- 3 Aug 2023
incident, Jacksonville FL
service difficulty reports
55 reports
- 3 Jul 2025
A/C Pack, contaminated
FLT#591, BOS-, "PACK 1 POSSIBLE OIL CONTAMINATION "DIRTY SOCK" ODOR IN COCKPIT WHEN PACK 1 IS ON; C/W INFO NOTICE 2017-T015, SECTION A, ISOLATED FAULT TO TYPE…
- 5 Jun 2025
Controller, failed
FLT#991, FLL-SJU. (AIRCRAFT DECLARED AN EMERGENCY INTO SJU) 'IN CRUISE AL FL 350- ECAM-CAB PR SYS 2 FAULT; REMOVED AND REPLACED CPC-2 REF AMM 21-31-34 OPS…
- 14 May 2025
Filter, odor
FLT#1885, BUF-MCO. 'DETECTED IN COCKPIT AND CABIN SELECTED PACK 1 OFF AND ODOR ABATED ODOR WAS MUSTY AND SMELLED OF MELTING CRAYONS; PERFORMED TROUBLESHOOTING…
- 16 Apr 2025
Unknown, odor
FLT#2818, JFK-BOS. PERSISTENT LEVEL 1 PUNGENT ODOR TAXI OUT, TAKEOFF, CLIMB,DESCENT, TAXI IN.ENGINES STARTED ON APU. NO MOISTURE. FA'S DID NOT OBSERVE;…
- 5 Apr 2025
Apu Bay, contaminated
FLT#1793,JFK-SFO. 'DIRTY SOCK / MUSK SMELL IN COCKPIT AND MID CABIN ( APU SYSTEM ); REMOVED AND REPLACED COOLING FAN ASSY (8053KM) IAW AMM 49-52-51 OPS CHK…
- 1 May 2024
Skin, corroded
DURING HEAVY MAINTENANCE: WINGS / CENTER WING BOX / RH TOP SKIN BTWN FR 41-42 & BTWN BEAM -Y1292 - RIB 1 / CORROSION - PERMANENT REPAIR (CONSIDERED A MAJOR…
- 1 May 2024
Attach Bracket, corroded
DURING HEAVY MAINTENANCE: CORROSION RETRACTION ACTUATOR ATTACHMENT BRACKET ON LH MLG. (CPCP RELATED); "REF AEROMAN NR 2024-168957 WO 2024 45/1 REPAIRED BORE,…
- 1 May 2024
Skin, corroded
DURING HEAVY MAINTENANCE: CORROSION ON TOP EXTERNAL SKIN CENTER FUEL TANK BTW FR 41 TO FR 42 AND BTW -Y1292 TO -Y1732 PASSENGER CABIN; REF AEROMANM NR…
- 1 May 2024
Shear Tie, corroded
DURING HEAVY MAINTENANCE: CORROSION SHEAR TIE LOCATED AT FR 34 BTW STR. 43R AND STR 44 IN FWD CA RGO COMPARTMENT; REF AEROMAN NR 2024-168821 WO 2024 45/1…
- 1 May 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON BOTH FRAME SEGMENTS (1), FWD RH EMERGENCY EX IT DOOR (843) CRACK LENGTH: 0.812 INCH; REF AEROMAN NR…
- 1 May 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON AFT FRAME SEGMENT (1) AFT RH DOOR EMERGENCY EXIT (844) CRACK LENGTH: 0.4375 INCH; REF AEROMAN NR…
- 1 May 2024
Shear Tie, corroded
DURING HEAVY MAINTENANCE: CORROSION SHEAR TIE LOCATED AT FR 31 BTW STR 42R AND STR 43R IN FWD CA RGO COMPARTMENT (CPCP RELATED REFER TOTHE MPD TASK…
- 1 May 2024
Shear Tie, corroded
DURING HEAVY MAINTENANCE: CORROSION SHEAR TIE LOCATED AT FR 33 AND BTW STR 43L AND STR 43R IN FWD CARGO COMPARTMENT (CPCP RELATED REFER TO THE MPD TASK…
- 1 May 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FWD FRAME SEGMENT (1) FWD LH DOOR EMERGENCY EXIT (833) CRACK LENGTH: 0.500 INCH; REF AEROMAN NR…
- 1 May 2024
Stop Fitting, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR 68 RH SIDE, DOOR STOP FITTING 1 HOLE INBOARD LO WER. CRACK DIRECTION 6 O'CLOCK (VIEW LOOKING AFT); (RESOLVED…
- 1 May 2024
Support, corroded
DURING HEAVY MAINTENANCE: CORROSION LOWER SILL BTW FR 66 TO FR 68 AND AT LEVEL STR 23L AFT GALLE Y AREA (CPCP RELATED REFER TO THE MPD TASK 534195-01); REF…
- 1 May 2024
Stop Fitting, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR68 LH SIDE DOOR STOP FITTING 1 HOLE INBOARD LOWE R. CRACK DIRECTION 10 OCLOK (THIS TASK CARD IS GENERATED FOR…
- 1 May 2024
