK-GND. (AIRCRAFT PERFORMED AN AIR TURN BACK) 'CAPTAINS FIXED WINDSHIELD LOUD SQUEAL AT 9:00 POSITION. WOULD NOT SEAL AT HIGHER CABIN DIFF PRESSURE.…
- 4 Sep 2023
Unknown, unknown
FLT#2851, FLL-UIO, 'FLIGHT ATTENDANTS COMPLAINED OF CHEMICAL ODOR IN FLIGHT, NOT DIRTY SOCK SMELL, CAPTAIN AND FIRST OFFICER DID NOT SMELL ODOR; COMPLIED WITH…
- 11 Feb 2023
Cids, failed
FLT#1464, SJD-LAX. (AIRCRAFT PERFORMED AN AIR TURN ABCK TO SJD) ' SHORTLY AFTER TAKE OFF WE HAD A FWD AND AFT CARGO SMOKE DET FAULT INDICATION( CIDS SYSTEM -…
- 24 Sep 2022
None, failed
FLT#225, JFK-TPA. 'BATTERY EMER EPSU 911WL TEST FAILED; REMOVED AND REPLACED PER AMM 33-51-38.'
- 24 Sep 2022
None, failed
FLT#225, JFK-TPA. 'BATT. EPSU FWD L (10WL) FAILED TEST; REMOVED AND REPLACED BATTERY EMER LIGHT PER AMM 33-51-38 OPS OK.'
- 22 Sep 2022
None, none
FLT#76, MSY-JFK. (AIRCRAFT DECLARED A EMERGENCY INTO JFK) 'ECAM G RSVR LO LVL. SO WE HAD A TOTAL LOSS OF GREEN SYS HYD. MANUAL GEAR EXTENDED; FOUND HI…
- 7 Aug 2022
Acm, dirty
FLT#788, SXM-JFK. 'DESCENDING THROUGH 7000 TO 5000 FEET STRONG MUSTY DIRTY SOCK SMELL DETECTED BY BOTH PILOTS. NO ODOR IN CABIN, ODOR WS COMING FROM COCKPIT…
- 11 Jun 2022
Cabin Air Sys, odor
FLT#579, DCA-FLL. 'OILY DIRTY SOCK SMELL NOTED IN COCKPIT. DESCENDING THUR 9000FT. NO APU. UPON OPENING THE COCKPIT DOOR STRONG OILY SMELL WAS NOTED IN THE…
- 26 Feb 2021
Control Servo, failed
FLT 1652, MCO-BOS. ECAM ""WHEEL N/W STRG FAULT"". IN FLIGHT OCCURRENCE, NO STEERING ON GROUND; PER AIRMAN REPORTS FOUND NOSE WHEEL STEERING SERVO CONTROL AT…
- 27 Jan 2021
Battery, no test
FLT # 824, MCO - DCA. EMERGENCY LIGHT BATTERY 10WL FAULTED. REMOVED AND REPLACED THE BATTERY OF THE EMERGENCY POWER SUPPLY UNIT 10WL, IAW AMM 33-51-38.…
- 27 Apr 2020
Slide, defective
DURING HEAVY MAINTENANCE, DOOR SLIDE LS DOOR CANNOT BE SAFTIED; REF AEROMAN NR 135443 WO 2020-133/1 PERFORMED OPERATIONAL CHECK DEPLOYMENT & REMOVED &…
- 14 Mar 2020
Battery, failed
FLT # 455, SWF-MCO. EPSU BATT 11WL & 12WL FAILED CAPACITY TEST; R & R EMERGENCY LIGHT BATTERY 11 WL & 12WL PER AMM 33-51-38 OPERATION CHECK NORMAL
- 14 Mar 2020
Battery, failed
FLT # 455, SWF-MCO. EPSU BATT 11WL & 12WL FAILED CAPACITY TEST; R & R EMERGENCY LIGHT BATTERY 11 WL & 12WL PER AMM 33-51-38 OPERATION CHECK NORMAL
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y765 BTWN FR 66-70 AT AFT GALLEY AREA; REPLACED FLOOR BEAM +Y765 BTWN FR 66-70 AT AFT GALLEY…
- 19 Dec 2018
Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON WEB FLOOR STRUCTURE BTWN FR 69-70 RH SIDE AT AFT GALLEY AREA; REPLACED WEB FLOOR STRUCTURE ATW FR 69-70…
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y919 BTWN FR 65-67 AT AFT GALLEY AREA; REPLACED FLOOR BEAM +Y919 BTWN FR 65-67 AT AFT GALLEY…
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM + Y 512 BTW FR 64 - FR 67 AFT GALLEY; REF N/R 2018-399743 REPLACED FLOOR BEAM + 512 BTW FR 64…
