53 reports
- 22 Feb 2026
Display, odor
FLT # 213 HPN-FLL. " ODOR OF ELEC SMELL DECENDING THROGH 6000'.;COMPLIED WITH INFO NOTICE 2017-T015 STEPS 1 AND 2 ODOR IDENTIFIED AS TYPE 9 ELECTRICAL BURN…
- 21 Feb 2026
Unknown, odor
FLT # 1245 ISP -PBI. " @ ABOUT 4000 INFLIGHT REPORTED A STRONG SMELL RESEMBLEING ELECTRIC BURN FROM THE MIDDLE OF THE CABIN FORWARD SEVERAL PAX ALSO…
- 10 Jan 2026
Oil System, leaking
FLT 2751, TPA- SJU. INFLIGHT CREW REPORTS FUMES EVENT ON INBOUND FLIGHT. ( APU SYSTEM ). INSPECTION OF THE APU UPON ODOR IN THE CABIN/FUMES IN THE CABIN/OIL…
- 26 Nov 2025
Unknown, odor
FLT#193, EWR-STI. DIRTY SOCK SMELL FROM PACKS ON CLIMBOUT AND DESCENT BELOW 10,000; COMPLIED WITH INFO NOTICE 2017-T015 SECTION B1. IDENTIFY ODOR ON APU, SEE…
- 15 Nov 2025
Unknown, odor
FLT#453, BOS-PLS. "MAGIC MARKER SMELL ON DECENT THROUGH FL230. ON GROUND WITH APU SELECTED, SMELL PERSISTED AND NOTICED BY ALL CREW MEMBERS." (SUPPLEMENTAL…
- 5 Nov 2025
Unknown, odor
FLT#838, JFK-BQN. DIRTY SOCK ODOR NOTICED. STARTED DESCENDING OUT OF 10000 FT. ODOR REACHED MAXIMUM INTENSITY AROUND 2000FT. APPEARS TO BE COMING OUT OF THE…
- 26 Aug 2025
Apu, odor
FLT#2101, JFK-CHS. "WHILE CRUISING AT FL 340 FLIGHT CREW EXPERIENCED AN ODOR SIMILAR TO A MAGIC MARKER IN THE COCKPIT THAT DEVELOPED INTO BURNING EYES AND…
- 20 Aug 2025
Unknown, odor
FLT # 944, BZN-JFK. ODRO EVENT ON DESCENT OUT OF 11,000 FEET UNTIL LANDING SMELL DESCRIBED AS A CHEMICAL SMELL, BOTH FORWARD AND AFT CABIN; RAN APU, ENG 1 &…
- 31 Jul 2025
Battery, no test
FLT#591, BOS-TPA. EMERG LIGHT BATTERY 12WL FAILED TEST; REMOVED AND REPLACED EMERG LIGHT BATTERY FIN 12WL IAW AMM 33-51-38.
- 31 Jul 2025
Battery, no test
FLT#591, BOS-TPA. "EMERG LIGHT BATTERY FIN 11WL FAILED TEST; REMOVED AND REPLACED EMERG LIGHT BATTERY FIN 11WL IAW AMM 33-51-38."
- 31 Jul 2025
Battery, no test
FLT#591, BOS-TPA. "EMERG LIGHT BATTERY FIN 13 WL FAILED TEST; REMOVED AND REPLACED EMER LIGHT BATTERY FIN 13WL IAW AMM 33-51-38"
- 2 Dec 2023
Unknown, unknown
FLT#131, MCO-LAX. 'ODER LEVEL 1 GND OPS AND CRZ PERSISTANT THRUOUT FLIGHT. INCREASE TO LEV 2 DES AND GND OPS. DIRTH SOCK /VINYL. PAC 1 OFF. FCOM PROC,…
- 26 Nov 2023
Unknown, unknown
FLT#2448, SDQ-FLL. '- SOCK SMELL DURING DESCENT AND ON GND W APU RUNNING. LAV B DOOR HARD TO OPEN & CLOSE.' (SUPPLEMENTAL INFORMATION TO FOLLOW)
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: DURING ACCOMPLISHMENT OF THE SAFETY PRECAUTIONS FOR DOOR SLIDES. WE FOUND DOOR (831) RESERVOIR VALVE HOLE MISALIGNED TO INSTALL LOCK…
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND IN FRAME SEGMENT 1 AT THE OVERWING EMERGENCY EXIT DOOR (AFT RH EEH DOOR 844) CRACK L=0. 135 INCH…
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION ON OPEN HOLE H2 LOC FRAME 16 LH CROSSBEAM SPLICING AT PASSENGER CABIN LAYER AFFECTED IS THE FRAME LAYER. CRACK…
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (FWD RH EEH DOOR 843) CRACK L=0.125 INCH APPROX;…
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (FWD LH EEH DOOR 833) CRACK L=0.127 INCH APPROX;…
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (AFT RH EEH DOOR 844) CRACK L=0.135 INCH APPROX;…