Stop Fitting, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR 68 LH SIDE DOOR STOP FITTING 1 HOLE INBOARD LOW ER CRACK DIRECTION 10 OCLOCK; (RESOLVED ON W/O: 1292908…
- 1 May 2024
Stop Fitting, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FR 68 LH SIDE, DOOR STOP FITTING 1 HOLE INBOARD LO WER. CRACK DIRECTION 10 OCLOCK ( VIEW LOOKING AFT; (RESOLVED…
- 1 May 2024
Crossbeam, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 CROSSBEAM AREA LH SIDE HOLE H2 FWD GALLEY AREA; AEROMAN REPAIRED DISCREPANCY ON W/O 2024 45/1 N/R…
- 18 Oct 2023
Unknown, unknown
FLT#8358, BOG-FLL. 'DIRTY SOCKS ODOR ON DESCENT; ACCOMPLISHED INFOR NOTICE 2017-T015J PERFORMED A LEVEL C DECONTAMINATION USING ENGINE 1 AND 2 BLEED IAW TSM…
- 28 Sep 2023
Pressure Switch, failed
FLT#2604, SDQ-EWR. (AIRCRAFT DIVERTED TO JFK) 'IN CRUISE- ECAM HYD RES G LO LVL INDICATED TOP OF AMBER BOX; REMOVED AND REPLACED GREEN HYDRO PRESS SWITCH FIN…
- 29 Aug 2023
Unknown, unknown
FLT#348, SLC-BOS. 'CHEMICAL SMELL LIKE DEICING FLUID ON DESCENT PASSING THROUGH 13,000 UNTIL LANDING; COMPLIED WITH INFO NOTICE 2107-T015 SECTION A ISOLATED…
- 16 Aug 2023
Solenoid, failed
FLT#1233, MCO-SJU. (AIRCRAFT PERFORMED AN AIR TURN BACK) ' ON TAKEOFF, TOGA, ENG #2. AFTER ROTATION ON INITIAL CLIMBOUT ENGINE #2 "CYCLED AT LEAST 3 TIMES W/…
- 3 Aug 2023
Unknown, unknown
FLT#18, FLL-JAX. 'DUAL GEN FAIL ON SHORT FINAL RAT EXTENDED.' (SUPPLEMENTAL INFORMATION TO FOLLOW)
- 1 May 2022
None, failed
FLT#2752, SJU-TPA. ' EMERG LIGHT BATTERY 11WL FAILED TEST; REMOVED AND REPLACED EMERG LIGHT BATTERY 11WL IAW AMM 33-51-38.'
- 1 Feb 2022
Unknown, odor
FLT # 2693, JFK-MIA. DURING APPROACH AT 1500FT THE INFLIGHT CREW CALLED AND ADVISED OF A DIRTY SOCK SMELL VERY STRONG FROM THE EMERGENCY EXIT ROW REARWARD ;…
- 13 Apr 2021
Slide, deformed
DURING HEAVY MAINTENANCE, DEFORMATION SLIDE RAFT ON FUSELAGE WHEN THE DOOR IS FULLY OPENED AND L OCKED DUE TO SWELLING AT PASSENGER CREW DOOR 841 AT FWD…
- 11 Dec 2019
Power Supply, no test
DURING HEAVY MAINTENANCE, EMERGENCY POWER UNIT EPSU 11WL IN PASSENGER CABIN DOES NOT PASS TEST; REF AEROMAN N/R 2019-363259 - THE VISUAL INSPECTION OF THE…
- 2 Dec 2018
A/C Pack, odor
FT 861, BOS-SJU. FUME/ODOR (SOCK ODOR) REPORTED BY CABIN CREW DURING DESCENT OUT OF 15000' ENG BLEED USED (APU OFF). C/W INFORMATION NOTICE 2017 SECTION A.…
- 5 Jul 2018
Battery, discharged
FLT 788, SXM-JFK. EMERGENCY LIGHT INOP IN A/C. MULTILE CABIN LGHTS INOP. INSPECTED CABIN EMERGENCY LIGHTS UNITS AND FOUND ALL CABIN EMERGENCY BATTERIES AT…
- 5 Jul 2018
Battery, discharged
FLT 788 SXM-JFK. EMERGENCY LIGHT INOP IN A/C. INSPECTED CABIN EMERGENCY LIGHTS UNITS AND FOUND ALL CABIN EMERGENCY BATTERIES AT FAULT. REMOVED AND REPLACED…
- 5 Jul 2018
Battery, discharged
FLT 788, SXM-JFK. EMERGENCY LIGHT INOP IN A/C. INSPECTED CABIN EMERGENCY LIGHTS UNITS AND FOUND ALL CABIN EMERGENCY BATTERIES AT FAULT. REMOVED AND REPLACED…
- 5 Jul 2018
Battery, discharged
FLT 788, SXM-JFK. EMERGENCY LIGHT INOP IN A/C. INSPECTED CABIN EMERGENCY LIGHTS UNITS AND FOUND ALL CABIN EMERGENCY BATTERIES AT FAULT. REMOVED AND REPLACED…
- 23 Mar 2018
Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SUPPORT, FRAME 61 + 9 AND 62, STRINGER 38R, IN THE BULK CARGO BAY. PERFORMED REPAIRS ON THE LOWER…
- 23 Mar 2018
Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SUPPORT, FRAMES 61 + 9 AND 62, STRINGER 38R IN THE BULK CARGO BAY. PERFORMED REPAIRS IAW SRM…