- 19 Dec 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK -Y 765 BTWN FR 21+7 AT AFT GALLEY; REPLACED SEAT TRACK - Y765 BTWN FR 12-24 AT FWD GALLEY…
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y765 BTWN FR 64-66 AT AFT GALLEY AREA; REPLACED FLOOR BEAM +Y765 BTWN FR 64-66 AT AFT GALLEY…
- 19 Dec 2018
Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON WEB FLOOR STRUCTURE BTWN FR 69-70 LH SIDE AT AFT GALLEY AREA; REPLACED WEB FLOOR STRUCTURE BTW FR69-70…
- 19 Dec 2018
Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SIL FR 66-FR 68 AT LEVEL STR 23L AT AFT GALLEY AREA; REPLACED LOWER SIL FR 66 AT LEVEL STR 23L AT…
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM - Y 1162.5 BTW 68 TO FR 69 AT AFT GALLEY AREA; REPLACED FLOOR BEAM -Y1162.5 BTW FR68 TO FR69…
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y765 BTW FR64 TO 66 AT AFT GALLEY AREA; REF N/R 2018-399740 - REPLACED FLOOR BEAM - Y765…
- 19 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y765 BTW FR66 - 70 AT AFT GALLEY AREA; REPLACED FLOOR BEAM - Y765 BTW FR66 - FR70 AT AFT…
- 19 Dec 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 34 -BTW STR 44 TO STR 43R IN FWD CARGO COMPARTMENT; REF N/R 2018-399811 - REPLACED SHEAR…
- 19 Dec 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CORROSION SHEAR TIE FR 33 BTWN STR 44-STR 43RIN FWD CARGO COMPT; REPLACED SHEAR TIE FR 33 BTWN STR…
- 19 Dec 2018
Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SIL FR 66-FR 68 AT LEVEL STR 23R AFT GALLEY AREA; REPLACED LOWER SIL FR 66-68 STR 44-STR 23R AT…
- 19 Dec 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 32 BTWN STR 437-42L IN FWD CARGO COMPARTMENT; REPLACED SHEAR TIE FR 32 BTWN STR 43L-42L IN…
- 19 Dec 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 33 BTW STR 43L-42L IN FWD CARGO COMPARTMENT; REPLACED SHEAR TIE FR 34 BTWN STR 43L-42L IN…
- 19 Dec 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 34 BTWN STR 43R-42R IN FWD CARGO COMPARTMENT; REPLACED SHEAR TIE FR 34 BTWN STR 43R-42R IN…
- 17 Jul 2017
Battery Pack, no test
EMERGENCY LIGHT FAILED TO TEST. R & R THE BATTERY PACK 13WL . EMERGENCY LIGHT TESTED OK IAW AMM 33-51-38.
- 15 Dec 2015
Fan, seized
VENT EXTRACT FAULT AT CRUISE ACCOMPANIED BY BURNING ODOR. FOUND EXTRACT FAN 18HQ SEIZED, R & R. OPS CHECK NORMAL.
- 8 Oct 2015
Line, leaking
FLIGHT RETURNED TO DEPARTURE DUE TO LOSS OF GREEN HYDRAULIC FLUID. R & R A HYD LINE TO LOCK ACTUATOR LT MLG HOSE IAW 32-11-22, NO LEAKS NOTED.
- 5 Sep 2013
Light, broken
ON MX CHECK FOUND EMERGENCY LIGHT AT LOWER RT SIDE OF THE L1 DOOR BROKEN. R & R LIGHT ASSY IAW AMM 33-50-00. OPS CHECKED GOOD.
- 17 Jun 2011
Coffeemaker, odor
FLT 485 BOS-LAX, SMELL OF SMOKE IN FWD GALLEY COMING FROM COFFEE POT 2 AFTER BEING TURNED ON FOR 3 MINUTES. NO VISIBLE SMOKE OF FLAME NOTED. COFFEE POT CB 2…
- 1 Apr 2011
Seal, defective
FLT 756 AUA-JFK, CREW DECLARED EMERGENCY AND A/C DIVERTED TO SDQ DUE TO VERY LOUD NOISE FROM FWD RIGHT ENTRY DOOR DURING CLIMB THRU FL 320. THIS WAS…