- 16 Sep 2026
Adm, faulted
FLT 1196, FLL-FLL. REF ITEM 1 LG 4424380 ACCOMPLISHED STBY ACCURACY CK OF ADM #3 & STBY FOUND ADM#3 455HPA IS 21,540 FT SHOULD BE 20,000FT CAS IS 340 KTS…
- 6 Sep 2026
Engine, odor
FLT 407, PWM-JFK. DIRTY SOCKS ODOR OBSERVED DURING CRUISE BY INFLIGHT. RAN ODOR ISOLATION CHECKLIST & ISOLATED PACK 2. LEVEL 2 EVENT 3RD EVENT SINCE 9/2/26;…
- 2 Sep 2026
A/C Pack, contaminated
FLT 2433, DCA-DJT. LEVEL 1 ODOR NOTICED ON FLIGHT DECK DURING IDLE DESCENT AT FL250 IN IMC. DISSIPATED AFTER PACK 1 WAS TURNED OFF. COMPLIED WITH INFORMATION…
- 21 Mar 2026
Apu, contaminated
FLT 610. SDQ-JFK, ( APU BLEED AIR SUPPLY SYSTEM ) FA'S REPORTED FUMES SIMILAR TO HYD FLUID ON T/O FROM SDQ THAT STARTED IN THE AFT SEC OF D/C. SAME THING…
- 19 Feb 2026
Unknown, odor
FLT 321, BOS-PBI, STRONG DIRTY SOCKS ODOR IN AFT GALLEY WHILE DESCENDING THROUGH 10,000' THROUGH LANDING. ODOR WAS TEMPORARY AND DISAPPEARED AFTER LANDING AS…
- 5 Feb 2026
Unknown, odor
FLT 1676, KIN- FLL, CREW REPORTS ODOR SIMILAR TO DIRTY SOCKS IN CABIN NEAR ROW 5 APU RUNNING WITH BLEED ON.; COMPLIED WITH INFO NOTICE 2017-T015, STEP Q…
- 13 Aug 2025
Engine, failed
FLT#547, ISP-MCO. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO JFK, AFTER T.O. ENG #2 FAIL. OPEN
- 10 Mar 2024
A/C Pack, odor
FLT#1287, PVD-PBI. 'DIRTY SOCKS SMELL ON CLIMB OUT OF PVD AND DESCENT INTO PBI STRONG THROUGH 10,000 PACK #1 ISOLATION IMPROVED. MILD ON CLIMB OUT THEN…
- 27 Nov 2023
Unknown, unknown
FLT#2357, EWR-MBJ. " DIRTY SOCK SMELL ( APU BLEED AIR SUPPLY SYSTEM ); PERFORMED APU BLEED OPS CHECK FOR APPROX 2 HRS ON FULL HOT. COULDNT DUPLICATE ANY TYPE…
- 24 May 2023
Windshield, leaking
FLT#1499, FLL-HAV. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) 'WHILE CLIMBING ABOVE 10000A LOUD HIGH-PITCHED WHISTLE STARTED IN THE COCKPIT AND LEVELED OFF…
- 22 Nov 2021
Actuator, failed
FLT 237, JFK-STI (AIR TURN BACK TO JFK) ENG 1 COMPRESSOR VANE ECAM APPEARED DURING INITIAL TAKEOFF ROLL: A LOW-SPEED RTO WAS ACCOMPLISHED; T/S PER TSM…
- 15 Jul 2021
Warning Message, illuminated
FLT 1519, BOS-SEA. RETURNED BACK TO BOS, EXCESSIVE CAB ALT, WARNING AT 25000FT, EMERGENCY DESCENT. SUPPLEMENTAL INFORMATION TO FOLLOW
- 15 Jul 2021
Ecs, contaminated
FLT 400, MSY-BOS. DIRTY SOCK SMELL ON DECENT, LASTED FOR COUPLE MINUTES ODOR REPORT FILLED OUT ; DETERMINED EVENT TO BE LEVEL A PER TSM 05-50-00-810-831A.…
- 17 May 2021
Battery, failed
FLT# 310, PAP-FLL. EMER BATTERY CAPACITY EPSU 1 FWD LEFT FAIL MSG ; REM&REP EPSU 1 FWD LEFT BATTERY IAW AMM 33-51-38. SYS TEST OK ON PTP. A/C OK FOR CONTINUED…
- 11 Jan 2021
Inlet, contaminated
FLT 512, AUS - FLL. DIRTY SOCK SMELL WHEN USED APU BLEED, SMELL TRANSIENT & SUBSIDED AFTER CLIMBOUT, SMELL PRESENT BOTH COCKPIT & CABIN. UPON INITIAL…
- 27 Jan 2020
Battery, no test
BATTERY CAPACITY CHECK FAILED A CAPACITY CHECK. R & R THE BATTERY IAW 33-51-38 OPS CHECKED GOOD. ACFT OK FOR SERVICE.
