N646JB
2006 Airbus A320-232 standard FAA →
registration
- 2006
service difficulty reports
70 reports
- 6 Apr 2026
Battery Pack, no test
FLT 2334, PBI-DCA. FWD LT EMERGENCY LIGHT BATTERY PACK FAILED CAPACITY CHK. REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51-38. OPS CKS GOOD."
- 13 Mar 2026
Sensor, out of adjust
FLT 1799 ORF-FLL. AFT L2 DOOR OPEN DOOR UPON TOUCHDOWN. ( ECAM DOOR PG IND PASSENGER-DOOR ERRONEOUSLY INDICATED OPEN-SLIDE ARMED LIGHT ON DOOR OFF ).;…
- 13 Mar 2026
Drain Valve, leaking
FLT 1799 ORF-FLL. G & B HYD SYSTEM LOW AIR PRESSURE ECAM WHEN APU BLEED DESELECTED. REMOVED AND RELACED GREEN HYDRAULIC DRAIN VALVE AS REQUIRED IRW…
- 11 Mar 2026
Stay, damaged
DURING HEAVY MAINTENANCE: LANDING GEAR - LH MAIN GEAR - INTRODUCE DOUBLE LOCKING SIDESTAY CARDAN JOINTS; REF: /1/ AIRBUS SERVICE BULLETIN A320-32-1429…
- 11 Mar 2026
Stay, damaged
DURING HEAVY MAINTENANCE: LANDING GEAR - RH MAIN GEAR - INTRODUCE DOUBLE LOCKING SIDESTAY CARDAN JOINTS; REF: /1/ AIRBUS SERVICE BULLETIN A320-32-1429…
- 11 Mar 2026
Slide, faulted
DURING HEAVY MAINTENANCE: RH OVERWING ESCAPE SLIDE BALL LOCK ARE NOT FLUSH DUE TO PAINT COVERING THEM; REF AEROMAN W/O 2026- 76/1 NR# 129772, REMOVED AND…
- 11 Mar 2026
Hinge Fitting, damaged
DURING HEAVY MAINTENANCE: CRACK INDICATION ON KEEL BEAM MLG DOOR HINGE FITTING RH SIDE, FWD LUG WEB LOWER OUTBOARD RADIUS OF MACHINED POCKET, CRACK LENGTH IS…
- 11 Mar 2026
Hinge Fitting, damaged
DURING HEAVY MAINTENANCE: CRACK INDICATION ON KEEL BEAM MLG DOOR HINGE FITTING LH SIDE, AFT LUG WEB LOWER OUTBOARD RADIUS OF MACHINED POCKET, CRACK LENGTH IS…
- 11 Mar 2026
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (843) FRAME SEGMENT (1), (2EA) CRACK LENGTH: 0.437 INCH; ACCOMPLISHED PERMANENT REPAIR…
- 11 Mar 2026
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (833) FRAME SEGMENT (1), (1 EA) CRACK LENGTH: 0.437 INCH; REF AEROMAN WO 2026-76/1 N/R…
- 11 Mar 2026
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (844) FRAME SEGMENT (1), (1 EA) CRACK LENGTH: 0.435 INCH; ACCOMPLISHED PERMANENT…
- 9 Jan 2026
Unknown, odor
FLT 591 BOS- TPA. UPON ARRIVAL AT THE GATE, ENG'S SHUTDOWN, APU BLEED WAS TURNED ON 2 MIN AFTER SHUTDOWN VERY STRONG DIRTY SOCK ODOR. IN COCKPIT AND FWD…
- 14 Jan 2025
Lamp, inoperative
FLT#914, FLL-HPN.'LH OVERWING EMERGENCY EXIT LIGHT PARTIALLY LIT ( EXIT MARKING SIGNS 1) WALL MOUNTED EXIT (MARKING) SIGNS ); RELAMPED AS REQ IAW AMM 33-51-13…
- 5 Aug 2024
Slide Raft, unwanted deploy
FLT#1262, PBI-JFK. 'RT SIDE FWD EMER SLIDE DEPLOYED BY ACCIDENT BY MX; REMOVED AND REPLACED R1 DOOR ESCAPE SLIDE RAFT ASSY. IAW AMM 25-62-44.'
- 16 Jun 2024
Thermostat, failed
FLT#1233, MCO-SJU. (AIRCRAFT PERFORMED AN AIR TURN BACK TO MCO) 'ENG# 1 BLEED FAULT ON CLIMB OUT; REMOVED AND REPLACED THERMOSTAT FAN AIR VALVE CTL PER TSM…
- 14 Jun 2024
Controller, unknown
FLT#2403, JFK-MCO. (AIRTURN BACK TO JFK) 'AFTER T/O ENG 1 BLEED FAULT; REMOVED AND REPLACED BMC 1 IAW AMM 36-11-34. OPS CHECK GOOD.'
