N69735
1974 Boeing 727-224 standard FAA →
earlier registrations
2 past records
- 1974
NTSB
- 12 Aug 1990
incident, Belgrade MT
service difficulty reports
85 reports
- 14 Aug 2007
Light, inoperative
NO FLIGHT: DURING A CHECK, FOUND L-1 EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT LIGHT. OPS CHECK NORMAL. AC WAS RETURNED TO…
- 26 Jul 2007
Servo, inoperative
ON DOWN WIND LEG TO LANDING WITH THE AUTO PILOT ON THE FLIGHT CREW TURNED THE YOKE LEFT AND RIGHT WITH NO MOVEMENT OF THE AIRCRAFT. A RATCHETING SOUND WAS…
- 11 Jul 2006
Frame, dented
NO FLIGHT: DURING INSPECTION THE FRAME AT STATION 380 WAS FOUND DENTED BETWEEN STRINGERS S5L AND S6L. REPAIRED FRAME WITH DOUBLER REPAIR IAW SRM. AIRCRAFT…
- 11 Jul 2006
Frame, dented
NO FLIGHT: DURING INSPECTIO THE FRAME AT STATION 400 WAS FOUND DENTED BETWEEN STRINGERS S6L AND S7L. REPAIRED FRAME WITH DOUBLER REPAIR SRM. AIRCRAFT RETURNED…
- 11 Jul 2006
Frame, dented
NO FLIGHT: DURING INSPECTION THE FRAME AT STATION 560 WAS FOUND DENTED BETWEEN STRINGERS S5R AND S6R. REPAIRED FRAME WITH DOUBLER REPAIR IAW SRM. AIRCRAFT…
- 11 Jul 2006
Frame, dented
NO FLIGHT: DURING INSPECTION THE FRAME AT STATION 600 WAS FOUND DENTED BETWEEN STRINGERS S6R AND S7R. REPAIRED FRAME WITH DOUBLER REPAIR SRM. AIRCRAFT…
- 16 Feb 2006
Turbine, failed
DURING TAKEOFF AFTER V- THE FLIGHT CREW FELT A DULL THUD ON AN ENGINE THE NR 1 ENGINE THEN FAILED. THE FLIGHT CREW DECLARED AN EMERGENCY AND RETURNED TO…
- 22 Dec 2005
Filter, bypassing
DURING CLIMB, OIL FILTER BYPASS LIGHT ILLUMINATED. RETARDING THROTTLE DID NOT EXTINGUISH. PERFORMED PRECAUTIONARY ENGINE SHUTDOWN IAW ABNORMAL PORCEDURES.…
- 22 Dec 2005
Oil Filter, bypassing
DURING CRUISE, DURING FLIGHT VIBRATION AND NOISE FOLLOWED BY OIL FILTER BYPASS LIGHT ON NR 3 ENGINE. NR 3 EINGINE SHUTDOWN AND ENGINE WINDMILLING PROCEDURE…
- 16 Nov 2005
Switch, out of adjust
DURING CLIMB FROM 14,000 FEET THE (MAIN CARGO DOOR NOT CLOSED) LIGHT ILLUMINATED. THE FLIGHT CREW DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. ON DECENT…
- 9 Jun 2004
Tube, broken
FLT 6007 - SEA-KTN - DURING DEPARTURE, ENGINE NR 2 N2 AT 102 PERCENT AND EGT AT RED LINE ON CLIMB-OUT, EPR AT 1.89. AIRCRAFT RETURNED. LANDING WEIGHT 142000,…
- 25 May 2004
Indicator, smoke
BOS - AFTER PUSH-BACK, FLIGHT CREW INDICATED SMOKE COMING FROM RADAR INDICATOR. REMOVED AND REPLACED RADAR INDICATOR. OPS CHECK AND SELF TEST GOOD ON GROUND.…
- 25 May 2004
Indicator, malfunctioned
AFTER PUSH-BACK, FLIGHT CREW INDICATED SMOKE COMING FROM RADAR INDICATOR. INSPECTED RADAR SYSTEM, FOUND BAD RADAR INDICATOR, TRANSFERRED TO DMI NR 1855 IAW…
- 4 Feb 2002
Skin, cracked
DURING B-CHECK INSPECTION MAINTENANCE, FOUND A 2.5 INCH CRACK TO THE NR 3 ENGINE NOSE COWL SKIN LOCATED AT NAC STATION 77.5. MAINTENANCE REMOVED AND REPLACED…
