N659JB
2007 Airbus A320-232 standard FAA →
registration
- 2007
service difficulty reports
52 reports
- 8 Sep 2025
Unknown, odor
FLT#1904, RDU-SJU. FUMES EVENT ODOR REPORT SUBMITED DESCENDING THRU 10,700 FT, FLT CREW EXPERIENCED BURNING OF NOSE AND THROAT, CHEMICAL ODOR, PACK 1…
- 25 Aug 2025
A/C Pack, odor
FLT#373, BOS-AUA. PERSISTENT OIL SMELL ODOR ROW 20 AND AFT WITH PACK 1+2 ON ( PACKS ); COMPLIED WITH INFORMATION NOTICE 2017-T015, SECTION B2. IDENTIFIED ODOR…
- 20 Apr 2025
Unknown, odor
FLT#2433, DCA-PBI. 'LEVEL 2 FUME/ODOR EVENT - DISTINCT STRONG PERSISTENT ODOR DETECTED BY MULTIPLE CREW MEMBERS INITIALLY AT 18,000 FEET DESCENDING THEN AGAIN…
- 21 Dec 2024
Valve, faulted
FLT#1016, PUJ- EWR. (AIRCRAFT DIVERTED TO RDU) ' ( HIGH PRESSURE VALVES (HPV) )AIR ENG 2 BLEED FAULT AFTER FOLLOWING QRH DIVERT TO RDU. (SUPPLEMENTAL…
- 16 Dec 2023
Unknown, unknown
FLT#1401, JFK-FLL. 'IN BOUND INFLIGHT CREW REPORTED DIRTY SOCKS ODOR; COMPLIED WITH INFORMATION NOTICE 2017-T015 SECTION A . ISOLATED FAULT TO TYPE 10 (A) 1C…
- 10 Nov 2023
Unknown, unknown
FLT#2625, RDU-FLL. 'DIRTY SOCK SMELL DESCENDING THRU 10K FT. PREVIOUS HISTORY.' (SUPPLEMENTAL INFORMATION TO FOLLOW)
- 8 Nov 2023
Unknown, unknown
FLT#571, LGA-FLL. 'DIRTY SOCK SMELL REPORTED BY CABIN CREW BELOW 10000 ON DESCENT; COMPLIED WITH INFORMATION NOTICE 2017-T015, SECTION A ISOLATED FAULT TO…
- 17 Sep 2023
Unknown, unknown
FLT# 814, FLL-HPN. "INFLT REPORTS NAUSEAS OIL SMELL IN CABIN.CUSTOMERS COMPLAIN/CONCERNED; COMPLIED WITH INFO NOTICE 2017-T015 SECTION A ISOLATED FAULT TO…
- 12 Aug 2023
Unknown, unknown
FLT#2708, SDQ-JFK. 'WO #1271940 SVC CHK AND LH L1 DOOR SLIDE ASSIGNED; WO #1271940 SERVICE CHECK AND L1 DOOR SLIDE C/W.'
- 9 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION INTERNAL STRUCTURE WEB LOC. BTW FR69 AND FR70 AT LEVEL STR23R AT AFT GALLEY AREA. (CPCP-RELATED TASK 534195-01); (RESOLVED…
- 9 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACKS INDICATION FOUND ON SEGMENT 1 LOC IB AND OB AREA OF DOOR EMERGENCY 834; REF TO AEROMAN WO 2023 133/1 NR 2023-308942,…
- 9 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACKS INDICATION FOUND ON SEGMENT 1 LOC IB AND OB AREA OF DOOR EMERGENCY 834; REF TO AEROMAN WO 2023 133/1 NR 2023-308940,…
- 9 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACKS INDICATION FOUND ON SEGMENT 1 LOC IB AND OB AREA OF DOOR EMERGENCY 834; REF AEROMAN NR 2023-308939 W/O:2023 133/1:…
- 9 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACKS INDICATION FOUND ON SEGMENT 1 LOC IB AND OB AREA OF DOOR EMERGENCY 843; REF TO AEROMAN WO 2023 133/1 NR 2023-308941,…
- 9 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACKS INDICATION FOUND ON SEGMENT 1 LOC IB AND OB AREA OF DOOR EMERGENCY 833; REF TO AEROMAN WO 2023 133/1 NR 2023-308938,…
- 21 Jan 2023
Wire, open
FLT#268, PUJ-JFK. 'L2 AND R2 DOOR LOWER EMERGENCY LIGHTS WILL NOT ILLUMINATE DURING TEST IAW ASM 33-51-04 AND AWM 33-51-08. CHECK WIRING 90WL7 TO 7222VT-4H F…
- 25 Sep 2022
None, none
FLT#169, BDL-FLL. 'PASSING 8000FT IN DESCENT BURNED OIL/ DIRT SOCK ODOR OBSQUED CABIN AND COCKPIT THROUGHOUT; PER AMM 49-00-00-20-811-A, INSPECTED APU, REF LP…
- 16 Sep 2022
None, none
FLT#745, JKF-PSE. 'ROTTEN EGG/ DIRTY SOCK SMELL VERY STRONG AT LANDING (PACKS); REF MDDR 485574, THIS ACTION CLEAR MDDR 485569 (AS PER W/O 1205088 PERFORMED…
- 4 Oct 2021
Manifold, disconnected
FLT # 608, LAS-FLL. BRAKES - AUTO BRK FAULT, BRAKES - SYS 2 FAULT ; INSPECTED THE LMLG AND FOUND THE SERVO VALVE MANIFOLD DISCONNECTED (15GG, 17GG, 11GG, AND…
- 4 Oct 2021
