N684JW
2004 Embraer EMB-145LR standard FAA →
registration
- 2004
service difficulty reports
130 reports
- 15 Jul 2026
Unknown, odor
SMOKE ODOR IN COCKPIT, NOT DETECTED BY FLIGHT ATTENDANT. ( CAPTAIN SAID IT HAD AN ODOR OF BURNED GRASS ). RAN BOTH PACKS INDIVIDUALLY AND RAN BOTH EIGNES ON…
- 13 Feb 2026
Ballast, abnormal
RIGHT AFT EXTERNAL EMERGENCY LIGHT INOPERATIVE. R & R AFT EXTERNAL EMERGENCY LIGHT RT BALLAST IAW AMM 33-50-10-000/400-801-A, OPS CHECK PERFORMED WITH NO…
- 10 Jan 2026
Dau, none
DAU 2 FAIL DISPLYED DISPLAYED SEVERAL TIMES MOMENTARILY WITH BURNING ODOR FOR ABOUT 10 MINUTES, SMELL WAS ELECTRICAL IN NATURE. R&R DAU NR 2 IAW AMM…
- 20 Nov 2025
Steering Sys, out of adjust
DURING TAKE OFF ROLL ATTEMPT NWS VEERS LEFT WITHOUT TILLER ENGAGEMENT UNDER 30 KIAS. TAKE OFF REJECTED. PERFORMED TAXI CHECKS, NO DEFECTS NOTED. INSP STEERING…
- 18 Feb 2025
Pressure Switch, faulted
DURING CLIMBOUT APPOX 210 KNTS AT 2K FT EXPERIENCE YAW DAMPNER FAIL FOLLOWED BY RUDDER 1/2 FAIL FOLLOWED QRH WITH RUD SYS 2 DEACTIVATED FACT 18FEB25 16:14 CLT…
- 8 Jan 2025
Cap, corroded
F018677 NLG RH MAIN STRUT BEARING CAP IS CORRODED. RAR NLG RH MAIN STRUT BEARING CAP IAW EMB 145 AMM 32-20-01
- 30 Dec 2024
Floor Support, corroded
F016973 CORROSION ON LH OTBD #3 FLOOR SILL. RAR L/H OTBD #3 FLOOR SILL IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Gusset, corroded
F016938 CORROSION ON LH BEAM # 6 GUSSET. REMOVED AND REPLACED LH BEAM # 6 GUSSET IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Floor Support, corroded
F016960 CORROSION ON LH OTBD #4 FLOOR SILL. RAR L/H OUTBD #4 FLOOR SILL IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Gusset, corroded
F016961 CORROSION ON LH BEAM #5 GUSSET. REMOVED AND REPLACED LH BEAM #5 GUSSET IAW EMB145 SRM 51-40-02
- 30 Dec 2024
Floor Support, corroded
F016968 CORROSION ON LH OTBD #2 FLOOR SILL. RAR LH OTBD #2 FLOOR SILL IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Floor Support, corroded
F016970 CORROSION ON RH OTBD #2 FLOOR SILL. RAR RH OTBD #2 FLOOR SILL IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Floor Support, corroded
F016973 CORROSION ON LH OTBD #3 FLOOR SILL. RAR L/H OTBD #3 FLOOR SILL IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Gusset, corroded
F016974 CORROSION ON LH BEAM #3 GUSSET. RAR ON LH BEAM #3 GUSSET IAW EMB- 145 SRM 51-40-02.
- 30 Dec 2024
Gusset, corroded
F016979 CORROSION ON CENTER BEAM #3 GUSSET. RAR CENTER BEAM GUSSET #3 IAW EMB 145 SRM 51-40-02.
- 30 Dec 2024
Crossbeam, corroded
F0016903 GALLEY, AT FR20, THE CENTER AISLE CROSSBEAM IS HEAVILY CORRODED AT MULTIPLE LOCATIONS. RAR CENTER AISLE CROSSBEAM AT FR 20 IAW EMB 145 SRM 51-40-02.
- 30 Dec 2024
Floor Support, corroded
F016905 GALLEY, AT FR19, THERE IS CORROSION ON THE RH FLOOR SILL. REMOVED AND REPLACED RH FLOOR SILL AT FR19 IAW EMB 145 SRM 51-40-02.
