- 31 Mar 2008
Windshield, cracked
FLIGHT 5598, DFW TO CLE, DURING CRUISE, THE FLIGHT CREW REPORTED THAT THE LEFT WINDSHIELD CRACKED. THE FLIGHT DIVERTED TO CMH AND LANDED WITHOUT INCIDENT.…
- 20 Jun 2007
Warning Message, false activation
FLIGHT 3338 - CLE-PVD - DURING CRUISE AT FL270, "RT REV UNLOCK" CAUTION MESSAGE APPEARED. RAN THE QRH WHILE STARTING DESCENT. DECLARED AN EMERGENCY WITH ATC,…
- 24 Feb 2005
Carbon Seal, leaking
EVENT SUMMARY STATED LAV SMOKE. REMOVED AND REPLACED RT ENG NR 1 CARBON SEAL.
- 18 Feb 2005
Smoke Warning, false activation
SMOKE TOILET MESSAGE ON CLIMB PHASE. MX RAN ENGINES AND GOT MESSAGE WHEN RT ENGINE PACK ON. REMOVED AND REPLACED HEAT EXCHANGER, ACM, AIR CONDITIONER CONTROL…
- 17 Feb 2005
Structure, burned
EVENT SUMMARY STATED LAV SMOKE IND, EMERGENCY DECLARED. PERFORMED ENG AND APU RUNS. COULD NOT DUPLICATE SMOKE. INSPECTED AND FOUND LAV WALL BEHIND ORDINANCE…
- 26 Jan 2005
Duct, contaminated
EVENT SUMMARY STATED LAV SMOKE MSG. OPERATED A/C OFF BOTH ENGINES AND APU. NOTED SLIGHT GLYCOL SMELL. REMOVED AND REPLACED SOCKS AND CLEANED EXTERNAL RESIDUE…
- 15 Jan 2005
Warning Light, false indication
EVENT SUMMARY STATED LAV SMOKE INDICATION. INSPECTED BOTH PACKS AND WATER SOCKS. NO DEFECTS NOTED. INSPECTED LAV LIGHTS. NO DEFECTS FOUND. PERFORMED EXTENSIVE…
- 26 Apr 2004
Bulb, burned out
DURING INSPECTION THE CEILING EMERGENCY LIGHT A ROW 8 WAS FOUND INOPERATIVE AND REPLACED. A SATISFACTORY OPERATIONAL CHECK WAS PERFORMED AND AIRCRAFT WAS…
- 25 Feb 2004
Coalescer Bag, dirty
DURING CLIMB OF 7790 CREW REPORTED A TOILET SMOKE MESSAGE. FLIGHT RETURNED TO FIELD AND LANDED UNEVENTFULLY. THE COALESCER BAG WAS FOUND DIRTY AND REPLACED. A…
- 17 Feb 2004
Smoke Detector, false activation
DURING CLIMB OF FLIGHT 7375 CREW REPORTED A LAVATORY SMOKE INDICATION. THE SMOKE DETECTOR WAS FOUND TO BE PROVIDING A FALSE INDICATION AND WAS REPLACED. A…
- 10 Feb 2004
Structure, cracked
DURING INSPECTION A CRACK WAS FOUND AT STATION 621 WATER LINE 73 UNDER FLOOR PANEL 282. THE CRACK WAS REPAIRED AND AIRCRAFT WAS RETURNED TO SERVICE UPON…
- 29 Jul 2003
Light, inoperative
DURING MAINTENANCE INSPECTION THE LT EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LT EMERGENCY LIGHT. A SATISFACTORY…
- 4 Jun 2003
Lamp, inoperative
DURING MAINTENANCE INSPECTION, THE NR 3 RT EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LAMP IN THE…
- 22 Apr 2003
Lamp, inoperative
DURING PREFLIGHT INSPECTION, THE CREW REPORTED THAT THE LT EXTERIOR EMERGENCY EXIT LIGHT WAS INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE LAMP…
- 21 Apr 2003
Escape Rope, missing
DURING PREFLIGHT INSPECTION, THE CREW REPORTED THAT THE HOOK FOR THE EMERGENCY ESCAPE ROPE WAS MISSING. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE…