- 1994
service difficulty reports
63 reports
- 14 Oct 2008
Cover, broken
EMERGENCY LIGHT COVER BROKEN BY PASSENGER.
- 12 Sep 2008
Sign, detached
F/A REPORTS SERVICE DOOR EMERGENCY EXIT SIGN NEEDS TO BE REATTACHED. FLT 4253 DEL 20 MINS. REATTACHED EMERGENCY EXIT SIGN LT COVER. LT OP CHECKS OK IAW JIC…
- 2 Aug 2008
Light, inoperative
A/S/D EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED A/S/D EMERGENCY FLOOD LIGHT IAW ATR 72 AMM 33-51-24. PERFORMED OPS CHECK OF THE EMERGENCY LIGHTING…
- 11 Dec 2007
Mount, damaged
RT ENG LT FWD LATERAL SHOCKMOUNT CRACKED. RT ENG LT FWD LATERAL SHOCKMOUNT AFT MOLDED CUSHION REPLACED IAW AMM 71-20-22 AND JIC 71-21-61 RAI 10 000.
- 11 Dec 2007
Bracket, cracked
PAX DOOR SURROUND 255DW, 255EW IN CRACKED. NLG FWD LT DOOR FWD STOP BRACKET REPLACED IAW SRM 51-25-01REPAIR DETERMINED NOT TO BE A MAJOR REPAIR IN ACCORDANCE…
- 10 Dec 2007
Doubler, corroded
DOUBLER CORRODED AT LWR FUSELAGE AREA (ANTENNA DOUBLER) FR 16-17 (SEE W/C 2000-18 FOR FABRICATION) SEE STICKER 200.
- 10 Dec 2007
Bracket, cracked
NLG FWD LT DOOR, FWD STOP BRACKET CRACKED.
- 10 Dec 2007
Floorbeam, corroded
FOUND FLOORBEAM 41 CORRODED.
- 10 Dec 2007
Floorbeam, corroded
FOUND FLOORBEAM 36 CORRODED.
- 10 Dec 2007
Intercostal, cracked
CRACK FOUND ON RT O/B INTERCOSTAL BTW FUSELAGE FAIRING FR 23D TO FUSELAGE.
- 10 Dec 2007
Angle, cracked
ANGLE CRACK ON LT O/B FUSELAGE FR 23D, BRACKET FIXED ON FUSELAGE SKIN.
- 10 Dec 2007
Bracket, cracked
LT I/B FLAP O/B FLAP ARM OMEGA BRACKET CRACKED.
- 9 Oct 2007
Door, binding
F/A REPORTS MAIN CABIN DOOR HARD TO OPEN.
- 2 Sep 2007
Wire, exposed
WIRING UNSHIELDED IN FLOOR EMERGENCY LIGHTING, SOME FLOOR LIGHTING INOP.
- 25 May 2007
Warning System, activated
DURING INITIAL CLIMBOUT NR 1 ENG LO OIL PRESS WARNING BOTH LOCAL ALERT & CCAS ACTIVATED. ALERT INTERMITTANT. ALERT ACTIVE FOR APROX 1-2 MIN INITIALLY & OFF…
- 21 May 2007
Oil System, low pressure
ENG NR 1 LOW OIL PRESSURE IN FLIGHT. COMPLIED WITH QRH RETURNED TO ATL. A/C RETURNED TO ATL AFTER T/O. EMERGENCY DECLARED.
- 1 Mar 2007
Landing Gear, malfunctioned
LANDING GEAR WILL NOT RETRACT AFTER TAKEOFF. FLT 4858 CX ON 3/2/07. A/C RETURNED TO AGS AFTER T/O. LANDING GEAR RETRACTION SYSTEM.
- 30 Sep 2006
Light, inoperative
ASD STEP LIGHT INOP.
- 7 Aug 2006
Light, inoperative
A/S/D LAMP LIGHT INOP.
