N638VA
2008 Airbus A320-214 standard FAA →
reservations
earlier registrations
1 past record
- 2008
service difficulty reports
34 reports
- 16 Jun 2022
Engine, failed
ENG 1 STALL AT FL 350 ENGINE RELIT AND STALLED AGAIN. GROUNDED - YES. PERFORMED FDIMU DATA DOWNLOAD OF PCMCIA CARD IAW 31-36-00-740. FOQ + DOWNLOAD…
- 23 Aug 2021
Skin, gouged
HISSING NOISE FROM DOOR 2 L LOWER PORTION IN FLIGHT. GROUNDED - YES. FOUND DAMAGE TO LOWER SECTION OF L2 DOOR. ACCOMPLISHED REPAIR TO LOWER SECTION OF THE L2…
- 7 Jul 2021
Hinge Fitting, broken
RH ELEVATOR, #3 HINGE FITTING, BROKEN GROUNDED - YES. REMOVED HINGE FITTING REF A320 SRM 51-42-11. REPAIRED FITTING REF A320 SRM 55-26-41-300-001. INSTALLED…
- 6 Jul 2021
Door Sill, corroded
R/H FWD SERVICE DOOR CUTOUT LOWER FWD CORNER HAS CORRODED AT FASTENER HOLE GROUNDED - YES. REMOVED 4 EACH WATER LINE CLAMPS, 4 EA HI-LOKS AND 1 EACH FLOOR…
- 6 Jul 2021
Door Sill, corroded
R/H FWD SERVICE DOOR CUT OUT LOWER AFT CORNER HAS CORRODED AT FASTENER HOLE DOT P772 GROUNDED - YES. ACCOMPLISHED REPAIR AS PER A320 SRM 53-11-14, R/H FWD…
- 6 Jul 2021
Door Sill, corroded
L/H FWD ENTRY DOOR CUT OUT AFT LOWER CORNER CORRODED AT FASTENER HOLE DOT:P776 GROUNDED - YES. ACCOMPLISHED REPAIR ON FWD ENTRY DOOR LOWER SILL IAW AIRBUS…
- 6 Jul 2021
Beam, corroded
FWD ENTRY DOOR CUTOUT LOWER FWD CORNER CORRODED AT FASTENER HOLE 4 EACH GROUNDED - YES. ACCOMPLISHED REPAIR ON FWD ENTRY DOOR LOWER SILL IAW AIRBUS A320 SRM…
- 6 Jul 2021
Beam, gouged
CABIN FLOOR STRUCTURE CENTER BEAM HAS GOUGE AT FASTNER HOLE APPROXIMATELY 5 INCHES FWD OF FR14 NEAR FLIGHT DECK DOOR AREA RH SIDE, STREAMER ATTACH AND MARKED…
- 6 Jul 2021
Seat Track, corroded
FRAME 21 R/H PANEL SUPPORT BEAM HAS CORR GOING TO FRAME 15C. DOT: P770 GROUNDED - YES. DAMAGE FOUND TO BE IN AN AREA WHERE REWORK IS NOT PERMITTED. OUT OF…
- 5 Jul 2021
Floor Support, corroded
FLOOR BEAM HAS AREA OF CORROSION ON TOP SURFACE, JUST AFT OF R2 DOOR AND TOWARDS CENTER OF A/C TWO FRAMES GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM P/N…
- 5 Jul 2021
Floorbeam, corroded
FLOOR BEAM HAS AREA OF CORROSION ON TOP SURFACE, JUST AFT OF R2 DOOR AND TOWARDS CENTER OF A/C ONE FRAME DOT:A441 GROUNDED - YES. REMOVED AND REPLACED SUPPORT…
- 5 Jul 2021
Floorbeam, corroded
FLOOR BEAM HAS AREA OF CORROSION ON TOP SURFACE, JUST AFT CORNER OF L2 DOOR DOT:A443 GROUNDED - YES. REMOVED CORROSION AND REPAIRED 2EA AREAS IAW A320 SRM…
- 5 Jul 2021
Floor Support, corroded
FLOOR BEAM HAS AREA OF CORROSION ON TOP SURFACE JUST AFT OF R2 DOOR DOT:A440 GROUNDED - YES. CORROSION FOUND TO BE OUT OF LIMITS. ORIGINAL THICKNESS IS .160,…
- 2 Jul 2021
Floorbeam, corroded
MAIN CABIN, AFT GALLEY UPPER FLOOR L/H SUPPORT FRAME CORRODED GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN AFT GALLEY UPPER FLOOR LH SUPPORT FRAME…
- 1 Jul 2021
Floor Support, corroded
MAIN CABIN AFT GALLEY AREA FLOOR BEAM CORRODED AT Y160.5 BETWEEN FR70-FR69 GROUNDED - YES. REMOVED AND REPLACED SUPPORT BEAM AT Y160.5 BETWEEN FR70-69 IAW…
- 1 Jul 2021
Floor Support, corroded
MAIN CABIN AFT GALLEY AREA FLOOR BEAM CORRODED AT Y512.5 BETWEEN FR70-FR69 GROUNDED - YES. REMOVED CORROSION AND CHECKED THE LIMITS. ORIGINAL THICKNESS IS…
- 30 Jun 2021
Floor Support, corroded
