18 reports
- 25 Feb 2009
Warning Light, illuminated
FLIGHT 5992 HOT TO YUL - DURING CRUISE, THE CREW RECEIVED A MASTER CAUTION FOR LEFT PACK HIGH PRESSURE. THE FLIGHT DIVERTED TO SDF AND LANDED WITHOUT…
- 27 Oct 2008
Controller, defective
FLIGHT 5585, CLE TO RDU. DURING CRUISE THE FLIGHT CREW RECEIVED A RIGHT WINDOW HEAT EICAS MESSAGE. THE QRH PROCEDURE WAS FOLLOWED BUT THE MESSAGE REMAINED.…
- 18 Feb 2008
Selector Valve, malfunctioned
IAH TO CRP - ON TAKEOFF, WHEN THE LANDING GEAR LEVER WAS SELECTED UP THE CREW RECEIVED A LANDING GEAR DISAGREE MESSAGE AND THE NOSE LANDING GEAR RETRACTED AND…
- 28 Jan 2007
Unknown, vibration
FLIGHT 3257 - IAH-MSP - WHILE CLIMBING THROUGH 3,000 FEET, RECEIVED MULTIPLE "STALL FAIL" MESSAGE ON THE EICAS. THROUGH 3,500 FEET, HEARD A NOISE IN THE FRONT…
- 17 Dec 2005
Engine, malfunctioned
RIGHT ENGINE LOW OIL PRESSURE ON DESCENT 25PSI, ENGINE SHUTDOWN.
- 27 Feb 2005
Smoke Detector, malfunctioned
EVENT SUMMARRY STATED LAV SMOKE INDICATION, NO SMOKE PRESENT, RAN QRH. REMOVED AND REPLACED LAV SMOKE DETECTOR.
- 18 Dec 2004
Windshield, cracked
CA'S WINDSHIELD OUTER PANE CRACKED. NO PRESSURIZATION ISSUES. MX REMOVED AND REPLACED WINDSHIELD.
- 12 Nov 2004
Warning System, activated
CREW REPORT STATED THAT STAB/MACH TRIM CAUTION MESSAGE DURING DESCENT INTO IAD. PERFORMED BITE SYSTEM TEST OF STAB/MACH TRIM IAW MM 27-41-00.
- 2 Aug 2004
Trim System, inoperative
STAB TRIM FAIL EN ROUTE. FOLLOWED QRH AND LANDED AT NEAREST SUITABLE LOCATION, DECLARED EMERGENCY.
- 12 Apr 2004
Control Unit, inoperative
DURING CRUISE OF FLIGHT 7823 CREW REPORTED A STAB/MACH TRIM FAILURE. CREW DIVERTED TO NEAREST SUITABLE AIRPORT AND FLIGHT LANDED SAFELY. THE HORIZONTAL…
- 27 Dec 2003
Bulb, burned out
DURING INSPECTION THE LT OVERWING EMERGENCY LIGHT WAS FOUND INOPERATIVE. THE BULB WAS FOUND BURNT OUT AND WAS REPLACED. A SATISFACTORY OPERATIONAL CHECK WAS…
- 17 Sep 2003
Bulb, burned out
DURING INSPECTION THE RIGHT HAND EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE EMERGENCY LIGHT. A SATISFACTORY…
- 23 Aug 2003
Light, inoperative
DURING MAINTENANCE INPSPECTION THE RT OVERWING EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE OVERWING EMERGENCY…
- 12 Jul 2003
Light, inoperative
DURING OVERNIGHT MAINTENANCE THE FORWARD EMERGENCY LIGHT WAS DISCOVERED TO BE INOPERATIVE. MAINTENANCE PERSONNEL RELAMPED THE FOWARD EMERGENCY LAMP. A…
- 9 Nov 2002
Lamp
During overnight maintenance it was discovered that the aft aisle emergency exit light was inoperative. Maintenance personnel removed and replaced the lamp in…
- 10 Apr 2002
Heat Exchanger, defective
DURING CRUISE OF THE FLIGHT FROM ORD TO JAX, THE NR 1 HYDRAULIC SYSTEM INDICATED AN OVERHEAT. THE CREW FOLLOWED THE QRH PROCEDURES, SHUT DOWN THE NR 1 ENGINE…
- 29 Mar 2002
Transducer
During cruise of the flight, the crew noted the #1 hydraulic temperature at greater than 178 degrees C. The crew followed the QRH procedures shutting down the…
- 24 Feb 2002
Reservoir
One half hour into the flight from GSP to ORD, the crew noted a hydraulic high temperature caution. Hydraulic temperature reached 200 degrees C. The crew…