- 8 Dec 2005
Floorbeam, corroded
DURING A C-CHECK IN YUL, THE FLOORBEAM, AT FS 38 WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REPAIRED THE FLOORBEAM, AT FS 38, IAW ASA EO 72-53-0205.…
- 18 Aug 2005
Light, inoperative
DURING HANGAR MAINTENANCE IN MCN, THE EMERGENCY LIGHT ON THE PASSENGER DOOR WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT…
- 14 Nov 2004
Cover, missing
DURING A GROUND INSPECTION, THE RT FWD FLOOR LEVEL EMERGENCY EXIT LIGHT COVER WAS FOUND MISSING. MAINTENANCE REPLACED THE RT FORWARD FLOOR LEVEL EMERGENCY…
- 7 Nov 2004
Battery Pack, discharged
DURING HANGAR MAINTENANCE, VARIOUS LIGHTS WERE FOUND INOPERATIVE ON THE EMERGENCY FLOOR LIGHT STRIP. MAINTENANCE REMOVED AND REPLACED THE NR 3 EMERGENCY…
- 29 Oct 2004
Power Supply, inoperative
DURING A GROUND INSPECTION, NUMEROUS EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY AT 73WL. OPERATIONAL…
- 6 Sep 2004
Lamp, burned out
FLT 4517 - DURING A GROUND INSPECTION IN MGM, THE EMERGENCY LIGHT ON THE PASSENGER DOOR WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE ON THE…
- 7 Jun 2004
Lamp, inoperative
DURING HANGAR MAINTENANCE IN MCN, THE LAST BULB IN THE AFT END OF THE EMERGENCY FLOOR LIGHT TRACK WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND…
- 31 May 2004
Lamp, burned out
DURING A GROUND INSPECTION IN VPS, THE EMERGENCY FLOOR LIGHT STRIP AT ROW 6 A/B WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY…
- 10 Mar 2004
Socket, damaged
DURING C-CHECK, THE EMERGENCY LIGHT ASSEMBLY ON THE PASSENGER DOOR WAS FOUND TO HAVE A DAMAGED AND CORRODED SOCKET. MAINTENANCE REMOVED AND REPLACED THE…
- 10 Mar 2004
Socket, damaged
DURING C-CHECK, THE EMERGENCY LIGHT ASSEMBLY ON THE PASSENGER DOOR WAS FOUND TO HAVE A DAMAGED AND CORRODED SOCKET. MAINTENANCE REMOVED AND REPLACED THE…
- 7 Mar 2004
Crease Beam, corroded
DURING C-CHECK INSPECTION, THE CREASE BEAM PLATE AFT OF FRAME 39 ON THE LT SIDE WAS FOUND BENT AND CORRODED. MAINTENANCE REMOVED AND REPLACED THE CORRODED AND…
- 7 Mar 2004
Floorbeam, corroded
DURING C-CHECK INSPECTION, THE FLOORBEAMS AT FRAMES 38 AND 39 WERE FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE CORRODED…
- 7 Mar 2004
Floorbeam, corroded
DURING C-CHECK, CORROSION BEYOND LIMITS WAS FOUND ON THE FLOORBEAM AT FRAME 36 NEAR THE SERVICE DOOR. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOORBEAM…
- 7 Mar 2004
Seat Track, corroded
DURING C-CHECK, THE LEFT SIDE SEAT TRACK AT FRAMES 36-39 AS WELL AS THE RT SIDE SEAT TRACK FROM FRAME 39-40 WERE FOUND CORRODED BEYOND LIMITS. MAINTENANCE…
- 7 Mar 2004
Bracket, corroded
DURING C-CHECK INSPECTION, CORROSION WAS FOUND BEYOND LIMITS ON BOTH THRESHOLD SUPPORT BRACKETS OF PASSENGER DOOR. MAINTENANCE REMOVED AND REPLACED THE…
