N672AA
1992 Boeing 757-223 standard FAA →
reservations
earlier registrations
2 past records
- 1992
service difficulty reports
47 reports
- 11 Aug 2011
Battery Pack, weak
SEAT MOUNTED EMERGENCY EGRESS LIGHTS INOP.
- 4 Dec 2010
Light, defective
CABIN EMERGENCY LIGHT DIM. REPLACED LAMP FOR EMERGENCY LIGHT IN CABIN. OPS CHECK NORMAL.
- 4 Dec 2010
Light, defective
EMERGENCY LIGHT IN CABIN DIM. REPLACED LAMP FOR EMERGENCY LIGHT IN CABIN. OPS CHECK NORMAL.
- 8 Aug 2010
Warning System, malfunctioned
FLIGHT DECK EMERGENCY EVACUATION AURAL WARNING DEVICE WILL NOT TEST. RESET SYSTEM CIRCUIT BREAKER. OPS CHECKED NORMAL.
- 6 Jul 2010
Battery Pack, discharged
EMEREGENCY EXIT PATH LIGHT AFT SECTION OF COACH INOPERATIVE. REPLACED FORWARD BATTERY PACK FOR AFT COACH EMERGENCY LIGHTS. OPS CHECKED NORMAL.
- 6 Jul 2010
Battery Pack, discharged
EMERGENCY EXIT PATH LIGHT AFT SECTION OF COACH INOPERATIVE. REPLACED AFT BATTERY PACK FOR AFT COACH EMERGENCY LIGHTS. OPS CHECKED NORMAL.
- 2 Mar 2010
Light, inoperative
EMERGENCY LIGHT UNDER OVERHEAD COMPARTMENT AT 31ABC INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT UNDER OVERHEAD COMPARTMENT AT 31ABC. OPS CHECKED NORMAL.
- 2 Mar 2010
Light, inoperative
EMERGENCY LIGHT UNDER OVERHEAD COMPARTMENT AT 23ABC INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT UNDER OVERHEAD COMPARTMENT AT 23ABC. OPS CHECKED NORMAL.
- 13 Feb 2010
Battery Pack, discharged
EMERGENCY LIGHTS FROM ROWS 16 TO 25 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS FROM ROWS 16 TO 25, OPS CHECK NORMAL.
- 9 Oct 2009
Battery Pack, discharged
EMERGENCY SEAT MOUNTED LIGHTS AT SEAT ROWS 9DEF TO 17DEF INOPERATIVE. REPLACED BATTERY PACK.
- 13 May 2009
Power Supply, odor
CREW REPORTED ELECTRIC ODOR IN MID CABIN. EMERGENCY DECLARED RETURNED DFW WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND POWER SUPPLY POSTA AT 17ABC…
- 27 Nov 2008
Charger, failed
EMERGENCY LIGHT FROM SEAT ROWS 14 TO 36 INOPERATIVE. REPLACED BATTERY CHARGER FOR SEAT ROWS 14 TO 36. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 14 Oct 2008
Beam, corroded
TOP OF LATERAL I BEAM CORRODED. REPAIRED IAW SRM 53-00-51-2R.
- 13 Oct 2008
Floor Support, corroded
FLOOR SUPPORT CORRODED FOR G1B GALLEY. REPLACED SUPPORT IAW SRM 53-00-00-0G.
- 13 Oct 2008
Floor Support, corroded
FLOOR SUPPORT CORRODED FOR G1B GALLEY. REPLACED SUPPORT IAW SRM 51-00-51-0G.
- 13 Oct 2008
Floor Support, corroded
FLOOR SUPPORT CORRODED BELOW G1B GALLEY. REPLACED FLOOR SU[PPORT IAW SRM 53-60-51
- 9 Oct 2008
Structure, corroded
MAIN DECK FLOOR STRUCTURE IS CORRODED. REMOVED CORROSION AND INSTALLED DOUBLER IAW SRM 53-60-51-2R2.
- 9 Oct 2008
Plate, corroded
AFT MAIN DECK PLATE IS CORRODED. DOUBLER INSTALLED IAW SRM 53-60-51-2R2.
- 9 Oct 2008
Plate, corroded
AFT MAIN DECK IS CORRODED. DOUBLER INSTALLED IAW SRM 53-60-51-2R2.
- 9 Oct 2008
Structure, corroded
AFT MAIN DECK FLOOR STRUCTURE IS CORRODED. REPAIRED IAW SRM 53-60-51-2R2.
- 9 Oct 2008
Floor Panel, corroded
AFT MAIN DECK FLOOR STRUCTURE IS CORRODED. REPAIRED IAW SRM 53-60-51-2R2.