- 30 Dec 2024
Crossbeam, corroded
F016907 GALLEY, AT FR20, THERE IS CORROSION ON THE RH CROSSBEAM GUSSET. RAR DIAMOND GUSSET RH FR 20 IAW EMB 145 SRM 51-40-02
- 30 Dec 2024
Crossbeam, corroded
F016913 GALLEY, AT FR23, THERE IS CORROSION ON THE RH CROSSBEAM. REMOVED AND REPLACED CROSSBEAM (ANGLE) IN GALLEY AT FR23 IAW EMB145 SRM 51-40-02
- 29 Dec 2024
Floor Support, corroded
F016862 LH FLOOR SILL #7 CORRODED. RAR THE LH FLOOR SILL #7 IAW EMB 145 SRM 51-40-02.
- 29 Dec 2024
Floorbeam, corroded
F016865 CENTER FLOOR BEAM LAVATORY FLOOR GUSSET CORRODED. REMOVED AND REPLACED CENTER FLOOR BEAM LAVATORY FLOOR GUSSET IAW EMB 145 SRM 51-40-02
- 29 Dec 2024
Floorbeam, corroded
F016866 RH FLOOR BEAM LAVATORY FLOOR GUSSET CORRODED. REMOVED AND REPLACED RH FLOOR BEAM LAVATORY FLOOR GUSSET IAW EMB 145 SRM 51-40-02
- 20 Jul 2022
Door, dirty
MAIN CABIN DOOR HARD TO OPEN-C/A-CLEANED & LUBRICATED MAIN DOOR ROLLERS AW MM 53-21-02, OPS CHECK GOOD IAW MM 52-00-00
- 22 Jun 2022
Door, dirty
MAIN CABIN DOOR DIFFICULT TO OPEN-C/A-LUBRICATED ROLLERS ON MAIN CABIN DOOR IAW AMM 52-18-00 OPS CHECK GOOD
- 10 Jun 2022
Lamp, inoperative
SUPPLEMENTAL CA FOR RH AFT OVER WING EMERGENCY LIGHT INOP. "TRANSFERRED FROM NRWC 684-SGF-05021 ITEM 1"-C/A-REMOVED AND REPLACED RH AFT OVER WING EMERGENCY…
- 29 May 2022
Lamp, inoperative
RH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPC GOOD. END.
- 26 Apr 2022
Lamp, inoperative
RH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.
- 22 Apr 2022
None, broken
AFT CABIN EMERGENCY FLASHLIGHT CLIP BROKEN-C/A-RAR AFT CABIN EMERGENCY FLASHLIGHT CLIP IAW ASTRONICS CMM 25-60-14 OPC GOOD
- 10 Sep 2021
Light, inoperative
MEL 33-22 AUTH# 090117D-C REF LOGPAGE 4798868-2 "SERVICE DOOR EXTERNAL EMERGENCY LIGHT INOP". REMOVED AND REPLACED SERVICE DOOR EXTERNAL EMERGENCY LIGHT…
- 9 Sep 2021
Light, inoperative
SERVICE DOOR EXTERNAL EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A . NO FIX. NEEDS NEW…
- 7 Jun 2021
Flashlight, inoperative
AFT FA EMERGENCY FLASHLIGHT INOP. R & R AFT FA'S FLASH LIGHT IAW EMB 145 AMM 33-50-16. OPERATIONAL CHECK GOOD.MEL RESTORED.
- 8 May 2021
Lamp, inoperative
SERVICE DOOR CIELING EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR CEILING EMERGENCY LIGHT LAMP IN REF WITH EMB 145 AMM 33-50-09.
- 25 Apr 2021
Light, incorrect
REFERENCE AML#4406520 ITEM 1. EMERGENCY LIGHT FLOOR PROXMITY STRAP EXIT LOCATOR AMBER LIGHT INCORRECTLY.-C/A-RAR EMERGENCY LIGHT FLOOR PROXIMITY STRAP IAW EMB…
- 18 Apr 2021
Light, inoperative
LH CENTER FAIRING EXTERNAL EMERGENCY LIGHT INOP.-C/A-RAR LH CENTER FAIRING EXTERNAL EMERGENCY LIGHTIAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.
- 14 Mar 2021
Lamp, inoperative
RH EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR RH EXTERIOR EMERGENCY LAMP IAW AMM 33-50-10 OPC GOOD
- 10 Jan 2021
Cradle, broken
REAR EMERGENCY FLASH LIGHT HAS BROKEN HOLDER. C/A: R & R REAR EMERGENCY FLASH LIGHT, IAW PS2 WC.
