N670AA
1992 Boeing 757-223 standard FAA →
registration
- 1992
service difficulty reports
44 reports
- 6 May 2011
Cooling Fan, seized
LAS - INFLIGHT MIA-SFO. CREW REPORTED SMOKE AND FUMES IN AND COCKPIT AND THROUGH OUT CABIN. EQUIPMENT OVERHEAT LIGHT ILLUMINATED. ACCOMPLISHED QRH PROCEDURES…
- 10 Oct 2010
Actuator, leaking
BOS - THE TOWER REPORTED SMOKE COMING FROM LEFT HAND MAIN GEAR UPON LANDING. TOWER DECLARED EMERGENCY. SMOKE WAS ALSO COMING FROM LEFT HAND ENGINE AS REPORTED…
- 19 Apr 2010
Angle, cracked
INTERCOSTALS TOP L-ANGLE IS CRACKED BELOW THE CABIN FLOOR AT BUTTLINE 0 BETWEEN STATIONS 1580 TO 1600. REMOVED TOP ANGLE OF INTERCOSTAL AND INSTALLED…
- 16 Apr 2010
Transition Panel, corroded
RIGHT TRANSITION PANEL CORRODED STATION 1380. REMOVED AND REPLACED PANEL PER SRM 51-10-02.
- 15 Apr 2010
Angle, cracked
BELOW THE CABIN FLOOR THE INTERCOSTAL AT BUTTLINE 0 TOP L-ANGLE IS CRACKED AT THE AFT THREE NUT PLATES BETWEEN STATIONS 1200 TO 1220. INSTALLED NEW ANGLE…
- 15 Apr 2010
Intercostal, cracked
FORWARD CARGO - FRAME STATION 660 LEFT BUTTLINE 48 FLOOR BEAM INTERCOSTAL FORWARD ANGLE CRACKED. INSTALLED INTERCOSTAL PER SRM 51-10-02-G8.
- 15 Apr 2010
Sill, corroded
THE TOP OF THE AFT CARGO DOOR SILL IS CORRODED BETWEEN STATIONS 1380 TO 1440. REMOVED AND REPLACED SILL PANEL PER SRM 51-10-02-G8.
- 17 Nov 2009
Battery Pack, discharged
EMERGENCY LIGHT AT SEAT ROWS 17-25 DIM. REPLACED BATTERY PACK.
- 17 Nov 2009
Battery Pack, discharged
EMERGENCY LIGHTS AT SEATS ROWS 1E TO 6E INOPERATIVE. REPLACED BATTERY PACK.
- 27 Aug 2009
Battery Pack, discharged
FIRST CLASS AISLE EMERGENCY LIGHTS DIM AND ROW 9 TO 16 EMERGENCY LIGHT INOP. REPLACED BATTERY, OPS CHECK OK.
- 8 Dec 2008
Processor, failed
LGA INFLIGHT - CREW REPORTED FUEL QUANTITY STATUS MESSAGE AND ALL FUEL QUANTITY INDICATIONS WENT BLANK RETURNED TO LGA AND LANDED WITHOUT INCIDENT. REPLACED…
- 10 Oct 2008
Skin, corroded
CORROSION AROUND FASTENER HEAD, 29 INCH FROM INBOARD END OF NR 1 SLAT 5 INCH FORWARD OF UPPER TRAILING EDGE OF LEADING EDGE SKIN. REMOVED DAMAGED SKIN AND…
- 10 Oct 2008
Skin, damaged
NUMEROUS PREVIOUS BLENDOUTS ON NR 1 SLAT IN AREA 30 INCH FROM OUTBOARD END OF SLAT. REPAIRED DAMAGED SKIN IAW SRM 57-43-01.
- 8 Oct 2008
Doubler, corroded
REPAIR DOUBLER FOUND CORRORED, INSTALLED NEW DOUBLER ALUM 2024-T3 PER SRM 53-60-51-2R.
- 7 Oct 2008
Support, corroded
LT THRESHOLD GUTTER DRAIN, SUPPORT IS CORRODED AT STATION 1640 TO STATION 1680.
- 7 Oct 2008
Support, corroded
RT DRAIN PAN SUPPORT IS CORRODED.
- 7 Oct 2008
Support, corroded
RT THRESHOLD DRAIN PAN, SUPPORT IS CORRODED.
- 7 Oct 2008
Support, corroded
SUPPORT IS CORRODED.
- 7 Oct 2008
Floor Support, corroded
FLOOR SUPPORT IS CORRODED.
- 28 May 2008
Lens, missing
DFW - EMERGENCY LIGHT AT SEAT 9D MISSING CLEAR LENS. REPLACED LENS FOR EMERGENCY LIGHT AT SEAT 9D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)
- 28 May 2008
Sign, damaged
DFW - EMERGENCY LIGHT PLACARD FOR FORWARD EXIT AT SEAT ROW 18ABC DAMAGED. REPLACED PLACARD FOR EMERGENCY LIGHT FORWARD EXIT AT SEAT 18ABC. SYSTEM GROUND…
- 17 Jun 2007
Battery Pack, inoperative
BOS - EMERGENCY EXIT LIGHT AT SEAT ROWS 9 TO 16 INOPERATIVE. REPLACED BATTERY PACK AT STATION 692 FOR EMERGENCY EXIT LIGHT AT SEAT ROWS 9 TO 16. SYSTEM GROUND…
- 26 Apr 2007
Light, inoperative
DFW - SEAT MOUNTED EMERGENCY LIGHTS AT SEAT ROW 11D INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY AT SEAT ROW 11D. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 15 Mar 2007
Slide, failed
SCU - LEFT NUMBER ONE DOOR SLIDE WAS LEFT IN ARMED POSITION AND SLIDE FELL ON AIRSTAIRS WHEN DOOR OPENED. SLIDE FAILED TO DEPLOY. REPLACED LEFT NUMBER ONE…
- 27 Aug 2006
Connector, loose
EMERGENCY LIGHT AT SEAT 11D INOPERATIVE. SECURED LOOSE CONNECTOR UNDER SEAT 11D FOR INOPERATIVE EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 5 Jun 2004
Battery Pack, discharged
MIA - EMERGENCY LIGHTS IN CABIN ON INTERMITTENTLY. REMOVED AND REPLACED CENTER BATTERY PACKS. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 21 May 2004
Battery Pack, discharged
LGA - EMERGENCY EXIT LIGHT AT R2 DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY EXIT LIGHT AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 5 May 2004
Module, inoperative
JFK FIRST CLASS SEAT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY CHARGER MODULE FOR FIRST CLASS SEAT EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL…
- 11 Oct 2002
Smoke, detected
DFW - FLT 1870 - EN ROUTE DFW-ATL, AT TAKEOFF, ELECTRICAL SMOKE IN THE COCKPIT AND MID CABIN LIGHT SMELL. RETURNED AND LANDED AT DFW WITHOUT INCIDENT.…
- 22 Oct 2001
Wire, disconnected
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 17D INOPERATIVE. RE-CONNECTED EMERGENCY EXIT LIGHT WIRE AT SEAT 17D. SYSTEM GROUND CHECKED…
- 24 May 2001
Connector, inoperative
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH IGHT 18D INOPERATIVE. RESEATED CONNECTOR SEAT 18D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 28 Feb 2001
Line, leaking
DFW - FLT 1881 - EN ROUTE AUS-SJC - LEFT HYDRAULIC SYSTEM QUANTITY DECREASED TO ZERO. DIVERTED DFW AND LANDED WITHOUT FURTHER INCIDENT. REPLACED RIGHT MAIN…
- 1 Nov 2000
Bulkhead, cracked
AFW - RIGHT PYLON MID BULKHEAD HAS GOUGE BLENDED ON EDGE. BLEND OUT DAMAGE, DYE CHECK FOR CRACKS, ROTO-PEEN, ALODINED AND PRIMED THE BLENDED AREA. IT IS…
- 1 Nov 2000
Door Frame, corroded
AFW - CX COMP DOOR CUT OUT LOWER MAIN AFT SILL OUTER CHORD HAS CORROSION. REMOVED CORROSION, VERIFY CORROSION COMPLETELY REMOVED, APPLY ALODINE AND 2 COATS…
- 22 Sep 2000
Connector, damaged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS FROM ROW 9D THROUGH 15D INOPERATIVE. REPAIRED CONNECTOR AT SEAT 15D. SYSTEM GROUND…
- 13 Jan 1997
Chord, corroded
AFW - AFT CARGO DOOR CUTOUT LOWER CHORD HAD CORROSION BLENDED ON THE VERTICAL LEG OUTBOARD SIDE BEYOND SRM LIMITS. REPAIR PER MRB 757-1052. (M)
- 2 Jan 1997
Pan, gouged
AFW - R-4 DOOR PAN HANDLE PAN HAS GOUGE BEYOND SRM LIMITS, REF E58 1814487. REPAIRED PER MRB NR 757-1051. (M)
- 1 Jan 1997
Floorbeam, corroded
AFW - FLOORBEAM AT STATION 324 RBL 62 HAS CORROSION BLENDED BEYOND SRM LIMITS E58 1814625. REPAIRED PER MRB NR 757-1046, DATED 01-01-97. (M)
- 1 Jan 1997
Floorbeam, corroded
AFW - FLOORBEAM AT STATION 310 RBL 40 HAD CORROSION BLENDED, BEYOND SRM LIMITS REF E58 18146021. REPAIRED PER MRB NR 757-1047. (M)
- 1 Jan 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 405 RBL 59 HAD CORROSION BLENDED BEYOND SRM LIMITS, REF E58 1814605, ITEM NR 1. REPAIRED PER MRB NR 757-1048. (M)
- 1 Jan 1997
Structure, corroded
AFW - FLOOR STRUCTURE AT STATION 300 RBL 39 HAD CORROSION BLENDED BEYOND SRM LIMITS, REF E58 1814624. REPAIRED PER MRB NR 757-1049. (M)
- 1 Jan 1997
Floorbeam, corroded
AFW - FOUND FLOORBEAM AT STATION 1640 RBL 57 AND LBL 19.5 HAD CORROSION BLEND BEYOND SRM LIMITS ES8'S 1814655 AND 1814654. REPAIRED PER MRB NR 757-1045, DATED…
- 31 Dec 1996
Pan, gouged
AFW - R-1 DOOR HANDLE PAN HAS GOUGE BEYOND SRM LIMITS, REF E58 1814484. REF MRB NR 757-1050. (M)
- 7 Jul 1995
Eel Wire, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY PATH LIGHTS FROM L2 DOOR TO OVERWING EMERGENCY EXITS FOUND INOPERATIVE. REPLACED BROKEN EMERGENCY PATH LIGHT WIRE AT…