- 14 Jun 2024
Valve, failed
FLT#383, JFK-MCO. 'ENGINE #1 BLEED FAULT ON TAKE OFF; REMOVED AND REPLACED FAN AIR VALVE IAW AMM 36-11-54. OPS CHECK GOOD.'
- 5 Apr 2024
Hose, failed
FLT#1453, FLL-SJU. (AIRCRAFT DECLARED AN EMERGENCY INTO SJU)' HYD G RSVR LO LVL MSG ON ECAM FOLLOWED BY COMPLETE HYD SYSTEM GREEN FLUID LOSS; FOUND FLEXIBLE…
- 12 Oct 2023
Unknown, unknown
FLT#959, BDL-FLL. (AIRCRAFT DIVERTED TO BOS) 'WX RADAR INOP; REMOVED AND REPLACED WX RADAR TRANSCEIVER IAW AMM 34-41-33. OPS CHECK GOOD. OK FOR SVC.'
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION LOWER SURFACE TOP SKIN OVERHANG BTW RIB 15 AND RIB 16 ON RH WING; PERFORMED PERMANENT REPAIR IAW EA 57-0054-23. WORK…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION LOWER SURFACE TOP SKIN OVERHANG BTW RIB 15 AND RIB 16 ON RH WING; PERFORMED PERMANENT REPAIR IAW EA 57-0054-23. WORK…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16RH SIDE INTERCOSTAL FITTING ON HOLE 3 AT DOOR STOP POSITION 7 CRACK DIRECTION IS 9 O'CLOCK AT FWD GALLEY…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION CLIP AT FR34 BTW STR43R AND STR44 IN FWD CARGO COMPARTMENT REF. MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD:…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION STRINGER 42R AT FR32 PLUS 1 INCH IN FWD CARGO COMPARTMENT REF. MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD:…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION CLIP AT FR33 STR43L AND STR 43R IN FWD CARGO COMPARTMENT REF MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD:…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION CLIP AT FR33 BTW STR42R AND STR43R IN FWD CARGO COMPARTMENT REF MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD:…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION CLIP AT FR32 BTW STR43R AND STR44 IN FWD CARGO COMPARTMENT REF MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD:…
- 13 Mar 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION CLIP AT FR31 BTW STR43L AND STR44 IN FWD CARGO COMPARTMENT REF. MPD TASK 532180-01; (RESOLVED ON W/O: 1212223 TASKCARD:…
- 2 Jan 2023
Lamp, inoperative
FLT 1530, RSW-JFK. RT EXIT ROW LIGHTS INOPERATIVE. REPLACED THE LAMPS AS REQUIRED.
- 3 Dec 2022
Transducer, failed
FLT#737, BDL-MCO. (AIRCRAFT DECLARED AN EMERGENCY) 'UPON GEAR EXTENSION, RECEIVED THE FOLLOWING ECAMS. BRAKES AUTO BRK FAULT AND BRAKES RELEASED; INTERROGATED…
- 31 Aug 2022
None, none
FLT#120, MCO-ALB. 'ODOR PRESENTED AT 10'K ON DESCENT. IT PERSISTED THROUGHOUT THE LANDING AND WAS REPORTED TO GET WORSE ONCE PARKED AT GATE. PRESENT MOSTLY IN…
- 25 May 2022
Ecs, odor
FLT#2053, FLL-SJU. 'SEVERE FUME EVENT BELOW 10000 UNTIL PARKED AT GATE. SMELLED LIKE MAGIC MARKER. USED 02 UNT LANDING STRONGEST SMELL IN FLIGHT DECK; REF…
- 23 May 2022
Filter, odor
FLT#2085, BDL-MIA. 'ON DESCENT AT 10K ODOR DETECTED IN CABIN AND FLIGHT DECK CLEARED AS DESENDED ( PACKS ); REFERENCE LOG PAGE 3415373, ITEM #1 (REFERENCE LOG…
- 21 Apr 2022
None, none
FLT#1705, EWR-FLL. 'ON DESCENT FROM 8000" TO 3000" WHILE PASSING THROUGH CLOUDS, NOTICEABLE FUME SMELL OF DIRTY SOCKS. DISSIPATED BEFORE LANDING; COMPLIED…
- 21 Apr 2022
Apu, odor
FLT#1705, EWR-FLL. ' ON DESCENT FROM 8000" TO 3000" WHILE PASSING THROUGH CLOUDS, NOTICEABLE FUME SMELL OF DIRTY SOCKS. DISSIPATED BEFORE LANDING; COMPLIED…
- 17 Apr 2022
None, none
FLT#2895, BOS-PUJ. 'APU INOP. FOUND OIL IN THE INLET. REF ITEM 1 OF THIS LOG PAGE. ( APU SYSTEM ); PERFORMED PACK BURN, CHANGED FILTERS, AND CLEARED APU AREA…
- 8 Apr 2021
Ecs, odor
FLT 1230, CUN-EWR. ON DESCENT THROUGH 13000' FAS ADVISED THERE WAS A ""DIRTY SOCK"" SMELL BETWEEN ROWS 2 AND 11. I ISOLATED THE #1PACK AND SMELL DISIPATED.…
- 16 Jan 2021
Ecs, contaminated
FLT 1534, TPA-BDL. DIVERTED TO MCO AFTER TAKEOFF GOT DIRTY SOCK SMELL, HEAVY IN REAR OF CABIN AND COCKPIT. INCREASED DRASTICALLY IN DESCENT. ECS CONTAMINATED…
- 16 Jan 2021
Filter, contaminated
FLT 1534, TPA-BDL. DIVERTED TO MCO. AFTER TAKEOFF GOT DIRTY SOCK SMELL, HEAVY IN REAR OF CABIN AND COCKPIT. INCREASED DRASTICALLY IN DESCENT. ECS CONTAMINATED…
- 13 Nov 2020
Battery, no test
FLT 1074, BNA-JFK, REF TASKCARD A320-33-51-00-710-003. BATTERY 13WL FAILED CAPACITY TEST. R & R BATTERY 13WL EPSU, IAW MM 33-51-38. OPERATIONS CHECK GOOD.
