N646AW
1992 Airbus Industrie A320-231 FAA →
reservations
earlier registrations
1 past record
- 1992
service difficulty reports
62 reports
- 17 Sep 2011
Panel, cracked
PAX DOOR FWD & AFT SIDE PANELS CRACKED AT STEPS 2 & 3. REPAIRED PAX DOOR FWD & AFT SIDE PANELS IAW REO 601R-52-11-702, REV C.
- 3 Mar 2006
Battery, inoperative
PHX - EEL - DURING OVERNIGHT MAINTENANCE DISCOVERED THE LEFT FORWARD CABIN EPSU BATTERY PACK HAD -LOW CHARGE-. MAINTENANCE REMOVED AND REPLACED THE LEFT…
- 12 Aug 2005
Blades, failed
DURING CLIMBOUT, 500 AGL, LOUD BANG ACCOMPANIED WITH ACFT YAWING LT 5-10 FT. ENG RECOVERED IMMEDIATELY. ACFT CONTINUED & LANDED WITHOUT FURTHER EVENT. NO…
- 24 Jun 2005
Battery Pack, discharged
DURING 8-DAY CHECK, FOUND BOTH LT AND RT OVERWING SEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED LT (11WL) AND RT (12WL)…
- 22 May 2005
Epsu, faulty
PHX - EEL - DURING 8-DAY CHECK, A LT EMERGENCY POWER SUPPLY UNIT AND BATTERY PACK FAILED TEST. MAINTENANCE REMOVED AND REPLACED THE LT EMERGENCY POWER SUPPLY…
- 14 May 2005
Flashlight, inoperative
LAS - EMERGENCY EQUIPMENT DURING 8-DAY CHECK, THE AFT FLIGHT ATTENDANT FOLD OUT JUMP SEAT EMERGENCY FLASHLIGHT WOULD NOT TEST. MAINTENANCE REMOVED AND…
- 30 Nov 2004
Slide, delaminated
PHX - EES - DURING 4-DAY CHECK THE LOWER AFT CORNER OF THE RT OVERWING SLIDE WAS FOUND DELAMINATED. MAINTENANCE REMOVED AND REPLACED THE RT OVERWING SLIDE…
- 21 May 2004
Deu, faulty
PHX - EEL DURING 4-DAY CHECK: FUNCTIONAL TEST OF EMERGENCY LIGHT SYSTEM FAILED AT CIDS PANEL. MAINTENANCE REMOVED AND REPLACED DECODER ENCODER UNIT (DEU) B…
- 1 Apr 2004
Flashlight, inoperative
PHX - EMERGENCY EQUIPMENT - FLIGHT CREW REPORTED THE AFT OUTBOARD EMERGENCY FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFT OUTBOARD…
- 23 Mar 2004
Bearing, failed
PHX - EMERGENCY LANDING - FLT 0272 - ON SHORT AND FINAL INTO PHX EN ROUTE FROM SNA ENCOUNTERED SMOKE AND A STRONG ELECTRICAL BURNING ODOR IN CABIN, DONNED…
- 12 Sep 2003
Diaphragm, leaking
DURING INSPECTION FOUND THE L-2 DOOR EMERGENCY OPERATION CYLINDER PRESSURE GAUGE READING ZERO. MAINTENANCE REMOVED AND REPLACED THE DIAPHRAGM IN PERCUSSION…
- 1 Sep 2003
Connector, damaged
EN ROUTE, AFTER TAKEOFF BLEEDS OFF RECEIVED ECAM MESSAGE NR 2 ENG BLEED ABNORMAL PRESS. TURNED OFF APU BLEED SWITCH NR 2 ENG BLEED ONLY AT 24 PSI, DIVERTED…
- 17 Aug 2003
Lanyard, torn
ON DECENT, EN ROUTE FROM PHX THE FLIGHT ATTENDANT REPORTED A LOUD SQUEAL COMING FROM THE L-2 DOOR. MAINTENANCE FOUND THE L-2 DOOR SLIDE LOWER LANYARD TORN AND…
- 21 May 2003
Terminal, broken
DURING C-01 CHECK THE EMERGENCY EXIT LIGHT BETWEEN THE L/H OVER-WING HATCHES WOULD NOT ILLUMINATE. MAINTENANCE REMOVED AND REPLACED A BROKEN EMERGENCY EXIT…
- 19 May 2003
Floor Panel, delaminated
MCN - MAJOR REPAIR - DURING C-01 CHECK CABIN FLOOR PANEL 242GF WAS FOUND DELAMINATED. MAINTENANCE REMOVED CABIN FLOOR PANEL 242GF; FABRICATED A NEW…
- 19 May 2003
Floor Panel, delaminated
MCN - MAJOR REPAIR - DURING C-01 CHECK CENTER WING FLOOR PANEL 242FF WAS FOUND DELAMINATED. MAINTENANCE REMOVED DAMAGED FLOOR PANEL 242FF; FABRICATED A NEW…
- 19 May 2003
Floor Panel, delaminated
MCN - MAJOR REPAIR - DURING C-01 CHECK CABIN FLOOR PANEL 241FF WAS FOUND DELAMINATED. MAINTENANCE REMOVED DAMAGED FLOOR PANEL 241FF; FABRICATED A NEW…
- 19 May 2003
Floor Panel, delaminated
DURING C-01 CHECK CENTER WING FLOOR PANEL 241EF WAS FOUND DELAMINATED. MAINTENANCE REMOVED DAMAGED FLOOR PANEL 241EF; FABRICATED A NEW REPLACEMENT PANEL PER…
- 15 May 2003
Fitting, broken
MCN - EES - DURING C-01 CHECK THE LT OVERWING HATCH SLIDE BOTTLE CABLE FITTING WAS FOUND BROKEN. MAINTENANCE REMOVED AND REPLACED THE LT OVERWING HATCH SLIDE…
- 15 May 2003
Terminal, broken
DURING C-01 CHECK THE L-1 DOOR CLASS DIVIDER EMERGENCY EXIT LIGHT CONNECTOR WAS FOUND DAMAGED. MAINTENANCE REMOVED AND REPLACED THE L-1 DOOR CLASS DIVIDER…
- 30 Jan 2003
Pipe, leaking
LAS - EMERGENCY LANDING - EN ROUTE FROM DFW TO LAS ON DECENT THE GREEN HYDRAULIC SYSTEM FAILED. MAINTENANCE FOUND CHAFED HYDRAULIC RETURN LINE IN LT ENGINE…
- 26 Aug 2002
Cable, broken
PHX - EEL - DURING INSPECTION THE EMERGENCY ESCAPE PATH LIGHT AT SEAT ROW 26 L/H WAS FOUND INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE AND REPLACED…
- 29 Jul 2002
Scavenge Pump, leaking
PHX - FLT 0536 - WHILE AIRCRAFT WAS TAXIING TO GATE, THE AIRCRAFT TAXIING BEHIND REPORTED SEEING A TAILPIPE FIRE AT NR 1 ENGINE TAILPIPE. MAINTENANCE…
- 9 Jul 2002
Engine, fire
FLT 0279 - AFTER LANDING AT IAH INBOUND FROM PHX, AFTER ENGINE SHUTDOWN AT GATE, GROUND CREW OBSERVED FIRE IN THE TAILPIPE OF THE NR 1 ENGINE. FLIGHT CREW…
- 24 Feb 2002
Power Supply, discharged
YWG - EEL -C- DURING C-08 CHECK EMERGENCY ESCAPE PATH LIGHTING AT ROWS 13, 17, 19, 24 WERE FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER…
- 12 Feb 2002
Floor Support, corroded
YWG - MAJOR REPAIR - C - DURING C-8 CHECK CORROSION WAS FOUND ON FLOOR SUPPORT BEAM Y1292 RT BETWEEN FR 66 AND FR 67. MAINTENANCE REMOVED CORROSION AND FOUND…
- 10 Feb 2002
Floor Support, corroded
YWG - MAJOR REPAIR - C - DURING C-8 CHECK CORROSION WAS FOUND ON FWD & AFT FLOOR SUPPORT BEAM Y254 LT BETWEEN FR 15 AND FR 21. MAINTENANCE REMOVED CORROSION…
- 10 Feb 2002
Floor Support, corroded
