N648AA
1991 Boeing 757-223 standard FAA →
earlier registrations
1 past record
- 1991
service difficulty reports
69 reports
- 30 Apr 2011
Pump, inoperative
TUL (REPEAT ITEM) CREW REPORTED DURING FUNCTIONAL CHECK FLIGHT RIGHT ENGINE FAILED TO RESTART (SINGLE ENGINE TIME 23 MIN). NO FUEL WAS DISPLAYED WITH FUEL…
- 28 Apr 2011
Governor, malfunctioned
TUL (REPEAT ITEM) CREW REPORTED DURING FUNCTIONAL CHECK FLIGHT RIGHT ENGINE WAS SHUT DOWN AND ENGINE WOULD NOT RESTART (SINGLE ENGINE TIME 18 MINUTES).…
- 26 Apr 2011
Governor, malfunctioned
TUL - CREW REPORTED DURING FUNCTIONAL CHECK FLIGHT WHEN RIGHT ENGINE WAS SHUT DOWN, ENGINE WOULD NOT RE-START (SINGLE ENGINE TIME 12 MINUTES). INDICATION WAS…
- 21 Apr 2011
Floorbeam, gouged
FLOORBEAM GOUGED AT STATION 1707 AT RIGHT BUTTLINES 9 TO 10. INSTALLED REPAIR STRAPS PER SRM 51-10-02-0G WITH MODIFICATIONS PER EA B757-53-016570.
- 21 Apr 2011
Intercostal, cracked
IN THE MAIN EMERGENCY EQUIPMENT BELOW THE CABIN FLOOR AT STATION 418 THE INTERCOSTALS TOP TEE IS CRACKED AT BUTTLINE 0. INSTALLED REPAIR STRAP AND SRM MATING…
- 19 Apr 2011
Floorbeam, cracked
REPAIR 700 BEAM ON LEFT SIDE. PERFORMED NECESSARY REPAIR TO LATERAL FLOORBEAM STATION 700 WATERLINE 208, LEFT BUTTLINES 70 TO 0 BY COMPLETING TASK CARD…
- 19 Apr 2011
Pan, gouged
RIGHT NUMBER 4 DOOR HANDLE PAN GOUGE. INSTALLED NEW HANDLE PAN PER ESO 90108.
- 18 Apr 2011
Shear Tie, corroded
SHEAR TIE STATION 1460 STRINGER 26 CORRODED. ACCOMPLISHED REPAIR PER SRM 51-40-02-0G.
- 15 Apr 2011
Web, corroded
WEB CAP STATION 1480 TO 1500 CORRODED. ACCOMPLISHED REPAIR PER AARD 51-10-05-1.
- 15 Apr 2011
Structure, misinstalled
AFT DECK DOUBLERS NOT INSTALLED PER SRM. INSTALLED REPAIR DOUBLER IAW SRM 53-60-51-2R 2 EA B757-53-016339.
- 12 Apr 2011
Intercostal, corroded
STATIONS 1480 TO 1500 OUTBOARD OF STRINGER 27 RIGHT FLOOR INTERCOSTAL CORRODED. INSTALLED FLOOR INTERCOSTAL PER SRM 51-10-02-0G.
- 8 Apr 2011
Stringer Splice, corroded
STRINGER SPLICE HAS CORROSION ON INNER SURFACE. REMOVED STRINGER SPLICE AND INSTALLED NEW SPLICE.
- 7 Apr 2011
Floor Support, damaged
THIRD FLOORBOARD SUPPORT FROM RIGHT SIDE HAS GAPS BETWEEN REPAIRS AT STATION 555 AND 580. ACCOMPLISHED REPAIR PER SRM 51-10-02-G9.
- 7 Apr 2011
Web, corroded
CORROSION ON OUTBOARD HINGE WEB OF LEFT AILERON UNDER BONDING STRAP. REMOVED WEB AND INSTALLED NEW WEB.
- 6 Apr 2011
Bulkhead, cracked
NUMBER 1 PYLON MID BULKHEAD CRACKED. ACCOMPLISHED REPAIR PER EA 016326.
- 5 Apr 2011
Crease Beam, corroded
CORROSION ON CREASE BEAM STATIONS 1588 TO 1591. REPLACED CREASE BEAM.
- 5 Apr 2011
Channel, corroded
CORROSION ON AFT DECK STIFFENER STATION 1715 BUTTLINE 0. CORROSION REMOVED AND INSTALLED SHIMS AND A NEW HAT CHANNEL AS PER SRM 51-10-02-0G SECTION 9.