- 7 Mar 2004
Floor Support, corroded
DURING C-CHECK, THE LT AND RT SIDE Z-FLOOR SUPPORT WAS FOUND CORRODED BEYOND LIMITS AFT OF FRAME 39. MAINTENANCE REMOVED AND REPLACED THE CORRODED Z-FLOOR…
- 7 Mar 2004
Floor Support, corroded
DURING C-CHECK, THE LT AND RT SIDE FLOOR SUPPORT WAS FOUND CORRODED BEYOND LIMITS AFT OF FRAME 39. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOOR…
- 7 Mar 2004
Support Bracket, corroded
DURING C-CHECK INSPECTION, CORROSION WAS FOUND BEYOND LIMITS ON BOTH THRESHOLD SUPPORT BRACKETS OF PASSENGER DOOR. MAINTENANCE REMOVED AND REPLACED THE…
- 7 Mar 2004
Seat Track, corroded
DURING C-CHECK, THE LT SIDE SEAT TRACK AT FRAMES 36-39 AS WELL AS THE RT SIDE SEAT TRACK FROM FRAME 39-40 WERE FOUND CORRODED BEYOND LIMITS. MAINTENANCE…
- 7 Mar 2004
Floorbeam, corroded
DURING C-CHECK, CORROSION BEYOND LIMITS WAS FOUND ON THE FLOORBEAM AT FRAME 36 NEAR THE SERVICE DOOR. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOORBEAM…
- 7 Mar 2004
Floorbeam, corroded
DURING C-CHECK INSPECTION, THE FLOORBEAMS AT FRAMES 38 AND 39 WERE FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE CORRODED…
- 7 Mar 2004
Crease Beam, corroded
DURING C-CHECK INSPECTION, THE CREASE BEAM PLATE AFT OF FRAME 39 ON THE LT SIDE WAS FOUND BENT AND CORRODED. MAINTENANCE REMOVED AND REPLACED THE CORRODED AND…
- 9 Feb 2004
Coffeemaker, burned
FLT 4313 - DURING APPROACH INTO ATL FROM MGM, THE FLIGHT ATTENDANT NOTICED AN ELECTRICAL ODOR IN THE CABIN. THE CREW REQUESTED EMERGENCY VEHICLES AS A…
- 2 Oct 2003
Lamp, burned out
DURING A GROUND INSEPCTION IN MGM, THE EXTERNAL EMERGENCY LIGHTS BY THE PASSENGER AND SERVICE DOORS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND…
- 24 Sep 2003
Lamp, inoperative
DURING AN A-CHECK IN MCN, THE PASSENGER DOOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE PASSENGER DOOR EMERGENCY LIGHT…
- 31 Aug 2003
Firewall, cracked
DURING HANGAR MAINTENANCE IN MCN, THE RT ENGINE NACELLE UPPER AFT FIREWALL WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE RIGHT ENGINE…
- 26 Aug 2003
Cap, missing
DURING CRUISE FROM ATL-MYR, AT APPROX 19,000 FT CREW RECEIVED A LT ENGINE OIL PRESSURE WARNING ON GAUGE AND CREW ALERT PANEL. OIL PRESSURE DROPPED SLOWLY TO…
- 5 Jun 2003
Terminal, loose
DURING AN A-CHECK IN MCN, AN EMERGENCY EXIT LIGHT WOULD NOT ILLUMINATE WHEN THE AFT BUTTON SWITCH WAS PUSHED. MAINTENANCE REPAIRED THE TERMINAL ON THE AFT…
- 27 May 2003
Acm, inoperative
DURING CRUISE, A BURNING ODOR OCCURRED IN THE CABIN AND THE RT PACK BECAME INOPERATIVE. THE AIRCRAFT LANDED SAFELY. MAINTENANCE REMOVED AND REPLACED THE ACM…
- 16 Apr 2003
Lamp, burned out