- 3 Jul 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND IN FRAME SEGMENTS 1 AT OVERWING EMERGENCY EXIT DOOR (AFT LH EEH DOOR 834) CRACK L=0.130 INCH APPROX;…
- 22 Apr 2023
Unknown, unknown
FLT # 461, LGA-PBI. NON-VISIBLE FUMES ENTERED COCKPIT TWICE DURING FLIGHT. FIRST TIME 2000-6000 FEET THROUGH MOISTURE. SECOND TIME ON DESCENT PASSING 10000FT.…
- 22 Apr 2023
Unknown, unknown
FLT # 461, LLGA-PBI. NON-VISIBLE FUMES ENTERED COCKPIT TWICE DURING FLIGHT. FIRST TIME 2000-6000 FEET THROUGH MOISTURE. SECOND TIME ON DESCENT PASSING…
- 4 Jul 2022
None, none
FLT#880, LAX-LAS'. ODOR SMELLED TRANSIENT ON CLIMBOUT LEVEL 1 CHEMICAL SMELL /MARKER SMELL IN COCKPIT AND AFT GALLEY ALSO WHEN TAXI IN AFTER APU START AND…
- 21 Feb 2022
None, none
FLT# 795, JFK-AUS. FUME ODOR SMELLED ON DESCENT FROM 19,000 TO 12,000 CAPT SMELT ACETONE PAINT SMELL PACK 1 TURNED OFF AND MASK DONNED; COMPLIED WITH…
- 12 Nov 2021
Apu, contaminated
FLT 205, EWR-FLL. ODOR OBSERVED SMELLED ON TAXI OUT AND ON DESCENT. SMELL LIKE SHARPIE MARKER IN COCKPIT & CABIN ; ODOR IN THE CABIN WAS ADDRESSED AND APU…
- 6 Nov 2021
Unknown, odor
FLT 803, JFK-SJU. DIRTY SOCK SMELL IN THE COCKPIT, 10,000 DESCENT 3,000. IDLE THRUST, CLEAR OF CLOUDS. ; PERFORMED ECS DECONTAMINATION LEVEL A PER INFO NOTICE…
- 4 May 2021
Wire Harness, failed
FLT# 861, BOS-SJU. ENG 2 EGT OVERLIMIT 720C FOR 90 SECS TOGA TAKE OFF WITH ENG ANTIICE ON.AT 1000FT AFE ECAM APPEARED. THRUST LEVERS RETARDTED TO CLIMB DETENT…
- 26 Feb 2020
Battery, failed
FT # 2017, BOS-JFK. PERFOMED EPSU BATTERY CAP. TEST PRIOR TO SLIDE TEST. BATTERY 12WL FAILED; R & R EPSU BATTERY 12WL IAW AMM 33-51-38. TEST OK
- 16 Feb 2020
Battery, no test
FT # 1054, PBI-JFK. DURING OPS CHK OF EMERGENCY LIGHT BEFORE SLIDE L/H DOOR REPLACEMENT, FOUND 10 WL BATTERY FAULT; R & R EPSU BATTERY 10WL IAW AMM 33-51-58.…
- 13 Jul 2019
Blower, odor
FT # 531, SLC-LGB. DIVERTED TO LAS. STRONG ELECTRIC SMOKE LIKE SMELL IN COCKPIT QRH CHECKLIST COMPLETED; ACCOMPLISHED TSM 05-50-00-810-831-A INSPECTION FOR…
- 13 Jul 2019
Fan, failed
FLT 1416, LGB-AUS. RETURNED TO FIELD. SAME ISSUE AS PG 2512520, STRONG ELECTRICAL SMOKE LIKE SMELL IN COCKPIT. QRH CHECKLIST COMPLETED; T/S TO EXTRACT FAN FOR…
- 13 Jul 2019
Fan, failed
FLT 1416, LGB-AUS. RETURNED TO FIELD. SAME ISSUE AS PG 2512520, STRONG ELECTRICAL SMOKE LIKE SMELL IN COCKPIT. QRH CHECKLIST COMPLETED; T/S TO EXTRACT FAN FOR…
- 27 Mar 2019
Battery Pack, failed
FT # 740, LEFT OVERWING EMERGENCY POWER SUPPLY UNIT INOPERATIVE. R & R BATTERY EMERGENCY LIGHT AT 11 WL. OPS CHECK GOOD. IAW AMM 33-51-00. A/C OK TO CON'T SVC.
- 27 Feb 2019
Unknown, odor
FLT 14, LGB-JFK. POSSIBLE FUMES EVENT ON DECENT 14000 FT IN FLIGHT. CALLED AND INFORMED OF METALLIC/MEDICINAL SMELL IN FWS GALLEY, THEN AFT. REPORTED SAME…
- 27 Nov 2018
Filter, failed
FT # 878, LAS-BOS. FA#2 REPORTS DIRTY SOCK ODOR ROW 11-14. PERFORMED ODOR RECOGNITION ISOLATION PRPROCEDURE. ODOR GONE WITH PACK 1 OFF. ( PACKS - SINGLE…
- 1 Aug 2018
Unknown, odor
FLIGHT ATTENDANT SMELLED BURNING RUBBER AROUND ROW 5. TROUBLESHOT IAW AMM 24-00-00-810-823A, NO FAULT FOUND, RAN ENGINE WITH EACH PACK, NO ODOR PRESENT.…
- 3 Jun 2018
Battery Pack, failed
EMERGENCY LIGHT FAILED TO TEST. REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY AT EPSU 12WL IAW AMM 33-51-38 OPS CHECKED GOOD.