- 4 Dec 2001
Hydraulic Line, punctured
FLT 1925 - FWA-BNA - DURING CLIMB-OUT, THE CREW NOTICED THAT SYSTEM 'A' WAS LOSING HYDRAULIC FLUID. THE CREW RETURNED TO FWA, AND DECLARED AN EMERGENCY. AN…
- 23 May 2001
Switch, dirty
FLT 2011 - PDX-MHR - DURING APPROACH, THE GEAR WAS SELECTED TO THE DOWN POSITION. ALL THREE GREEN LIGHTS ILLUMINATED AND THE NOSE GEAR LIGHT WENT OUT AND DID…
- 23 Sep 2000
Warning System, activated
FLT 3771 - FWA-MCI - DURING CRUISE, THE APU FIRE BELL AND LIGHT CAME ON. PERFORMED CHECKLIST, DECLARED AN EMERGENCY, AND DIVERTED TO MLI. THE AIRCRAFT LANDED…
- 19 Jul 2000
Light, will not test
FOUND DURING PREFLIGHT, EMERGENCY EXIT LIGHT DOES NOT TEST AT ENTRY WAY DOOR. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT ASSEMBLY. PERFORMED A…
- 1 Feb 2000
Fire Detector, malfunctioned
MHR/LAX - FLT 2031 - DURING CRUISE, THE APU FIRE WARNING LIGHT ILLUMINATED. THE CREW PERFORMED ABNORMAL CHECK LIST AND DECLARED AN EMERGENCY AND RETURNED TO…
- 24 Nov 1999
Sense Line, disconnected
FLT 2027 - DEN-MHR - DURING TAKEOFF, THE NR 2 ENGINE FAILED AFTER TAKEOFF. THE CREW PERFORMED ABNORMAL CHECKLIST AND RETURNED TO DEN DECLARING AN EMERGENCY…
- 19 Oct 1998
Fitting, corroded
INSPECTION FOUND NR 4 FLAP TRACK ATTACH FITTING CORRODED. THE ATTACH FITTING WAS REMOVED AND REPLACED IAW ECRA 5740-01862 AND MM 32-11-51.
- 14 Oct 1998
Fitting, corroded
NLG TRUNNION CORRODED AND PITTED IN BORES LT AND RT. REMOVED CORROSION AND PITTING, FABRICATED AND INSTALLED NEW BUSHINGS PER SRM 53-40-1.
- 14 Oct 1998
Fitting, worn
RIGHT WING FORWARD SIDE OF MLG BEAM WING T/E PANEL TO BEAM ATTACH LINK FITTING HAS ELONGATED BOLT HOLES. REMOVED AND REPLACED FITTING PER SRM 51-30-1.
- 12 Oct 1998
Fairing, cracked
NR 6 FLAP TRACK MID FAIRING IS CRACKED .5 INCH LONG AT SKIN AFT EDGE. STOP DRILLED CRACK, HFEC INSP, FABRICATED TYPICAL REPAIR, DRILLED, DEBURRED,…
- 11 Oct 1998
Housing, corroded
LEFT SIDE AFT TRUNNION BEARING HOUSING IS PITTED. REMOVED AND REPLACED LT AFT BEARING HOUSING PER MM 32-11-0.
- 9 Oct 1998
Panel, cracked
RT WING 35 FLAP TRACK AFT INBD PANEL LEADING EDGE OF PANEL IS BENT AND TORN. BLEND OUT TORN AREA PER SRM 53-10 FIG 1 MAT LOSS .001.
- 9 Oct 1998
Angle, cracked
RT WING NR 5 FLAP FWD INBOARD FAIRING BRACKET CRACKED IN RADIUS .25 INCH LONG. FABRICATED ANGLE FROM 7075 T6 .063. LOCATED, DRILLED, DEBURRED, TREATED,…
- 9 Oct 1998
Fairing, cracked
NR 4 FLAP TRACK FAIRING AFT INBOARD ANGLE IS CRACKED .5 LONG. STOP DRILLED CRACK ON NR 4 FLAP TRACK FAIRING. FABRICATED REPAIR FROM 7075 T6 .050. LOCATED,…
- 8 Oct 1998
Fairing, cracked
INSPECTION FOUND A .25 INCH CRACK IN LT WING NR 4 FLAP TRACK FAIRING AT WS 124. A DOUBLER WAS INSTALLED IAW SRM 51-40-2, 51-10-2, MM 51-20-11.