- 14 Dec 2020
Light, inoperative
MEL 3330-AUTH NR 120137-C 4688475/2 EMERGENCY LIGHT FLOOR STRIP NR 4 INOPERABLE. C/A: R & R FLOOR LIGHT STRIP NR 4, IAW AMM 33-50-12. OPERATIONS CHECK GOOD.…
- 12 Dec 2020
Connector, damaged
EMERGENCY LIGHTING FLOOR STRIP NR 4 HAS DAMAGED CONNECTORS. C/A: DEFFERED PER MEL 33-30.
- 29 Nov 2020
Charger, not reported
NR 2 EMERGENCY BATTERY POWER SUPPLY CHARGER AND BATTERY PACK REQUIRE REPLACEMENT. C/A: R & R NR 2 EMERGENCY BATTERY POWER SUPPLY CHARGER AND BATTERY PACK, IAW…
- 29 Nov 2020
Lamp, inoperative
RT FWD WING EMERGENCY LIGHT INOPERABLE. C/A: REMOVED AND REPLACED RT FWD EXTERNAL EMERGENCY LIGHT LAMP, IAW EMB145 AMM 33-50-10. OPERATIONS CHECK GOOD.
- 22 Jul 2020
Handset, malfunctioned
PILOT EMERGENCY LIGHT ILLUMINATED ON FA FWD INTERPHONE AND AFT PANEL. R & R FWD FLIGHT ATTENDANT'S HANDSET IAW AMM 23-31-03. OPS CHECKED SATISFACTORY.
- 21 May 2020
Light, inoperative
FOUND LAST FLOOR PROXIMITY STRIP LIGHT OUT. REMOVED AND REPLACED LAST FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12 OPS CHECKED GOOD
- 2 Mar 2020
Doubler, scratched
MAIN DOOR EXTERIOR AFT LOWER EDGE REPAIR DOUBLER IS SCRATCHED-C/A-BLENDED DAMAGE AND FOUND TO BE OUT OF LIMITS IAW EMB 145 SRM 51-10-03. REMOVED AND REPLACED…
- 25 Feb 2020
Door Frame, corroded
SSI 53-20-10 SERVICE DOOR CUTOUT AFT FRAME 22 IS CORRODED AROUND LOWER NUTPLATE HOLE-C/A-PERMFORMED PERMANENT REPAIR TO SERVICE DOOR CUTOUT AFT FRAME 22…
- 25 Feb 2020
Skin, chafed
FUSELAGE SKIN IS CHAFFED INSIDE RH PYLON PANEL 424DB -C/A-PERFORMED PERMANENT REPAIR TO CHAFED FUSELAGE SKIN INSIDE RH PYLON PANEL 424DB IAW ERS-EM-53MR-4053…
- 25 Feb 2020
Floor Support, corroded
SSI 53-20-00 CABIN LH OMEGA BEAM SIDE AT FRAME 29 AT CROSSMEMBER IS CORRODED.-C/A-PERFORMED PERMANENT REPAIR TO LH OMEGA BEAM SIDE AT FRAME 29 AT CROSSMEMBER…
- 23 Feb 2020
Shear Tie, corroded
SSI 53-30-03: FRAME 65 SHEAR CLIP CORRODED AT LOWER END OF CARGO DOOR OPENING-C/A-BLENDED CORROSION ON FRAME 65 SHEAR CLIP IAW EMB 145 SRM 51-10-03. FOUND TO…
- 22 Feb 2020
Stanchion, cracked
LH OMEGA BEAM STANCHION AT FRAME 29 IS CRACKED-C/A-REMOVED AND REPLACED LH OMEGA BEAM STANCHION AT FRAME 29 IAW EMB 145 SRM 51-40-02. INSTALLED STANCHION P/N…
- 22 Feb 2020
Channel, corroded
GALLEY SERVICE DOOR CENTER SILL HAS CORROSION AT MULTIPLE LOCATIONS.-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.