- 24 Jul 2017
Shaft, leaking
INFLIGHT CREW REPORTED NOXIOUS FUMES IN CABIN DURING FLIGHT. PERFORMED INFO NOTICE 2017-T015A AND FAULT WAS DUPLICATED ON THE NR 2 ENGINE. TROUBLESHOOTING…
- 28 May 2017
Battery Pack, failed
DURING HEAVY MAINTENANCE, EPSU FAULT AFT LT BATTERY. R & R THE BATTERY PACK 13WL IAW AMM 33-51-38. OPS CHECKED GOOD.
- 28 May 2017
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM Y 464 FRAME 66. R & R THE FLOORBEAM IAW SRM 51-42-11, AND 53-41-14, FIG 016.
- 28 May 2017
Shear Plate, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT SHEAR PLATE, STRINGER 32L, FRAME 69 +6. R & R THE SHEAR PLATE IAW SRM 51-42-11.
- 28 May 2017
Shear Plate, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE RT SHEAR PLATE, STRINGER 23R, FRAME 69 +6. R & R THE SHEAR PLATE IAW SRM 51-42-11.
- 28 May 2017
Box Beam, cracked
DURING HEAVY MAINTENANCE, FOUND THE LEFT SIDE BOX BEAM FLANGE FRAME 43 CRACKED. REPAIRED IAW EC 130-53-1251.
- 28 May 2017
Box Beam, cracked
DURING HEAVY MAINTENANCE, IT WAS FOUND THAT RIGHT SIDE BOX BEAM FLANGE AT FRAME 43 HAD A CRACK. CUT OUT DAMAGED AREA OF FLANGE IAW EC A320-53-1251.
- 28 May 2017
Plate, cracked
DURING HEAVY MAINTENANCE, IT WAS FOUND THAT RIGHT SIDE BOX BEAM FLANGE PRESSURE PLATE FR43 HOLE 9 CRACKED AT 0600 POSITION; PRESSURE PLATE REMOVED AND…
- 16 Nov 2015
Oil System, leaking
DIVERTED, OIL QTY WAS NORMAL AT TAKEOFF , ABOUT 2 PLUS INTO FLIGHT, OIL QTY BEGAN TO STEADILY DECREASE AND CONTINUED UNTIL IT READ ZERO, NO OTHER INDICATIONS…
- 16 Nov 2015
Engine, failed
SUP: FLIGHT DIVERTED. OIL QUANTITY WAS NORMAL AT TAKEOFF, ABOUT 2 HRS PLUS INTO FLIGHT, OIL QUANTITY BEGAN TO STEADILY DECREASE AND CONTINUED UNTIL IT READ…
- 21 Sep 2015
Battery Pack, failed
DURING MAINTENANCE AND COMPLETING TASK CARD A320-33-51-00-710-003, UNABLE TO PERFORM TEST DUE TO EPSU BATTERY FWD LT FAULTED. CEILING PANEL 221BC, REMOVED FOR…
- 21 Jul 2015
Connector, damaged
LEFT ROW 23, WHITE EMERGENCY LIGHT INOPERATIVE. R & R DAMAGED CONNECTOR AT ROW 23C IAW ESPM 20-44-11 LT, OPS NORMAL
- 7 Jul 2014
Seal, leaking
AIRCRAFT DIVERTED, THE CREW RECEIVED AN ADVISORY ECAM ON PRESS PAGE, STOP CLIMB A FEW SECONDS LATER. CABIN PRESSURE CLIMB TO 11,000, EMERGENCY DESCENT…
- 16 Feb 2014
Bolt, missing
BOTTOM STARBOARD ENGINE PANEL WAS FOUND ON RUNWAY. FURTHER INSPECTION REVEALED BOLT MISSING AT NR 2 ENGINE TURBINE COOLING (TCA) TUBE REAR FLANGE. INSTALLED…
- 26 Aug 2010
Hydraulic Line, leaking
FLT 381 LGA-FLL, CREW DECLARED EMERGENCY DUE TO ECAM HYD G RSVR LO LVL IN CRUISE. ECAM FOLLOWED BY HYD GREEN ENG 1 PUMP LO PRESS AND HYD G SYSTEM LOST.…
- 22 Oct 2008
Pressure Switch, faulty
AFTER 1 HOUR INTO FLIGHT, CREW OBSERVED A CARGO DISCHARGE 1 LIGHT ILLUMINATED. NO CORRESPONDING ECAM OR SMOKE IND ON CARGO PANEL. FLIGHT DIVERTED TO DENVER.…