N6610E
1991 Bell 206L-3 standard FAA →
reservations
earlier registrations
2 past records
- 1991
NTSB
- 26 Aug 1999
accident, Main Pass 225A
service difficulty reports
16 reports
- 6 Aug 1999
Clock, failed
CLOCK NOT WORKING.
- 22 Jan 1999
Pump, cracked
PUMP HAS CRACK INDICATION ON HOUSING AND WORN SPLINE ON SHAFT.
- 11 Sep 1998
Case, cracked
CRACK INDICATION ON BOTTOM OF MAIN CASE, INSIDE AND OUT, IN SAME PLACE. SCRAPPED CASE AND REPLACED WITH NEW CASE.
- 29 Apr 1998
Elt, defective
ELT RESET BUTTON WILL NOT SPRING BACK.
- 5 Feb 1998
Indicator, failed
ENG OIL INDICATOR INOPERATIVE-DOES NOT WORK. INDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DIDN'T…
- 27 Jan 1998
Loran, failed
LORAN DOES NOT DISPLAY DATA, DISPLAYS MOSTLY LINES.
- 10 Oct 1997
Attitude Gyro, faulty
ATTITUDE GYRO WILL NOT STAY CAGED.
- 4 Jun 1997
Actuator, failed
ACTUATOR WILL NOT RUN. SENT FOR INSPECTION AND REPAIR.
- 3 Dec 1996
Comb Liner, mis mfg
WHILE INSTALLING NEW COMBUSTION LINER FOR TROUBLESHOOTING TORQUE FLUX AT HIGH POWER SETTINGS. WAS UNABLE TO INSTALL IGNITOR - DUMMY PLUG AND FUEL NOZZLE AT…
- 21 Jun 1996
Indicator, reads high
PSI READS HIGH AT HIGH RANGE.
- 15 Nov 1995
Seal, leaking
SEAL LEAKING.
- 15 Nov 1995
Exhaust Assy, cracked
EXHAUST ASSY IS CRACKED.
- 5 Oct 1995
Receiver, defective
INSPECTED UNIT AND FOUND THAT R/H INNER KNOB PULLS OUT AND R/H OUTER KNOB LOCKS UP.
- 8 Aug 1995
Transceiver, inoperative
TRANSPONDER INOPERATIVE. OFF FREQUENCY. ADJUSTED FREQUENCY TO SPECS. REPAIRED. ALSO FOUND UNIT TO HAVE WEAK RECEIVE AND INTERMITTENT TRANSMIT. REPLACED MIXER…
- 1 Nov 1994
Transceiver, weak
WEAK (REPORTED AS INTERMITTENT) REPLACED DEFECTIVE V101 CAVITY OSCILLATOR AND DETERIORATED RESISTOR R-477. REPAIRED.
- 7 Sep 1994
Filter Assembly, defective
BY-PASS BUTTON POPPING.