- 27 Jan 2020
Battery, failed
BATTERY CAPACITY CHECK FAILED.
- 27 Jan 2020
Battery, no test
BATTERY CAPACITY CHECK 11WL. FAILED. R & R.
- 27 Jan 2020
Battery, no test
BATTERY CAPACITY CHECK FAILED 12WL. R & R.
- 30 Dec 2019
Skin, gouged
DURING HEAVY MAINTENANCE, GOUGE - EXTERNAL SKIN FR64 +20" STR26L; (REF AEROMAN NR 2019-400559) PERFORMED REPAIR ON EXTERNAL SKIN FR64 +15" TO FR65 +2" AND…
- 14 Apr 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LEFT SIDE FLOOR SUPPORT Y1292 AT FRAME 16, AND FRAME 18. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM…
- 14 Apr 2018
Shear Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE RT SHEAR WEB, FRAME 69 + 16. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REPLACED THE SHEAR WEB…
- 14 Apr 2018
Floor Support, corroded
CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT, Y765, FRAME 68. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-72-11-911-001.
- 14 Apr 2018
Floorbeam, corroded
CORROSION DISCOVERED ON THE FLOORBEAM, FRAME 68. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11-911-001.
- 14 Apr 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION DISCOVERED INSIDE CABIN AT THE R2 DOOR SILL, FRAME 66, STRINGER 23R. REMOVED AND REPLACED AFT PAX DOOR SILL IAW SRM…
- 14 Apr 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION DISCOVERED INSIDE CABIN, LEFT SIDE Y1292, FRAME 68. REMOVED AND REPLACED THE CABIN FLOORBEAM IAW SRM 51-42-11, AND 51-72-11.
- 14 Apr 2018
Battery Pack, no test
DURING HEAVY MAINTENANCE, EPSU BATTERY 11WL FAILED AN EMERGENCY LIGHT TEST. R & R THE EPSU BATTERY 11WL IAW AMM 33-51-38, EMERGENCY LIGHT SYSTEM CHECKED OK.
- 14 Apr 2018
Skin, chafed
DURING HEAVY MAINTENANCE, THE NR 2 PYLON LOWER SKIN SURFACE FOUND CHAFED, INCLUDING THE HORIZONTAL DOUBLER AT RIB 5. REPAIRED THE NR 2 PYLON LOWER SKIN RIB 5…
- 14 Apr 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE BEAM Y1292 AT THE FOLLOWING LOCATIONS FRAME 16 & FRAME 18 23L. REMOVED AND…
- 14 Apr 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE BEAM Y1292 AT THE FOLLOWING LOCATIONS FRAME 16 & FRAME 18 23L. REMOVED AND…
- 14 Apr 2018
Shear Plate, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN RT SHEAR WEB FRAME 69+16" STR 23R. REMOVED CORROSION ON RT SHEAR PLATE AT FRAME 69+16"…
- 14 Apr 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT OF CABIN Y765 STR 23 LT FRAME 68. REMOVED AND REPLACED FLOORBEAM Y765 P/N…
- 14 Apr 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE OF CABIN Y1292 STR23L FRAME 68. REMOVED AND REPLACED LEFT SIDE OF CABIN FLOORBEAM…
- 14 Apr 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN R2 DOOR SILL AT FR 66 STR 23R. REMOVED CORROSION VERIFIED BEYOND 25% ALLOWABLE LOSS LIMITS…
- 14 Apr 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT PASSENGER DOOR RT FR 66 LOWER CORNER STRUCTURE FWD IB BOLT HOLES. REMOVED AND REPLACED AFT PASSENGER…
- 14 Apr 2018
Spar, gouged
DURING C6 CHECK (LCQ), A GOUGE WAS FOUND ON THE LOWER SPAR WEB (PN: D54610003206) AT RIB 5 ON THE RT PYLON. SEE REF /1/ REO FOR MORE DETAILS. THE GOUGE DAMAGE…
- 15 Mar 2018
Battery Pack, no test
EPSU BATTERY 11WL FAILED AN EMERGENCY LIGHT SYSTEM TEST. R & R THE BATTERY IAW AMM 33-51-38. CHECKED OK.
- 28 May 2017
Battery, failed
EMERGENCY LIGHT BATTERY FAULT AT 12WL. R & R EMERGENCY LIGHT BATTERY IAW AMM 33-51-38.
- 28 May 2017
Battery, failed
EMERGENCY LIGHT BATTERY FAULT AT FIN 13WL. R & R EMERGENCY LIGHT BATTERY IAW AMM 33-51-38.