- 5 Apr 2011
Stiffener, corroded
CORROSION ON Z-BRACE STIFFENER STATIONS 1712 TO 1685 LEFT BUTTLINE 50. INSTALLED NEW Z-BRACE STIFFENER STATIONS 1712 TO 1685 LEFT BUTTLINE 50 PER SRM…
- 1 Apr 2011
Seat Track, corroded
NUMBER 4 SEAT TRACK STATIONS 667 TO 780 CORRODED. REPLACED SEAT TRACK PER SRM 53-01-02-25.
- 1 Apr 2011
Web, corroded
CORROSION ON TOP AND UNDERSIDE OF WEBBING OF RIGHT NUMBER 1 DOOR THRESHOLD/ DITCHING PANEL BELOW THE CREASE ANGLE, FRAME STATIONS 334 TO 365 RIGHT BUTTLINES…
- 31 Mar 2011
Crease Beam, corroded
CORROSION ON TOP OF RIGHT FLOOR BOARD SUPPORT. REPLACED CREASE BEAM.
- 31 Mar 2011
Seat Track, corroded
NUMBER 3 SEAT TRACK CORRODED. REPLACED SEAT TRACK.
- 31 Mar 2011
Angle, corroded
THE Z-ANGLE INBOARD OF THE RIGHT NUMBER 2 DOOR THRESHOLD IS CORRODED BETWEEN STATIONS 680 TO 740. REPLACED CREASE ANGLE STATIONS 655 TO 760 RIGHT SIDE PER SRM…
- 30 Mar 2011
Floor Support, corroded
THE CABIN LONGITUDAL FLOOR BOARD SUPPORT AT STATION 406 IS CORRODED ON TOP AT 66 INCHES RIGHT BUTTLINE. INSTALLED NEW FLOOR SUPPORT PER SRM 51-10-02-0G.
- 30 Mar 2011
Attach Fitting, corroded
CORROSION ON GALLEY TIE DOWN STATION 1686 RIGHT BUTTLINE 52. REPLACED GALLEY FLOOR FITTING PER SRM 51-10-02-0G.
- 30 Mar 2011
Attach Fitting, corroded
CORROSION ON GALLEY TIE DOWN STATION 1715 RIGHT BUTTLINE 52. REMOVED CORRODED GALLEY TIE DOWN AT STATION 1715 RIGHT BUTTLINE 52 AND INSTALLED NEW MOUNT IAW…
- 29 Mar 2011
Intercostal, cracked
INTERCOSTAL CRACKED BELOW CABIN FLOOR STATIONS 1320 TO 1340. REPLACED INTERCOSTAL.
- 29 Mar 2011
Door, damaged
LEFT NUMBER 4 DOOR INTERIM REPAIR TO INNER SKIN BY THE HINGE ARM. INSTALLED DOUBLER REPAIR PER SRM 51-70-13-0G AND EA COMP-52-016002.
- 28 Mar 2011
Angle, corroded
CREASE ANGLE STATIONS 665 TO 760 CORRODED. REPLACED CREASE ANGLE PER SRM 51-10-2-G9.
- 28 Mar 2011
Beam, corroded
FORWARD CARGO DOOR LOWER EDGE BEAM IS CORRODED AND DAMAGED ALONG ENTIRE LENGTH. REMOVED DAMAGED AND CORRODED EDGE BEAM ,LOCATED AND DRILLED NEW EDGE BEAM AND…
- 28 Mar 2011
Door, dented
DENT ON FORWARD CARGO DOOR 6 INCHES FROM BOTTOM AND 18 INCHES FROM FORWARD EDGE IS BEYOND MANUAL LIMITS. TRIMMED OUT DAMAGED AREA AND INSTALLED DOUBLER PER…
- 28 Mar 2011
Floor Support, corroded
CORROSION ON FLOOR SUPPORT STATIONS 1640 TO 1661 BUTTLINE 0. CORROSION WAS REMOVED BY INSTALLING NEW FLOORBOARD SUPPORT AND INSTALLING NEW FASTENERS PER SRM…
- 25 Mar 2011
Beam, damaged
NUMBER 2 CARGO DOOR LOWER EDGE BEAM IS BENT AND GOUGED IN MULTIPLE AREAS. INSTALLED NEW LOWER EDGE BEAM ON NUMBER 2 CARGO DOOR PER ESO 90121.