YWG - MAJOR REPAIR - C - DURING C-8 CHECK CORROSION WAS FOUND ON FWD & AFT FLOOR SUPPORT BEAM Y1292 RT BETWEEN FR 15 AND FR 19. MAINTENANCE REMOVED FLOOR…
- 10 Feb 2002
Seat Track, corroded
YWG - MAJOR REPAIR - "C" - DURING C-8 CHECK CORROSION WAS FOUND ON FWD & AFT FLOOR SEAT TRACK Y765 R/H FR 16. MAINTENANCE REMOVED FLOOR SEAT TRACK Y765 R/H,…
- 10 Feb 2002
Seat Track, corroded
YWG - MAJOR REPAIR - "C" - DURING C-8 CHECK CORROSION WAS FOUND ON FWD & AFT FLOOR SUPPORT SEAT TRACK Y254 L/H FR 20. MAINTENANCE REMOVED CORROSION FROM FLOOR…
- 8 Feb 2002
Frame, damaged
YWG - MAJOR REPAIR - C - DURING C-08 CHECK TOOLING HOLES AT FR 38-40 LT TO RT WERE FOUND TO BE OVERSIZED. COLD EXPANDED THE HOLES PER SRM 51-48-00,…
- 2 Feb 2002
Frame, cracked
TEST
- 2 Feb 2002
Frame, cracked
TEST
- 2 Feb 2002
Frame, cracked
TEST
- 2 Feb 2002
Frame, cracked
TEST
- 25 Jan 2002
Floor Support, corroded
YWG - MAJOR REPAIR - C - DURING C-08 CHECK CORROSION WAS FOUND ON FLOOR SUPPORT Y1292 AT FR 66 RT. MAINTENANCE REMOVED CORRODED FLOOR SUPPORT, FABRICATED NEW…
- 25 Jan 2002
Floor Support, corroded
YWG - MAJOR REPAIR - "C" - DURING C-08 CHECK CORROSION WAS FOUND AROUND SCREW HOLES ON FLOOR SUPPORT AT Y1162R, BETWEEN FR 68 & 69. MAINTENANCE REMOVED…
- 22 Jan 2002
Floor Support, corroded
YWG - MAJOR REPAIR - "C" - DURING C-08 CHECK CORROSION WAS FOUND ON FORWARD AND AFT FLOOR SUPPORT IN FORWARD CABIN AT Y254, FR 15-19. MAINTENANCE CLEANED…
- 5 Jan 2002
Battery, discharged
PHX - EEL - C - DURING INSPECTION ALL EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. NOTE: AIRCRAFT HAS BEEN PARKED SINCE 30 NOVEMBER, 2001. MAINTENANCE…
- 19 Jun 2001
Warning System, false activation
PHX- AIR TURNBACK - FLT 752- AFTER TAKEOFF, ECAM MESSAGE AFT CARGO DOOR APPEARED AND THE AIRCRAFT WAS RETURNED TO PHX. IN PHX MAINTENANCE INSPECTED THE AFT…
- 19 Feb 2001
Fmc, failed
PHX - DIVERTED FLIGHT - 2/14/01 - AFTER TAKEOFF FROM LAS TO BOS THE MCDU FROZE IN THE FLIGHT PLAN MODE; RNAV UNAVAILABLE; THE FLIGHT WAS DIVERTED TO PHX. IN…
- 26 Jan 2001
Actuator, leaking
PHX- EMERGENCY LANDING, FLIGHT CREW HAD ECAM MESSAGE FOR YELLOW HYDRAULIC SYSTEM LOW LEVEL. AN UNEVENTFUL LANDING WAS MADE. IN PHX MAINTENANCE FOUND THE RT NR…
- 6 Dec 2000
Servo, malfunctioned
PHX - AIR TURNBACK - ON CLIMB OUT AND CRUISE AIRCRAFT HAD LEFT WING DOWN 5 TO 7 DEGREES AND RUDDER TRIM 2.8 DEGREES RT. MOST NOTICABLE AT 250 KTS. AND ABOVE;…
- 20 Feb 2000
Fire Detector, malfuntioned
NR 2 ENGINE FIRE LIGHT AND MASTER FIRE LIGHT INDICATED FIRE, NO ECAM, NO MASTER WARNING. ENGINE 2 SHUTDOWN IN-FLIGHT AND BOTH FIRE BOTTLES FIRED. REMOVED AND…
- 11 Oct 1999
Wire, broken
SEAT 9 RT EMERGENCY EXIT LIGHT INOP. REPAIRED WIRING, OPS CK NML.