- 22 Feb 2020
Door Frame, corroded
SSI 53-30-48: CARGO DOOR CUTOUT LWR STRUCTURE CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW EMB 145 SRM 51-40-02, SRM 51-40-06 AND SRM…
- 22 Feb 2020
Fairing, corroded
CARGO DOOR SCREW HOLES FOR FAIRINGS HAVE CORROSION-C/A-PERFORMED BLEND OUT OF CORROSION ON CARGO DOOR FAIRING SCREW HOLES IAW EMB 145 SRM 51-10-03. SCREW…
- 18 Feb 2020
Fitting, cracked
DURING HMBV INSPECTION, QC FOUND LH PYLON FWD LOWER YOKE FITTING CRACKED.-C/A-REMOVED AND REPLACED YOKE FITTING IAW ERS-EM-54MR-698.
- 4 Feb 2020
Wire, broken
EMERGENCY EXIT LIGHT ON COCKPIT STEP PNL HAS A BROKEN WIRE-C/A-COMPLETE:REMOVED AND REPLACED EMERGENCY EXIT LIGHT ON COCKPIT STEP PNL IAW EMB 145 AMM…
- 4 Feb 2020
Wire, broken
2EA PROX LIGHT WITH ARROWS, 1EA SERVICE DOOR EXIT PROX LIGHT, AND 1EA PROX LIGHT WITHOUT ARROWS HAVE BROKEN WIRES-C/A-COMPLETE:REMOVED AND REPLACED 2EA PROX…
- 4 Feb 2020
Escape Rope, frayed
COPILOT AND PILOTS EMERGENCY ESCAPE ROPE FRAYED-C/A-COMPLETE:REMOVED AND REPLACED COPILOT AND PILOTS EMERGENCY ESCAPE ROPE IAW EMB145 AMM 25-60-07, 20-10-01,…
- 4 Feb 2020
Battery, discharged
EMERGENCY LIGHT ON MAIN ENTRY WAY INOP-C/A-COMPLETE:REMOVED AND REPLACED BATTERY SUPPLY #1 IAW EMB 145 AMM 33-50-04. OPC GOOD.
- 4 Feb 2020
Wire Splice, broken
AFT FLASHLIGHT CHARGER ON LAV TOILET WALL SPLICE BROKEN AND BROKEN ON THE OPPOSITE SIDE ON THE LAV CEILING.-C/A-COMPLETE:REPAIRED WIRE TO SPLICE SP3557 IAW…
- 4 Feb 2020
Wire, damaged
EMERGENCY LIGHT STRIP WIRE AT FR 45 ON AIRCRAFT SIDE IS DAMAGED-C/A-COMPLETE:UPON FURTHER INVESTIGATION BROKEN EMERGENCY LIGHT STRIP WIRE AT FR49 TO BE…
- 4 Feb 2020
Holder, cracked
4EA PROX LIGHT HOLDER AND 4EA RH SIDEWALLS ARE CRACKED-C/A-COMPLETE:REMOVED AND REPLACED 4EA PROX LIGHT HOLDER AND 4EA RH SIDEWALLS IAW EMB 145 AMM 33-50-12…
- 4 Feb 2020
Wire, broken
EMERGENCY LIGHT STRIP WIRE FOR #1 LIGHT STRIP HAS BROKEN WIRE AT PIN ON AIRCRAFT SIDE-C/A-COMPLETE:RE TERMINATED EMERGENCY LIGHT STRIP #1 LIGHT STRIP WIRE AT…
- 21 Jan 2020
Warning Message, illuminated
FLAP LOW SPEED ADVISORY ON APPROACH-C/A-DEFERRED FLAP LOW SPEED, CH-2. M PROCEDURES C/WED.CMC MSG "FLAP L/H MOTOR BRAKE FAIL"MEL AUTH# 010786DM-B REF# 27-9
- 17 Nov 2019
Warning Message, illuminated
FLAP LOW SPEED ON FINAL APPROACH-C/A-DEFERRED FLAP CHANNEL #2. "M" PROCEDURES C/W. CMC MESSAGE "FLAP LH MOTOR BRAKE FAIL".
- 8 Oct 2019
Display, failed
FO PFD INOP ELECTRICAL BURN SMELL. SOURCE OF ODOR FOUND AND CORRECTED. INSTALLED NR 2 PFD IAW MM 34-22-01. OPS CK GOOD IAW EMB MM 34-22-00. GROUND RAN…
- 2 Oct 2019
Sign, unsecure
EXIT SIGN AT 1A UNSECURE. SECURED THE EXIT SIGN AT 1A IAW AMM 25-60-00.