- 24 Mar 2011
Pan, gouged
RIGHT NUMBER 1 DOOR HANDLE PAN GOUGED. REPLACED HANDLE PAN PER ESO 90284.
- 23 Mar 2011
Intercostal, bent
NUMBER 2 CARGO DOOR 2ND FROM FORWARD EDGE BEAM SUPPORT INTERCOSTAL IS BENT. REMOVED BENT INTERCOSTAL AND INSTALLED NEW INTERCOSTAL PER ESO 90121.
- 23 Mar 2011
Mount, corroded
GALLEY MOUNT STATION 329 RIGHT BUTTLINE 44 CORRODED. REPLACED MOUNT PER SRM 51-10-02-G14.
- 23 Mar 2011
Support Angle, corroded
FORWARD CARGO DOOR LOWER AFT EDGE BEAM SUPPORT ANGLE CORRODED. REMOVED CORRODED SUPPORT ANGLE, LOCATED AND DRILLED NEW SUPPORT ANGLE AND INSTALLED PER ESO…
- 22 Mar 2011
Mount, corroded
AFT LAVATORY MOUNT CORRODED. REPLACED MOUNT PER SRM 51-10-02-0G.
- 22 Mar 2011
Mount, corroded
AFT INBOARD LAVATORY MOUNT CORRODED. REPLACED MOUNT PER SRM 51-10-02-0G.
- 31 Jul 2010
Computer, inoperative
MIA - CREW REPORTED EICAS DISPLAYS INOPERATIVE WHEN LEFT COMPUTER SELECTED AND BOTH ENGINES FUEL FLOW ERRATIC. EMERGENCY DECLARED, RETURNED MIA LANDED WITHOUT…
- 21 Feb 2010
Duct, blown
MIA - CREW REPORTED AFTER TAKEOFF AIR CONDITIONING DISTRIBUTION DUCT AT ROWS 12 TO 14 BLEW. FLIGHT RETURNED MIA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM…
- 1 Feb 2010
Acm, malfunctioned
DEN - INFLIGHT DFW-HDN - CREW REPORTED HAD SMOKE IN AFT PORTION OF MAIN CABIN. EMERGENCY DECLARED, DIVERTED DEN LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM…
- 17 Jul 2009
Battery Pack, discharged
EMERGENCY LIGHTS INOPERATIVE ROWS 16-25 RIGHT SIDE. REMOVED AND REPLACED BATTERY PACK AND CHARGER M10800 PER M/M. OPS CHECK OK.
- 18 May 2009
Cover, missing
JFK LEFT NUMBER FOUR DOOR EXIT SIGN MISSING COVER. REINSTALLED LEFT NUMBER FOUR DOOR EXIT SIGN COVER.
- 9 Jun 2008
Shroud, damaged
DFW - EMERGENCY LIGHT AT FORWARD SEAT 5E HAS BROKEN SHROUD. REPLACED SHROUD FOR EMERGENCY LIGHT AT FORWARD SEAT 5E. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 3 May 2008
Lens, missing
DFW - EMERGENCY LIGHT ADJACENT TO RIGHT AFT LAVATORY MISSING LENS. REPLACED LENS COVER FOR EMERGENCY LIGHT ADJACENT TO RIGHT AFT LAVATORY. SYSTEM GROUND…
- 3 May 2008
Placard, damaged
DFW - EMERGENCY LIGHT EXIT PLACARD AT RIGHT FORWARD OVERWING DAMAGED. REPLACED PLACARD FOR EMERGENCY LIGHT EXIT PLACARD AT RIGHT FORWARD OVERWING. SYSTEM…
- 3 May 2008
Placard, damaged
DFW - EMERGENCY LIGHT EXIT PLACARD AT LEFT FORWARD OVERWING DAMAGED. REPLACED PLACARD FOR EMERGENCY LIGHT EXIT PLACARD AT LEFT FORWARD OVERWING. SYSTEM GROUND…
- 3 May 2008
Light, inoperative
DFW - EMERGENCY LIGHT AT LEFT NUMBER TWO DOOR INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT LEFT NUMBER TWO DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 30 Aug 2006
Light, inoperative
LAX - EMERGENCY EXIT LIGHT AT LEFT WING INOPERATIVE. RELAMPED EMERGENCY EXIT LIGHT AT LEFT WING. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 28 Mar 2005
Seat Track, corroded
TUL - COFFEE BAR TIE DOWN SEAT TRACK NUMBER 3 AT STATION 686 TO 690 CORRODED. REPLACED COFFEE BAR TIE DOWN SEAT TRACK, ALODINED, PRIMED, AND PAINTED.