- 6 Oct 1999
Actuator, failed
EMERGENCY DECLARED (NOT BY PILOT) ENG NR 1 COMPRESSOR VANE FAULT ON DESCENT, NO OTHER ABNORMAL ENG INDICATIONS OR FAILURES. FIRST TIME FAULT FADEC CONFIRMS…
- 6 Oct 1999
Oil Cooler, leaking
DURING DESCENT WITH POWER AT IDLE, NOXIOUS ODORS EMANATED FROM THE LT PACK, CAPABLE OF EYE AND THROAT IRRITATION. ISOLATED TO LEAKING OIL COOLER. REMOVED AND…
- 6 Sep 1999
B Nut, loose
AMBER ECAM MESSAGE, CLASS NR 1. YELLOW HYDRAULIC RESERVOIR LOW QUANTITY. FOUND 'B' NUT LOOSE ON YELLOW HYDRAULIC ACCUMULATOR. TIGHTENED NUT. SERVICED SYSTEM…
- 14 Jul 1999
Pack, malfunctioned
NOTICEABLE OFFENSIVE ODOR FROM AIR CONDITIONING SYSTEM DURING CLIMB AND DESCENT. LT PACK PRODUCING SMELL. PLACED ON MEL 21-52-01.
- 22 Jun 1999
Coalescer, dirty
ACRID SMELL AFTER TAKEOFF AND INCREASINGLY WORSE THROUGHOUT THE FLIGHT. SMELL INCREASED FROM SMELL ON GROUND. ACCOMPLISHED TSM 21-00-00-801-810 TO CHECK FOR…
- 21 Jun 1999
Air Dist, odor
STRONG OILY SMELL AFTER TAKEOFF, BELIEVE TO BE PACK SMELL. STILL COULD SMELL AT CRUISE. INSPECTED APU INLET FOR SIGNS OF OIL, NONE FOUND. RAN ENGINES…
- 4 Jun 1999
Inlet, dirty
CONDITIONED AIR HAS PUNGENT ODOR (SMELLS LIKE DIRTY SOCKS), NUMEROUS PASSENGER COMPLAINTS. PLACED ON MEL 36-12-01, CONTROL NUMBER 105131, APU BLEED AIR SYSTEM…
- 22 Mar 1998
Floor Track, corroded
DURING SCHEDULED C-5 INSPECTION, FOUND NR 4 TRACK CORRODED STATION 800. TRACK REPLACED AS PER SRM 53-11-15, PAGE 217 AND 218.
- 11 Jan 1998
Battery Pack, discharged
LT MID CABIN EMERGENCY LIGHT BATTERY PACK WILL NOT CHARGE. REMOVED AND REPLACED BATTERY PACK, OPS GOOD.
- 21 Dec 1997
Lens, missing
ROW 13L EMERGENCY LIGHT LENS MISSING. REPLACED LENS.
- 19 Dec 1997
Lens, missing
LROW 19 EMERGENCY LIGHT LENS MISSING. REPLACED LENS.
- 5 Nov 1997
Battery Packs, discharged
DURING ROUTINE MAINTENANCE CHECK, FOUND NUMEROUS EMERGENCY LIGHTS INOP IN CABIN. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACKS AT RT AND LT SIDE MID…
- 22 Jul 1997
Battery Pack, discharged
DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOP IN MID-CABIN. REMOVED AND REPLACED BATTERY PACK AT EXIT ROW ON RIGHT SIDE. OPS CHECK NORMAL.
- 26 Jun 1997
Battery Pack, discharged
DURING ROUTINE MAINTENANCE CHECK, FOUND RIGHT OVERWING EXIT EMERGENCY BATTERY PACK WOULD NOT HOLD CHARGE. REMOVED AND REPLACED BATTERY PACK, OPS CHECK GOOD.
- 17 May 1997
Sensor, broken
DURING GEAR RETRACTION NR 2 LGCIU WENT INOP, HAD TO RECYCLE LANDING GEAR. REPLACED 39GA PROX SENSOR, OPS CHECK GOOD.
- 3 May 1997
Battery Pack, discharged
DURING ROUTINE MAINTENANCE CHECK, FOUND LT CABIN EMERGENCY LIGHT BATTERY PACK DISCHARGED. REMOVED AND REPLACED BATTERY PACK, OPS CHECK GOOD.
- 11 Apr 1997
Oven, smoking
PIREP REPORT, NUMBER 1 OVEN IN FWD GALLEY PRODUCED SMOKE. INSPECTED AND FOUND NO DEFECTS.