- 25 Sep 2019
Light, burned
VISIBLE SMOKE AND ASSOCIATIED ELECTRICAL BURNING SMELL EMINATING FROM CAPTAINS YOKE, FLOOR AREA. INTERNAL APU POWER WAS SUPPYING ELECTRICAL LOADS. EVENT…
- 26 Aug 2019
O-Ring, failed
BLEED 2 LEAK AFTER AUDIBLE POP SOUND. REMOVED AND REPLACED O-RINGS AND COUPLING COVER AT BLEED COUPLING #8 IAW AMM 36-11-10. BLEED 2 LEAK CHECK GOOD IAW AMM…
- 28 Jul 2019
Light, inoperative
CEILING EMERGENCY LIGHT AT ROW 17 INOP. C/A-REMOVED AND REPLACED CEILING EMERGENCY LIGHT LAMP AT ROW 17 IAW AMM 33-50-08 OPC GOOD.
- 8 Jun 2019
Fan, failed
SMELL OF RUBBERY SMOKE AT FL 260 ALL COCKPIT INDICATIONS IN COCKPIT WERE NORMAL AOM PERFORMED AND DIVERTED AS REQUIRED.-C/A-INSPECTED GALLEY AND CABIN BALLETS…
- 20 Apr 2019
Light, inoperative
EMERGENCY LIGHT BETWEEN ROW 7 & 9 INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT STRIP FROM ROW 7 8 9 PER 33-50-12 OPS CK GOOD
- 6 Nov 2018
Coupling, detached
BLEED 1 LEAK ON CLIMB OUT. REATTACHED HOSE COUPLING AT ACM NR 1 IAW MM CH 21-51-04.
- 4 Nov 2018
Sleeve, damaged
BLEED 1 LEAK CLIMBING OUT OF 6,000 AND CABIN ALT CONTINUED TO CLIMB. REMOVED PACK 1 PANEL IAW 06-41-01 OF AMM. PERFORMED GVI OF PACK 1 FOUND COUPLER ABOVE ACM…
- 7 Oct 2018
Duct, leaking
BLD 1 LEAK DURING CLIMBOUT, EPC C/W. -C/A-PERFORMED REMOVED AND REPLACED OF DUAL TEMP CONTROL VALVE Y-DUCT IAW AMM 21-60-01. LEAK CHECK GOOD.
- 4 Jul 2018
Light, inoperative
CEILING EMERGENCY LT AT ROW 17 INOP. R&R AISLE EMERGENCY LIGHT LAMP AT ROW 17 IAW AMM TASK 33-50-08-000-801-A AND 33-50-08-400-801-A, OPS CHECK GOOD AT THIS…
- 15 May 2018
Bulb, inoperative
RIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-50-07. OPS CHECKED GOOD IAW AMM 33-50-00.
- 20 Mar 2018
Light, inoperative
MAIN DOOR EXTERNAL EMERGENCY LIGHT INOP.-C/A-REMOVED AND REPLACED MAIN DOOR EXTERNAL EMERGENCY LIGHT LAMP. OPS CHECKED GOOD IAW AMM 33-50-10
- 3 Dec 2017
Flashlight, not reported
AFT CABIN EMERGENCY FLASHLIGHT NEEDS TO BE REPLACED-C/A-REMOVED AND REPLACED EMERGENCY FLASHLIGHT AS REQUIRED, NO OTHER DEFECTS NOTED AT THIS TIME.
- 14 Nov 2017
Strap, damaged
TEAR STRAP DAMAGED AT FRAME 22L BETWEEN STR 13L AND 14L. MAJOR REPAIR, PERFORMED REPAIR DAMAGED TEAR STRAP AT FRAME 22 BETWEEN STR 13L AND 14L IAW…
- 23 Oct 2017
Skin, cracked
SKIN CRACK AROUND RIVET AT FR75 BTW STGRS 2R-3R. REPAIRED SKIN CRACK AROUND RIVET AT FR 75 BTW STGRS 2R-3R IAW SRM 53-31-01 ITEM 11 FIG 219.
- 23 Oct 2017
Skin, cracked
LT AFT FUSELAGE FR75 HAS SKIN CRACK ABOVE STR 2L. REPAIRED LT AFT FUSELAGE FR 75 SKIN CRACK ABOVE STR 2L IAW SRM 53-31-01 ITEM 11 FIG 219.