- 13 Nov 2020
Battery, no test
FLT 1074, BNA-JFK, REF TASKCARD A320-33-51-00-710-003. BATTERY 10WL FAILED CAPACITY TEST. R & R BATTERY 10WL EPSU, IAW MM 33-51-38. OPERATIONS CHECK GOOD.
- 13 Nov 2020
Battery, no test
FLT 1074, BNA-JFK., REF TASKCARD A320-33-51-00-710-003. BATTERY 12WL FAILED CAPACITY TEST. R & R BATTERY 12WL EPSU, IAW MM 33-51-38. OPERATIONS CHECK GOOD.
- 13 Nov 2020
Battery, no test
FLT 1074, BNA-JFK, REF TASKCARD A320-33-51-00-710-003. BATTERY 11WL FAILED CAPACITY TEST. R & R BATTERY 11WL EPSU, IAW MM 33-51-38. OPERATIONS CHECK GOOD.
- 15 Sep 2020
Skin, dented
DURING HEAVY MAINTENANCE: DENT EXTERNAL SKIN BETWEEN FR 25-FR 26 AND BETWEEN STR 44-43, REF ARM W/O 2020-278/1 N/R 2020-270537. PERFORMED PERMANENT REPAIR…
- 7 May 2020
Battery, faulted
FT # 284, MCO-JFK. EPSU LH BAT FAULT; R & R EPSU BAT IAW AMM 33-51-00
- 11 Mar 2019
Battery, discharged
SUPPLEMENTAL INFORMATION (CHANGING SEQUENCE NUMBER FROM 0121 TO 0122): FLT 1391, BOS-TPA. AFT EMER LIGHT WON'T TEST; R & R AFT EMER LIGHT BATTERY (13WL) OPS…
- 28 Sep 2018
Battery, failed
FLT 1038, AUS-BOS. DURING EMERGENCY LIGHTS BATTERY CAPACITY TEST. EPSU UNIT LEFT FAILED. REMOVED AND REPLACED EPSU (11WL) LEFT BATTERY. OPS CHECK GOOD. REF…
- 27 Aug 2018
Battery, failed
FT# 1048, SDQ-FLL. FWD (LI, R1) EMERGENCY EXIT SIGNS NOT WORKING: R & R FWD L/H EPSU BATTERY IAW AMM 33-51-18 OPS CK GOOD AT THIS TIME. OK TO CONT SVC.
- 6 Apr 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION FOUND AT PREVIOUS BLEND AREA RT TOP SKIN NR 2 TE OVERHANG LWR SURFACE RIB 14 I/B NR 3 SPOILER ACTUATOR FTG; COMPLIED WITH…
- 6 Apr 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION FOUND AT PREVIOUS BLEND AREA RT TOP WING SKIN NR 2 TE OVERHANG LWR SURFACE I/B NR 2 SPOILER ACT HINGE FTG; COMPLIED WITH…
- 6 Apr 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION FOUND AT PREVIOUS BLEND AREA RT TOP WING SKIN NR 2 TE OVERHANG LWR SURF RIB 13 PLUS 13"; COMPLIED WITH JB EC A18-182-01.