- 16 Mar 2016
Light, malfunctioned
EMERGENCY LIGHTS WERE ILLUMINATED AFTER PUSH BACK. EVENTUALLY RESET WAS SUCCESSFUL. ACCOMPLISHED CABIN EMERGENCY LIGHT OPS CHECK IAW AMM 33-51-00. COULD NOT…
- 12 Mar 2016
Relay, malfunctioned
EMERGENCY LIGHTS STAY ON WHEN SWITCH IS IN ARMED POSITION. R & R RELAY 8WL IAW ESPM 20-46-50, EMERGENCY LIGHTS, OPS CHECK NORMAL IAW AMM 33-51-00.
- 9 Jul 2015
Seal, leaking
RETURNED TO DEPARTURE, EXCESSIVE CABIN ALTITUDE RECEIVED ON ECAM. TROUBLESHOOT IAW TSM 21-31-00-810-809-A , PRESSURIZED ACFT, FOUND AFT CARGO DOOR SEAL…
- 12 Feb 2015
Fan, failed
RETURNED TO DEPARTURE DUE TO STRONG ODOR IN THE CABIN THAT SMELLED LIKE BURNING PLASTIC SHORTLY AFTER TAKEOFF. THE ODOR BEGAN TO DISSIPATE THEN RETURNED.…
- 8 Sep 2014
Battery Pack, failed
DURING MAINTENANCE, RT EMERGENCY LIGHT BATTERY FAILED CAPACITY TEST. R & R RT EMERGENCY LIGHT BATTERY IAW AMM 33-51-00 BITE TEST OK AND OPS CHECK GOOD, REF…
- 8 Sep 2014
Battery Pack, no test
DURING MAINTENANCE, LEFT EMERGENCY LIGHT BATTERY FAILED CAPACITY TEST. R & R LT EMERGENCY LIGHT BATTERY IAW AMM 33-51-00, BITE TEST OK AND OPS CHECK GOOD, REF…
- 28 Mar 2014
Display, odor
DURING MAINTENANCE, IT WAS NOTED THERE IS A POSSIBLE ODOR OF SMOKE OR BURNING IN THE CABIN. PERFORMED ELECTRIC ODOR INTEGRITY CHECK IAW AMM 23-39-00, SECTION…
- 23 Apr 2012
Cable, malfunctioned
FLT 6447 JFK-LCQ, ON HEAVY MAINTENANCE CHECK FOUND LT OVERWING SLIDE CABLE FAILED TO TRAVEL REQUIRED DISTANCE DURING FUNCTIONAL TEST. LT OVERWING SLIDE…
- 23 Apr 2012
Cable, malfunctioned
FLT 6447 JFK-LCQ, ON HEAVY MAINTENANCE CHECK FOUND RT OVERWING SLIDE CABLE FAILED TO TRAVEL REQUIRED DISTANCE DURING FUNCTIONAL TEST. RT OVERWING SLIDE…
- 22 Jan 2011
Cable, out of adjust
FLT 6407 JFK-LCQ, ON MAINTENANCE CHECK FOUND LT OVERWING EMERGENCY EXIT SLIDE DEPLOY CABLE REQUIRES ADJUSTMENT AND FUNCTIONAL CHECK. ACCOMPLISHED ADJUSTMENT…
- 22 Jan 2011
Control Cable, out of adjust
FLT 6407 JFK-LCQ, ON MAINTENANCE CHECK FOUND AFT RIGHT OVERWING DEPLOY CABLE REQUIRES ADJUSTMENT AND FUNCTIONAL TEST. ADJUSTED RT OVERWING FLEX CONTROL CABLE…
- 8 Aug 2009
Unknown, odor
FLT 729 - MCO-JFK - AFTER DEPARTURE AND PASSING THROUGH 26000 FT, NOTIFIED BY F/A NR 1 THAT THERE WAS AN ELECTRICAL FUME SMELL IN THE AFT PART OF THE CABIN,…
- 5 Oct 2007
Controller, malfunctioned
CABIN PRESSURE EXCEEDS CAB ALT ECAM AT FLT LEVEL 340. TROUBLESHOT ITEM PER FIM, FOUND NR 1 CPC AT FAULT. REMOVED AND REPLACED CPC IAW AMM 21-31-34-04, ALL…
- 2 Apr 2007
Rudder, malfunctioned
FLIGHT 727, JFK-BQN, ON CLIMBOUT IN STRAIGHT FLIGHT THE A/C HAD TO HOLD 5 DEGREES LEFT BANK TO MAINTAIN HEADING. SAME ON AUTOPILOT OR HAND FLYING. AFTER 20…