- 19 Oct 2017
Skin, corroded
CORROSION ON INTERNAL SKIN FR 60-61 STR 20L-21L. REMOVED AND INSTALLED SERVICEABLE INT FUSELAGE REINFORCEMENT PLATE BTW FR 60-61 STR 20L-21L IAW SRM 51-40-02.
- 7 Oct 2017
Power Supply, inoperative
PAX DOOR EMERGECY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE NR 1 POWER SUPPLY IAW AMM 33-50-04, OPS CHECKED GOOD.
- 7 Oct 2017
Power Supply, inoperative
EMERGENCY LIGHT FLOOR ROWS 6 - 8 INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-50-04.
- 26 Aug 2017
Bleed Valve, faulty
DURING TAKEOFF E2 ATTCS NO MARGIN WARNING MSG. ABORT AT 90 KTS. AFTER ABORT E 2 EXCEEDANCE CAUTION MSG. OUTSIDE AIR TEMP, ATIS AND REF TO TEMP ALL 31C MAX ITT…
- 5 Apr 2015
Wire, broken
NUMBER 6 EMER LIGHT STRIP HAS BROKEN WIRE. REPAIRED WIRE ON NR 6 EMER LIGHT STRIP IAW SWPM 20-21-00.
- 3 Apr 2015
Connector, broken
EMERGENCY LIGHT STRIP HARNESS HAS BROKEN CONNECTOR AT FLOOR PANEL 251FF. R & R THE EMER LIGHT STRIP HARNESS CONNECTOR AT FLOOR PANEL 251FF SP9211 IAW SWPM…
- 3 Apr 2015
Skin, chafed
FUSELAGE SKIN CHAFED INSIDE PANEL 414DB. PERFORMED REPAIR IAW ERS-EM-53MR-1206.
- 2 Apr 2015
Epsu, unknown
REPLACE EPSU 4. R & R EPSU 4 IAW MNTC WC 33-700-19.
- 2 Apr 2015
Epsu, unknown
R & R EPSU 1 IAW MNTC WC 33-700-19.
- 2 Apr 2015
Epsu, unknown
REPLACE EPSU 2. R & R EPSU 2 IAW MNTC WC 33-700-19.
- 2 Apr 2015
Epsu, unknown
REPLACE EPSU 3. R & R EMER EPSU 3 IAW MNTC WC 33-700-19.
- 31 Mar 2015
Structure, corroded
SERVICE DOOR CUT OUT STRUCTURE HAS SURFACE CORROSION AT LOWER FWD NUTPLATE HOLE. PERFORMED ERS-EM-52MR-1186 FOUND TO BE ACCEPTED AS IS.
- 16 Mar 2015
Structure, corroded
CARGO DOOR LOWER INBD EDGE MEMBER NUTPLATE HOLES ARE CORRODED. REMOVED CORROSION FROM CARGO DOOR LOWER INBD EDGE MEMBER NUTPLATE HOLES & FOUND TO BE ACCEPTED…
- 22 Dec 2014
Tire, worn
ON SHORT FINAL, NOSE GEAR WAS MAKING A THUMPING SOUND. EXECUTED GO AROUND, CYCLED LG, & HEARD SAME THUMPING SOUND. APPROX 15 - 20 THUMPS IN 15 MINUTES. BOTH…
- 13 Nov 2014
Pump, leaking
HYD 2 LOW QTY ON EICAS. SERVICED NR 2 HYDR RESERVOIR IAW EMB 145MM 12-13-01. TROUBLESHOOTING ITEM 1 ABOVE. FOUND NR 2 EDP TO BE LEAKING. REPLACED NR 2 EDP IAW…
- 11 Nov 2014
Light, inoperative
PARKING BRAKE LIGHT IS INOPERATIVE. R & R BRAKE LIGHT BULBS IAW AMM 20-13-04.
- 30 Nov 2013
Sign, unsecure
OVERHEAD EXIT SIGN IN CEILING FALLING DOWN 12A. SECURED CTR AISLE EXIT SIGN AT ROW 12 IAW STANDARD MTX PRACTICES.
- 5 Nov 2013
Light, inoperative
FLOOR PROXIMITY LIGHT STRIP AT SEAT 6 IS INOPERATIVE. R & R LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD. NO FURTHER DEFECTS.