- 6 Apr 2018
Box Beam, cracked
DURING C6 CHECK (GSO) DATED 2/2018, AFTER ACCOMPLISHMENT OF ROTOTEST INSPECTION REQUIRED PER REF /4/ SB– REPORTED THAT CRACKS WERE FOUND ON THE UPPER FLANGE…
- 11 Mar 2017
Probe, failed
DURING LANDING, ECAM FOR NR 2 ENGINE SENSOR FAULT. REMOVED AND REPLACED THE NR 2 ENGINE EGT PROBES IAW AMM 77-21-15.
- 11 Mar 2017
Thermocouple, failed
DURING LANDING, ECAM NR 2 ENG SENSOR FAULT. REMOVED AND REPLACED NR 2 ENG UPPER LEFT AND UPPER RIGHT EGT PROBES IAW AMM 77-21-15.
- 4 Nov 2016
Door Sill, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE, ON L2 DOOR SILL BEAM AT FRAMES 67 +18 - 68, STRINGER 23L. FABRICATED, LOCATED,…
- 4 Nov 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN RIGHT SIDE OF FLOORBEAM -Y1292 AT FRAME 67 +18, STR 23R; REMOVED AND REPLACED FLOORBEAM.
- 4 Nov 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE RIGHT SIDE OF FLOORBEAM -Y1292 AT FR 66 STR 23R. REMOVED AND REPLACED THE FLOORBEAM IAW SRM…
- 4 Nov 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON INSIDE CABIN LEFT SIDE OF FLOOR SUPPORT Y765 AT FRAMES 68-69. REMOVED AND REPLACED FLOOR SUPPORT IAW…
- 4 Nov 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT -Y1292 AT FRAME 68. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 53-72-11.
- 8 Aug 2016
Torque Link, failed
STRONG NOSE WHEEL VIBRATION AFTER ROTATION. DIVERTED AND PERFORMED INSPECTIONS. R & R UPPER TORQUE LINK ASSEMBLY.
- 6 Mar 2016
Generator, failed
AFT LAV ELECTRICAL PUMP MAKING LOAD NOISE DURING FLUSH OPERATION, F/A AFT REPORT BURNING ODOR A/C RIGHTLAVATORY SYSTEMS- VACUUM GENERATOR; R & R VACUUM…
- 16 Feb 2016
Battery, no test
EMERGENCY LIGHT FAILS TEST. R & R BATTERY PACK AT FWD EPSU. 10WL OPS CHECK GOOD.
- 8 Dec 2011
Unknown, malfunctioned
FLT 470 RSW-BOS, AIRCRAFT DIVERTED TO CLT DUE TO FUEL CTR TK PUMP 2 LO PR ON ECAM WHILE PASSING THRU 10000 FT. 100 LBS IN CTR TANK FUEL WOULD NOT FEED FROM TK…
- 30 Aug 2011
Switch, faulty
FLT 61 JFK-FLL AIR RETURN TO JFK, DUE TO "B" HYD SYS LOW PRESSURE. ACCOMPLISHED OPERATION & INSPECTION OF BLUE HYD PUMP & SYS OPS TEST OF PHASE UNBALANCE…
- 23 Jul 2011
Csd, failed
FLT 528 MCO-EWR DURING MAINTENANCE EMERGENCY GENERATION SYSTEM TEST FAILED. REPLACED CSMG 8XE PER AMM 24-24-51 TEST IS GOOD.
- 27 Aug 2010
O-Ring, worn
FLT 144 PBI-JFK, CREW DECLARED AN EMERGENCY LANDING INTO JFK DUE TO HYD YELLOW LOW LEVEL. FOUND HYDRAULIC LEAK AT YELLOW SYSTEM HP MANIFOLD. REPLACED O-RING…
- 21 May 2009
Eec, failed
FLT 153, JFK-MCO, DURING DESCENT EXPERIENCED A FADEC ON ENG NR 1. ENGINE NR 1 WAS INCREASING TO CLIMB THRUST, SAW "THRUST LOCKED" ON ECAM AND IMMEDIATELY…
- 17 Dec 2008
Drain Line, leaking
FLT NR 300, LGB-IAD, GREEN HYD SYS FAIL IN FLIGHT. FOUND CASE DRAIN LINE NR 1 ENG PYLON LEAKING. REPLACED CASE DRAIN LINE, OPS AND LEAK CHECK GOOD. REPLACED…
- 7 Jul 2008
Computer, faulted
AIR RETURN TO DEPARTURE AIRPORT, L AIL FAULT, RAIL, FAULT RT AFTER TAKEOFF, NO AUTO PILOT ALT LAW, NO OTHER INDICATIONS, REMOVED AND REPLACED NR 1 ELAC IAW MM…
- 19 Jun 2008
Coffeemaker, odor
IN CRUISE, HAD ELECTRICAL FUMES IN FAT GALLEY APPROX 5 MIN, IT DISSIPATED C/W TSM 23-39-00-810-801. NO FAULTS FOUND AND NO DAMAGE NOTED DUE TO LTV SYS, OPS…