service difficulty reports
16 reports
- 7 Feb 2005
Angle, cracked
C-CHECK FINDING: PASSENGER DOOR AFT DRAG ANGLE CRACKED 2 INCHES LONG IN RADIUS JUST FWD OF PASSENGER DOOR ASSIST CABLE PULLEY MOUNT BRACKET.
- 7 Feb 2005
Intercostal, cracked
FS 484 AT RBL 36 & LBL 36 INTERCOSTALS CRACKED IN THE RADIUS.
- 7 Feb 2005
Intercostal, cracked
C-CHECK FINDING: FS 484 AT RBL 9 INTERCOSTAL CRACKED IN THE RADIUS.
- 7 Feb 2005
Sill, corroded
CARGO BAY FLOOR SILL AT FS 562.72 - 589 CORRODED.
- 18 Jan 2005
Smoke Detector, failed
LAV SMOKE INDICATION ON TAKEOFF. MX PERFORMED ENGINE RUNS AT T/O POWER WITH PACKS FULL HOT AND SLIGHTLY PRESSURIZED SEVERAL TIMES, NO LAV SMOKE INDICATIONS.…
- 4 Oct 2004
Flap, malfunctioned
A/C 705 HAD 2 FLAP FAIL ON OCT 4TH. FLAP FAIL AT 20 DEGREES AT 12NOON (RESET FECU, OPS CHK GOOD)FLAP FAIL AT 0 DEGREE AT 2PM (REMOVED AND REPLACED LT FLAP…
- 4 Jul 2004
Bulb, burned out
DURING INSPECTION A CEILING EMERGENCY LIGHT WAS FOUND INOPERATIVE. THE BULB WAS REPLACED AND A SATISFACTORY OPERATIONAL CHECK WAS PERFORMED. AIRCRAFT WAS…
- 15 Nov 2003
Light, inoperative
DURING INSPECTION THE FOWARD EMERGENCY ESCAPE PATH LIGHTING WAS FOUND INOPERATIVE. THE EMERGENCY PATH LIGHTING STRIP WAS IDENTIFIED AS THE CAUSE OF THE FAULT…
- 19 Aug 2003
Light, inoperative
DURING MAINTENANCE INSPECTION THE NR 4 CEILING EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE EMERGENCY LAMP. A…
- 30 Jun 2003
Light, inoperative
DURING MAINTENANCE INSPECTION, EMERGENCY FLOOR TRACK LIGHTING WAS INOPERATIVE FROM ROW 2 THRU 5. MAINTENANCE PERSONNEL REMOVED AND REPLACED EMERGENCY FLOOR…
- 8 Jun 2003
Connector, dirty
DURING MAINTENANCE INSPECTION, THE EMERGENCY FLOOR TRACK LIGHTS FROM SEAT ROW 2 TO 5 WERE FOUND TO BE DIM. MAINTENANCE PERSONNEL CLEANED THE CONNECTOR FOR THE…
- 20 May 2003
Light, inoperative
DURING MAINTENACE INSPECTION, FORWARD OVERHEAD EMERGENCY EXIT LIGHT WAS INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED EMERGENCY LIGHT, AN…
- 4 May 2003
Bulb, burned out
DURING MAINTENANCE INSPECTION, THE NR 3 CABIN CEILING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LAMP IN…
- 8 Apr 2003
Bulb, burned out
DURING MAINTENANCE INSPECTION, THE LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LAMP IN THE…
- 27 Dec 2002
Connector
During preflight inspection, the crew reported forward floor emergency light does not work. Maintenance personnel cleaned connector at first section off floor…
- 1 Nov 2002
Lamp