- 27 Aug 2013
Flashlight, inoperative
CAPTAIN`S FLASHLIGHT MUST BE SHAKEN TO WORK. R & R FLASHLIGHT IAW AMM 33-21-06. FLASHLIGHT OPS CHECKED GOOD.
- 8 Aug 2013
Wire, broken
NR 1 EMERGENCY LIGHT HAS BROKEN WIRES. R & R LIGHT IAW AMM 33-50-12, OPS CHECKED GOOD.
- 1 Aug 2013
Inverter, inoperative
EMERGENCY LIGHT ON AFT WALL OF GALLEY IS INOPERATIVE. R & R NR 3 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD IAW AE W/C 33-700-17.
- 24 Apr 2013
Unknown, malfunctioned
ON FLIGHT 3588 THE CREW REPORTED AN INTERMITTENT "BRAKE ON" INDICATION INFLIGHT. EMERG/PARK BRAKE LEVER WAS IN RELEASED POSITION. THE CREW DECLARED AN…
- 5 Apr 2013
Flashlight, missing
DURING B INSPECTION FOUND THE PILOTS EMERGENCY FLASHLIGHT MISSING. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FLASHLIGHT AND CRADDLE IAW…
- 2 Apr 2013
Flashlight, malfunctioned
ON FLIGHT 3585 THE CREW REPORTED THE FLIGHT ATTENDANT FLASHLIGHT ABOVE JUMP SEAT APPEARS TO NOT BE CHARGING BECAUSE THE RED LIGHT IS NOT ILLUMINATED. THE…
- 8 Mar 2013
Sign, inoperative
DURING B INSPECTION FOUND THE AFT GALLEY SEAT 3BC EMERGENCY EXIT SIGN INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE AFT GALLEY…
- 3 Mar 2013
Battery, discharged
DURING B INSPECTION FOUND THE EMERGENCY CEILING LIGHT 2ND FROM FRONT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 2…
- 16 Jan 2013
Battery, discharged
DURING MAINTENANCE CHECK FOUND THE OUTSIDE FORWARD RIGHT EMERGENCY LIGHT AND NR 2 AISLE OVERHEAD LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE.…
- 15 Jan 2013
Light, defective
ON FLIGHT 3273 THE CREW REPORTED THE READING LIGHT AT 8C SMELLED HOT. REMOVED AND REPLACED THE READING LIGHT LAMP AT SEAT 8C IAW EMB 145 AMM 33-25-02. THE…
- 10 Jan 2013
Engine, power loss
ON FLIGHT 3422 THE CREW ABORTED TAKEOFF DUE TO GREATER 80 KNOTS TAKEOFF POWER LOSS ON NR 2 ENGINE AND LOSS OF NR 2 ITT. THE AIRCRAFT WAS REMOVED FROM SERVICE.…
- 15 Sep 2012
Light, inoperative
DURING B INSPECTION FOUND THE RIGHT AFT EXTERNAL OVERWING EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE RIGHT…
- 28 Aug 2012
Light, inoperative
DURING MAINTENANCE INSPECTION, FOUND THE RIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE RIGHT OVERWING…
- 4 Aug 2012
Lamp, inoperative
DURING MAINTENANCE INSPECTION, FOUND THE RIGHT EMERGENCY EXIT LIGHT INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. LAMPED EMERGENCY LIGHT IAW MM 33-50-10. TESTED…
- 4 Aug 2012
Lamp, inoperative
DURING MAINTENANCE INSPECTION, FOUND THE LEFT EMERGENCY EXIT LIGHT INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. RELAMPED EMERGENCY LIGHT IAW MM 33-50-10.…
- 12 Jul 2012
Connector, loose
DURING B INSPECTION, FOUND THE FORWARD FLOOR EMERGENCY STRIP INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. TROUBLESHOT AND FOUND GS 8508DC TO NOT HAVE A GOOD…
- 1 Jun 2012
Unknown, odor
FLIGHT 3527, AFTER SELECTING IGNITION ON IN MODERATE RAIN AND TURBULENCE, NOTICED A STRONG ELECTRICAL BURNING ODOR IN COCKPIT AND FORWARD CABIN. ODOR…
