N636BR
1999 Bombardier INC CL-600-2B19 standard FAA →
earlier registrations
1 past record
- 1999
service difficulty reports
15 reports
- 12 Sep 2008
Seat Track, corroded
LT FLOOR SEAT TRACK AT FS 424.0-513.0 FOUND TO BE CORRODED BEYOND LIMITS. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-41-00. (K)
- 12 Sep 2008
Seat Track, corroded
LT FLOOR SEAT TRACK AT FS 409.00+16-409.00+128 FOUND TO BE CORRODED BEYOND LIMITS. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-41-00. (K)
- 16 Aug 2008
Seat Track, corroded
(3) SEAT TRACK SECTIONS WERE FOUND TO BE CORRODED BEYOND LIMITS DURING AN INSPECTION AT WL 79.50 - FS 409.0+12 TO FS559.0 RT SIDE, WL 72.50 - FS 409.0+12 TO…
- 28 Jan 2005
Overheat Loop, malfunctioned
EVENT SUMMARY STATED ENG SHUTDOWN DURING FLIGHT. REMOVED AND REPLACED LT 14TH STAGE OVERHEAT LOOP REF 26-12-00. OPS CHECK GOOD AT THIS TIME.
- 14 Dec 2004
Warning System, false activation
LEFT PACK HIGH PRESSURE MESSAGE ON CLIMBOUT. OPS CHECK OF LT PACK, NO DEFECT NOTED.
- 23 Nov 2004
Sign, inoperative
LEFT EMERGENCY EXIT SIGN INOP. MX FOUND WIRE DISCONNECTED AND RECONNECTED IT. OPS CHECK GOOD.
- 3 Nov 2004
Proximity Switch, dirty
CREW SELECTED GEAR UP AFTER LIFT OFF AND RECEIVED FLUCTUATING UP/BARBER POLE/UP/BARBER POLE/ETC WITH ACCOMPANYING AURAL AND VISUAL GEAR DISAGREE WARNINGS.…
- 1 Nov 2004
Bracket, loose
MX FOUND RIGHT MLG UPLOCK PROXIMITY SENSOR TARGET BRACKET LOOSE. MANUAL MANIPULATION OF THE TARGET WITH THE GEAR RETRACTED CAUSED GEAR TO GO FROM SAFE TO…
- 20 Feb 2004
Wire, broken
DURING INSPECTION THE RIGHT HAND AFT EMERGENCY TRACK LIGHTING WAS FOUND INOPERATIVE. A WIRE WAS FOUND BROKEN BENEATH THE FLOORBOARDS AND REPAIRED. A…
- 3 Dec 2003
Battery, discharged
DURING INSPECTION THE EMERGENCY LIGHT WAS FOUND INOPERATIVE. THE PROBLEM WAS FOUND TO BE THE BATTERIES WERE DISCHARGED AND THEY WERE REPLACED. A SATISFACTORY…
- 17 Aug 2003
Light, inoperative
DURING MAINTENANCE INSPECTION THE EMERGENCY TRACK LIGHTING WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE EMERGENCY LIGHTING STRIP. A…
- 29 Jul 2003
Bulb, burned out
DURING INSPECTION THE CREW REPORTED THE 2 EXTERNAL EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED 2 RT EXTERNAL EMERGENCY…
- 21 Jul 2003
Light, inoperative
DURING MAINTENANCE INSPECTION A SECTION OF EMERGENCY TRACK LIGHTING WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED A SECTION OF EMERGENCY…
- 14 Jul 2003
Light, inoperative
DURING OVERNIGHT MAINTENANCE THE RT OVERWING EMERGENCY EXIT LIGHT WAS DISCOVERED INOPERATIVE. MAINTENANCE PERSONNEL RELAMPED THE OVERWING EMERGENCY LAMP. A…
- 13 Jun 2003
Bulb, burned out
DURING OVERNIGHT MAINTENANCE, MAINTENANCE PERSONNEL DISCOVERED THE EMERGENCY EXIT LIGHT AT THE PASSENGER DOOR WAS INOPERATIVE. MAINTENANCE PERSONNEL REPLACED…