- 7 Oct 1998
Fairing, cracked
INSPECTION FOUND A .25 INCH CRACK AT BOLT HOLE OF NR 5 FLAP TRACK CENTER FAIRING. A REPAIR WAS INSTALLED IAW SRM 51-40-2, 51-10-2, 51-40-2, 51-30-2, AND MM…
- 7 Aug 1998
Anti-Ice Duct, blown
THE FIRE WARNING BELL SOUNDED FOLLOWED BY ILLUMINATION OF THE NR 3 ENGINE FIRE WARNING LIGHT ON CLIMB-OUT OF IAH AT ABOUT 900 FEET. THE NR 3 ENGINE POWER WAS…
- 30 Jul 1998
Skin, cracked
INSPECTION FOUND A .5 INCH CRACK AT LEFT SIDE OF FUSELAGE AT CUTOUT FOR L-1 DOOR UPPER HINGE ARM. THE CRACKED AREA WAS CUT OUT. A DOUBLER REPAIR WAS…
- 20 Jul 1998
Angle, cracked
INSPECTION FOUND A .5 INCH CRACK IN FRAME ATTACH ANGLE INSIDE LT SIDE OF VERTICAL STABILIZER AT STRINGER 5L. THE CRACK WAS STOP DRILLED IAW SRM 51-10-1. A…
- 20 Jul 1998
Skin, cracked
INSPECTION FOUND A 2.75 INCH CRACK IN FUSELAGE SKIN AT L-1 DOOR LOWER HINGE CUTOUT. THE CRACKED AREA WAS CUT OUT, A REPAIR WAS FABRICATED AND INSTALLED IAW…
- 17 Jul 1998
Stringer, cracked
INSPECTION FOUND A 1.375 INCH CRACK IN RT WING VENT BOX STRINGER 19 AT WS 171.5, NR 2 TANK. THE CRACKED AREA WAS CUT OUT, A REPAIR DOUBLER, FILLER, AND ANGLE…
- 17 Jul 1998
Skin, cracked
INSPECTION FOUND A .75 INCH CRACK THROUGH FASTENER HOLE OF SKIN AT LT SIDE OF VERTICAL STABILIZER AROUND ACCESS PANEL 9523 ABOVE BS 1215. THE CRACK WAS STOP…
- 17 Jul 1998
Panel, cracked
INSPECTION FOUND CRACKS IN THE NLG WHEEL WELL TOP LEFT AND TOP RIGHT SKIN PANELS. THE CRACKS WERE .75 TO 1 INCH LONG. THE SKIN WAS REMOVED IAW SRM 51-10-1.…
- 17 Jul 1998
Skin, cracked
INSPECTION FOUND A 2.75 INCH CRACK IN LOWER AFT FUSELAGE SKIN CUTOUT AT R-1 DOOR. THE CRACK WAS STOP DRILLED, A DOUBLER AND TRIPLER WERE FABRICATED AND…
- 2 Jul 1998
Door, cracked
INSPECTION FOUND A 1.5 INCH CRACK IN AFT CARGO C-2 DOOR BOTTOM AFT CORNER. THE CORNER OF C-2 DOOR WAS REMOVED AND REPLACED IAW SRM 51-10-2.