- 8 May 2012
Flashlight, inoperative
ON FLIGHT 3514 THE CREW REPORTED THE CAPTAIN'S FLASHLIGHT WAS INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE CAPTAIN'S FLASHLIGHT…
- 16 Mar 2012
Light, inoperative
DURING B-INSPECTION FOUND SEAT 1 AND 2 EMERGENCY FLOOR STRIP INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED SEAT 1A/2A EMERGENCY…
- 20 Feb 2012
Light, inoperative
DURING B-INSPECTION, FOUND THE RIGHT OVERWING EMERGENGY LIGHT INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE RIGHT OVER WING EMERGENCY…
- 13 Jan 2012
Light, inoperative
DURING MAINTENANCE INSPECTION FOUND THE FIRST EMERGENCY LIGHT FLOOR STRIP INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED FLOOR STRIP…
- 3 Dec 2011
Wire, broken
DURING MAINTENANCE INSPECTION FOUND THE NR 1 EMERGENCY LIGHT STRIP HAS A BROKEN WIRE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED WIRE AT NR 1 FLOOR…
- 3 Dec 2011
Connector, missing
DURING MAINTENANCE INSPECTION FOUND THE EMERGENCY LIGHT STRIP ELECTRICAL CONNECTOR MISSING AT FLOOR PANEL 251DF. THE AIRCRAFT WAS REMOVED FROM SERVICE.…
- 3 Dec 2011
Inverter, inoperative
DURING MAINTENANCE INSPECTION FOUND THE FIRST THREE FLOOR PROXIMITY LIGHT AND RIGHT OVERWING EMERGENCY LIGHTS INOPERABLE. THE AIRCRAFT WAS REMOVED FROM…
- 3 Dec 2011
Flashlight, cracked
DURING MAINTENANCE INSPECTION FOUND THE FLIGHT ATTENDANT’S EMERGENCY FLASHLIGHT BASE CRACKED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE…
- 18 Dec 2010
Engine, leaking
ON FLIGHT 2889 DURING TAKEOFF THE CREW REPORTED A SMOKE AND BURNING ODOR IN THE AFT CABIN. THE CREW ELECTED TO RETURN TO DFW. THE AIRCRAFT LANDED WITHOUT…
- 5 Jun 2010
Display, malfunctioned
ON FLIGHT 4107 THE CAPTAIN REPORTED THAT AFTER TAKEOFF DURING CLIMB APPROXIMATELY AT 13,000 FEET, LOST ALL CAPTAIN’S PRIMARY FLIGHT DISPLAY ATTITUDE/ALTIMETER…
- 11 Apr 2010
Attach Fitting, lack of lube
ON FLIGHT 4082 THE CREW REPORTED, UNABLE TO PROPERLY CLOSE THE MAIN CABIN DOOR. THE AIRCRAFT WAS REMOVED FROM SERVICE. LUBED ATTACH FITTINGS AND PERFORMED AN…
- 22 Mar 2010
Battery, discharged
DURING MAINTENANCE BASE VISIT FOUND THE RIGHT FORWARD EXTERIOR EMERGENCY LIGHT AND NR 2 CABIN CEILING EMERGENCY LIGHT WOULD NOT ILLUMINATE. THE AIRCRAFT WAS…
- 18 Mar 2010
Fitting, damaged
DURING MAINTENANCE BASE INSPECTION FOUND THE RIGHT AILERON DAMPER FITTING TO BE DAMAGED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE RIGHT…
- 29 Jul 2009
Engine, shutdown
ON FLIGHT 3741 - CREW REPORTED ENGINE 1 FAILED (UNCOMMANDED SHUTDOWN) ON TAKEOFF AT APPROXIMATELY 10 KNOTS. AIRCRAFT REMOVED FROM SERVICE. AWAITING FOLLOW-UP.
- 26 Jun 2006
Floor Support, corroded
SAW - DURING MBV INSPECTION, FOUND LEFT OMEGA BEAM AT FRAME 20 CORRODED. REPAIRED BEAM AT FRAME 20 IAW EMB 145 SRM 53-00-10 FIGURE 201 BY INSTALLING A…
- 30 Aug 2005
Battery Pack, inoperative
CREW REPORTED AFTER NORMAL SHUTDOWN EMERGENCY LIGHTS AT ROWS 8 THROUGH 12. MAINTENANCE REMOVED AND REPLACED THE NR 3 BATTERY PACK IAW EMB MM. OPERATIONAL…