Brake Assy, failed
FLT # 608, LAS-FLL. CHAPTER 5 INSPECTION REQUIRED DUE TO #2 TIRE BURST ; ACCOMPLISHED CHAPTER 5 TIRE BURST INSPECTION REF AMM 05-51-15. NO DEFECTS WERE NOTED…
- 4 Oct 2021
Landing Gear, failed
FLT # 608, LAS-FLL. CHAPTER 5 INSPECTION REQUIRED DUE TO #2 TIRE BURST ; ACCOMPLISHED CHAPTER 5 TIRE BURST INSPECTION REF AMM 05-51-15. NO DEFECTS WERE NOTED…
- 4 Oct 2021
Brake, failed
FLT # 608, LAS-FLL. CHAPTER 5 INSPECTION REQUIRED DUE TO #2 TIRE BURST ; ACCOMPLISHED CHAPTER 5 TIRE BURST INSPECTION REF AMM 05-51-15. NO DEFECTS WERE NOTED…
- 4 Oct 2021
Brake, failed
FLT # 608, LAS-FLL. CHAPTER 5 INSPECTION REQUIRED DUE TO #2 TIRE BURST ; ACCOMPLISHED CHAPTER 5 TIRE BURST INSPECTION REF AMM 05-51-15. NO DEFECTS WERE NOTED…
- 7 Jul 2021
Power Supply, inoperative
FLT 81, JFK-RNO. EMERGENCY EXIT SIGNS ON L2 AND R2 AS WELL AS REAR OVERHEAD EMER EXIT SIGN DONT COME ON WITH GEAR DOWN WITH EMER LTS ARMED. THEY DO COME ON…
- 12 Apr 2021
Cabin Air Sys, odor
FLT 1969, BOS-FLL. CABIN ODOR EVENT DURNING CLIMBOUT AND DESCENT, APU WAS OFF; PERFORMED LEVEL ""B"" DECONTAMINATION OF THE ECS IAW AMM 21-00-00-615-803-A.…
- 4 Mar 2021
Unknown, odor
FLT 677, JFK-JAX. NOTICED WET SOCK SMELL ON A/C. TURNED OFF PACK 1 AND SMELL WENT AWAY SMELL HAPPEN ON CLIMB OUT ( PACKS - SINGLE (SPEEDBRAKES OK) (N503-N665)…
- 28 Feb 2021
Unknown, odor
FLT 154, PBI-JFK. MODERATE DIRTY SOCK SMELL DURING CLIMB OUT THAN AGAIN ON DECENT AND APPROACH.LASTED ABOUT 8 MIN DURING EACH EVENT; ENG WASH ACCOMPLISHED ON…
- 16 Feb 2021
Filter, odor
FLT 2625, RDU-FLL. DIRTY SOCK SMELL DETECTED BY ALL CREWMEMBERS DURING DESCENT; ACCOMPLISHED INFO NOTICE 2017-T015F LEVEL 1 ODOR EVENT(ENVIRONMENTAL SYSTEM).…
- 16 Jan 2021
Unknown, odor
FLT 1503, BDL-RSW. PASSING 2500 A ODOR (DIRTY SOCK) SMELL BECAME APPARENT, LEVEL 1. DISSIPATED AFTER A FEW MINUTES. CABIN CREW AND PAX MENTIONED IT ON LANDING…
- 5 Oct 2020
Skin, corroded
DURING HMV, WV UPGRADE N659JB RT WING CORROSSION TOP SKIN TRAILING EDGE REAR SPAR RIB 10, REF NR 2020-288505 WO 2020 273/1. ACCOMPLISHED PERMANT REPAIR ON…
- 13 Nov 2019
Fcu, failed
FT # 1006, LGB-SEA. EMERGENCY DECLARED. UNABLE TO CONTROL SELECTED SPEED ON FCU CAN PULL BUT NOT SELECT A SPEED TO FLY; REMOVED AND REPLACED FCU IAW AMM…
- 28 Sep 2019
Charger, failed
FT # 6460, RT OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY CHARGER FOR R/H OVERWING EMERG. LIGHTS. CHECKS GOOD AT THIS TIME. REPLACED BATTERY OF…
- 11 Jun 2019
Unknown, odor
FT # 882, GOT DIRTY SOCK SMELL IN COCKPIT FOR APPROX 5 MIN ON FINAL APP BETWEEN 3500 FT AND 1500 FT ENG AT IDLE; COMPLIED WITH INFORMATION NOTICE 2017-T015E…
- 12 May 2019
Oil Cooler, contaminated
FLT 1051, JFK-CUN. RETURNED TO FIELD. FUMES REPORTED AT 14:26 NY FA FROM 12 TILL AFT; FOUND ODOR PRESENT WHEN APU BLEED SELECTED ON. FOUND RESIDUAL OIL ON APU…
- 14 Nov 2018
Pump, failed
FT # 1735, BOS-MSP. DIVERTED TO BUF. #2 ENG LO OIL PRESS NO SECONDARIES; REMOVED + REPLACED #2 ENG OIL PRESSURE PUMP ASSY PER AMM 79-21-41 LEAK/OPS GOOD ALSO…
- 18 Dec 2017
Fan, failed
DIVERTED DUE TO AN ELECTRICAL ODOR WAS NOTICED IN THE COCKPIT AND CABIN. NO ECAM MESSAGES OR TRIPPED CIRCUIT BREAKERS WERE NOTED. QRH WAS USED AND ODOR…
- 6 Nov 2017
Battery Pack, inoperative
DURING HEAVY MAINTENANCE, EMERGENCY LIGHT TEST WAS PERFORMED, REAR EXIT SIGNS DID NOT ILLUMINATE. OPS TEST WAS PERFORMED RESULTING IN BATTERY FAULT ON EPSU…
- 6 Nov 2017
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT BETWEEN FRAMES 66 - 67. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-72-11, REV 120.