- 2 Jul 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORROSION AT STA 328, LBL 30 AND 45, STA 344, STA 380, RBL 32 TO 42. THE CORRODED AREAS OF FLOORBEAM WERE CUT OUT. REPAIRS WERE…
- 2 Jul 1998
Web, cracked
INSPECTION FOUND STA 700 SUPPORT WEBS CRACKED AT S22L, S23L, S23R, AND S25R. THE CRACKS WERE 1 TO 1.5 INCH LONG. THE CRACKED AREAS WERE CUT OUT. REPAIR ANGLES…
- 2 Jul 1998
Floorbeam, corroded
INSPECTION FOUND FORWARD LAV FLOORBEAM AT STA 344, RBL 24 CORRODED. THE CORRODED AREA OF FLOORBEAM WAS REMOVED, A NEW FLOORBEAM SECTION WAS FABRICATED AND…
- 2 Jul 1998
Housing, cracked
INSPECTION FOUND A 1.5 INCH CRACK IN R-2 DOOR CUTOUT UPPER HINGE HOUSING. THE HINGE HOUSING WAS REMOVED IAW SRM 51-10-1. A NEW HOUSING WAS FABRICATED AND…
- 2 Jul 1998
Stringer, cracked
INSPECTION FOUND A 1.25 INCH CRACK IN STRINGER 15R AND A 2 INCH CRACK IN STRINGER 15L AT STA 720B. REPAIRS WERE FABRICATED AND INSTALLED IAW SRM 53-10-00,…
- 2 Jul 1998
Skin, corroded
INSPECTION FOUND FUSELAGE BELLY SKIN CORRODED AT BS 720 TO 720A, BL 0. A DOUBLER AND SHEAR TIE WERE FABRICATED AND INSTALLED IAW SRM 53-30-3, 53-30-4, AND…
- 2 Jul 1998
Frame, cracked
INSPECTION FOUND A .5 INCH CRACK IN FORWARD CARGO COMPARTMENT FRAME AT BS 680 BETWEEN STRINGER 23L AND 24L. THE CRACK WAS STOP DRILLED, A DOUBLER WAS…
- 2 Jul 1998
Seat Track, corroded
INSPECTION FOUND SEAT TRACK CORRODED BETWEEN STA 400 AND 420, RBL 48. THE CORRODED SECTION OF SEAT TRACK WAS REMOVED IAW SRM 51-30-2. A NEW SEAT TRACK WAS…
- 2 Jul 1998
Sidewall, cracked
THE NLG WHEEL WELL RIGHT SIDEWALL AND TOP CENTER PANEL HAD CRACKS MEASURING .5 TO 1 INCH LONG. THE CRACKED AREAS WERE CUT OUT, DOUBLERS WERE FABRICATED AND…
- 2 Jul 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 380 BETWEEN RBL 32 AND RBL 42. THE CORRODED AREA OF FLOORBEAM WAS CUT OUT IAW SRM 53-10-8. A REPAIR WAS FABRICATED…
- 2 Jul 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 303 TO 344, LBL 28. THE CORROSION WAS REMOVED IAW SRM 51-10-8. ANGLES WERE FABRICATED AND INSTALLED IAW SRM 51-40-8.
- 2 Jul 1998
Support, corroded
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 380 TO 400, RBL 16 AND STA 1150, RBL 18. THE FLOOR SUPPORTS WERE REMOVED, NEW FLOOR SUPPORTS WERE FABRICATED…
- 2 Jul 1998
Support, cracked
INSPECTION FOUND A 1 CRACK IN FLOORBEAM SUPPORT AT STA 400-420, BL 0. A 2 CRACK WAS FOUND IN FLOORBEAM SUPPORT AT STA 760, BL 0. THE FLOOR SUPPORT AT STA…
- 1 Jul 1998
Skin, torn
INSPECTION FOUND A 1 TEAR IN UPPER RUDDER RT SIDE TRAILING EDGE SKIN. THE TORN AREA WAS CUT OUT. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-2.
- 1 Jul 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 380, RBL 18. THE CORRODED AREA WAS CUT OUT IAW SRM 53-10-8. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8,…
- 1 Jul 1998
Bracket, cracked
INSPECTION FOUND A .75 INCH CRACK IN NR 5 LEADING EDGE FLAP INBOARD MOUNT BRACKET. THE BRACKET WAS REMOVED AND A NEW BRACKET WAS FABRICATED AND INSTALLED IAW…
- 1 Jul 1998
Seat Track, corroded
INSPECTION FOUND SEAT TRACK CORRODED AT STA 360, RBL 48. THE CORRODED SECTION OF SEAT TRACK WAS REMOVED AND REPLACED IAW SRM 51-10-1 AND 53-10-5.