- 23 Mar 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT, +Y765 BETWEEN FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, DRAWING…
- 23 Mar 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT, + Y765, AT FRAME 16 + 2. REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 12 - 24 IAW SRM…
- 23 Mar 2018
Door Sill, corroded
DURING C6 CHECK ON AIRCRAFT AT (SAL) DATED 03/18, CORROSION WAS FOUND ON THE BULK CARGO DOOR SILL BTWN FR61-62 & STR 37-38R AT THE AFT FUSELAGE. SEE REF /1/…
- 25 Jan 2018
Unknown, odor
STRONG ACRID ODOR APPARENT DURING DESCENT AT 1100 FT, BOTH PILOTS OBSERVED ODOR BUT CABIN DID NOT. PERFORMED AN OPS CHECK IAW AMM 12-33-21. NO ODORS NOTED.…
- 2 Sep 2017
Condenser, contaminated
FLIGHT ATTENDANT SMELLED A DIRTY SOCK ODOR AFTER APU BLEED AIR TURNED ON. THE ODOR WAS DETECTED RIGHT AFTER TAKEOFF AND 1:36 HOURS INTO FLIGHT, DESCENDING +20…
- 2 Sep 2017
Condenser, contaminated
FLIGHT ATTENDANT SMELLED A DIRTY SOCK ODOR AFTER APU BLEED AIR TURNED ON. THE ODOR WAS DETECTED RIGHT AFTER TAKEOFF AND 1:36 HOURS INTO FLIGHT, DESCENDING +20…
- 2 Sep 2017
Fan, failed
FLIGHT ATTENDANT SMELLED A DIRTY SOCK ODOR AFTER APU BLEED AIR TURNED ON. THE ODOR WAS DETECTED RIGHT AFTER TAKEOFF AND 1:36 HOURS INTO FLIGHT, DESCENDING +20…
- 2 Sep 2017
Filter, dirty
FLIGHT ATTENDANT SMELLED A DIRTY SOCK ODOR AFTER APU BLEED AIR TURNED ON. THE ODOR WAS DETECTED RIGHT AFTER TAKEOFF AND 1:36 HOURS INTO FLIGHT, DESCENDING +20…
- 2 Sep 2017
Filter, dirty
FLIGHT ATTENDANT SMELLED A DIRTY SOCK ODOR AFTER APU BLEED AIR TURNED ON. THE ODOR WAS DETECTED RIGHT AFTER TAKEOFF AND 1:36 HOURS INTO FLIGHT, DESCENDING +20…
- 9 Aug 2017
Hydraulic System, leaking
DIVERTED, AT DEPARTURE ALL HYDRAULIC SYS INDICATED FULL. WHILE ENROUTE HYD G RESERVOIR INDICATES APPROX 1/8 ABOVE AMBER, LOW INDICATION. QTY REDUCTION WAS…
- 28 Sep 2016
Battery Pack, failed
DURING MAINTENANCE, EMERGENCY LIGHT WAS TESTED AND FAILED TEST. R & R BATTERY PACK AT FORWARD, 10WL AND AFT, 13WL IAW AMM 33-51-38. PERFORMED SECOND TEST.…
- 28 Sep 2016
Battery Pack, failed
DURING MAINTENANCE, EMERGENCY LIGHT WAS TESTED AND FAILED TEST. R & R BATTERY PACK AT FORWARD 10WL AND AFT 13WL IAW AMM 33-51-38. PERFORMED SECOND TEST. LIGHT…
- 5 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT Y765 AFT OF FRAME 67+3". REMOVED AND REPLACED THE FLOOR SUPPORT.
- 5 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT Y1292 AFT OF FRAME 67+5. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 5 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOORBEAM Y765 AT FR 68. REMOVED AND REPLACED THE FLOORBEAM.
- 5 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FWD CABIN FLOORBEAM Y503 AT FRAME 16 AT LAV MOUNT. R & R THE FLOORBEAM.
- 5 Aug 2016
Shear Web, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON RT SHEAR WEB FRAMES 69-70 AT STR 23R. R & R THE SHEAR WEB.
- 16 Aug 2012
Coffeemaker, failed
FLT 171 JFK-SMF, FLIGHT CREW REPORTED ELECTRICAL SMELL IN AFT COFFEE POT AREA. REMOVED POWER AND PULLED 3 CB'S AND SMELL DISSIPATED. ACCOMPLISHED TSM…
- 27 Dec 2008
Entertain Sys, obstructed
FLT NR 718, SJU-JFK, ENROUTE AT FL360 FA'S SMELLED A BURNING RUBBER SMELL BETWEEN ROWS 11-16 NEAR TOP OF AC. SMELL WAS EVIDENT FOR APPROX 15 MINUTES, THEN…