- 28 Mar 2005
Intercostal, corroded
TUL - RIGHT NUMBER 4 DOOR DRAIN LINE SUPPORT CORRODED BETWEEN STATION 1640 AND 1661. REPLACED DRAIN LINE SUPPORT INTERCOSTAL WITH A NEW INTERCOSTAL BETWEEN…
- 29 Oct 2002
Light, inoperative
BDL - FOUND SEAT MOUNTED ESCAPE PATH LIGHT ASSEMBLY ON SEAT 14D INOPERATIVE. INSTALLED NEW LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 8 Apr 2002
Light, inoperative
LAX - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 17 May 2001
Battery Pack
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS ROWS 15 THROUGH 23 DIM. REPLACED BATTERY PACK FOR EMERGENCY EXIT ESCAPE PATH LIGHTS.…
- 26 Mar 2001
Duct, leaking
BGI - FLT 984 - EN ROUTE BGI-MIA - DETECTED LOUD NOISE IN CABIN. RETURNED BGI AND LANDED WITHOUT FURTHER INCIDENT. REPLACED AIR CONDITIONING DUCT.…
- 6 Jun 1999
Light Assy, defective
DFW - DURING OVERNIGHT MAINTENANCE, AFT RIGHT OVERWING EMERGENCY EXIT SIGN INOPERATIVE. REPLACED AFT RIGHT EMERGENCY EXIT LIGHT ASSY. SYSTEM GROUND CHECKED…
- 21 Apr 1998
Light Assy, failed
DFW - DURING OVERNIGHT MAINTENANCE CHECK, EMERGENCY EXIT LIGHT AT FORWARD COACH CABIN INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY IN FORWARD COACH CABIN.…
- 13 Dec 1997
Light, broken
ORD - DURING OVERNIGHT CHECK, R4 EMERGENCY EXIT DOOR LIGHT BROKEN. REPLACED R4 EMERGENCY EXIT DOOR LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 7 Dec 1997
Light, defective
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT AT FORWARD EDGE OF R1 DOOR FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT AT FORWARD EDGE OF R1 DOOR.…
- 3 Sep 1996
Connector, loose
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 9 THROUGH 16 INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTOR BY…
- 16 Apr 1996
Floor Beam, corroded
AFW - FLOOR BEAM AT STATION 324 RBL 42 AND RBL 62 HAS CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-777. (M)
- 16 Apr 1996
Floor Beam, corroded
AFW - FOUND FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED AT VARIOUS LOCATIONS MATERIAL REMOVED IS BEYOND SRM LIMITS. MRB 757-778. (M)
- 16 Apr 1996
Deck Plate, corroded
AFW - DECK PLATE HAS CORROSION REMOVAL ON UPPER SURFACE MATERIAL REMAINING AT VARIOUS LOCATIONS ARE BEYOND SRM LIMITS. PER MRB 757-779. (M)
- 16 Apr 1996
Floor Beam, misdrilled
AFW - FLOOR BEAM AT STATION 345 LBL HAS A MISDRILLED HOLE. PER MRB 757-788. (M)
- 16 Apr 1996
Pan, gouged
AFW - FOUND L-4 DOOR HANDLE PAN HAS A GOUGE BLENDED BEYOND SRM LIMITS. PER MRB 757-781. (M)
- 16 Apr 1996
Pan, gouged
AFW - FOUND R-4 DOOR HAS A SMALL GOUGE AFTER BLENDING. BLENDED AREA IS BEYOND SRM LIMITS. PER MRB 757-775. (M)
- 16 Apr 1996
Surround Struct, corroded
AFW - FOUND AFT CARGO DOOR SURROUND STRUCTURE UPPER CHORD HAS CORROSION BLENDED OFF BEYOND SRM LIMITS. PER MRB 757-783. (M)
- 12 Dec 1995
Skin, gouged
AFW - FOUND FUSELAGE SKIN HAS A SMALL BUT DEEP GOUGE AT STATION 1094 AT S10R. PER MRB 757-673, BLENDED PER MRB. PERMANENT REPAIR REQUIRED AT NEXT 'C' CHECK. (M)