- 1 Jul 1998
Angle, cracked
INSPECTION FOUND A CRACK IN AFT END OF LOWER ANGLE AT RT OUTBOARD MID-FLAP INBOARD END RIB. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS FABRICATED AND…
- 1 Jul 1998
Rib, cracked
INSPECTION FOUND A .375 INCH CRACK IN UPPER OUTBOARD FLANGE OF RT WING RIB AT WS 171.5, STRINGER 16. AN ANGLE REPAIR WAS FABRICATED AND INSTALLED IAW SRM…
- 8 May 1998
Hyd Line, leaking
DURING CLIMB, B-SYSTEM HYDRAULIC QUANTITY WENT TO ZERO. FOUND LEAKING HYDRAULIC LINE. REPLACED LINE.
- 12 Feb 1998
Splice Plate, cracked
INSPECTION FOUND A 2 INCH CRACK AT SPLICE PLATE INSIDE LEFT WING UPPER LEADING EDGE ABOVE NR 2 LEADING EDGE FLAP ACTUATOR/ANTI-ICE DUCT AREA, WS 224.5. THE…
- 12 Feb 1998
Rib, cracked
INSPECTION FOUND A 2 CRACK IN NR 2 LEADING EDGE SLAT RIB OUTBOARD OF ANTI-ICE DUCT. A REPAIR ANGLE WAS FABRICATED AND INSTALLED IAW SRM 57-50-3.
- 12 Feb 1998
Frame, corroded
INSPECTION FOUND C-3 DOOR FRAME CORRODED AT CUTOUT AT FORWARD LOWER END WHERE IT MEETS THRESHOLD AT BS 1090. THE CORRODED AREA WAS CUT OUT. A DOUBLER AND…
- 12 Feb 1998
Light, inoperative
INSPECTION FOUND THE RT AFT GALLEY DOOR EMERGENCY EXIT LIGHT TOO DIM. THE LIGHT ASSEMBLY WAS REPLACED IAW MM 33-50-101.
- 12 Feb 1998
Wire, broken
INSPECTION FOUND THE LEFT AND RIGHT FORWARD OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE AT CANNON PLUG. THE WIRE WAS REPAIRED…
- 12 Feb 1998
Skin, cracked
INSPECTION FOUND SEVERAL .375 INCH CRACKS FROM FASTENER HOLE AT NR 4 SLAT UPPER SKIN WHERE INBOARD HOOK MOUNTS. TWO .375 INCH CRACKS WERE FOUND AT NR 4 SLAT…
- 12 Feb 1998
Angle, cracked
INSPECTION FOUND A 3 INCH CRACK IN LT WING NR 2 SLAT CHORD ANGLE BELOW WHERE INBOARD STOP PAD MOUNTS. A NEW ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-01.
- 12 Feb 1998
Casting, cracked
INSPECTION FOUND A 1 INCH CRACK IN LT OUTBOARD FOREFLAP OUTBOARD END CASTING LOWER ATTACH LUG. THE LT OUTBOARD FOREFLAP VANE WAS REMOVED AND REPLACED IAW MM…
- 12 Feb 1998
Skin, cracked
INSPECTION FOUND A 1.375 CRACK IN LT WING NR 4 SPOILER AT LOWER SKIN JUST INBOARD OF SECOND FROM INBOARD HINGE. THE NR 4 SPOILER WAS REMOVED AND REPLACED.
- 12 Feb 1998
Skin, debonded
INSPECTION FOUND LT INBOARD FOREFLAP INBOARD TRAILING EDGE SKIN DEBONDED WITH CHAFE MARKS ALONG UPPER SURFACE. THE FOREFLAP WAS REMOVED, REPAIRED AND REPLACED.
- 12 Feb 1998
Doubler, cracked
INSPECTION FOUND A 2 INCH CRACK IN DOUBLER OF RT WINGTIP TRAILING EDGE AT WBL 626. THE WINGTIP WAS REMOVED AND A NEW DOUBLER WAS FABRICATED AND INSTALLED IAW…
- 12 Feb 1998
Rib, cracked
INSPECTION FOUND A 1.5 CRACK IN WINGTIP MOUNT RIB AT WINGTIP AREA AFT OF NAV STROBE LIGHT. AN ANGLE DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-3.