- 27 Jun 2008
Light, inoperative
DFW - EMERGENCY LIGHT AT SEAT 4B BULLNOSE INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 4B BULLNOSE. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)
- 27 Jun 2008
Light, inoperative
DFW - EMERGENCY LIGHT AT SEAT 18A INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 18A. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)
- 27 Jun 2008
Light, inoperative
DFW - EMERGENCY LIGHT AT SEAT 31D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 31D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)
- 14 Apr 2008
Lamp, inoperative
DFW - EMERGENCY LIGHT AT AFT OVERWING DOOR INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT AFT OVERWING DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 15 Dec 2006
Bulb, burned out
DFW - EMERGENCY LIGHT AT RIGHT AISLE BULLNOSE SEAT 25D INOPERATIVE. RELAMPED EMERGENCY LIGHT AT RIGHT AISLE BULLNOSE SEAT 25D. SYSTEM GROUND CHECKED NORMAL…
- 15 Dec 2006
Bulb, burned out
DFW - EMERGENCY LIGHT AT LEFT AISLE BULLNOSE SEAT ROW 1AB INOPERATIVE. RELAMPED EMERGENCY LIGHT AT LEFT HAND AISLE BULLNOSE SEAT ROW 1AB. SYSTEM GROUND…
- 15 Dec 2006
Light, broken
DFW - SEAT MOUNTED EMEGENCY LIGHT AT SEAT 35D HAS BROKEN LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY FOR SEAT MOUNTED EMERGENCY LIGHT AT SEAT 35D. SYSTEM GROUND…
- 15 Dec 2006
Bulb, burned out
DFW - EMERGENCY FLOOD LIGHT AT INTERIOR OVERWING EXIT HATCH FORWARD EMERGENCY HANDLE INOPERATIVE. RELAMPED EMERGENCY FLOOD LIGHT AT INTERIOR OVERWING EXIT…
- 15 Dec 2006
Battery Pack, inoperative
DFW - SEAT MOUNTED EMERGENCY LIGHTS FROM SEAT ROWS 16 TO 26 INOPERATIVE. REPLACED BATTERY PACK FOR SEAT MOUNTED EMERGENCY LIGHTS FROM SEAT ROWS 16 TO 26.…
- 15 Dec 2005
Guard, broken
DFW - EMERGENCY LIGHT SWITCH GUARD AT FLIGHT DECK IS BROKEN. REPLACED THE EMERGENCY LIGHT SWITCH GUARD AT FLIGHT DECK. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 25 Jul 2004
Pitot Tube, missing
ORD - INFLIGHT T725/25 AT INTERMEDIATE LEVEL OFF AT FL280 RIGHT ENGINE BEGAN TO SURGE BETWEEN 1.53 AND 1.66 EPR 91.5 TO 94.0 PERCENT N1 AT 670 TO 700C. EGT…
- 27 Nov 2003
Battery Pack, discharged
SFO AFT RIGHT HAND INBOARD ATTENDANT EMERGENCY FLASHLIGHT LED INOPERATIVE. REPLACED BATTERY PACK FOR AFT RIGHT HAND INBOARD ATTENDANT EMERGENCY FLASHLIGHT.…
- 18 Sep 2003
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE PATH LIGHTING WAS OBSERVED TO BE INOPERATIVE AT SEAT ROWS 24 THROUGH 34. REPLACED BATTERY PACK. SYSTEM…
- 15 Sep 2003
Battery Pack, discharged
LAX - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE PATH LIGHTING WAS OBSERVED TO BE INOPERATIVE AT SEAT ROWS 24 THROUGH 34. REPLACED BATTERY PACK. SYSTEM…
- 29 Mar 2003
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMREGENCY EXIT SEAT MOUNTED LIGHT AT 11D INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL…
- 19 Dec 2000
Sill, corroded
AFW - AFT CARGO LOWER SILL OUTBOARD CHORD HAD CORROSION BLENDED ON THE OUTBOARD VERTICAL LEG. BLENDOUT CORROSION AND VERIFY NO CRACKS. ALODINE AND APPLY 2…
- 19 Dec 2000
Sill, corroded
AFW - FOUND AFT CARGO LOWER SILL ''T'' CHORD HAD CORROSION BLENDED TOP OUTBOARD SURFACE BEYOND SRM LIMITS. BLENDOUT CORROSION AND VERIFY NO CRACKS. ALODINE…
- 25 Mar 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT 9D, 17D, AND 16D INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP AT 9D,…
- 8 Nov 1999
Light, failed
TUL - FLT 1998 - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING FROM ROW 9 TO ROW 17 INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT…
- 25 Jan 1997
Sill, corroded
AFW - AFT CARGO DOOR SILL INNER CHORD HAD CORROSION BLENDED BEYOND SRM LIMITS. E58 NR 1813131. REPAIRED PER MRB NR 757-1063. TST: 14,920.38 HOURS. CYCLES,…
- 25 Jan 1997
Floor Beam, corroded
AFW - FLOOR BEAM AT STA 1640 HAD SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS. E58'S NR 1803648, 1803564 (ITEM 2), AND 1803650. REPAIRED PER MRB NR…
- 25 Jan 1997
Floor Beam, corroded
AFW - FLOOR BEAM AT STA 345, RBL 63, HAD CORROSION BLENDED BEYOND SRM LIMITS. E58 NR 1803707. REPAIRED PER MRB NR 757-1058. TST: 14,920.38 HOURS. CYCLES,…
- 25 Jan 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STA 407 TO STA 418, RBL 45 HAD CORROSION BLENDED BEYOND SRM. E58 NR 1803716. REPAIRED PER MRB NR 757-1057. TST: 14,920.38 HOURS.…
- 25 Jan 1997
Floor Beam, corroded
AFW - FLOOR BEAM STA 324, RBL 60 HAD CORROSION BLENDED BEYOND SRM LIMITS. E58 NR 1803687. REPAIRED PER MRB NR 757-1056. TST: 14,920.38 HOURS. CYCLES: 5,447. (X)
- 25 Jan 1997
Floor Beam, corroded
AFW - FLOOR BEAM STA 310, RBL 4 AND RBL 41 HAD CORROSION BLENDED BEYOND SRM LIMITS. E58 NR 1803682 AND 1803683. REPAIRED PER MRB NR 757-1055. TST: 14,920.38…
- 25 Jan 1997
Floor Beam, corroded
AFW - FLOOR BEAM STA 365, RBL 63 AND RBL 10 HAD CORROSION BLENDED BEYOND SRM LIMITS. E58 NR 1803710 AND 1803708. REPAIRED PER MRB NR 757-1054. TST: 14,920.38…