DURING FINAL APPROACH INTO VPS FROM ATL, THE FLIGHT ATTENDANT NOTICED SMOKE AND A SMOKE ODOR IN THE AFT CABIN AREA. THE AIRCRAFT LANDED SAFELY IN VPS.…
- 28 Dec 2002
Light, inoperative
DURING HANGAR INSPECTION IN MCN, THE AIR STAIR DOOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AIR STAIR DOOR EMERGENCY…
- 23 Jun 2002
Power Supply, discharged
DURING A HANGAR INSPECTION IN MCN, SEVERAL EMERGENCY LIGHTS THROUGH OUT THE CABIN WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT POWER…
- 9 May 2002
Floorbeam, corroded
DURING C-CHECK INSPECTION IN BNA, THE UPPER FLOORBEAM WAS FOUND CORRODED AT FRAME 36, FROM THE RIGHT TO THE LEFT SIDE OF THE FUSELAGE. MAINTENANCE REPAIRED…
- 9 May 2002
Stringer, corroded
DURING C-CHECK INSPECTION IN BNA, FRAMES 38, 39 AND 40 WERE ALL FOUND CORRODED THE ENTIRE LENGTH FROM STRINGER 16 LEFT TO 16 RIGHT. MAINTENANCE REPAIRED ALL…
- 9 May 2002
Skin, corroded
DURING C-CHECK INSPECTION IN BNA, THE RIGHT FUSELAGE SKIN WAS FOUND DENTED BEYOND LIMITS BETWEEN FRAMES 23A AND 23B AS WELL AS BETWEEN STRINGERS 13 RIGHT AND…
- 23 Mar 2002
Light, missing
FLT 4104 - DURING GROUND INSPECTION IN ATL, A MISSING LIGHT BULB WAS DISCOVERED IN THE PASSENGER DOOR EXIT SIGN. MAINTENANCE REPLACED THE MISSING EMERGENCY…
- 15 Jan 2002
Access Panel, broken
FLT 4318 - DURING CLIMB-OUT OF ATL, PASSING 500 FEET THE PILOT FELT A NOTICEABLE RHYTHMIC VIBRATION. AFTER PASSING 2000 FEET THE PILOT INCREASE THE AIRSPEED…
- 26 Mar 1998
Brake, fire
WHILE AT ATL, MAINTENANCE WAS TAXIING THE AIRCRAFT TO A HANGAR, THE RIGHT MAIN BRAKE OVERHEATED AND CAUGHT ON FIRE. THERE WERE NO WARNING INDICATIONS IN THE…
- 12 Dec 1997
Floor Beam, corroded
SAW - DURING C-CHECK, MAINTENANCE REPORTED CORROSION BEYOND LIMITS AROUND NUTPLATES ON RT SIDE OF FLOOR BEAM NR 36. SPLICED A 2-FOOT SECTION; MATERIAL MADE…
- 12 Dec 1997
Seat Track, corroded
SAW - DURING C-CHECK, MAINTENANCE REPORTED RIGHT FLIGHT ATTENDANT SEAT TRACK CORRODED. REPLACED RIGHT F/A SEAT TRACK IAW ASA E.O 72-53-0018. ACTT: 8,316.1…
- 12 Dec 1997
Seat Track, corroded
DURING C-CHECK, MAINTENANCE REPORTED LEFT FLIGHT ATTENDANT SEAT TRACK CORRODED. REPLACED LEFT F/A SEAT TRACK IAW ASA EO 72-53-0018. ACTT: 8,316.1 HOURS. AC…
- 12 Dec 1997
Support, corroded
DURING C-CHECK INSPECTION, MAINTENANCE REPORTED ACFT CARGO Z-MEMBER CORRODED BEYOND MANUFACTURER'S LIMITS. MAINTENANCE REPLACED Z-MEMBER IAW ATR 72 SRM…
- 12 Dec 1997
Angle, corroded
SAW - DURING C-CHECK, MAINTENANCE REPORTED CORROSION ON INTERCOSTAL BETWEEN FRAMES 38 AND 39 RT AT STR 17. INSTALLED NEW INTERCOSTAL IAW ATR 72 SRM. ACTT:…
- 10 Dec 1997
Doubler, corroded
SAW - DURING C-CHECK, MAINTENANCE REPORTED DOUBLER ON RT SIDE BEWEEN FLOOR BEAM AND FRAME CORRODED. REMOVED AND REPLACED DOUBLER IAW SRM 51-25-02. AIRCRAFT…