- 12 Feb 1998
Skin, cracked
INSPECTION FOUND A .625 INCH CRACK AND TWO SHEARED FASTENERS IN LEFT WINGTIP LOWER TRAILING EDGE SKIN. THE FASTENERS WERE REMOVED AND THE CRACK WAS STOP…
- 29 Nov 1996
Channel, corroded
INSPECTION FOUND FORWARD CARGO BAY SIDEWALL FLOOR SUPPORT CHANNEL CORRODED AT BS 540, STRINGER 27R. A FLOOR SUPPORT CHANNEL WAS FABRICATED AND INSTALLED IAW…
- 29 Nov 1996
Support, corroded
INSPECTION FOUND FORWARD CARGO BAY FLOOR SUPPORT TRACK CORRODED AT BS 640, STRINGER 28L. A FLOOR SUPPORT TRACK WAS FABRICATED AND INSTALLED IAW SRM 53-10-2,…
- 23 Nov 1996
Stringer, corroded
INSPECTION FOUND STRINGER 28L CORRODED AT BS 520. A STRINGER AND SPLICE REPAIR WAS INSTALLED IAW SRM 53-10-3, FIGURE 1.
- 22 Nov 1996
Floor, corroded
INSPECTION FOUND NR 2 GALLEY UPPER COMPARTMENT FLOOR CORRODED. THE CORROSION WAS REMOVED, TWO DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 51-40-2 AND…
- 20 Jul 1996
Pack, smoking
WHILE OPERATING RT PACK IN MANUAL WITH MIX VALVE AT HALF POSITION, THE RIGHT PACK TEMP WENT TO 150 DEGREES AND WAS ACCOMPANIED BY CABIN SMOKE DURING DESCENT…
- 8 Jan 1995
Transmission, inoperative
IAH - FLT 0414 - THE OUTBOARD FLAPS HAD A HISTORY OF NOT EXTENDING BOTH ON THE GROUND AND IN-FLIGHT. MAINTENANCE FOUND EXCESSIVE SHAFT PLAY IN THE NR 8 FLAP…
- 21 Dec 1994
Support, corroded
GSO - INSPECTION FOUND CORROSION ON FLOOR BOARD SUPPORT AT STA 1034, LBL 27-45. THE CORROSION WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-10-2 AND…
- 21 Dec 1994
Floor Beam, corroded
GSO - INSPECTION FOUND TOP CHORD OF STA 1130 FLOOR BEAM CORRODED BETWEEN SEAT TRACKS 4 AND 5. THE CORROSION WAS REMOVED AND A REPAIR DOUBLER WAS INSTALLED IAW…
- 21 Dec 1994
Floor Board, cracked
GSO - INSPECTION FOUND MAIN CABIN FLOOR BOARD NR 58 CRACKED IN HALF. A NEW FLOOR BOARD PANEL WAS FABRICATED AND INSTALLED IAW SRM 53-20-1 AND SRM 51-30-2. (X)
- 21 Dec 1994
Floor Beam, corroded
GSO - INSPECTION FOUND CORROSION ON FLOOR BEAM AT STA 1139, RBL 29 - RBL 55. THE CORROSION WAS REMOVED AND A NEW FLOORBEAM WAS INSTALLED IAW SRM 51-20-2 AND…
- 21 Dec 1994
Support, corroded
GSO - INSPECTION FOUND CORROSION ON FLOOR BEAM SUPPORT AT STA 1067, LBL 43-46. REMOVED CORRODED SUPPORT, FABRICATED NEW FLOOR BEAM AND INSTALLED IAW SRM…
- 21 Dec 1994
Intercostal, cracked
GSO - INSPECTION FOUND A 1 INCH CRACK IN INTERCOSTAL AT STA 720-740, BL 0. AN ANGLE FOR THE INTERCOSTAL WAS FABRICATEDAND INSTALLED IAW SRM 53-10-2 AND SRM…
- 21 Dec 1994
Skin, cracked
GSO - INSPECTION FOUND A .50 INCH CRACK IN MAIN CABIN ENTRANCE L-1 DOOR INSIDE WEB SKIN. A DOUBLER WAS FABRICATED FOR THE MAIN CABIN ENTRANCE DOOR INSIDE WEB…