MAIN CABIN, AFT GALLEY AREA FLOOR BEAM AT -Y160.5 IS CORRODED. (P/N 5347209700200) DOT: A582 GROUNDED - YES. REMOVED CORROSION. ORIGINAL THICKNESS IS .160,…
- 30 Jun 2021
Shear Plate, corroded
MAIN CABIN, AFT GALLEY AREA UPPER FLOOR L/H SHEAR WEB CORRODED AT FR69-FR70 STR23L GROUNDED - YES. WEBB FOUND TO HAVE 100% MAT'L LOSS TOOL # E113387A. REMOVED…
- 30 Jun 2021
Shear Web, corroded
MAIN CABIN, AFT GALLEY AREA UPPER FLOOR R/H SHEAR WEB CORRODED AT FR69-FR70 STR23R. GROUNDED - YES. NO AVAILABLE LIMITS FOR THE SHEAR WEB. REMOVED AND…
- 28 Jun 2021
Floorboard, delaminated
AFT CARGO COMPARTMENT FLOORBOARD 152NF HAS 1 EA TEMPORARY REPAIR, REQUIRES PERMANENT REPAIR GROUNDED - YES. PERFORMED PERMANENT REPAIR ON AFT CARGO…
- 28 Jun 2021
Floor Panel, delaminated
AFT CARGO COMPARTMENT FLOORBOARD 152FF HAS 2EA TEMPORARY REPAIRS, REQUIRES PERMANENT REPAIRS GROUNDED - YES. PERFORMED PERMANENT REPAIR ON AFT CARGO…
- 28 Jun 2021
Floorboard, delaminated
AFT CARGO COMPARTMENT FLOORBOARD 152MF HAS 1 EA TEMPORARY REPAIR, REQUIRES PERMANENT REPAIR GROUNDED - YES. PERFORMED PERMANENT REPAIR ON AFT CARGO…
- 28 Jun 2021
Floor Panel, delaminated
AFT CARGO COMPARTMENT FLOORBOARD 152EF HAS 2EA TEMPORARY REPAIRS, REQUIRES PERMANENT REPAIRS GROUNDED - YES. PERFORMED PERMANENT REPAIR ON AFT CARGO…
- 23 Jun 2021
Floor Panel, delaminated
[PARTS RACK] FWD CARGO COM0PARTMENT FLOOR PANEL 131BF HAS 2 EA TEMPORARY REPAIRS, PERMANENT REPAIR REQUIRED. GROUNDED - YES. REPAIRED FWD CARGO COMPARTMENT…
- 23 Jun 2021
Floor Panel, delaminated
[PARTS RACK] FWD CARGO COMPARTMENT FLOOR PANEL 131CF HAS 2 EA TEMPORARY REPAIRS. PERMANENT REPAIR REQUIRED. GROUNDED - YES. PERFORMED PERMANENT REPAIR ON FWD…
- 27 Nov 2019
Skin, dented
AFT FUSELAGE SKIN DENT BTW FR 64/65 AND STR 40/41 LH. REF EA A320-53EA-00124. REQUIRES PERMANENT REPAIR. GROUNDED - YES. INSTALLED PERMANENT CATEGORY 'A'…
- 2 Apr 2017
Compressor, odor
CREW NOTICED A SLIGHT ELECTRICAL OR BURNED RUBBER ODOR. MX FOUND SOURCE OF THE ODOR TO BE POTABLE WATER AIR COMPRESSOR. MX DEACTIVATED COMPRESSOR AND PLACED…
- 3 Jun 2016
Control Unit, failed
ACFT EXPERIENCED A BRAKES ANTI SKID NOSE WHEEL STEERING FAULT AFTER TAKEOFF. ON ARRIVAL, THE ACFT WAS UNABLE TO TAXI OFF THE RUNWAY DUE TO NO NOSE WHEEL…
- 3 Jun 2016
Wire, damaged
EXPERIENCED AN ENGINE 1 REVERSE UNLOCKED ECAM MESSAGE ON LANDING ROLL-OUT AFTER THRUST REVERSER STOWED. TECHS APPLIED MEL 78-30-01 AND COMPLIED WITH ALL…
- 8 Apr 2014
Tube, corroded
INSPECTION SHOWED CORROSION ON THE NLG, BUSHED TURNING TUBE AT THE UPPER TORQUE LINK INNER SURFACE. THE BUSHINGS WERE REMOVED AND THE CORROSION WAS FOUND TO…
- 6 Apr 2014
Sill, corroded
LEFT AFT DOOR SILL HAS TWO AREAS OF CORROSION BETWEEN FRAMES 67-68, S23-24L Y1725. REPAIRED IAW SRM 53-41-14, FIG 201, REPAIR PRINCIPLE 5.
- 6 Apr 2014
Shear Plate, corroded
RIGHT AFT SHEAR PLATE BETWEEN FRAMES 69-70, S23-24R CORRODED BEYOND LIMITS. SHEAR PLATE R & R IAW SRM51-42-11.
- 6 Apr 2014
Shear Plate, corroded
LEFT AFT SHEAR PLATE BETWEEN FRAMES 69-70, S23-24L CORRODED BEYOND LIMITS. SHEAR PLATE R & R IAW SRM 51-42-11.
- 23 Apr 2011
Plate, broken
ACFT WAS UNDERGOING OVERNIGHT PLANNED MX THE MORNING OF 4/23/2011. DURING ACCOMPLISHMENT OF TASK CARD 521121-02-1-R2, A DOOR MECHANISM LUBE TASK, IT WAS NOTED…