- 20 Aug 2017
Control Valve, failed
RETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK THE TEMPS…
- 20 Aug 2017
Solenoid Valve, failed
RETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK. THE…
- 20 Aug 2017
Condenser, cracked
RETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK, THE…
- 15 May 2017
Battery Pack, failed
DURING HEAVY MAINTENANCE, EPSU LT BATTERY FAULT WAS DISPLAYED ON THE PTP EMERGENCY LIGHT TEST. R & R THE BATTERY PACK IAW AMM 33-51-38-000-002-A, &…
- 10 Feb 2016
Wire, loose
EMERGENCY EXIT SIGNS L2 & R2 INOPERATIVE. TROUBLESHOT EMERGENCY EXIT SIGNS L2, R2 & FOUND POWER WIRE WAS LOOSE FROM TERMINAL. REINSTALLED WIRE, SECURED &…
- 21 Dec 2015
Coffeemaker, failed
AIR TURNBACK, 1 FORWARD COFFEEMAKER BAG EXPLODED FROM TRAY AFTER COFFEEMAKER WATER BOILED OVER. R & R FORWARD GALLEY COFFEEMAKER NR 1.
- 21 Apr 2015
Filter, contaminated
DURING DESCENT, WITH POWER IN IDLE FOR SOME TIME, CABIN CREW REPORTED SIMILAR ODOR IN REAR OF CABIN. FLIGHT CREW NOTICED A MUSTY ODOR, FAINTLY. RAN PACKS AND…
- 9 Jan 2015
Warning Horn, abnormal
DIVERTED, DURING CLIMB, CRUISE AND MODERATE TURBULENCE, ACFT WARNING SYS ANNOUNCED AND AUDIBLE STALL WARNING EVEN THOUGH THE SPEED WAS 250 KNOTS AND NOT CLOSE…
- 7 Mar 2014
Wire Harness, failed
FLIGHT CREW REPORTED THAT ESCAPE PATH LIGHTING ON FWD PARTITION RED LIGHT INOPERATIVE. ROUTED EMERGENCY LIGHT WIRE BUNDLE THROUGH BULKHEAD AND INSTALLED NEW…
- 8 Feb 2012
Pin, not seated
FLT 537 EWR-TPA, ON GROUND MAINTENANCE CHECK FOUND L2 AND R2 SERVICE DOOR EMERGENCY EXIT SIGNS LIGHTS INOPERATIVE. TROUBLESHOOT EMERGENCY LIGHT EXIT SIGNS L2…
- 31 Dec 2011
Outflow Valve, malfunctioned
FLT 866, AIRCRAFT DIVERTED TO MCO DUE TO THE VENT SKIN AIR VALVE FAULT ON TAKEOFF. VENT OUTLET VALVE WAS STUCK OPEN. TROUBLESHOOTING WAS ACCOMPLISHED IAW TSM…
- 15 Sep 2011
Electrical Box, defective
FLT 562 FLL-SWF, ELECTRICAL BURNING SMELL IN FLIGHT. PERFORMED ELECTRICAL BURNING SMELL INSPECTION PER TSM 24-00-00-810-823 AND TSM 23-39-00-810-801. FOUND…
- 1 Aug 2010
Computer, failed
FLT 283 LAS-LGB, AIR RETURN TO LAS - ON CLIMBOUT THE CREW LEVELED OFF AND NOTICED VENT OUTLET VALVE WAS OPEN. THE VALVE THEN RETURNED TO NORMAL CLOSED…
- 9 Aug 2009
Entertain Sys, malfunctioned
FLT 844 - SJU-BOS - SMELL OF BURNED PLASTIC IN FLT ROWS 3-10, ROW 7 (SEAT 7E) IN PARTICULAR. SMELL DISSIPATED AFTER TURNING LTV OFF. PERFORMED THOROUGH…